1/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
ACR Systems
Bottle Logger Model: BTL-100 Measures: Temperature Description: Logger cased in anodized aluminum capable of underwater operation. 0.71 inches in diameter, and 5 inches long. Will fit most bottlenecks. Sensor: Range (Accuracy): - Temp: - 40° to 185° F (± 0.3° F) Resolution: 8 bit Memory/Records: 32K Related Application Note(s): ACR Trendreader Software
ACR Systems
External Temp/RH Sensor for ACR Model: EH-010A Measures: Temperature, Relative Humidity Description: External temperature and relative humidity sensor with 3 foot lead length. For use with the ACR SmartReader 2. Sensor: Range (Accuracy): - RH: 10% to 95% (± 5%) - Temp: - 4° to 104° F
ACR Systems
Power Watch Model: PWV 001 Measures: Voltage Disturbances Description: This data logger records voltage disturbance events including surges, sags, and frequency variation. It is plugged into a 110V receptacle to monitor system voltage. The device has a PC optical interface cable for data transfer and real time readings. Sensor: Range (Accuracy): - Surge, Sag & Outage of Voltage: 0 to 200 V rms (± 1% + resolution) - Voltage Impulse: 50 to 2500 V Peak (± 10% readings + resolution) - frequency: 45 to 65 Hz Resolution: 1 v rms, 1 cycle, 0.1 Hz Memory/Records: 4000 events
ACR Systems Smart Reader 2 Model: SR-002 Measures: Temperature, Relative Humidity Description: Temperature and relative humidity logger with four channels; one internal temperature, one internal RH, two channels for optional external temperature and RH sensors. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in.
2/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Sensor: Range (Accuracy): - Internal Temp: - 40° to 158° F (± 0.3° F) - Internal RH: 0% to 95% (± 4%) Resolution: 8 bit Memory/Records: 32,768 readings Related Application Note(s): ACR Trendreader Software
ACR Systems
Smart Reader 3 Model: SR-003 Measures: Temperature, AC Current Description: Three channel AC current logger with an internal temperature sensor. Compatible with Amprobe current probes. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in. Sensor: Range (Accuracy): - Internal Temp: - 40° to 158° F (± 0.2° to 0.3° F) Resolution: 8 bit Memory/Records: 32,768 readings Related Application Note(s): ACR Trendreader Software Using Current as Proxy for Power
ACR Systems
Smart Reader 7 Model: SR-007 Measures: Temperature, DC Voltage and DC Milliamps Description: Process signal logger with eight channels: one internal temperature, six DC voltage channels and one DC milliamp channel. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in. Sensor: Range (Accuracy): - Temp: - 40° to 158° F (± 0.3° F) - Volts DC: 0 to 2.5 VDC (± 1% full scale) - Volts DC: 0 to 5.0 volts DC (± 1% full scale) - Volts DC: 0 to 10.0 volts DC (± 1% full scale) - Millivolts DC: 0 to 200 millivolts DC (± 1% full scale) - Milliamps DC: 0 to 25 milliamps DC (± 1% full scale) Resolution: 8 bit Memory/Records: 32,768 readings Related Application Note(s): ACR Trendreader Software
ACR Systems Smart Reader 9 Model: SR-009
3/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: Temperature, Position, Status Description: Two channel pulse logger with internal temperature sensor. Logger is used to record externally generated pulse signals or dry contact closures. Tool adapts to various pulse frequencies. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in. Sensor: Range (Accuracy): - internal temp: - 40° to 158° F (± 0.2°-0.3° F) - pulse: 32 to 128 pulse/sec Resolution: 8 bit Memory/Records: 32,768 records Related Application Note(s): ACR Trendreader Software
ACR Systems
Smart Reader Plus 10 Model: SRP-010-128K Measures: Temperature Description: Four channel temperature datalogger with one internal thermistor and three external channels for use with RTD temperature probes. Uses 2, 3, and 4-wire RTDs. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in. Sensor: Range (Accuracy): - Internal Temp: - 40° to 158° F (± 0.2° to 0.3° F) Resolution: 12 bit Memory/Records: 128K Related Application Note(s): ACR Trendreader Software
ACR Systems
Smart Reader Plus 2 Model: SRP-2 Description: Temperature and relative humidity logger. 128 KB mem., 12 bit Sensor: Range (Accuracy): 0 to 95 % RH (non-condensing) +/- 3% RH from 10 to 90 % RH Resolution: 12 Bit Memory/Records: 128 KB Related Application Note(s): ACR Trendreader Software
ACR Systems Smart Reader Plus 3 Model: SRP-003 Measures: Temperature, Current and DC Voltage Signal Description: Eight channel data logger; one internal temperature sensor, four AC current, and three DC voltage channels. Compatible with Amprobe clamp-on current transducers. Logger uses a PC serial
4/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in. Sensor: Range (Accuracy): - Internal Temp: - 40° to 158° F (± 0.3° F) - DC Voltage: 0 to 5 VDC (± 0.5% of full scale) Resolution: 12 bit Memory/Records: 21,500 readings Related Application Note(s): ACR Trendreader Software Using Current as Proxy for Power
ACR Systems
Smart Reader Plus 4 Model: SRP-004 Measures: Pressure and temperature. Description: Pressure and temperature logger (used for very precise low differential pressure measurements). Sensor: Range (Accuracy): -40 to 158 F operating temperature range +/-0.05"for.5",1.0" and 2.0" ranges- calibrated +/-1.0" for5.0" and 10.0" ranges- calibrated Thermal : +/-0.5%FS(over compensated range) Memory/Records: 32 KB
ACR Systems
Smart Reader Plus 4 LPD Model: SRP-004-LPD-10-32K Measures: gauge and differential pressures plus/minus 10"WC Description: differential pressure and temperature logger Sensor: Range (Accuracy): plus/minus 10"WC Resolution: 12 bit Memory/Records: 32Kb Related Application Note(s):
ACR Systems
Smart Reader Plus 6 Model: SRP-006-1.5M 7 Measures: Temperature Description: Eight channel logger with one internal temperature channel, and seven thermocouple input channels. Uses ACR thermocouple wires, or any J, K, S, T, and E type thermocouples. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in. Sensor: Range (Accuracy): - Internal Temp: - 40° to 158° F (± 0.2 to 0.3° F)
5/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Resolution: 12 bit Memory/Records: 1,048,000 readings Related Application Note(s): ACR Trendreader Software
ACR Systems
Smart Reader Plus 7 Model: SRP 007-128K Measures: Temperature, Voltage and Current Process Signals Description: Process signal logger with eight channels: one internal temperature, six DC voltage channels and one DC milliamp channel. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.2 in x 2.9 in x 0.9 in. Sensor: Range (Accuracy): - Temp: - 40° to 158° F (± 0.3° F) - Volts DC: 0 to 2.5 VDC (± 0.5% full scale) - Volts DC: 0 to 5.0 volts DC (± 0.5% full scale) - Volts DC: 0 to 10.0 volts DC (± 0.5% full scale) - Millivolts DC: 0 to 200 millivolts DC (± 0.5% full scale) - Milliamps DC: 0 to 25 milliamps DC (± 0.5% full scale) Resolution: 12 bit Memory/Records: 87,000 readings Related Application Note(s): ACR Trendreader Software
