PL 006-152August 2009
Parts List
1-, 2-, 3-, and 5-Valve Manifoldsfor Use With
I/A Series® Electronic Pressure Transmittersand
Pneumatic d/p Cell® Transmitters—
Style A
*Parts preceded by an asterisk are recommended spare parts.Give Instrument Model Number and Style when ordering.
See Recommended Spare Parts Summary section for quantities.
TO ORDER PARTS, CALL INVENSYS SYSTEMS INC. AT 1-866-746-6477.
PL 006-152Page ii
ContentsTABLES
Table 1. Manifold/Transmitter Compatibility and Application ..................................................................... 1 Table 2. Recommended Spare Part Summary.......................................................................................... 44
MODEL CODES, FIGURES, AND PARTS1-Valve Manifold (Block and Bleed Valve Models) - Also see Table 1.
M9; Commodity Version; Direct Connect to Transmitters; General Purpose........................................ 2
2-Valve Manifolds - Also see Table 1.PTM; Commodity Version; Direct Connect to Transmitters; General Purpose ..................................... 4M25; Standard Version; Direct Connect to Transmitters; General Purpose ......................................... 6M25-HP; Standard Version; Direct Connect to Transmitters; Power Service ....................................... 8PT7; Standard Version; Direct Connect to Transmitters; General Purpose.......................................... 10PT7M; Standard Version; Direct Connect to Transmitters; General Purpose....................................... 12M4AP; Standard Version; Traditional Structure Transmitters; General Purpose .................................. 14M4TP; Standard Version; Traditional Structure Transmitters; General Purpose .................................. 16
3-Valve Manifold Models - Also see Table 1.M4A; Standard Version; Traditional Structure Transmitters; General Purpose........................... 18
M4T; Standard Version; Traditional Structure Transmitters; General Purpose..................................... 20MB3; Standard Version; Low Profile Structure Transmitters; General Purpose ................................... 22MB3-HP; Standard Version; Low Profile Structure Transmitters; Power Service ................................. 24
5-Valve Manifold Models - Also see Table 1. M6TA; Standard Version; Traditional Structure Transmitters; Gen’l Purpose/Natural Gas Service ...... 26M6T; Standard Version; Traditional Structure Transmitters; Gen’l Purpose/Natural Gas Service ........ 28MB5G; Standard Version; Low Profile Structure Transmitters; Gen’l Purpose/Natural Gas Service.... 30MB5P; Standard Version; Low Profile Structure Transmitters; General Purpose................................. 32MB5P-HP; Standard Version; Low Profile Structure Transmitters; Power Service............................... 34M24A; Standard Version; Traditional Structure Transmitters; General Purpose................................... 36M24T; Standard Version; Traditional Structure Transmitters; General Purpose................................... 38
PL 006-152Page 1
(a) Low Profile = Low Profile Structure (CoplanarTM).(b) Commonly referred to as a Block and Bleed Valve.(c) Manifold is direct-connected to transmitter.
Table 1. MANIFOLD/TRANSMITTER COMPATIBILITY and APPLICATION
Manifold Model
No. of Valves
Version/Structure
(a) Used with Transmitter Models
Manifold Application
General Purpose
Natural Gas
Power Service
M9(b) 1 Commodity/
(c) IAP10, IGP10, IGP25, IGP50 X – –
PTM 2 Commodity/(c) IAP10, IGP10, IGP25, IGP50 X – –
PT7 2 Standard/(c) IAP10, IGP10, IGP25, IGP50 X – –
PT7M 2 Standard/(c) IAP10, IGP10, IGP25, IGP50 – – X
M25-VIM25-HI 2
Standard/(c) IAP10, IGP10, IGP25, IGP50 X – –
M25-HP 2 Standard/(c) IAP10, IGP10, IGP25, IGP50 – – X
M4AP 2 Standard/Traditional IAP20, IGP20 X – –
M4TP 2 Standard/Traditional IAP20, IGP20 X – –
M4A 3 Standard/Traditional
IDP10, IDP25, IDP50, IMV25IMV30, IMV31, 13A, 13HA, 15A X – –
M4T 3 Standard/Traditional
IDP10, IDP25, IDP50, IMV25IMV30, IMV31, 13A, 13HA, 15A X – –
MB3-VIMB3-HI 3 Standard/
Low Profile IDP10, IDP25, IDP50 X – –
MB3-HP 3 Standard/Low Profile IDP10, IDP25, IDP50 – – X
M6TA 5 Standard/Traditional
IDP10, IDP25, IDP50, IMV25IMV30, IMV31, 13A, 13HA, 15A X X –
M6T 5 Standard/Traditional
IDP10, IDP25, IDP50, IMV25IMV30, IMV31, 13A, 13HA, 15A X X –
MB5G 5 Standard/Low Profile IDP10, IDP25, IDP50 X X –
MB5P-VIMB5P-HI 5 Standard/
Low Profile IDP10, IDP25, IDP50 X – –
MB5P-HP 5 Standard/Low Profile IDP10, IDP25, IDP50 – – X
M24A 5 Standard/Traditional
IDP10, IDP25, IDP50, IMV25IMV30, IMV31, 13A, 13HA, 15A X – –
M24T 5 Standard/Traditional
IDP10, IDP25, IDP50, IMV25IMV30, IMV31, 13A, 13HA, 15A X – –
PL 006-152Page 2
(a) The M9 is a low cost, commodity version manifold (block and bleed valve). See Table 1 for transmitters used with this model.
