PhotoVoltaic General Catalog

Embed Size (px)

Citation preview

  • 7/26/2019 PhotoVoltaic General Catalog

    1/20

  • 7/26/2019 PhotoVoltaic General Catalog

    2/20

    photovoltaic generatordisconnection boxes

    22

  • 7/26/2019 PhotoVoltaic General Catalog

    3/20

    333Surge Protection for PV

    Introduction 4

    Protection of PV systems 5

    Surge Protection Range for PV system 6

    Surge Protection Panels for PV installations 10

    Surge Protection Panels for PV Plants 16

    Index

    BR09092- Document could be modified without notice

  • 7/26/2019 PhotoVoltaic General Catalog

    4/20

    photovoltaic generatordisconnection boxes

    4

    The company

    CITEL, a French company founded in 1937, has been manufacturing surge

    protection since 1945.

    CITEL offers a complete range of surge protection adapted to various

    networks including Low Voltage, Telecom, Data, Radiocom.

    Since 2005, CITEL has developed a range of surge protection and integrated

    enclosure solutions specically for the photovoltaic market.

    CITEL's mission is to bring high-performance solutions compliant with the

    worlds leading standards in order to insure the best effi ciency and reliability

    of your photovoltaic system.

  • 7/26/2019 PhotoVoltaic General Catalog

    5/20

    55Surge Protection for PV

    Protection of PV devicesagainsttransient overvoltages

    Surge Protectors for PV devices

    The photovoltaic installation can be exposed to

    overvoltages on different networks :

    -AC network: surge protectors are necessary,

    sometimes mandatory, for the 230V monophase

    network (or 3-phases 230/400V) on which the PV

    inverter is connected.

    - DC network: surge protectors are necessary,

    sometimes mandatory, on the continuous network

    in between the modules and the PV inverter.

    - Data Network : if the PV inverter is linked to

    data lines (transducers, sensors, supervision) surge

    protectors are sometimes required.

    Most of the solar module manufacturers offer a warranty

    of 20 years or more on their products. The cost of such

    devices is then calculated on this very long period.

    However those installations are very regularly exposed

    to lightnings and overvoltages, which can considerably

    reduce the desired life expectancy. The use of adaptedsurge protections is then highly recommended.

    Several aspects have to be considered to evaluate the risk

    "Lightning and Overvoltages" :

    The more the solar panel field is expanded, the more

    the risk of "lightning" issue is important.

    The risk is multiple : direct effect (lightning impact

    directly on the modules) and indirect effect (overvoltages

    on modules, on the converter/inverter and other

    connecions).

    When the Photovoltaic devices are located on industrial

    sites, the risk of operation overvoltages should be taken in

    account as well.

    The risks level is directly linked to the density of local

    lightning and the exposure of the lines.

  • 7/26/2019 PhotoVoltaic General Catalog

    6/20

    photovoltaic generatordisconnection boxes

    6

    Surge Protectors for PV installations - AC side

    Surge Protectors for Data Lines

    Surge protectors Type 1 and Type 2 AC

    Surge protection with pluggable module for Data line

    DS250VG - DS40 - DS240

    DLA

    Reference DS250VG DS40 DS240 DS215

    Type of surge protector Type 1 Type 2 Type 2 Type 2

    Location TGBT TGBTTGBT or close

    to a PV inverterclose to a PV

    inverter

    Low voltage network Un 230/400 Vac 230/400 Vac 230 Vac 230 Vac

    Max. operating voltage Uc 255 Vac 255 Vac 255 Vac 255 Vac

    Nominal discharge current In 30 kA 20 kA 20 kA 5 kA

    Max. discharge current Imax 70 kA 40 kA 40 kA 15 kA

    Lightning current (10/350) Iimp 25 kA - - -

    Protection level Up 1,5 kV 1,25 kV 1,25 kV 0.9 kV

    Reference for 1-phase network(TT, TN)

    DS252VG-300/G DS42-230/G DS240-230/G DS215-230/G

    Reference for 3-phase network(TT, TN)

    DS254VG-300/G DS44-230/G - -

    Dimensions (1-phase) 72 mm 36 mm 18 mm 18 mm

    References DLA-48D3 DLA-24D3 DLA-06D3

    Type of line PT100 4-20 mA RS485

    Operating DC voltage Un 48 Vdc 24 Vdc 6 Vdc

    Nominal discharge current In 5 kA 5 kA 5 kA

    Max. discharge current Imax 20 kA 20 kA 20 kA

    The connection of the PV to low voltages should be protected according to the Guide UTE

    C15-712 recommandation. Depending on the k ind of network, the presence of lightning rod or on primary

    existing surge protectors, CITEL proposes several solutions.