Advanced Test Products (Amprobe)
Amprobe CT for ACR Smart Reader 3 Model: A60FL and A70FL Measures: Current Description: Current transducer for ACR Smart Reader 3 with variable ranges. Internal diameter of the A60FL clamp is 1" and of the A70FL clamp is 2". Sensor: Range (Accuracy): - Current model A60FL: 0 to 5 amps, 0 to 25 amps, 0 to 100 amps and 0 to 250 amps (± 3% F.S.) - Current model A70FL: 0 to 10 amps, 0 to 50 amps, 0 to 250 amps and 0 to 500 amps (± 3% F.S.) Compatible Data Loggers: ACR SmartReader 3 ACR SmartReader Plus 3
AEMC AC/DC Current Probe Model: MR 521 Measures: AC or DC Amperage Description: Hall Effect current transducers switchable between 150A and 1500A with a millivolt output signal. Sensor: Range (Accuracy):
6/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- AC or DC Current: 0.2 to 1500 amps (± 1.5% to 4% of reading) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger Pace XR5 Logger
Airometrix
Compressed Air Flow Meter Measures: Compressed Air Flow Description: Analog compressed air flow meter measures the delivery of free air of an air compressor over a range of pressures. By opening various fixed orifices, a known load is imposed upon an air compressor allowing accurate and repeatable flow measurements. Model LP50 is used for compressors up to 50 hp and model LP07 is used for compressors up to 350 hp. Sensor: Range (Accuracy): - Flow (model LP50) : Max flow 205 cfm - Flow (model LP07): Max flow 1600 cfm
All-Test Pro
Motor circuit analyzer Model: All-Test IV Pro 2000 Measures: Resistance: 1 to 999 O 1, Impedance: 1 to 999 O 2, Inductance: 1 to 9999mH 3, Phase Angle: 9-90 degrees, Current/Freq Resp (I/F):0-99%, Capacitance: 0.2 - 200 µF Description: Hand-held motor analyzer. Used for motor fault detection (winding, rotor and air gap) for induction, synchronous, servo, DC and other motor types. Sensor: Range (Accuracy): +-1% for all parameters except as noted below Phase Angle- +-1 degree Current/Frequency Response (I/F) +-1 digit Capacitance- +-5% Insulation Resistance- +-5%
Alnor
AVM430 and AVM430-A Air Velocity Meter Model: AVM430, AVM430-A Measures: Air Velocity, Temperature Description: Handheld Air Velocity and Temperature meter. Type A has articulated probe, interval logging capability. Calculates flow rate if duct size is provided. 12,700 data samples maximum storage Sensor: Range (Accuracy): velocity: ±3% of reading or ±3% FPM, whichever is greater temperature: ±0.5ºF Resolution: 0 - 6000 fpm, 0 - 200º F Memory/Records: 12,700
7/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Alnor
AXD620 Micromanometer Model: AXD620 Description: Measures differential and static pressure. Calculates and displays velocity when using a Pitot tube. Calculates volumetric flow rate in duct from velocity and user-input duct size and shape. Records data points in duct traverse using sampling function. Data logging with time and date stamp. Programmable K factors. Sensor: Range (Accuracy): Static / Differential Pressure: Range1: -15 to +15 in. H2O Accuracy: ±1% of reading ±0.005 in. H2O Resolution: 0.001 in. H2O
Alnor
Electronic Balometer - APM150 Model: APM150 Measures: Air Flow Description: Meter measures supply or exhaust airflow from HVAC diffusers and grilles. The hood reconfigures for several standard size diffusers: 2'x2', 1'x4', 2'x4' and 4'x4'. The meter has an LCD readout for instantaneous display of readings. Sensor: Range (Accuracy): - Supply Air Flow: 50 to 2000 cfm ( ±3% reading + 7 cfm) - Exhaust Air Flow: 50 to 2000 cfm (±4% reading + 7 cfm)
Alnor
Electronic Balometer - EBT721 Model: EBT721 Measures: Air Flow Description: Meter measures airflow from HVAC diffusers and grilles. Inclues a 2'x'2 flow capture hood. The meter has an LCD readout for instantaneous display of readings. Sensor: Range (Accuracy): 25 to 2,500 cfm ( ±3% reading + 7 cfm)
Alnor
Hydromanometer HM670 Model: HM670 Measures: liquid pressure in feet WC (Head) Description: Portable hydronic manometer measures differential or gage pressure. Used to balance heating and cooling systems or to check pump performance. Compatible with air for high pressure air measurements. Sensor: Range (Accuracy): - Pressure: 0 to 300 psi or 0 to 8303 inches H2O ( ± 1%of reading or ± 0.036 psi for 0-250 psi)
8/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Resolution: 0.001 psi
Alnor
Hydromanometer HM680 Model: HM680 Measures: liquid pressure in feet WC (Head) Description: Portable hydronic manometer measures differential or gage pressure. Used to balance heating and cooling systems or to check pump performance. Compatible with air for high pressure air measurements. Sensor: Range (Accuracy): - Pressure: 0 to 300 psi or 0 to 8303 inches H2O - Flow: 0 - 9999GPM Resolution: 0.001 psi
Alnor
Micromanometer AXD560 Model: AXD560 Measures: Air Pressure Description: Micromanometer that measures pressure and calculates velocity and volumetric air flow. Meter has digital display for instantaneous readings and data logging capability. Stored data can be viewed on the instrument display or downloaded to a PC via an RS232 serial cable. Sensor: Range (Accuracy): - Pressure: -15 to +15 in. H2O (± 1% of reading ± 0.005 in. H2O) - Velocity: 250 to 15,500 ft/min (± 1.5% of reading at 2,000 ft/min) Resolution: 0.0005 in. H2O Memory/Records: 1000 Samples
Alnor
Omnidirectional Air Velocity Transducer Model: AVT 75-300 Measures: Air Velocity Description: Omnidirectional air velocity transducer with 12" probe and selectable range. Accurate at very low velocities. Output signal is user selectable between 0 to 5 volts, 0 to 10 volts, 1 to 5 volts, 2 to 10 volts, 0 to 20 milliamp, and 4 to 20 milliamps. Sensor: Range (Accuracy): - Air Velocity: 10 to 500 fpm (± 3% + 1% of selected full scale) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger Pace XR5 Logger
9/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Ametek
Dual Function Digital Tachometer Model: 1726 Measures: Position, Status Description: Meter for contact and non-contact measurement of rotational and linear motion. Digital display with eight characters and one floating decimal point. Holds four memory points; last, minimum, maximum, and average. Sensor: Range (Accuracy): - Non-Contact Rotational Speed: 6.0 to 99,999 revolutions/minute (± 0.25%) - Contact Rotation Speed: 6.0 to 20,000 revolutions/minute (± 0.25%) - Linear speed: 2.0 to 3,300 feet/minute (± 0.25%)
Amprobe (ATP)
Current Tracer Model: CT326, CT326B, CT326F Measures: Current Description: Hand-held circuit tracing device for locating and tracing circuit breakers and hot and neutral conductors without turning off power or interrupting electronic equipment. Can be used to identify energized circuits or trace circuits from the receptacle or lighting fixture to the electrical panel. Sensor: Range (Accuracy): - Voltage: 6 to 300 volts
Architectural Energy Corp.