MODEL M91-VALVE MANIFOLD (FIGURE 1)
M9 1-Valve Manifold AS Code - Commodity Version for General Purpose Applications
Description Model1-Valve Manifold (Block and Bleed Valve) - Commodity Version; for General Purpose Applications; (a)
1/2-14 NPT Connection to Process Used with Direct Connect Absolute or Gauge Pressure Transmitters.
M9
Bonnet PackingTeflon -V
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 JMonel 400 M
Process Connection1/2-14 NPT; External Thread 44
Optional SelectionsSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Examples: M9–VIC44; M9–VIS44–SG
PL 006-152Page 3
MODEL M91-VALVE MANIFOLD (FIGURE 1) (Cont.)
1/2 - 14 NPTPROCESS CONNECTION
FIE
LDT
ER
MIN
ALS +
TRANSMITTER(REFERENCE)
MODEL M9
BLEED VALVE
PL 006-152Page 4
(a) The PTM is a low cost, commodity version 2-valve manifold.See Table 1 for transmitters used with this model.
MODEL PTM2-VALVE MANIFOLD (FIGURE 2)
PTM 2-Valve Manifold AS Code - Commodity Version for General Purpose Applications
Description Model2-Valve Manifold - Commodity Version; for General Purpose Applications; (a)
1/2-14 NPT Connection to ProcessUsed with Direct Connect Absolute or Gauge Pressure Transmitters.
PTM
Bonnet PackingTeflon -V
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 JMonel 400 M
Process Connection1/2-14 NPT; External Thread 44
Optional SelectionsSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Examples: PTM–VIC44; PTM–VIS44–SG
PL 006-152Page 5
MODEL PTM2-VALVE MANIFOLD (FIGURE 2) (Cont.)
1/2 - 14 NPT PROCESS PORT
TRANSMITTER(REFERENCE)
MODEL PTM
BLOCK VALVE
VENT/TEST VALVE
1/2 - 14 NPTBLEED PORT
MOUNTING HOLES 0.281 in DIA.(2)
PL 006-152Page 6
(a) The M25-VI and M25-HI are 2-valve manifolds for general purpose applications. See Table 1 for transmitters used with this model.
MODEL M25-VI AND M25-HI2-VALVE MANIFOLD (FIGURE 3)
M25-VI and M25-HI 2-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model2-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT Connection to ProcessUsed with Direct Connect Absolute or Gauge Pressure Transmitters.
M25
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 41/4-14 NPT; External Thread 44
Optional SelectionsAGCO Mounting Kit -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: M25–VIC44; M25–VIS44–SG
PL 006-152Page 7
MODEL M25-VI AND M25-HI2-VALVE MANIFOLD (FIGURE 3) (Cont.)
FIE
LDT
ER
MIN
ALS +
AN
DERSO
N, G
REENW
OO
DIN
STRUM
ENT G
AU
GE VA
LVE
TYPE
ASSY
BO
DY
TERM
PSI AT
PSI AT
°F°FM
1/2 - 14 NPTPROCESS CONNECTION
TRANSMITTER(REFERENCE)
MODEL M25
BLOCK VALVEVENT VALVE
PL 006-152Page 8
(a) The M25-HP is a 2-valve manifold for Power Industry applications. See Table 2 for transmitters used with this manifold.
Model M25-HP Part Numbers for Ordering Manifolds
(a) Refer to M25-HP AS Code table above for manifold descriptions.
MODEL M25-HP2-VALVE MANIFOLD (FIGURE 4)
M25-HP 2-Valve Manifold AS Code - Standard Version for Power Industry Applications
Description Model2-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT Connection to ProcessUsed with Direct Connect Absolute or Gauge Pressure Transmitters.
M25
Bonnet PackingGrafoil -H
Seat MaterialIntegral (same as body material); for Power Industry Applications P
Body Material316 ss S
Process Connection1/2-14 NPT; Internal Thread 41/4-14 NPT; External Thread 44
Optional SelectionsAGCO Mounting Kit -AM
Examples: M25–HPS4; M25–HPS44–AM
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
D0197MY AS Code M25-HPS4 –D0197MZ AS Code M25-HPS44 –D0197NA AS Code M25-HPS4-AM –D0197NB AS Code M25-HPS44-AM –
PL 006-152Page 9
MODEL M25-VI AND M25-HI2-VALVE MANIFOLD (FIGURE 4) (Cont.)
