5
P&ID – Jedson Program 1- How to draw a primary/secondary line? Piping Routing Primary/secondary line. 2- Properties We define size(diameter) - plan no. Determined in 2 ways: a) Properties of line( right bottom of window). b) Labels (In piping Labels…) Define constants status: New Existing Future. 3- Valves – Catalog Explorer . Valves → choose type of valves → Determine size + diameter consistency

P&ID guide

Embed Size (px)

DESCRIPTION

P&ID guide for P&ID program

Citation preview

P&ID Jedson Program1- How to draw a primary/secondary line?

Piping Routing Primary/secondary line.2- Properties

We define size(diameter) - plan no.

Determined in 2 ways: a) Properties of line( right bottom of window).

b) Labels (In piping Labels)

Define constants status: New

Existing

Future.

3- Valves Catalog Explorer.

Valves choose type of valves Determine size + diameter consistencyThen: label for valves piping components commodity code Nominal diameter.Plug= miniature cap.Get the plug from fittings (piping fittingspipe comp.)2 ways to move fittings move OR dragNB: In order to stop termination inconsistency Fittings end components End of line Flow Direction: Label piping segment flow direction.

Text: Design Annotation Labels Item notes & Labels (Then fill in note text-properties)

Sensors, Pressure gauge Under InstrumentsDifferent types of links and most common: Connect to process

Electric line

Software link

Are found in Instrumentation Signal line.How to find the instruments?Instrumentation: Actuators

Gaps

...Disc single line where?Disc: Instrumentation Offline Without implied ComponentsDCS: Instrumentation Offline In system Functions.Arrows for electrical wires- From DesignNB: Dont leave an instrument without drawing code.Select all instruments by Ctrl, then modify in properties window.For instruments: change sequence no. , Measured variable and instrument type.Measured VariableInstrument Type

TE

PR

PSV

Breakers:Piping Segment breakerReducer:In fittings Diameter Change.1. Get reducer

2. Label

3. Info for label

4. Valves

5. Electrical lines

6. Processes

5 most common types of breakers:Diameter / Group / Insulation / Heat Tracing / MaterialWe have to always put the flow direction in:Piping pipe segments flow directionBall valve: always full port.How to link drawings to each others?Symbol Piping piping OPCs Off drawingLinking OPCsEng. Data editor (Top)Piping ok OPC OkComments from the Eng. In Alabama: Check valve: || always or

Arrows are not to be placed on end caps

Grid density always set at 0.05

Equipment name is ALWAYS LABEL not Note.

Instruments Symbol without implied components

FO? FC? Difference?

Drip Leg? Orthogonal Line?

Control angle valve: from instruments Valve Angle 2 way generic body angle

Valves controlled electrically from Instruments.

In reducers, larger size x smaller size

Function block placed as a flag?I/P function near valve instrument, its symbol is Convert Function T/R found in InstrumentFunctionConvert Function T/RWe put the value I/P in Properties/Instrument Function Value.Checking drawing digitally.Engineering data Each component Pipe Run.

Process line

Instrument

Equipment

In order to check the connect to process, we put Pipe Run Ok Connect to process.Where to get insulation from? Piping Labels Piping Segments.

Line number: Piping Labels Piping Segments