Piping – slide 29 Schlumberger Private PIPING Line sizing: gas/fluid velocities limitations to maximum : - 80 ft/sec if solids (sand) or 2-phase flow. - 160 ft/sec for dry gas. •if higher velocity expected, a full HAZOP is required as : - increase pipe ID, flare tip ID. - divers flow through more than one pipe. - reduce as much as practical the line length and number of bends - reduce the choke size. See FOH 1, Section 11 page 13 for gas velocity chart.