FIE
LDT
ER
MIN
ALS +
AN
DERSO
N, G
REENW
OO
DIN
STRUM
ENT G
AU
GE VA
LVE
TYPE
ASSY
BO
DY
TERM
PSI AT
PSI AT
°F°FM
1/2 - 14 NPTPROCESS CONNECTION
TRANSMITTER(REFERENCE)
MODEL M25
BLOCK VALVEVENT VALVE
PL 006-152Page 10
(a) The PT7 is a 2-valve manifold for use in general purpose applications. See Table 1 for transmitters used with this model.
MODEL PT72-VALVE MANIFOLD (FIGURE 5)
PT7 2-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model2-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT Connection to Process Used with Direct Connect Absolute or Gauge Pressure Transmitters.
PT7
Bonnet PackingTeflon -V
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mounting Kit for mounting manifold to 2-inch Pipe Stand -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: PT7–VIC44; PT7–VIS44–SG
PL 006-152Page 11
MODEL PT72-VALVE MANIFOLD (FIGURE 5) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, and bolts, nuts, and washers as shown in Figure 5 above.
Item Part No. Qty. Part Name1 D0197FD 1 Mount Kit, AGCO, Option -AM; See Note.
1/2 - 14 NPT PROCESS PORT
TRANSMITTER(REFERENCE)
MODEL PT7
BLOCK VALVE
VENT/TEST VALVE
NUTS AND WASHERS (2)SEE NOTE
U-BOLTSEE NOTE
WASHERSAND NUTS (2)SEE NOTE
1/2 - 14 NPTBLEED PORT
SEE NOTE
1
BOLTS ANDWASHERS (2)SEE NOTE
PL 006-152Page 12
(a) The PT7 is designed for use in power industry applications. See Table 1 for transmitters used with this model.
MODEL PT7M2-VALVE MANIFOLD (FIGURE 6)
PT7M 2-Valve Manifold AS Code - Standard Version for Power Industry Applications
Description Model2-Valve Manifold - Standard Version; for Power Industry Applications; (a)
1/2-14 NPT Connection to ProcessUsed with Direct Connect Absolute or Gauge Pressure Transmitters.
PT7M
Bonnet PackingGrafoil -H
Seat MaterialIntegral (same as body material)
(Hydrostatic testing and bonnet locks)-P
Body Material316 ss S
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mounting Kit for mounting manifold to 2-inch Pipe Stand (steel) -AMClean for Oxygen Service -OCASME Standard B31.1 for Power Service -XP
Examples: PT7M–HPS4; PT7M–HPS4–AM–XP
PL 006-152Page 13
MODEL PT7M2-VALVE MANIFOLD (FIGURE 6) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, and bolts, nuts, and washers as shown in Figure 6 above.
Item Part No. Qty. Part Name1 D0197FD 1 Mount Kit, AGCO, Option -AM; See Note.
1/2 - 14 NPT PROCESS PORT
TRANSMITTER(REFERENCE)
MODEL PT7M
BLOCK VALVE
VENT/TEST VALVE
NUTS AND WASHERS (2)SEE NOTE
U-BOLTSEE NOTE
WASHERSAND NUTS (2)SEE NOTE
1/2 - 14 NPTBLEED PORT
SEE NOTE
1
BOLTS ANDWASHERS (2)SEE NOTE
PL 006-152Page 14
(a) The M4AP is a 2-valve manifold with a flange end connection to the process. See Table 1 for transmitters used with this model.
MODEL M4AP2-VALVE MANIFOLD (FIGURE 7)
M4AP 2-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model2-Valve Static Pressure Manifold - Standard Version; for General Purpose Applications; (a)
Flange End Connection to Process Used with Bracket Mounted Absolute or Gauge Pressure Transmitters.
M4AP
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 J
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: M4AP–VIC–AM; M4–VIS–AM–SG; M4VIJ–AM–SG3; M4AP–VIS–AM–OC
PL 006-152Page 15
MODEL M4AP2-VALVE MANIFOLD (FIGURE 7) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, a spacer block, and spacers, bolts, nuts, and washers as shown in Figure 7 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 2 Gasket, ptfe3 X0100MN 2 Bolt, Hex Hd; B7; 0.438-20 X 1.54 D0197FF 1 Mount Kit, AGCO; Option -AM; See Note.
U-BOLTSEE NOTE.
MODEL M4AP
CONNECTOR
6.4 mm (0.25 in)SPACERS (2)SEE NOTE.
BOLTS (3)SEE NOTE.
TRANSMITTER(REFERENCE)
(4) PLACES
1
(2) PLACES
3
2
SEE NOTE.4
WASHERSAND NUTS (2)SEE NOTE.
