Product Information
Macro extensometer TC-EXMACRO
All data at ambient temperature. All rights reserved.
Description
Drive unit for sensor arms (required for use with temperature chamber)
Automatic L0adjustment (connection to CAN-BUS measurement module)
Order item TC-EXMACRO.001 TC-EXMACRO.002
TC-EXMACRO.H01 TC-EXMACRO.H02
Unit
Resolution
300mm sensor arms for ambient temperature 0.3 0.12 0.3 0.15 m
450mm sensor arms for small temperature chamber 0.45 0.18 0.45 0.225 m
600mm sensor arms for wide temperature chamber 0.6 0.24 0.6 0.3 m
Measurement range
300mm sensor arms for ambient temperature 80 80 75 (60)1 75 (60)1 mm
450mm sensor arms for small temperature chamber 120 120 112.5 (90)1 112.5 (90)1 mm
600mm sensor arms for wide temperature chamber 160 160 150 (120)1 150 (120)1 mm
L0Range 10 to 100 10 to 100 10 to 205 10 to 205 mm
Size
Width x Height x Depth 125 x 360 x 340 125 x 540 x 340 mm
Drag force < 0.05 < 0.05 < 0.05 < 0.05 N
Accuracy:Accuracy grade 1 according to EN ISO 9513
Here is required:
Measurement module: Incremental or
CAN-BUS and controller2
For use with a temperature chamber: drive unit (see below)
Drive unit for sensor arms and L0adjustment
Order item
TC-EXMACRO.DU2/
TC-EXMACRO.DU3
TC-EXMACRO.DU4/
TC-EXMACRO.DU5
Reduction-in-width monitor
1The value in brackets indicates the measurement path in the compression/flexure direction which differs only here from the one in tensile
direction2Only in connection with a materials testing machine of the Allround-Line with option TC-OPPLUS
Order item
TC-MOINCRC
TC-MOCANBU and TC-EXMACRO.CC1
TC-EXMACRO.DU2 or TC-EXMACRO.DU3
Order item
TC-EXMACWD.001
TC-EXMACWD.H01
TC-EXMACWD.002
TC-EXMACWD.H02
TC-EXMACWD.012
TC-EXMACWD.H12
TC-EXMACWD.003
TC-EXMACWD.H03
TC-EXMACWD.004
TC-EXMACWD.H043 Initial gauge length of the macro extensomter
Drive unit for reduction-in-width monitor with connection to CAN-BUS measurement module
and control unit
TC-EXMACWD.DU1/
TC-EXMACWD.DU2
Drive unit for reduction-in-width monitor
Meas. Clamping Specimen Meas. Init. gauge Resolution
lines pressure width thickness range length(1
With 4 0.1 m
mechanical 1.5 ... 2 10...15/ 0.01 m
switching 2 N 20...25 0...4 4...9 50 0.1 m
for different mm mm mm mm 0.01 m
specimen 1 0.1 m
widths 0.01 m
Swivelled-out 4 0.1 m
up to 90 0.5 ... 0.7 10...25 0...4 6 10 0.01 m
1 N mm mm mm mm 0.1 m
0.01 m