12 inch Temperature Probe Model: Temp-02-2-t05-016 Measures: Temperature Description: Air duct temperature sensor for use with the AEC MicroDataLogger. 12 inch temperature probe with 16 foot long cable and an attached prewired MicroDatalogger module. Sensor: Range (Accuracy): - Temperature: - 40° to 254° F (± 0.9° F) Compatible Data Loggers: AEC MicroDataLogger
Architectural Energy Corp.
5-inch Temp Probe (Pete's Plug) Model: TEMP-02-T4 Measures: Temperature Description: Stainless steel liquid “Pete’s Plug” probe for use with AEC MicroDataLogger. Five inch long stainless steel probe with pipe threads and 16 foot cable attached to an MDL module. Sensor: Range (Accuracy): - Temperature: - 40° to 254° F (± 0.9° F) Compatible Data Loggers:
10/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
AEC MicroDataLogger
Architectural Energy Corp.
Air Temperature Module Model: TEMP-02-1-T01 Measures: temperature Description: Air temperature sensor directly mounted on a pre-wired module with no cable. For use with the AEC MicroDataLogger. Sensor: Range (Accuracy): - Temperature: - 40° to 254° F (± 0.9° F) Compatible Data Loggers: AEC MicroDataLogger
Architectural Energy Corp.
MicroDataLogger 202 Model: MDL-202 Measures: Pulses, AC Millivolts, DC Milliamps, DC Voltage Signal, Temperature, Relative Humidity, Occupancy, Light, Status Description: Data logger with 4 universal input/output channels and rechargeable battery. Can be used with a variety of inputs including proprietary sensors for temperature, relative humidity, occupancy and light level and general process signals with MDL signal conditioning modules. Meter has an LCD display for realtime readings. Logger uses a PC serial interface for data transfer. Logger dimension: 5.8 in x 4.4 in x 1.6 in. Sensor: Range (Accuracy): - DC Voltage: 0 to 5 VDC or 0 to 10 VDC - AC Millivolt: 0 to 333 mV RMS (± 0.1% of full-scale) - DC Milliamp: 0 to 20 mA DC Resolution: 12 bit Memory/Records: 64,000 records Related Application Note(s): AEC MicroDataloggers
Architectural Energy Corp.
Relative Humidity On Module Model: RH25-1-HUM50 Measures: Relative Humidity Description: Relative Humidity sensor mounted on pre-wired module with no extended length cable for use with the MicroDatalogger. Sensor: Range (Accuracy): - RH: 0% to 100% (± 3% for range of 10% to 90%) Compatible Data Loggers: AEC MicroDataLogger
11/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Ashcroft
Pressure Transducer ( 0-200 PSIG) Model: T-ASH-G2-200 Description: Intended for use with Onset H22 logger. Output 0-5VDC. Requires 9-36Vdc excitation source. Ashcroft supplies pressure transducers to Onset Computer. This transducer can be used with any logger that can take a 0-5Vdc input, including the Pace RX440, Onset H22, ACR SmartReader Plus 3 and Plus . Sensor: Range (Accuracy): 0-200psig (+/-2 psig) (+/- 1% of Full Scale)
Bacharach
Florite Air Velocity Meter Model: 800 Measures: air velocity and temperature Description: Hand-held air velocity and air stream temperature meter with digital display. 8" long thermal anemometer probe has 1/4" tip diameter. Meter calculates volumetric air flow when duct area is input into meter. Sensor: Range (Accuracy): - Air Velocity: 0 to 6000 ft/min (± 3% ± 1 digit) - Volumetric Flow: 0 to 999,999 cfm (± 3%± 1 digit) - Temperature: 32° to 176° F (± 2° F ± 1 digit)
Bacharach
Fyrite Pro Combustion Analyzer Model: 125 Measures: Oxygen, Air Temperature, Stack Temperature, CO, Draft, Differential Pressure, Combustion Air Temperature Description: Handheld residential combustion analyzer that measures combustion gases from natural gas, oil #2, propane, and kerosene appliances. Provides measurement of oxygen (O2), ambient and combustion air temperatures, stack temperature, carbon monoxide (CO), draft, and differential pressure and calculates combustion efficiency, excess air, CO2, CO (air free). Sensor: Range (Accuracy): - Ambient Air Temperature: 32 to 212º F (± 4º F) - Flue Gas Temperature: 0 to 999º F(± 4º F between 32 and 255º F, ± 6º F between 256 and 480º F, ± 8º F between 481 and 752º F) - Oxygen: 0.0 to 20.9% O2 (± 0.3%) - Carbon Monoxide: 0 to 2000 ppm CO (± 5% of reading or ± 10ppm, whichever is greater) - Draft/Differential Pressure: - 10.0 to +27.0 in. WC (±1% of reading or ±0.02 in WC, whichever is greater)
Bacharach Portable Combustion Analyzer - PCA-35 Model: PCA-35 PN 24-7192 Measures: Stack temperature, Air Temperature, NOx, Carbon Monoxide, Draft/Differental Pressure
12/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Description: Hand-held combustion efficiency analyzer designed for sampling of light industrial and residential furnaces, appliances and boilers. Calculates and displays combustion efficiency, excess air, CO2, NOx, reference O2 and CO air free. Sensor: Range (Accuracy): - Oxygen: 0.1% to 20.9% (± 0.3% on flue gas) - Air Temperature: 0° to 999° F (± 2° F between 32° to 212° F) - Stack Temperature: 0° to 2192° F (± 4° to 8° F) - Carbon Monoxide: 0 to 4000 ppm (± 5% to 10%) - Draft: - 28.0 to 28.0 in. WC (± 2% of readings, or ± 0.02 inches of water, whichever is greater) - NOX: 0 to 1000 ppm (± 5% of readings, or ± 5 ppm, whichever is greater)
Bacharach
Sling Psychrometer Measures: Dry-Bulb Temperature, Wet-Bulb Temperature Description: Compact sling psychrometer used for calculating relative humidity. Contains a slide rule calculator which correlates wet and dry bulb thermometer indications for direct reading of relative humidity. Sensor: Range (Accuracy): - Wet and Dry Bulb Temperature: 25° to 120° F - Relative Humidity: (± 5%)
Bacharach
Tru Pointe Refrigerant Leak Detector Model: 19-7112 Measures: Refrigerant Leaks Description: Portable refrigerant leak detector that detects all CFC, HFC, and HCFC refrigerant including blends. Variable intensity visual and audible alarms. Sensor: Range (Accuracy): - Alarm Sensitivity: 0.1 oz/year of R134a (hardest to detect refrigerant)
Barnant
Temperature/Air Velocity Meter Model: 637-0000 Measures: Air Velocity and Temperature Description: Hand-held meter with digital display with air velocity and temperature probe. Sensor: Range (Accuracy): - Air Velocity: 20 to 5000 fpm (± 3%) - Temperature: - 20° to 158° F (± 2.7° F) Resolution: 0.1° F
Bogen Bogen 3-Rotation tripod
13/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
(Manfotto)
Model: 3221 Description: Tripod with three-way rotation head, bubble levels and quick-release mounting plate with a friction surface.