WASHERSAND NUTS (3)SEE NOTE.
SPACER BLOCKSEE NOTE.
2
PL 006-152Page 16
(a) The M4TP is a 2-valve manifold with a 1/2-14 NPT connection to the process. See Table 1 for transmitters used with this model.
Model M4TP Part Numbers for Ordering Manifolds
(a) Refer to M4TP AS Code table above for manifold descriptions.
MODEL M4TP2-VALVE MANIFOLD (FIGURE 8)
M4TP 2-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model2-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT Connection to Process Used with Bracket Mounted Absolute or Gauge Pressure Transmitters.
M4TP
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm).]
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: M4TP–VIC4–AM; M4TP–VIS4–AM–SG
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
D0161UT AS Code M4TP-VIC4 BM-M4TP-VIC-4D0161UU AS Code M4TP-VIS4 BM-M4TP-VIS-4D0161UV AS Code M4TP-VIS4-SG BM-M4TP-VIS-4-SGD0161UW AS Code M4TP-VIC4-AM BM-M4TP-VIC-4-AMD0161UX AS Code M4TP-VIS4-AM BM-M4TP-VIS-4-AMD0161UY AS Code M4TP-VIS4-AM-SG BM-M4TP-VIS-4-AM-SG
PL 006-152Page 17
MODEL M4TP2-VALVE MANIFOLD (FIGURE 8)(Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, a spacer, and bolts, nuts, and washers as shown in Figure 8 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 1 Gasket, ptfe3 D0197FF 1 Mount Kit, AGCO, Option -AM; See Note.
WASHERS AND NUTS (2)SEE NOTE
TRANSMITTER(REFERENCE)
(4) PLACES
1
WASHERS AND NUTS (2)SEE NOTE
SEE NOTE
U-BOLTSEE NOTE3
6.4 mm (0.25 in)SPACERSEE NOTE
BOLTS (2)SEE NOTE
1/2 - 14 NPTPROCESS PORT
MODEL MT4P
2
3
PL 006-152Page 18
(a) The M4A is a 3-valve manifold with a flange end connection to the process, See Table 1 for transmitters used with this model.
Model M4A Part Numbers for Ordering Manifolds
(a) Refer to M4A AS Code table above for manifold descriptions.
MODEL M4A3-VALVE MANIFOLD (FIGURE 9)
M4A 3-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model3-Valve Manifold - Standard Version; for General Purpose Applications; (a)
Flange End Connection to ProcessUsed with Bracket Mounted d/p Cell Transmitters with Traditional Structure.
M4A
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 J
Optional SelectionsAGCO Mounting Kit for mounting manifold to 2-inch Pipe Stand -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: M4A–VIC–AM; M4A–VIS–SG; M4A–VJ–SG3
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
B0152MC AS Code M4A-VIC BM-M4VCM0155LE AS Code M4A-VIC-AM M4AVIC-AMB0152ME AS Code M4A-VIS BM-M4AVSM0155LD AS Code M4A-VIS-AM M4AVS-AMM0155AH AS Code M4A-VIS-SG M4AVIS-SGA0109SY AS Code M4A-VIS-OC OS-BM-M4AVSM0155LB AS Code M4A-VIS-AM-SG M4AVIS-AM-SGM0155LC AS Code M4A-VIS-AM-OC M4AVIS-AM-LOC
PL 006-152Page 19
MODEL M4A3-VALVE MANIFOLD (FIGURE 9) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, a spacer block, and spacers, bolts, nuts, and washers as shown in Figure 9 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 4 Gasket, ptfe3 X0100MN 4 Bolt, Hex Hd; B7; 0.438-20 X 1.54 D0197FE 1 Mount Kit, AGCO; Option -AM; See Note.
WASHERS AND NUTS (3)SEE NOTE.
SPACER BLOCKSEE NOTE.
U-BOLTSEE NOTE.
(4) PLACES
CONNECTOR (2)
6.4 mm (0.25 in)SPACERS (2)SEE NOTE.
BOLTS (3)SEE NOTE.
TRANSMITTER(REFERENCE)
(4) PLACES
1
MODEL M4A
(4) PLACES3
SEE NOTE.4
WASHERS AND NUTS (2)SEE NOTE.
(4) PLACES
2
2
PL 006-152Page 20
(a) The M4T is a 3-valve manifold with a 1/2-14 NPT end connection to the process. See Table 1 for transmitters used with this model.
Model M4T Part Numbers for Ordering Manifolds
(a) Refer to M4T AS Code table above for manifold descriptions.
MODEL M4T3-VALVE MANIFOLD (FIGURE 10)
M4T 3-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model3-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT End Connection to ProcessUsed with Bracket Mounted d/p Cell Transmitters with Traditional Structure.