    The PV installation can be interconnected to different data networks (transducers, sensors, supervision..). In

    that case the use of adapted surge protectors on those networks is recommended.

    DS254VG-230/G

    DS44S-230/G

    DS240S-230/G

    DLA-24D3

  • 7/26/2019 PhotoVoltaic General Catalog

    7/20

    7Surge Protection for PV

    Surge Protectors for PV installations - DC side

    DS50PVSurge protection Type 2 with unpluggable modules for PV network

    Surge protection Type 1 for PV power supply

    DS60PV

    References DS50PV-500 DS50PV-600 DS50PV-800 DS50PV-1000

    Max. PV voltage Uocstc 500 Vdc 600 Vdc 800 Vdc 1000 VdcMax. operating voltage Ucpv 530 Vdc 680 Vdc 840 Vdc 1060 Vdc

    Protection Modes MC MC MC/MD MC/MC

    Nominal discharge current 8/20s In 20 kA 20 kA 20 kA 20 kA

    Max. discharge current 8/20s Imax 40 kA 40 kA 40 kA 40 kA

    Protection level Up 1,8 kV 2,5 kV 3 kV 3,6 kV

    Remote controlled version DS50PVS-500 DS50PVS-600 DS50PVS-800 DS50PVS-1000

    The DC input of the inverters should be protected according to the recommandations of the UTE C15-

    712 Guide. Citel has developped a whole range of products devoted to this application : DS50PV. This one

    proposes several solutions :

    DS50PV: standard solution using specic varistors, available in common or differential mode.

    DS50PV-.../G : version including a branch with gas tube linked to the ground, allowing the total

    suppression of leakage current. Protection in common and differential mode.

    When the installation is equipped with lightning rods, it is recommanded to use surge protectors specicallydesigned to dissipate a part of the direct impact of the lightning. For those cases, CITEL has developped the

    DS60PV series Type 1 surge protectors being able to take up 12.5 kA a pole for a 10/350s wave.

    DS50PV-.../GSurge protection Type 2 with unpluggable modules for PV network - without leakage current

    References DS50PV-500/G DS50PV-800/G DS50PV-1000/G

    Max. PV voltage Uocstc 500 Vdc 800 Vdc 1000 Vdc

    Max. operating voltage Ucpv 530 Vdc 840 Vdc 1060 Vdc

    Protection Modes MC/MD MC/MD MC/MC

    Nominal discharge current 8/20s In 20 kA 20 kA 20 kA

    Max. discharge current 8/20s Imax 40 kA 40 kA 40 kA

    Protection level Up 1,8 kV 3 kV 3,6 kV

    Remote controlled version DS50PVS-500/G DS50PVS-800/G DS50PVS-1000/G

    References DS60PV-500 DS60PV-1000

    Max. PV voltage Uocstc 500 Vdc 1000 Vdc

    Max. operating voltage Ucpv 550 Vdc 1100 Vdc

    Protection Modes MC MC

    Nominal discharge current 8/20s In 40 kA 40 kA

    Lightning current 10/350s Iimp 12,5 kA 12,5 kA

    Protection level Up 1,7 kV 2,4 kVRemote controlled version DS60PVS-500 DS60PVS-1000

    DS50PV-1000

    DS50PVS-500

    DS60PV-500

  • 7/26/2019 PhotoVoltaic General Catalog

    8/20

    photovoltaic generatordisconnection boxes

    8

    +

    AC

    DC

    -

    to

    Vto

    V

    L

    ND

    DDR

    S

    CPdc

    Pbt

    Surge protection panels for PV installations

    Main features

    Panels for AC side and DC of the PV inverters.

    Compliant with the UTE C15-712 guide.

    High resistance panels for use in all conditions.

    Easy installation and access for a best maintenance.

    Transparent cover for quick inspection.

    Switching.

    PV voltage up to 1000Vdc.

    Fuse protection (panels > 3 strings).

    Specic version on demand.

    Disconnecting switch handle with padlock.

    Protection princip le by panel as defined by UTE C15-712

    In compliance with the UTE C15-712 guide, CITEL proposes a complete

    range of panel integrated solutions tha include surge protectors, over

    current protection, differential circuit breaker, switchning and connection.