Bogen (Manfotto)
Magic Arm Super Clamp Model: 2929 Description: Clamp-on arm with 90° pivotable and 360° rotational ends. Elbow rotates 360° and the handle fixes all three rotations. Each arm is 8" in length.
Bosch, Inc.
Laser rangefinder Model: DLR165 Measures: Distance Description: Hand-held laser distance meter for width and distance measurements as well as calculating areas and volumes in feet and meters. LCD screen for instantaneous readings. Sensor: Range (Accuracy): Measuring range 2 in ... 165 ft Distance measuring accuracy ±1/16 in
Brand Electronics
Digital Power Meter Model: 21-1850/CI Measures: Power and energy use of plug loads Description: Single-phase power meter for plug loads has an LCD readout and data logging capabilities. Logger uses a PC serial interface for data transfer and real time readings. Sensor: Range (Accuracy): - Watts: 0 to 1850 - Amps: 0 to 15 (± 3%) - Power Factor: 0 to 1.0 (± 5%) - Volts: 100 to 130 Resolution: one Watt, 0.01 Amps, .01 Power Factor, 0.1 Volt Memory/Records: 8121 records
Bushnell Sports Yardage Pro 400 Laser Rangefinder
14/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Optics
Model: Lyte Speed 400 Measures: Distance Description: Rangefinder sights and measures distance in yards or meters, and uses eye safe infrared pulses to calculate distances. Device has four targeting modes for different conditions and an LCD readout. Sensor: Range (Accuracy): - Range: 16 to 400 yards (± 1 yard)
Campbell Scientific
21X Micrologger Model: 21X Measures: Millivolt, Milliamp, Low Voltage, and Pulse Signals, Resistance Description: Data logger with 8 different analog (double ended) inputs, 6 digital inputs/outputs, 4 pulse counting channels and 4 switched excitation channels. Logger has a keypad interface and an LCD display. Logger uses a PC 9-pin serial interface for data transfer and real time readings. Resolution: 14 bit Memory/Records: 19296 records
Campbell Scientific
CR10 Measurement and Control Module Model: CR10 Measures: Millivolt, Milliamp, Low Voltage, and Pulse Signals, Resistance Description: Data logger has 6 analog (double ended) inputs, 8 digital inputs/outputs, 2 pulse counting channels and 3 switched excitation channels. Logger uses a PC 9-pin serial interface for data transfer and real time readings. Sensor: Range (Accuracy): - Millivolt Input: ± 2.5 to ± 2500 millivolt (0.1% to 0.2%) Resolution: Millivolt: 0.33 to 333 microvolt Memory/Records: 29,908 records
Campbell Scientific
Temperature & RH probe Model: 207 #7059 Measures: Temperature, Relative Humidity Description: Temperature and relative humidity sensor with radiation shield. Sensor requires 3 VAC excitation, and measures across a 150mV range to calculate the RH based on the temperature. For use with Campbell Scientific data loggers. Sensor: Range (Accuracy): - Temperature: - 40° to 140° (± 0.72° F) - Relative Humidity: 12% to 100% (± 5%) Compatible Data Loggers: Campbell CR10
15/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Celesco Transducer
Large Position Transducer Model: PTX101-0100-111-1100 Description: Cable extension transducer to measure position status. Transducer provides a voltage signal that is proportional to the linear movement of the cable. Sensor: Range (Accuracy): - Position: 2 to 100 inches (± 0.10% to 0.25% full stroke) Compatible Data Loggers: AEC MicroDataLogger
Celesco Transducer
Small Position Transducer Model: PTX101-0060-111-1100 Measures: Position Description: Cable extension transducer to measure position status. Transducer provides a voltage signal that is proportional to the linear movement of the cable. Sensor: Range (Accuracy): - Position: 2 to 60 inches (± 0.10% to 0.25% full stroke) Compatible Data Loggers: AEC MicroDataLogger
Celestaire (W. W. Boes Co.)
Astro-Compass Model: MKII Measures: Position of Sun, Position of Objects in Sky Vault Description: Solar transit used to locate the sun's position in the sky at any time of day or year. The Astro-Compass is also used to determine the shading of a site by adjacent buildings and vegetation. Related Application Note(s): Using the Astro-Compass to Study Solar Access
Measurement Computing Corp.
IQ-VmA Model: IQ-Vma Measures: Temperature, Milliamp, Millivolt and Voltage Signals Description: Voltage/milliamp input data logger with nine voltage input ranges, a current input range and an internal temperature sensor. Logger uses a PC 9 serial interface for data transfer and real time readings. Sensor: Range (Accuracy): - Temperature: - 40° to 185° F (± 0.9°F) - Inputs: - 0 to 333 mV, 0 to 1.2 V, 0 to 5 V, 0 to 10 V, 0 to 30 V, 0 to 20 mA (± 0.3%) Resolution: 12 bit Memory/Records: 21,280 records
16/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Crossbow Technology
Tilt Sensor Model: CXTA01 Measures: Tilt angle Description: Small, single axis tilt sensor that measures tilt angle. The sensor's voltage output is proportional to the sine of the tilt angle. Sensor: Range (Accuracy): - Full Range: ± 75° (± 0.5°) Resolution: 0.05°
CST/Berger
Lasermark Model: Lt-1 Laser Distance Meter Measures: Distance Description: Hand-held laser distance meter for width and distance measurements as well as calculating areas and volumes in feet and meters. LCD screen for instantaneous readings. Sensor: Range (Accuracy): - Distance: 1 ft. to 328 ft. (± 0.01 ft.)
CTRL Systems
Ultrasonic Leak Detector Model: UL101-R Measures: Vacuum, Compressed Air and Steam Leaks Description: Ultrasonic diagnostic tool that detects ultrasound in a narrow frequency band centered at 40,000 Hz. Detects and pinpoints vacuum leaks and pressure leaks in compressed air, steam and other gas systems, and electrical arcing or discharge. Sensor: Range (Accuracy): - Minimum Intensity: 10(-12) Watts/Meter2 - Minimum Ultrasonic Pressure: 2.1 X 10(-6) PA at 40 kHz
David White, LLC
Sight level Model: L6-20ANC level package Measures: Topography, Heights Description: Optical level with a 20X magnification telescope in a fixed horizontal position. Level moves in a 360° axis to measure horizontal angles. Sensor: Range (Accuracy): - Distance: Max 200 feet (± 0.02 feet at 75 feet) Related Application Note(s): Using a Surveyor's Level
Davis Energy Group
Roof Surface Albedometer Model: CM3 Pyranometer
17/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: Reflectivity in watts/m2. Description: Portable device designed for measuring the % reflectivity of low-sloped roofs using ASTM E1918 - Standard Test Method for Measuring Solar Reflectance of Horizontal and Low-Sloped Surfaces. It consists of four components: a tripod stand, a thermopile type pyranometer, a digital meter, and an angle indicator. Sensor: Range (Accuracy): - Spectral Range: 305 - 2800 nm Resolution: 1 W/m2
Daystar, Inc.