M4T
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mounting Kit for mounting manifold to 2-inch Pipe Stand -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: M4T–VIC4; M4T–VIS4–SG; M4T–VIS4–AM–SG; M4T–VIJ4–SG3; M4T–VIS4–AM–OC
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
P0121EX AS Code M4T-VIC4 M4TVIC-4M0155LH AS Code M4T-VIC4-AM M4TVIC-4-AMP0121EY AS Code M4T-VIS4 M4TVIS-4M0155LG AS Code M4T-VIS4-AM M4TVIS-4-AMM0155AJ AS Code M4T-VIS4-SG M4TVIS-4-SGM0155LF AS Code M4T-VIS4-AM-SG M4TVIS-4-AM-SG
PL 006-152Page 21
MODEL M4T3-VALVE MANIFOLD (FIGURE 10)(Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, a spacer, and bolts, nuts, and washers as shown in Figure 10 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 2 Gasket, ptfe3 D0197FE 1 Mount Kit, AGCO; Option -AM; See Note.
WASHERS AND NUTS (2)SEE NOTE.
U-BOLTSEE NOTE.
SPACERSEE NOTE.
BOLTS (2)SEE NOTE.
1/2 - 14 NPTPROCESS PORT (2)
TRANSMITTER(REFERENCE)
(4) PLACES
1
MODEL M4T
SEE NOTE.3
WASHERS AND NUTS (2)SEE NOTE.
(2) PLACES
2
PL 006-152Page 22
(a) The MB3-VI and MB3-HI 3-valve manifolds are for General Purpose Applications. See Table 1 for transmitters used with this model.
Model MB3-VI and MB3-HI Part Numbers for Ordering Manifolds
(a) Refer to MB3-VI and MB3-HI AS Code table above for manifold descriptions.
MODEL MB3-VI and MB3-HI3-VALVE MANIFOLD (FIGURE 11)
MB3-VI and MB3-HI 3-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model3-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT Connection to ProcessUsed with Bracket Mounted d/p Cell Transmitters with Low Profile Structure.
MB3
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body MaterialCarbon Steel (cs) C316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: MB3–VIS4; MB3–VIS4–SG–AM
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
D0179ZA AS Code MB3-VIS4 BM-MB3VIS-4D0179ZB AS Code MB3-VIS4-AM BM-MB3VIS-4-AMD0179ZD AS Code MB3-VIS4-OC BM-MB3VIS-4-OCD0179ZE AS Code MB3-VIS4-SG BM-MB3VIS-4-SGD0179ZF AS Code MB3-VIS4-AM-OC BM-MB3VIS-4-AM-OCD0179ZH AS Code MB3-VIS4-AM-SG BM-MB3VIS-4-AM-SG
PL 006-152Page 23
MODEL MB3-VI and MB3-HI3-VALVE MANIFOLD (FIGURE 11)(Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, and bolts, nuts, and washers as shown in Figure 11 above.
Item Part No. Qty. Part Name1 X0100YA 4 Bolt, Hex Hd; B7; 0.438-20 X 1.75
*2 D0114RB 2 Gasket, ptfe3 D0197FG 1 Mount Kit, AGCO; See Note.
TRANSMITTER(REFERENCE)
MODEL MB3
WASHERS AND NUTS (2)SEE NOTE.
U-BOLTSEE NOTE.
(4) PLACES
1
(2) PLACES
2
SEE NOTE.3
MOUNTING BOLTSAND WASHERS (2)SEE NOTE.
PL 006-152Page 24
(a) The MB3-HP 3-valve manifolds are for General Purpose Applications. See Table 2 for transmitters used with this model.
Model MB3-HP Part Numbers for Ordering Manifolds
(a) Refer to MB3-HP AS Code table above for manifold descriptions.
MODEL MB3-HP3-VALVE MANIFOLD (FIGURE 12)
MB3-HP 3-Valve Manifold AS Code - Standard Version for Power Industry Applications
Description Model3-Valve Manifold - Standard Version; for Power Industry Applications (a) MB3
Bonnet PackingGrafoil -H
Seat MaterialIntegral (same as body material); for Power Industry Applications P
Body Material316 ss S
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit -AMClean for Oxygen Service (not available with carbon steel body material) -OC
Examples: MB3–VIS4; MB3–VIS4–SG–AM
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
D0179ZU AS Code MB3-HPS4 MB3HPS-4-XPD0179ZV AS Code MB3-HPS4-AM MB3HPS-4-XP-AM
PL 006-152Page 25
MODEL MB3-HP3-VALVE MANIFOLD (FIGURE 12) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, and bolts, nuts, and washers as shown in Figure 12 above.
Item Part No. Qty. Part Name1 X0100YA 4 Bolt, Hex Hd; B7; 0.438-20 X 1.75
*2 D0114RB 2 Gasket, ptfe3 D0197FG 1 Mount Kit, AGCO; See Note.
