Placing a Straumann Analog in the iTero Model

Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

Placing a Straumann Analogin the iTero Model

Page 2: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

Image of the iTero™ milled model with the socket for a Straumann® WN Repositionable Implant Analog

Page 3: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled model.Instruction: Lab just has to place the analog in the model and double checks that it sets properly.

Page 4: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

If the lab would like to check the position, they can use a fine tip marker, indicate where the Repositionable Implant Analog is at the base of the model

Page 5: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

Measure the distance between the bottom shoulder of the WN Repositionable Implant Analog and where the base of the model was

indicated.

Page 6: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

Remove the WN Repositionable Implant AnalogUsing your measurement, indicate where to drill on the model and drill a

<2.2mm hole

Page 7: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

The drill should perforate the socket where the Repositionable Implant will seat.

Page 8: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

Confirm the seating of the Repositionable Implant Analog in the iTero milled model socket. Lab can glue it in place in order to get more stability.

Page 9: Placing a Straumann Analog in the iTero Modelstoragy-itero-production-us.s3.amazonaws.com/... · The Straumann WN Repositionable Implant Analog “press-fit” into the iTero milled

If the lab has additional questions, please recommend them to contact Straumann.