Solar Irradiation Meter Model: DS-05A Description: Daystar's DS-05A solar meter brings 'point and read' simplicity to the measurement of solar irradiance. Just turn the meter on, point the sensor at the sun and obtain a reading in Watts/m2. Sensor: Range (Accuracy): 0-1999 W/m^2 (3% from 50 - 1200 W/m^2 when pointed at the sun.) Resolution: 1 W/m^2
Dent Instruments
1000 AMP Current Transducer Model: CT-CO-N-1000-U Measures: Current Description: Clamp-on AC current probe. 0 to 1000 amps is scaled across 0 to 333 mV output. Maximum of two inch jaw opening. Sensor: Range (Accuracy): - Current: 0.1 to 1000 Amps (± 0.5% at 1000A) Compatible Data Loggers: ELITEpro K-20 Energy Survey Meter
Dent Instruments
200A hinged split core CT Model: HMC-200 Measures: Window Size 1 inches (25 mm), Current Range 1.0 - 300A AC, Output 333 mV @ 200A AC, Accuracy <1.0% at rated current, Phase Error <.5 degrees at rated current Description: wide range (1 - 300A) Compatible Data Loggers: AEC MicroDataLogger ELITEpro Related Application Note(s): ElitePro Recording Poly-Phase Power Meter
18/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Dent Instruments
20A hinged split core CT Model: HSC-020 Measures: Window Size 0.4 inches (10 mm), Current Range 0.25 - 40A AC, Output 333 mV @ 20A AC, Accuracy <0.5% at rated current, Phase Error <1.5 degrees at rated current Description: wide range 0.25 - 40A AC Compatible Data Loggers: AEC MicroDataLogger ELITEpro Related Application Note(s): ElitePro Recording Poly-Phase Power Meter
Dent Instruments
300/3000A Flexible CT Model: CTFLN3000U Measures: Current Description: Flexible current transducer with dual current range, switchable between 300A and 3000A. Flexible CT has 11" inside diameter designed for use on large buss bars and inflexible conductors. Sensor: Range (Accuracy): - Current: 10 to 3000 Amps (1% of reading) Compatible Data Loggers: ELITEpro K-20 Energy Survey Meter
Dent Instruments
3000 AMP Current Probe Model: C3000 Measures: Current Description: Large AC clamp-on current probe with jaw opening of 6 inches by 2.5 inches. 0 to 3000 amps is scaled across 0 to 333 mV output. Sensor: Range (Accuracy): - Current: 0 to 3000 Amps (± 0.5% to 1.5%)
Dent Instruments
CTlogger-USB Model: TOUCT 3G Measures: Current/Status Description: Stand-alone data logger detects current to determine the ON/OFF status of electrical equipment. Logger uses USB communication for data transfer. Logger dimension: 2.5" x 1.5" x .75". Sensor: Range (Accuracy): - Current: 0.25 amp min Resolution: 1 second Memory/Records: 8000
19/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Dent Instruments
ElitePro SP Model: ElitePro SP Measures: voltage, current, RMS power, reactive power, min/max/avg values, energy Description: Recording poly phase power meter with 4 integrated voltage references. With harmonic analysis and waveform capture. Uses 333mV CTs or RoCoil CTs. 8mB memory. Line powered. Sensor: Range (Accuracy): - Current: 0 to 6000 Amps (0.5% typical, meter only) - Volts: 0 to 600V AC or DC - Frequency: 50 or 60 Hz Memory/Records: 8mB
Dent Instruments
MAGlogger-USB 3G Model: TOUM 3G Measures: Magnetic Field Description: Stand-alone data logger detects AC-field to determine the ON/OFF status of motorized equipment. Logger uses USB communication for data transfer. Logger dimension: 2.5" x 1.5" x .75". 8,000 records Sensor: Range (Accuracy): - Magnetic Field: - Minimum 40 Milligauss Resolution: 1 second Memory/Records: 8,000 records
Dent Instruments
MAGlogger-USB 4G Model: TOUM 4G Measures: Magnetic Field Description: Stand-alone data logger detects AC-field to determine the ON/OFF status of motorized equipment. Logger uses USB communication for data transfer. Logger dimension: 2.5" x 1.5" x .75". 32,000 records Sensor: Range (Accuracy): - Magnetic Field: - Minimum 40 Milligauss Resolution: 1 second Memory/Records: 32,000 records
Dent Instruments
RoCoil Flexible CT Model: CT-R16-1310 Measures: current Description: Flexible Rogowski coil CT (5A - 5000A) Sensor: Range (Accuracy): 50A - 5000A with ELITE SP (<1% accuracy)
20/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Linearity ± 0.2% Conductor Position Sensitivity ± 2% maximum Influence of External Field ± 1.5% maximum Temperature Sensitivity 0.07% per °C Compatible Data Loggers: ELITEpro Related Application Note(s): ElitePro Recording Poly-Phase Power Meter
Dwyer Instruments
Magnehelic Differential Pressure Gage Model: 2005 Measures: Differential Pressure Description: Analog differential pressure gage that indicates negative and positive pressure. Sensor: Range (Accuracy): - Pressure: - 0.1677 to 1.034 (± 2% of full scale)
E. Vernon Hill
Borozin A.C. Gun Model: 17-023 Measures: Air Movement Description: Hand-held powder gun for studying air movement. Device is used to analyze diffusers in mechanical systems and slow-moving air currents.
Electronic Design to Market
ETEKT+ (AE1600) Model: AE1600 Measures: Thermal Resistant Coating Description: Hand-held meter detects the presence and location of a Low-E coating or any other conductive coating on or within a window assembly. Related Application Note(s): Using the ETECT+ LowE Detector
Electronic Design to Market
UV Sentry Model: UV1265 Measures: UV Transmission Description: Hand-held meter measures UV transmission percentage on a given material. Digital display for real time readings with continual updates.