TRANSMITTER(REFERENCE)
MODEL MB3
WASHERS AND NUTS (2)SEE NOTE.
U-BOLTSEE NOTE.
(4) PLACES
1
(2) PLACES
2
SEE NOTE.3
MOUNTING BOLTSAND WASHERS (2)SEE NOTE.
PL 006-152Page 26
(a) This 5-valve manifold with a flange end connection is for natural gas applications. See Table 1 for transmitters used with the M6TA.
MODEL M6TA5-VALVE MANIFOLD (FIGURE 13)
M6TA 5-Valve Manifold AS Code - Standard Version for Natural Gas Applications
Description Model5-Valve Manifold - Standard Version; for Natural Gas Applications; (a)
Flange End Connection to ProcessUsed with Bracket Mounted d/p Cell Transmitters with Traditional Structure.
M6TA
Bonnet PackingTeflon -V
Seat MaterialDelrin (for Natural Gas Applications) DIntegral (same as body material) (for General Purpose Applications) I
Body MaterialCarbon Steel (cs) C316 ss S
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: M6TA–VDS–SG; M6TA–VDS–SG–AM
PL 006-152Page 27
MODEL M6TA5-VALVE MANIFOLD (FIGURE 13) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, U-bolts, a spacer, and bolts, nuts, and washers as shown in Figure 13 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 4 Gasket, ptfe3 X0100MN 4 Bolt, Hex Hd; 0.438-20 X 1.54 D0197FH 1 Mount Kit, AGCO; See Note.
CONNECTORS (2)13 mm (1/2 in)SPACERSEE NOTE.
BOLTS (3)SEE NOTE.
WASHERS AND NUTS (3)SEE NOTE.
TRANSMITTER(REFERENCE)
(4) PLACES
1
MODEL M6TA
(4) PLACES3
(4) PLACES2
SEE NOTE.
4
(4) PLACES
2
U-BOLTSEE NOTE.
WASHERS AND NUTS (3)SEE NOTE.
PL 006-152Page 28
MODEL M6T5-VALVE MANIFOLD (FIGURE 14)
(a) This 5-valve manifold with a 1/2-14 NPT connection is for natural gas applications. See Table 1 for transmitters used with the M6T.
M6T 5-Valve Manifold AS Code - Standard Version for Natural Gas Applications
Description Model5-Valve Manifold - Standard Version; for Natural Gas Applications; (a)
1/2-14 NPT End Connection to ProcessUsed with Bracket Mounted d/p Cell Transmitters with Traditional Structure.
M6T
Bonnet PackingTeflon -V
Seat MaterialDelrin (for Natural Gas Applications) DIntegral (same as body material) (for General Purpose Applications) I
Body MaterialCarbon Steel (cs) C316 ss S
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: M6T–VIC4; M6T–VDS4–SG; M6T–VDS4–AM–OC
PL 006-152Page 29
MODEL M6T5-VALVE MANIFOLD (FIGURE 14) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, U-bolts, a spacer, and bolts, nuts, and washers as shown in Figure 14 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 2 Gasket, ptfe3 D0197FH 1 Mount Kit, AGCO; See Note.
1/2 - 14 NPTPROCESS PORTS (2)13 mm (1/2 in)
SPACERSEE NOTE.
BOLTS (3)SEE NOTE.
WASHERS AND NUTS (3)SEE NOTE.
1/4 - 14 NPTVENT PORT
TRANSMITTER(REFERENCE)
(4) PLACES
1
MODEL M6T
SEE NOTE.
3
WASHERS AND NUTS (4)SEE NOTE.
U-BOLTSEE NOTE.
(2) PLACES
2
PL 006-152Page 30
(a) This 5-valve manifold with a 1/2-14 NPT connection is for natural gas applications. See Table 1 for transmitters used with the MB5G.
Model MB5G Part Numbers for Ordering Manifolds
(a) Refer to MB5G AS Code table above for manifold descriptions.
MODEL MB5G5-VALVE MANIFOLD (FIGURE 15)
MB5G 5-Valve Manifold AS Code - Standard Version for Natural Gas Applications
Description Model5-Valve Manifold - Standard Version; for Natural Gas Applications; (a)
1/2-14 NPT End Connection to ProcessUsed with Bracket Mounted d/p Cell Transmitters with Low Profile Structure.
