Dr. Sahar Abd El Moneim Moussa 1
Pharos UniversityEE-385
Electrical Power & Machines“Electrical Engineering Dept”
Prepared By:Dr. Sahar Abd El Moneim Moussa
Dr. Sahar Abd El Moneim Moussa 2
Three-Phase System
Dr. Sahar Abd El Moneim Moussa 3
Balanced Three-Phase SystemBalanced three-phase voltage consists of three sinusoidal voltage having the same amplitude & frequency but are out of phase with each other exactly by 120o
Dr. Sahar Abd El Moneim Moussa 4
3 Phase Voltages in Time DomainVa = Vm Sin ωtVb = Vm Sin (ωt-120)Vc = Vm Sin (ωt-240)
Phase
(a)Phas
eb
Phase (c)
Dr. Sahar Abd El Moneim Moussa 5
3-Phase Voltages in Terms of Phasors
Va = Vm ∠0Vb = Vm ∠-120Vc = Vm ∠-240 = Vm ∠120
Dr. Sahar Abd El Moneim Moussa 6
Types of Connections in 3-phase system
Wye”Y” Delta”∆”
Dr. Sahar Abd El Moneim Moussa 7
Wye Connection “Y”Wye Connection: “Y”For Y circuit:
Iline = Iphase
Dr. Sahar Abd El Moneim Moussa 8
Delta Connection “∆”For Delta Circuit:Eline = Ephase
Dr. Sahar Abd El Moneim Moussa 9
Relationship between three-phase delta-connected and wye connected impedance
Wye connected load
Delta connected load
Dr. Sahar Abd El Moneim Moussa 10
Four Different Configurations for the three-phase source and loads Connections
Load Source
Dr. Sahar Abd El Moneim Moussa 11
Power in 3-φ System• P(total) = • Q(total) =
S(total) =
Dr. Sahar Abd El Moneim Moussa 12
Example 1:A balanced three-phase Y-connected generator with positive sequence has an impedance of 0.2 +j0.5 / and internal voltage 120V/ feeds a -connected load through a distribution line having an impedance of 0.3 +j0.9 /. The load impedance is 118.5+ j85.8 /. Use the a phase internal voltage of the generator as a reference.A. Construct the single-phase equivalent circuit of the 3-
system.B. Calculate the line currents IaA , IbB and IcC.C. Calculate the phase voltages at the load terminals.D. Calculate the phase currents of the load.E. Calculate the line voltages at the source terminals.F. Calculate the complex power delivered to the -
connected load.
Dr. Sahar Abd El Moneim Moussa 13
Solution:A. The load impedance of the Y equivalent is
Dr. Sahar Abd El Moneim Moussa 14
B. The a-phase line current is
A.Therefore,
IbB=2.4-156.87 A.IcC= 2.483.13 A.
C. because the load is - connected, the phase voltages are the same as the line voltages. To calculate the line voltages,
VA=(39.5 + j28.6)(2.4-36.87) = 117.04-0.96
Dr. Sahar Abd El Moneim Moussa 15
The line voltage VAB is
= 202.72 29.04VTherefore,
VBC=202.72 -90.96 VVCA= 202.72 149.04 V
D. The phase currents of the load will be,
= 1.39 -6.87 A.
Dr. Sahar Abd El Moneim Moussa 16
Therefore, IBC=1.39-126.87 AICA=1.39113.13 A
E. The line voltage at the source terminals will be,Va=(39.8 + j29.5) (2.4-36.87)
=118.9 -0.32 V.
The line voltage will be = 205.9429.68 V.
Therefore ,Vbc=205.94 -90.32 V.Vca= 205.94149.68 V.
Dr. Sahar Abd El Moneim Moussa 17
F. The total complex power delivered to the load will be,
V=VAB= 202.72 29.04 V.I=iAB=1.39-6.87 A.
Therefore,ST= 3 (202.72 29.04) (1.396.87)
= 682.56 +j 494.21 VA