21/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
watts up
Watts Up? PRO Power Logger Model: Watts Up? PRO Measures: RMS current, RMS Voltage, power and power factor Description: Data logging electricity monitor and watt meter with LCD display for real time readings. Measures maximum, minimum and average current, voltage and power and average energy usage over time. The logger uses a USB interface for data transfer to a PC. Sensor: Range (Accuracy): - Voltage: 120 VAC (+/- 1.5%, + 3 counts of the displayed value) - Current: 0 to 15 Amps (+/- 1.5%, + 3 counts of the displayed value) - Resolution: .01 watt Memory/Records: 2000
EME Systems
UTA BNC Model: UTA Description: Universal Transconductance Amplifier(UTA) for Li-Cor sensors. This device is designed specifically to amplify the microamp output of Li-Cor sensors to a voltage signal that can be received by various data loggers. It can be configured for any Li-Cor sensor. Sensor: Range (Accuracy): - Output Signal: 1, 2, 5 or 10 Volts (± 0.5%) - Input Signal: Up to 1 mA Compatible Data Loggers: ACR SmartReader 7 ACR SmartReader Plus 7 AEC MicroDataLogger Hobo 4-channel External Hobo RH/Temp/2 External Hobo RH/Temp/Light/External Hobo U-12 Temp/RH/Light/External Pace Pocket Logger Pace XR5 Logger
Energy Minneapolis Blower Door
22/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Conservatory
Model: 3 or 4 Measures: Air Flow Description: Air tightness testing system includes a variable speed fan that is sealed into an exterior doorway and is used to blow air in or out of a building for infiltration or exfiltration (air leakage) studies. Kit also includes five piece adjustable door frame, fabric door panel with viewing window and digital pressure and flow gauge. Sensor: Range (Accuracy): - Air Flow: 30 to 6,300 CFM (± 3%)
Energy Conservatory
Minneapolis Duct Blaster Model: Series B Measures: Leakage Rate (of duct systems) Description: Calibrated air flow measurement system for measuring air tightness of forced air ducts. Sensor: Range (Accuracy): -Air Flow: 20 to 1,500 CFM (± 3% )
Energy Conservatory
Pressure & Flow Gauge DG-700 Model: DG-700 Measures: Air Pressure and Flow Description: Digital differential pressure gauge with two independent pressure sensors. Operates with the Minneapolis Blower Door and Duct Blaster systems to display air flow readings. This is the successor to the DG-3. Sensor: Range (Accuracy): - Pressure: -1,250 to +1,250 Pascals or -5 to +5 in. H20 (1% of pressure reading or .15 Pa, whichever is greater) Resolution: 0.1 Pa or 0.0001 in H20
Enernet
Energy Survey Meter/Recorder Model: K20 Measures: Milliamp, Millivolt and Voltage Input Signals and Line Voltage Description: Two models of this true RMS logger have either 8 or 16 current channels, 120 to 480 VAC inputs, 8 or 16 analog inputs, 8 or 16 digital inputs, 4 or 8 digital outputs, and an eight character digital display/keypad interface. Uses a PC serial interface for data transfer and real time readings. Potential transducers are available for 120 to 480 RMS line voltage. Sensor: Range (Accuracy): - Voltage: 120 to 480 Volts - Voltage Signal: 0 to 5 Volts - Milliamp Signal: 4 to 20 mA
23/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Millivolt Signal: 0 to 333 mV RMS (1%) Resolution: 8 bit Memory/Records: 1 Megabyte
EXTECH Instruments
3-Phase True RMS Clamp-on Power Analyzer Model: 382075 Measures: Kilowatt, Power Factor, Volts, Amps Description: Hand-held true RMS clamp-on power meter measures and displays 3 phase power for balanced and unbalanced loads. Stores and recalls last 5 measurements. Sensor: Range (Accuracy): - Power: 0 to 2000 kW (± 2% or 0.5 kW) - Voltage: 0 to 600 VAC, 0 to 800 VDC (± 1.5%) - Current: 0 to 2000 Amps (± 1.5 to 2.5%)
EXTECH Instruments
EasyView Digital Light Meter Model: EA30 Measures: Illuminance/Light Levels Description: Hand-held, instantaneous illuminance meter with LCD display measures light levels in footcandles or lux. Option of four different ranges selected with range button. Meter also has data hold button to freeze displayed reading and Max/Min button for storing and recalling highest and lowest readings. Sensor: Range (Accuracy): - Illuminance: 0 to 40, 400, 4000, 40,000 footcandles (± 3% of reading ± 0.5% full scale of selected range) Related Application Note(s): A Simple Illuminance Field Study
Field Diagnostic Services
HVAC Service Assistant Model: A7075A 1000 Measures: Temperature, Pressure Description: Diagnostic tool measures temperature and pressure for packaged HVAC units and calculates superheat and subcooling. Calculates performance parameters, determines system faults and suggests corrective actions. Has palm pilot user interface for instantaneous readings. Sensor: Range (Accuracy): - Temperature: - 40 to 175° F (± 1° F from -4 to 122° F and ± 2° F from 122 to 194° F) - Suction Pressure: Vacuum to 385 psig (± 1% of reading) - Liquid Pressure: Vacuum to 700 psig (± 1% of reading)
FLEXIM AMERICAS
FLUXUS F601 2 Channel Portable Liquid Flowmeter Model: US-F601.PE
24/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Corporation
Measures: liquid velocity, total flow, BTUh Description: Dual channel portable ultrasonic liquid flow meter for non-intrusive velocity, flow and BTUh measurements. Meter has digital display and keypad for instantaneous readings and a PC serial interface for data transfer. Operates up to 14 hours on fully charged internal battery. Kit includes charger/power supply, pipe thickness gage and standard ultrasonic transducers for measuring flow for liquids with temperatures between -22 to +266 °F. Available transducers for pipe sizes between 0.4 and 48 inches on 10' cables. Includes 1 pair 100-ohm RTDs for integrated BTU/h measurements. Sensor: Range (Accuracy): installation-dependant; 1% - 2% accuracy is typical
FLIR Systems
FLIR b40 Infrared Camera Model: b40 Description: Thermal Imaging InfraRed Camera Sensor: Range (Accuracy): Temperature range -4°F to 662°F (-20°C to 350°C) Temperature accuracy ±2°C or ±2% of reading Image Storage >1000 Images (1GB micro SD memory card) Emissivity 0.1 to 1.0 (adjustable); Emissivity Table
FLIR Systems
ThermaCAM PM515 Infrared Camera Model: PM515 Measures: Infrared Radiation Emitted (from an object) Description: Portable, handheld infrared camera with built-in 24° lens and removable battery pack. Operates 1.5 hours on one battery. View high resolution real-time color image in viewfinder or output to external monitor. Creates digital BMP images that can be stored on the PC flash card. Sensor: Range (Accuracy): - Temperature: - 4 to 482ºF or -20 to 250ºC (± 0.2ºC at 30ºC, or ±0.36ºF at 86ºF) - Spectral Range: 7.5 to 13 Micrometer Resolution: Image: 8 bit
Fluke
Clamp-on AC Current Probe (Transformer) Model: y8101 Measures: AC Current Description: Current transducer to be used with the Fluke 80i digital multimeter. Jaw opening is 0.43 inch in diameter. Sensor: Range (Accuracy): - AC Current: 2 to 150 amps (± 3% + 0.15 A)
25/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Fluke
Fluke 33 True RMS Clamp Meter Model: 33 Measures: AC Current Description: Hand held true RMS clamp-on current meter with two display ranges; 0 to 40 amps and 0 to 400 amps. Accuracies are based on RMS Amps in 45 to 65 Hz range. Clamp has an opening of 1.7 inches. The meter has an LCD display for instantaneous readings. Sensor: Range (Accuracy): - 40A Scale Display Range: 0.33 to 99.99 Amps (± 2% of readings) - 400A Scale Display Range: 0.3 to 399.9 Amps (± 2% of readings) - 400A Scale Display Range: 400 to 700 Amps (± 5% of readings) Resolution: 40A scale: 0.01; 400A Scale: 0.1
Fluke