    Those panels are designed to be installed on AC and PV access of the

    photovoltaic inverter. Numerous conguration are available

    Pbt : 1-phase surge protector Type 2D : External disconnector of the surge protectorDDR : Differential breaker 25A/30 mA

    Pdc : DC surge protector Type 2 for PV (DS50PV)S : DC switchC : Terminal connection board for strings

    towards-TGBT

    CPV240

    AC Surge protector panel+ differential breaker Photovoltaic

    inverter

    CPV50DC surge protector panel+ switching+ connection strings

  • 7/26/2019 PhotoVoltaic General Catalog

    9/20

    9

    D

    DS240-230/G

    NL

    NL

    NL

    NL

    NL

    Type2

    Imax40kA

    C25 3 0mA C20

    Test

    onduleurinverter

    =~

    Surge Protection for PV

    The CPV240 surge protector panel are designed to protect against the

    overvoltages caused by lightning, the low voltage side of the PV inverter

    linked to the low voltage network. They integrate the following functions :

    Protection against the overvoltages (surge protector CITEL DS240)

    compliant with the NF EN 61643-11standard

    Line and differential breaker

    Connection to network

    The CPV240 panels are available for 1-phase 230V network and several line

    currents and comply with the UTE C15-712 Guide requirement about the

    photovoltaic installations linked to low voltage network.

    Specic versions by request.

    Electrical diagram

    Surge protection panel for PV inverter - AC side

    CPV240

    AC surge protector panel for

    1-phase PV inverter

    Characteristics CPV240-230-xx-DDR

    Network Un 230 V single phase

    Max. current (xx) 16 - 20 - 25 - 32 A

    Connection to network (Max. cable cross-section)

    4 mm max

    Safety DS240-230/G

    Thermal disconnector inside the surge protector

    Disconnection indicator indicator on the surge protector

    Overvoltage protection by circuit-breaker in the surgeprotector branch

    Overcurrent protection by line circuit-breaker(16 to 32 A rating)

    Protection against indirect contact by diff. circuit breaker 30 mAType 2 SPD DS240-230/G

    Max. operating voltage Uc 255 Vac

    Nominal discharge current In 20 kA

    Maximum discharge current Imax 40 kA

    Protection level Up 1.5/1.25 kV

    Mechanical characteristics

    Protection class IP55

    Dimensions (H x L x P) mm 198 x 255 x 108

    Housing material Polycarbonate UL 94 V0

    Switchgear access Transparent door

    Cable path by cable gland

    Towards

    TGBT

    Towards

    PV inverter

    Breaker 25 A

    + differential 30 mALN

    PE

    vers Terre de l'installation

    TGBTRseau230 V

  • 7/26/2019 PhotoVoltaic General Catalog

    10/20

    photovoltaic generatordisconnection boxes

    10

    -

    -PE

    +

    +

    DS50PV

    -+

    CPV range PV surge protector panel

    50 Type 260 Type 1

    Number of Strings

    CPV50-1000-3ST/FUSPD

    Max. PV DC voltage (Uocstc)

    - with DC switch, without fuse (standard)

    NS without DC switch

    FUS10 with fuse on line (ex: 10 A)

    500 500Vdc600 600Vdc

    800 800Vdc

    1000 1000Vdc

    3ST 3 strings 8ST 8 strings

    4ST 4 strings 10ST 10 strings

    6ST 6 strings 14ST 14 strings

    Breakers and Fuses

    The CPV50 surge protection panels are designed to protect, against

    overvoltages due to lightning, the DC part of the PV inverters. They

    integrate the following functions :

    Protection against overvoltages (surge protector CITEL DS50PV)

    compliant with NF EN 61643-11 standard

    Switching

    Line fuse on string (panels > 3 strings)

    Connection of the stringsThe panels CPV50 are available with the voltage Uocstc 500, 600 800

    and 1000 Vdc and for several short circuits current (Iscstc). They comply

    with the requirements of the UTE C15-712 Guide on the Photovoltaic

    installations connected to AC network.

    The panels have a protection indice and a resistance to the impacts

    adapted to rough use conditions.

    Specic version are available on demand.