MB5G
Bonnet PackingTeflon -V
Seat MaterialDelrin (for Natural Gas Applications) DIntegral (same as body material) (for General Purpose Applications) I
Body Material316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: MB5G–VDS4; MB5G–VIS4–SG; MB5G–VIJ4–SG3–AM; MB5G–VIS4–AM–OC
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
D0179ZK AS Code MB5G-VIS4 MB5GVIS-4D0179ZL AS Code MB5G-VIS4-AM MB5GVIS-4-AMD0179ZN AS Code MB5G-VIS4-OC MB5GVIS-4-OCD0179ZP AS Code MB5G-VIS4-SG MB5GVIS-4-SGD0179ZQ AS Code MB5G-VIS4-AM-OC MB5GVIS-4-AM-OCD0179ZS AS Code MB5G-VIS4-AM-SG MB5GVIS-4-AM-SG
PL 006-152Page 31
MODEL MB5G5-VALVE MANIFOLD (FIGURE 15) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, and bolts, nuts, and washers as shown in Figure 15 above.
Item Part No. Qty. Part Name1 X0100YA 4 Bolt, Hex Hd; B7; 0.438-20 X 1.75
*2 D0114RB 2 Gasket, ptfe3 D0197FG 1 Mount Kit, AGCO; See Note.
MOUNTING BOLTSAND WASHERS (2)SEE NOTE.
TRANSMITTER(REFERENCE)
(2) PLACES
2
MODEL MB5G
SEE NOTE.
3
WASHERS AND NUTS (2)SEE NOTE.
U-BOLTSEE NOTE.(4) PLACES
1
PL 006-152Page 32
(a) These 5-valve manifolds are used for general purpose applications. See Table 1 for transmitters used with these models.
MODEL MB5P-VI and MB5P-HI5-VALVE MANIFOLD (FIGURE 16)
MB5P-VI and MB5P-HI 5-Valve Manifold AS Code - Standard Version
Description Model5-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT End Connection to Process Used with Bracket Mounted d/p Cell Transmitters with Low-Profile Structure.
MB5P
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral Seat (same as body material) I
Body Material316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service (not available with carbon steel body material) -OC
Examples: MB5P–VIS4; MB5P–VIJ4–SG3–AM
PL 006-152Page 33
MODEL MB5P-VI and MB5P-HI5-VALVE MANIFOLD (FIGURE 16) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, and bolts, nuts, and washers as shown in Figure 16 above.
Item Part No. Qty. Part Name1 X0100YA 4 Bolt, Hex Hd; B7; 0.438-20 X 1.75
*2 D0114RB 2 Gasket, ptfe3 D0197FG 1 Mount Kit, AGCO; See Note.
MOUNTING BOLTSAND WASHERS (2)SEE NOTE.
TRANSMITTER(REFERENCE)
SEE NOTE.
3
WASHERS AND NUTS (2)SEE NOTE.
(4) PLACES
1
(2) PLACES
2
U-BOLTSEE NOTE.
MODEL MB5P
PL 006-152Page 34
(a) The MB5P-HP 5-valve manifold is for power industry applications. See Table 1 for transmitters used with this manifold.
Model MB5G Part Numbers for Ordering Manifolds
(a) Refer to MB5P-HP AS Code table above for manifold descriptions.
MODEL MB5P-HP5-VALVE MANIFOLD (FIGURE 17)
MB5P-HP 5-Valve Manifold AS Code - Standard Version for Power Industry Applications
Description Model5-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT End Connection to Process Used with Bracket Mounted d/p Cell Transmitters with Low-Profile Structure.
MB5P
Bonnet PackingGrafoil -H
Seat MaterialIntegral Seat (same as body material); for Power Industry Applications P
Body Material316 ss S
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit -AM
Examples: MB5P–HPS4–AM
Foxboro Part Number Auxiliary Specification Code (a) Previous AS Code
D0179ZX AS Code MB5P-HPS4 MB5PHPS-4-XPD0179ZY AS Code MB5P-HPS4-AM MB5PHPS-4-XP-AM
PL 006-152Page 35
MODEL MB5P-HP5-VALVE MANIFOLD (FIGURE 17) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, and bolts, nuts, and washers as shown in Figure 17 above.
Item Part No. Qty. Part Name1 X0100YA 4 Bolt, Hex Hd; B7; 0.438-20 X 1.75
*2 D0114RB 2 Gasket, ptfe3 D0197FG 1 Mount Kit, AGCO; See Note.
MOUNTING BOLTSAND WASHERS (2)SEE NOTE.
TRANSMITTER(REFERENCE)
SEE NOTE.
3
WASHERS AND NUTS (2)SEE NOTE.
(4) PLACES
1
(2) PLACES
2
U-BOLTSEE NOTE.
MODEL MB5P
PL 006-152Page 36
(a) The M24A 5-valve manifold has a flange end connection to the process. See Table 1 for transmitters used with this model.
MODEL M24A5-VALVE MANIFOLD (FIGURE 18)
M24A 5-Valve Manifold AS Code- Standard Version for General Purpose Applications
Description Model5-Valve Manifold - Standard Version; for General Purpose Applications; (a)
Flange End Connection to Process Used with Bracket Mounted d/p Cell Transmitters with Traditional Structure.
