3
Piping Hoop Stress Calculation: P Operating Pressure 590 D Inner Diameter 36 t Thickness 1.44 Allowable Strength @operating temperature 16509.646 Hoop stress 7388.33 Piping Hoop Stress is less than 50% of Allowable Stress σa σh

Piping Hoop Stress Calculation @ Operating Temperature

Embed Size (px)

DESCRIPTION

hoop stress

Citation preview

Page 1: Piping Hoop Stress Calculation @ Operating Temperature

Piping Hoop Stress Calculation:

P Operating Pressure 590 PsiD Inner Diameter 36 incht Thickness 1.44 inch

Allowable Strength @operating temperature 16509.646 Psi

Hoop stress 7388.33 Psi

Piping Hoop Stress is less than 50% of Allowable Stress

σa

σh

Page 2: Piping Hoop Stress Calculation @ Operating Temperature

Piping Hoop Stress is less than 50% of Allowable StressPiping Hoop Stress is not less than 50% of Allowable Stress