    Surge protection panel for PV inverter - DC side

    Reference system

    CPV50

    Electrical diagram

    vers

    onduleur PVvers

    strings

    sectionneur

    Fusible

    (option)

  • 7/26/2019 PhotoVoltaic General Catalog

    11/20

    1111

    Red/Rouge: to replace

    DS50PV-500

    +

    U c 5 3 0 Vd cU n 5 0 0 Vd c

    Parafoudre DC

    SurgeProtector

    U p 2 .2 kV

    In 20kA

    ImaxT2 40kA

    Red/Rouge: to replace

    DS50PV-500

    -

    U c 5 3 0 Vd cU n 5 0 0 Vd c

    Parafoudre DC

    SurgeProtector

    U p 2 .2 kV

    In 20kA

    ImaxT2 40kA

    M16M16 M16

    M12

    M12 M12

    M12 M12 M12

    onduleurinverter

    =~

    modules+ in

    modules- in+

    out-

    out

    Surge Protection for PV

    CPV50-500-3ST

    CPV50-600-3ST

    3 strings surge protection panel

    500 Vdc - Switch

    Characteristics CPV50-500-3ST CPV50-600-3ST

    Number of strings 3 3

    Max. voltage PV Uocstc 500 Vdc 600 Vdc

    Max. current Iscstc 20 A 20 A

    Connection to network (Max. cable cross-section)

    6,5 / 10 mm2 6,5 / 10 mm2

    Switching yes yes

    Fuse protection by string no no

    Type 2 SPD DS50PV-500 DS50PV-600

    Max. operating voltage Ucpv 530 Vdc 680 Vdc

    Nominal discharge current In 20 kA 20 kA

    Maximum discharge current Imax 40 kA 40 kA

    Protection level Up 1.8 kV 2,5 kV

    Mechanical characteristics

    Protection level IP65 IP65

    Dimensions (H x L x P) mm 305 x 225 x 125 305 x 225 x 125

    Housing material ABS PC ABS PC

    Knob type Lockable Lockable

    PV Surge Protection Panels

  • 7/26/2019 PhotoVoltaic General Catalog

    12/20

    photovoltaic generatordisconnection boxes

    12

    Red/Rouge: to replace

    DS50PV-800

    +

    U c 8 4 0 Vd c

    Un 8 0 0 V d c

    Parafoudre DCSurgeProtector

    Up 3kV

    I n 2 0k A

    ImaxT2 40kA

    Red/Rouge: to replace

    DS50PV-800

    U c 8 4 0 Vd c

    Un 8 0 0 V d c

    Parafoudre DCSurgeProtector

    Up 3kV

    I n 2 0k A

    ImaxT2 40kA

    Red/Rouge: to replace

    DS50PV-800

    -

    Uc 8 4 0 V d c

    Un 8 0 0 V d c

    Parafoudre DCSurgeProtector

    Up 3kV

    I n 20k A

    ImaxT2 40kA

    M16 M16 M16

    M12

    M12 M12

    M12 M12 M12

    onduleurinverter

    =~

    modules+ in

    modules- in+

    out

    -

    out

    PV Surge Protection Panels

    CPV50-800-3ST

    CPV50-1000-3ST

    3 strings surge protection panel

    800 and 1000 Vdc - 25 A

    Switch

    Characteristics CPV50-800-3ST CPV50-1000-3ST

    Number of strings 3 3

    PV maximum voltage Uocstc 800 Vdc 1000 Vdc

    Max. current Iscstc 25 A 25 A

    Connection to network (Max. cable cross-section)