M24A
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body Material316 ss SHastelloy C-276 J
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service -OC
Examples: M24A–VIS; M24A–VIJ–SG3–AM
PL 006-152Page 37
MODEL M24A5-VALVE MANIFOLD (FIGURE 18) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, a spacer block, and bolts, nuts, and washers as shown in Figure 18 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 4 Gasket, ptfe3 X0100MN 4 Bolt, Hex Hd; B7; 0.438-20 X 1.54 D0197FJ 1 Mount Kit, AGCO; Option -AM; See Note.
SPACER BLOCKSEE NOTE.
CONNECTORS (2)
TRANSMITTER(REFERENCE)
(4) PLACES
1
(4) PLACES
2MODEL M24A
(4) PLACES
3
(4) PLACES2
SEE NOTE.4
WASHERS AND NUTS (2)SEE NOTE.
BOLTS (2)SEE NOTE.
U-BOLTSEE NOTE.
PL 006-152Page 38
(a) The M24T is a standard version 5-valve manifold with a 1/2-14 NPT end connection. See Table 1 for transmitters used with this model.
MODEL M24T5-VALVE MANIFOLD (FIGURE 19)
M24T 5-Valve Manifold AS Code - Standard Version for General Purpose Applications
Description Model5-Valve Manifold - Standard Version; for General Purpose Applications; (a)
1/2-14 NPT End Connection to Process Used with Bracket Mounted d/p Cell Transmitters with Traditional Structure.
M24T
Bonnet PackingTeflon -VGrafoil -H
Seat MaterialIntegral (same as body material) I
Body Material316 ss SHastelloy C-276 J
Process Connection1/2-14 NPT; Internal Thread 4
Optional SelectionsAGCO Mount Kit for 2-inch Pipe Stand Mounting of Manifold -AMSour Gas Applications - for use with Body Material Code S only.
Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions ≤ 50 mg/L (ppm)], and NACE MR0103-2005.
-SG
Sour Gas Applications - for use with Body Material Code J only.Meets requirements of NACE MR0175/ISO 15156-3CORRIGENDUM 2 [for chloride conditions > 50 mg/L (ppm)].
-SG3
Clean for Oxygen Service -OC
Examples: M24T–VIS4; M24T–VIS4–SG; M24T–VIJ4–SG3–AM
PL 006-152Page 39
MODEL M24T5-VALVE MANIFOLD (FIGURE 19) (Cont.)
NOTEThe Optional AGCO Mount Kit (Option -AM) comprises a mounting bracket, a U-bolt, a spacer block, and bolts, nuts, and washers as shown in Figure 19 above.
Item Part No. Qty. Part Name1 X0171PY 4 Bolt, Hex Hd; B7; 0.438-20 X 0.875
*2 D0114RB 2 Gasket, ptfe3 D0197FJ 1 Mount Kit, AGCO; Option -AM; See Note.
1/2 - 14 NPTPROCESS PORTS (2)
TRANSMITTER(REFERENCE)
(4) PLACES
1
(2) PLACES
2MODEL M24T
SPACER BLOCKSEE NOTE.
SEE NOTE.3
WASHERS AND NUTS (2)SEE NOTE.
BOLTS (2)SEE NOTE.
U-BOLTSEE NOTE.
PL 006-152Page 40
Table 2. RECOMMENDED SPARE PARTS SUMMARY
FigureNumber
ItemNumber
PartNumber Part Name
Number of Parts Recommended for
1 Inst. 5 Inst. 20 Inst.
7 2 D0114RB Gasket, ptfe 4 12 248 2 D0114RB Gasket, ptfe 2 12 249 2 D0114RB Gasket, ptfe 4 12 2410 2 D0114RB Gasket, ptfe 6 18 3011 2 D0114RB Gasket, ptfe 4 12 2412 2 D0114RB Gasket, ptfe 4 12 2413 2 D0114RB Gasket, ptfe 4 12 2414 2 D0114RB Gasket, ptfe 6 18 3015 2 D0114RB Gasket, ptfe 4 12 2416 2 D0114RB Gasket, ptfe 4 12 2417 2 D0114RB Gasket, ptfe 4 12 2418 2 D0114RB Gasket, ptfe 4 12 2419 2 D0114RB Gasket, ptfe 6 18 30
IPS Corporate Headquarters5601 Granite Parkway Suite 1000Plano, TX 75024www.ips.invensys.com
Foxboro Global Client SupportInside U.S.: 1-866-746-6477Outside U.S.: 1-508-549-2424 or contact your local Foxboro representative.Facsimile: 1-508-549-4999
Invensys, Foxboro, I/A Series, IPS Logo, and d/p Cell are trademarks of Invensys plc, its subsidiaries, and affiliates.All other brand names may be trademarks of their respective owners.
Copyright 2009 Invensys Systems, Inc.All rights reserved
MB 150 Printed in U.S.A. 0809