Fluke 87 True RMS Multimeter Model: Fluke 87 Measures: AC Voltage, AC Current, DC Voltage, DC Current, Resistance, Conductance, Frequency Description: Handheld true RMS multimeter that measures AC and DC voltage, current, resistance, conductance and frequency. Meter has a digital display for instantaneous readings. Sensor: Range (Accuracy): - DC Voltage: 40 mV to 1000 V (± 0.1%) - AC Voltage: 400 mV to 1000 V (± 0.7%) - DC Current: 400 milliamp to 10 amps (± 0.2%) - AC Current: 400 milliamp to 10 amps (± 1.0%) - Resistance: 400 ohms to 40 nS (± 1.0%) - Conductance: 40 nS (± 1.0%) - Frequency: 199.99 Hz to 199.9 kHz (± 1.0%) Resolution: 0.01 for all measurements
Fluke
Fluke Current/Power Probe Model: 80i-kw Measures: AC Current, DC Current, Power Description: Battery powered, clamp-on current probe for use with the Fluke 87 multimeter for current and power measurements. Device has ports for voltage input. Sensor: Range (Accuracy): - AC Current: 1 to 1000 amp (up to ± 8%) - DC Current: 1 to 1300 amp (up to ± 4%) - Power: 0.5 to 330 kW (up to ± 4% + 0.5 kW)
Fluke Fluke Temperature Probe Model: 80T-150U
26/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: Air, Surface and Liquid Temperature Description: Air, surface and non-corrosive liquid temperature sensor that is compatible with the Fluke 80i-kw multimeter. Sensor switches between °C and °F. Output is 1mV per °C or °F. Sensor: Range (Accuracy): - Temperature: - 58° to 302° F (± 1.8° F)
Garmin International
GPS Chart Plotting Receiver Model: GPSMAP 76S Measures: Position, Orientation (Direction), Distance Traveled, Barometric Pressure Description: Global Positioning System (GPS) receiver with built-in electronic compass, barometer, and odometer. Built-in cartography of a North American base map that includes Interstate and State Highways. Sensor: Range (Accuracy): - GPS: (± 49 feet or less) - DGPS (WAAS Accuracy 3 meters) - Compass: (± 5°)
GE Panametrics
Portable Transit Time Flow Meter - PT878 Model: PT878 Measures: Liquid Volumetric Flow, Totalized Flow and Flow Velocity Description: Single channel portable ultrasonic meter for non-intrusive liquid flow measurements. Meter has digital display and keypad for instantaneous readings and a PC serial interface for data transfer. Operates up to 11 hours on fully charged internal battery. Kit includes charger/power supply, pipe thickness gage and transducers for measuring flow for liquids in pipe sizes between 0.5 and 24 inches with temperatures between - 40º to 140º F. Mid-range and small transducers for temperatures up to 300º F also available. Sensor: Range (Accuracy): - Velocity: -40 to 40 ft/s (± 1% to 2% for pipes with inside diameter greater than 6 inches and ± 2% to 5% for pipes with inside diameter less than 6 inches) Memory/Records: 100,000 Records
GE Panametrics
RTD Model: CR-1-24-0-0 Measures: Temperature Description: 100 ohm resistance type temperature sensors. Sensor: Range (Accuracy): - Temperature: (± 0.27° F for the wetted RTDs)
27/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
GE Panametrics
Small Pipe Transducers - #24 Model: CF-LP-2EM40NM-1 Measures: Liquid Flow Description: Small pipe transducers and clamping fixture for the Panametrics flow meters for pipe sizes ranging from 0.5" to 2.0" OD. For measuring flow for liquids with temperatures ranging from -40 to 248°F. Sensor: Range (Accuracy): - Flow: (± 0.5 nanosecond)
Harbortronics
DigiSnap 2000 Model: 2000 Description: Electronic shutter release compatible with Nikon Coolpix cameras. Can be configured to take a single picture or for time-lapse photography.
Hart Scientific
Dry-well Temperature Calibrator Model: 9105 Low-temp dry-well Measures: Temperature Sensor Accuracy Description: Low-temperature dry well bath for calibrating temperature sensors. Insertion well dimensions are 1/4", 1/4", 3/16" and 1/8". The calibrator has memory for 100 temp set-points. Sensor: Range (Accuracy): - Temperature (maintained for calibration): - 13° to 284° F (± 0.18° F ) Resolution: 0.018° F
Hart Scientific
Handheld Thermometer model 1522 Model: 1522 Measures: Ambient Temperature, Surface Temperature Description: Digital handheld temperature meter with surface temperature probe. Meter has a data logging capability and is battery or AC powered. Meter has an LCD display for instantaneous readings and uses a PC serial interface for data transfer and real time display. Sensor: Range (Accuracy): - Temperature: 4 ranges from - 328° to 1764° F (± 0.045° to 0.27° F depending on range) - Surface Temperature: 32° to 167° F (± 0.36° F) Resolution: 0.0018° F Memory/Records: 10,000
Hart Scientific Precision Industrial PRT Model: 5627
28/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: Temperature Description: 6" Stainless steel Pt-100 Ohm, 4-wire temperature probe for use with Hart digital handheld thermometer, model# 1522. 4" minimum immersion depth necessary for accurate temperature measurement. Sensor: Range (Accuracy): - Temperature: - 328° to 572° F (± 0.099° F)
Hart Scientific
Thermistor Probe Model: 5610 Measures: Temperature Description: 6" stainless steel, high accuracy, 10k-ohm thermistor, immersion temperature probes for use with the Hart handheld digital thermometer, model# 1522. 2" minimum immersion depth. Sensor: Range (Accuracy): - Temperature: 32° to 212° F (± 0.027° F)
Keyspan
USB Serial Adapter - USA 19HS Model: 19HQ Description: High Speed USB to serial adaptor for use with RS-232 serial devices. Windows, Mac, Linux and Pocket PC compatible. Includes CD. Compatible Data Loggers: ELITEpro Hobo 4-channel External Hobo RH/Temp/2 External Hobo RH/Temp/Light/External
Konica Minolta
Chroma Meter CL-200 Model: CL-200 Measures: Correlated Color Temperature, Illuminance Description: Hand-held cosine and color-corrected meter with LCD display and detachable sensor for measuring correlated color temperature, illuminance, tristimulus values, chromaticity and color difference. Meter self-calibrates before use, and the hold button can be used to freeze the displayed illuminance value. Sensor: Range (Accuracy): - Illuminance: 0.001 to 29,990 footcandles (± 2% + 1 digit of displayed value) - Wavelength: 400 nm to 760 nm Related Application Note(s): A Simple Illuminance Field Study Using a Minolta Illuminance Meter
29/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Konica Minolta
Illuminance meter - T-1H Model: T-1H Measures: Illuminace Description: Hand-held illuminance meter with LCD display and detachable sensor with output in lux or footcandles. Sensor is cosine-corrected. Meter self-calibrates before use, and the hold button can be used to freeze the displayed illuminance value. Sensor: Range (Accuracy): - Illuminance: 0.001 to 9,990 footcandles (± 2% + 1 digit of displayed value) - Spectral response: 400 to 760 nm Related Application Note(s): A Simple Illuminance Field Study Using a Minolta Illuminance Meter
Konica Minolta
Luminance Meter LS-100 Model: LS-100 Measures: Surface and Light Source Luminance Description: Meter for measuring light-source luminance or surface brightness. Meter has a sighting feature and a four digit LCD display. Sensor focuses to a 1° acceptance angle with a 9° field of view. Sensor: Range (Accuracy): - Luminance: 0.001 to 299,900 candela/sq. meter (± 2% ± 2 digits) - Spectral Response: 400 to 760 nm
Konica Minolta
Luminance Meter LS-110 Model: LS-110 Measures: Light Source Luminance and Surface Reflectance Description: Portable meter for measuring luminance of light sources of reflected surfaces. Spot luminance meter with measurement acceptance angle of 1/3°. Minimum focus distance of 40 inches. Sensor: Range (Accuracy): - Luminance: 0.01 to 999,900 candela/sq. meter (± 2% ± 2 digits of displayed value) - Spectral Response: 400 to 760 nm
Konica Minolta
Minolta Illuminance Meter Extension Model: MA-1 (2m) Description: 6 foot extension cable to extend Minolta illuminance meter receptor head away from meter body for remote light readings.