    6,5 / 10 mm2 6,5 / 10 mm2

    Switching yes yes

    Fuse protection by string option option

    Parafoudre Type 2 DS50PV-800 DS50PV-1000

    Max. operating voltage Ucpv 840 Vdc 1060 Vdc

    Nominal discharge current In 20 kA 20 kA

    Maximum discharge current Imax 40 kA 40 kA

    Protection level Up 3 kV 3,6 kV

    Mechanical characteristics

    Protection class IP65 IP65

    Dimensions (H x L x P) mm 305 x 225 x 125 305 x 225 x 125

    Housing material ABS PC ABS PC

    Knob type Lockable Lockable

  • 7/26/2019 PhotoVoltaic General Catalog

    13/20

    1313

    10.3 x38

    PV1000Vdc

    DONOTOPERATEUNDERLOAD

    10.3 x38

    PV1000Vdc

    DONOTOPERATEUNDERLOAD

    10.3 x38

    PV1000Vdc

    DONOTOPERATEUNDERLOAD

    10.3 x38

    PV1000Vdc

    DONOTOPERATEUNDERLOAD

    10.3 x38

    DONOTOPERATEUNDERLOAD

    10.3 x38

    PV1000Vdc

    DONOTOPERATEUNDERLOAD

    10.3 x38

    PV1000Vdc

    DONOTOPERATEUNDERLOAD

    10.3 x38

    PV1000Vdc

    UNDERLOAD

    Red/Rouge: to replace

    DS50PV-1000

    +

    U c1 0 6 0 Vd c

    Un 1000 Vdc

    Parafoudre DCSurgeProtector

    Up 3V

    I n 2 0k A

    ImaxT2 40kA

    Red/Rouge: to replace

    DS50PV-1000

    U c1 0 6 0 Vd c

    Un 1000 Vdc

    Parafoudre DCSurgeProtector

    Up 3V

    I n 2 0k A

    ImaxT2 40kA

    Red/Rouge: to replace

    DS50PV-1000

    -

    U c1 0 6 0 Vd c

    U n 1 0 0 0 Vd c

    Parafoudre DCSurgeProtector

    Up 3V

    I n 2 0k A

    ImaxT2 40kA

    M16 M16 M16M 1 2 M 1 2

    M 1 2 M 1 2

    M12M12

    M12 M12

    onduleurinverter

    =~

    modules+ in

    modules- in+

    out-

    out

    Surge Protection for PV

    PV Surge Protection Panels

    CPV50-1000-4ST/FUS10

    4 strings surge protection panel

    1000 Vdc - 25 A

    Switch

    Fuse

    Characteristics CPV50-1000-4ST/FUS10

    Number of strings 4

    Max. voltage PV Uocstc 1000 Vdc

    Max. current Iscstc 25 A

    Connection to network (Max. cable cross-section)

    6,5 / 10 mm2

    Switching yes

    Fuse protection by string 10 A

    Type 2 SPD DS50PV-1000

    Max. operating voltage Ucpv 1060 Vdc

    Nominal discharge current In 20 kA

    Max discharge current Imax 40 kA

    Protection level Up 3,6 kV

    Mechanical characteristics

    Protection class IP65

    Dimensions (H x L x P) mm 285 x 385 x 185

    Housing material GR Polyester/PC

    Knob type Lockable

  • 7/26/2019 PhotoVoltaic General Catalog

    14/20

    photovoltaic generatordisconnection boxes

    14

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    Red/Rouge: to replace

    DS50PV-1000

    +

    U c 1 0 6 0 V d c

    U n 1 0 0 0 V d c

    Parafoudre DCSurgeProtector

    U p 3 .6 V

    I n 2 0k A

    ImaxT2 40kA

    Red/Rouge:to replace

    DS50PV-1000

    U c 1 0 6 0 V d c

    U n 1 0 0 0 V d c

    Parafoudre DCSurgeProtector

    U p 3 . 6V

    I n 2 0k A

    ImaxT2 40kA

    Red/Rouge: to replace

    -

    U c 1 0 6 0 V d c

    U n 1 0 0 0 V d c

    Parafoudre DCSurgeProtector

    U p 3 .6 V

    I n 2 0k A

    ImaxT2 40kA

    M20 M20 M20M12 M12 M12

    M12 M12 M12

    M12 M12 M12

    M12 M12 M12

    onduleurinverter

    =~

    modules+ in

    modules- in+

    out-

    out

    CPV50-1000-6ST/FUS10

    6 strings surge protection panel

    1000 Vdc - 25 A

    Switch - Fuses

    Characteristics CPV50-1000-6ST/FUS10

    Number of strings 6

    Max. voltage PV Uocstc 1000 Vdc

    Max. current Iscstc 25 A

    Connection to network (Max. cable cross-section)

