2

Pilot Operated Flare Stack1

Embed Size (px)

DESCRIPTION

Pilot Operated Flare Stack catalog

Citation preview

Page 1: Pilot Operated Flare Stack1

APPLICATIONS

Onshore operations: clean up, flowback, well testing and drill out

Disposal of produced gases during temporary operations

Disposal of hazerdous gases such as H2S, CO2, etc

Used for relieUsed for relief vent piping, away from area where personnel could be in danger

Green completions require total burn of all vented gases

Well-site intervention services

Allows temporary disposal of produced gas during temporary well site intervention services

The 6” x 60’ meets 40 CFR 60.18 Subpart A, 98% burn when keeping inside the design envelope

ContiContinuous pilot light to ensure gas flare ignition

Reduces carbon emissions

Small safe distance footprint during flow of hazardous gases

Drip pots or condensate traps on all Covenant Flare Stacks

All Flare StaAll Flare Stacks are trailer mounted and self elevating with hydraulics

Air assist available

APPLICATIONS

FEATURES & BENEFITSFEATURES & BENEFITS

Covenant’s Flare Stack is used to dispose of produced gas during land operations for cleanup, flowback, well testing, and initial drill out operations. The Flare Stack allows for gas to be burned at a safe distance from the work area, protecting workers and the environment. Flare Stacks are also required for hazardous environment gas disposal such as H2S/C02 and used as the relief flow disposal point when relief lines are extended for safe operationoperations. All are designed to burn with up to 98% efficiency. All flare stacks are provided with a gas pilot and electronic ignition system.

PRODUCTION TESTINGFLARE STACK

Page 2: Pilot Operated Flare Stack1

Copyright @ 2014 Covenant Testing Technologies, LLC. All rights reserved.

CTEST.COM 832.500.31071600 Highway 6, Suite 360Sugar Land, TX 77478

Working Pressure psi

Main Flare Line Sizein

Additional Lines, Size & Quantity

Elevation Type

Condensate Trap

Gas Inlet

Ignition Fuel

Ignition System

GasMMSCF/D

Weightlbs

Guide Lines, Self Supporting

Design TIP

4” x 25’4” x 25’

4” Sch. 40

3” 206

Hydraulic

Yes

4” 206

Propane

Continuous Ignition Spark

4 MM/scf/D400’ Per Second

6,000

Self Supporting with Guide Wires

Pipe Standard

1,200

4” Sch. 40

3” 206

Hydraulic

Yes

4” 206

Propane

Continuous Ignition Spark

4-6 MM/scf/D400’ Per Second

11,800

Self Supporting with Guide Wires

Pipe Standard

1,200

6” Sch. 40

3” 206

Hydraulic

Yes

6” 206

Propane

Continuous Ignition Spark

9-11 MM/scf/D400’ Per Second

15,600

Self Supporting With Guide Wires

High Efficiency or Pipe Standard

1,200

6” x 60’6” x 60’4” x 40’4” x 40’