    6,5 / 10 mm2

    Switching yes

    Fuse protection by string 10 A

    Type 2 SPD DS50PV-1000

    Max. operating voltage Ucpv 1060 Vdc

    Nominal discharge current In 20 kA

    Maximum discharge current Imax 40 kA

    Protection level Up 3,6 kV

    Mechanical characteristics

    Protection class IP65

    Dimensions (H x L x P) mm 285 x 570 x 185

    Housing material GR Polyester/PC

    Knob type Lockable

    PV Surge Protection Panels

  • 7/26/2019 PhotoVoltaic General Catalog

    15/20

    15

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    10.3x38

    PV1000Vdc

    DONOTOPERATE

    UNDERLOAD

    OFF

    ON

    125A 4P

    UeIe

    48V125A/1p*

    110V125A/2p*

    220V125A/3p*

    400V125A/4p*

    600V80A/4p*

    800V63A/4p*

    55DC4014INTERRUPTORSECCIONADOR

    Switch-disconnec tor*poles in ser ies

    Red/Rouge:toreplace

    DS50PV-800

    +Uc

    840Vdc

    Un

    800Vdc

    ParafoudreDC

    SurgeProtector

    Up

    3kV

    In

    20kA

    Imax

    T2

    40kA

    Red/Rouge:toreplace

    DS50PV-800

    Uc

    840Vdc

    Un

    800Vdc

    ParafoudreDC

    SurgeProtector

    Up

    3kV

    In

    20kA

    Imax

    T2

    40kA

    Red/Rouge:toreplace

    DS50PV-800

    -

    Uc

    840Vdc

    Un

    800Vdc

    ParafoudreDC

    SurgeProtector

    Up

    3kV

    In

    20kA

    Imax

    T2

    40kA

    M20 M20 M20M12 M12 M12M12 M12 M12 M12 M12 M12M12 M12 M12

    onduleurinverter

    =~

    modules+ in

    modules- in+

    out-

    out

    SORTIEOUTPUT

    SORTIEOUTPUT

    TOUJOURS SOUS TENSIONALWAYSUNDERVOLTAGE800V

    ENTRE

    INPUT

    ENTRE

    INPUT

    Surge Protection for PV

    CPV50-800-6ST/FUS10

    6 strings surge protection panel

    800 Vdc - 63 A

    Switch - Fuses

    Characteristics CPV50-800-6ST/FUS10

    Number of strings 6

    Max. voltage PV Uocstc 800 Vdc

    Max. current Iscstc 63 A

    Connection to network (Max. cable cross-section)

    6,5 / 10 mm2

    Switching yes

    Fuse protection by string 10 A

    Type 2 SPD DS50PV-800

    Max. operating voltage Ucpv 840 Vdc

    Nominal discharge current In 20 kA

    Maximum discharge current Imax 40 kA

    Protection level Up 3 kV

    Mechanical characteristics

    Protection class IP65

    Dimensions (H x L x P) mm 285 x 570 x 185

    Housing material GR Polyester/PC

    Knob type Lockable

    PV Surge Protection Panels

  • 7/26/2019 PhotoVoltaic General Catalog

    16/20

    photovoltaic generatordisconnection boxes

    16

    Surge protection panels for Photovoltaic farms

    Main

    Features

    High resistance enclosure for

    use in all conditions.

    Easy installation with simple

    access for an optimized

    maintenance.

    Transparent cover for quick

    inspection.

    Switching up to 125 A.

    PV voltage up to 1000Vdc.

    Fuse protection.

    Specic version by request.

    The panels devoted to the junction, switching and protection of Photovoltaic Power Plants are designed for specic

    conditions of use, performance and maintenance

  • 7/26/2019 PhotoVoltaic General Catalog

    17/20

  • 7/26/2019 PhotoVoltaic General Catalog

    18/20

  • 7/26/2019 PhotoVoltaic General Catalog

    19/20

    1919Surge Protection for PV

    Determine your specific PV panel

    Requested Features

    Switching

    Surge protector

    Type 2 Type 1

    Fuse protection

    500V

    800V

    600V

    1000V

    Max. voltage(Uocstc)

    15A

    40A

    80A

    20A

    50A

    125A

    25AMax. current (Iscstc) :

    Quantity

    Number of strings

    Comments :

    Information

    Company Fax

    Adress E-mail

    WebCity/Zip code

    PhoneLast, First Name

    Contact our technicalservice for your

    personalized panel

    [email protected]

    fax : 01 41 23 50 39

    MC Connectors

    sans

  • 7/26/2019 PhotoVoltaic General Catalog

    20/20

    CITEL-2CP2 rue Troyon

    92316 Svres CEDEX - France

    Tel +33 (1) 41 23 50 23

    Fax +33(1) 41 23 50 39

    Email : [email protected]

    Web : www.citel2cp.com

    CITEL GmbHAlleestrasse 144, Tor 5

    D-44793 Bochum - Allemagne

    Tel +49 234 54 72 10

    Fax +49 234 54 72 199

    Email : [email protected]

    Web : www.citel2cp.de

    CITEL Inc11381 Interchange Circle South

    FL 33025 Miramar - USA

    Tel +1 954 430 6310

    Fax +1 954 430 7785

    Email : [email protected]