Konica Minolta Minolta Illuminance Meter T-10 Model: T-10
30/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: Illuminance, light. Description: Illuminance meter; color and cosine corrected with RS-232 interface Related Application Note(s): A Simple Illuminance Field Study Using a Minolta Illuminance Meter
Konica Minolta
Spectrophotometer Model: CM-2600d Measures: Spectral Reflectance and Color Description: Portable integrating sphere type spectrophotometer measures surface reflectance and color properties of materials. Sensor: Range (Accuracy): - Wavelength: 360 nm to 740 nm - Reflectance: 0 to 175% Resolution: Reflectance: 0.01%
KVH Industries
Datascope Measures: True Direction, Magnetic Direction and Distance Description: Digital 5x30 monocular compass/rangefinder. References magnetic north and determines distances to objects of known height. Chronometer enables time-stamped readings. Sensor: Range (Accuracy): - Direction: 0 to 360º (± 0.5º of readings) Resolution: 0.1º
Lascar Electronics
Carbon Monoxide Data Logger (USB) Model: EL-USB-CO Measures: carbon monoxide Description: measures and stores up to 32,510 Carbon Monoxide (CO) readings over a 0 to 1000 ppm measurement range. A bright red LED will flash and a buzzer can sound when a preset warning level has been exceeded. Sensor: Range (Accuracy): 0 to 1000 ppm Resolution: 6% of reading Memory/Records: 32,510 Measurements
LI-COR LI-1400 DataLogger Model: LI-1400 Measures: Light levels and solar radiation with Li-Cor sensors Description: Datalogger with three BNC connectors for use with Li-Cor photometric and pyrometric
31/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
sensors. 16 character LCD screen for instantaneous readings and uses a PC serial interface for data transfer. Sensor: Range (Accuracy): - Voltage Input: ± 76 to ± 152 microvolts (± 0.15%) - Current Input: ± 7.6 to ± 30.4 picoamps (± 0.3% to ± 0.5%) Resolution: 16 bit Memory/Records: 96K records
LI-COR
Li-Cor Light Meter - LI-250 Model: LI-250 Measures: Illuminance and Radiation (with external sensors) Description: Instantaneous light meter with digtial display compatible with LI-COR pyranometer and photometric sensors. Sensor: Range (Accuracy): - Radiometric: 0 to 1999 watts/square meter (± 5%) - Photometric: 0 to 19,999 footcandles (± 5%) - Quantum: 0 to 19,999 µmol/second/square meter (± 5%) Resolution: Radiometric: 0.001 to 0.1 W/m2; Photometric: 0.01 to 1 fc; Quantum: 0.01 to 1 µmol/s/m2
LI-COR
LI-COR Photometric Sensor - LI-210SA Model: li-210sa Measures: Illuminance Description: Photometric sensor to measure light levels with a spectral response curve that matches that of the human eye. Sensor is fully cosine-corrected to an 80° angel of incidence. Sensor has a 10 foot long cable. Sensor: Range (Accuracy): - Illuminance: 0 to 19,999 footcandles (± 5%) - Spectral Response: 400 nm to 760 nm Compatible Data Loggers: AEC MicroDataLogger Campbell 21X Campbell CR10 LI-1400 Datalogger Pace Pocket Logger Pace XR5 Logger
LI-COR LI-COR Pyranometer Sensor - LI-200SA Model: li-200sa Measures: Solar Radiation
32/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Description: Sensor for measuring global solar radiation. Sensor is fully cosine-corrected to an 80° angle of incidence and comes with 10 feet of cable. Sensor: Range (Accuracy): - Solar Radiation: 0 to 1999 Watts/square meter (± 5%) - Spectral Response: 400 nm to 1100 nm Compatible Data Loggers: AEC MicroDataLogger Campbell 21X Campbell CR10 LI-1400 Datalogger Pace Pocket Logger Pace XR5 Logger
LI-COR
LI-COR sensor leveler Model: 2003s Description: Mounting base for LI-COR sensors. Base has level bubble, leveling screws, pilot holes for mounting and a setscrew for fixing the sensor in place.
Magnelab
Split Core Current Transducer Model: SCT-0750 or SCT-1250 Measures: AC Current Description: AC split core current transformers with a 0.75 or 1.25 in. opening. Snap closing/opening feature with 8' twisted pair leads. Available ranges of 5, 15, 20, 50, 100, 150, 200, 250 and 300 amps are scaled across 0 to 333 millivolts. Sensor: Range (Accuracy): - AC Current: 10 to 130% of rated CT amps (± 1%) Compatible Data Loggers: AEC MicroDataLogger ELITEpro K-20 Energy Survey Meter
Miller & Weber -30 to 124° F Thermometer Model: T3426 Measures: Temperature (surface) Description: Surface temperature thermometer. Sensor: Range (Accuracy):
33/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Temperature: - 30° to 124° F
Minox Processing Labs
Windwatch Pro Model: 63001 Measures: Wind Speed, Temperature, Air Pressure and Altitude Description: Hand-held meter with digital display measures wind speed, ambient temperature, air pressure, and elevation. Sensor: Range (Accuracy): - Wind Speed: 1 to 40 m/s (± 4%) - Temperature: - 4° to 131° F (± 4%)
Miscellaneous
Split Extension Cord Description: Standard extension cord split to 3 wire for monitoring current.
Modus Instruments
Pressure Transducer (0-0.3") Model: T30-003 Measures: Differential Pressure Description: Measures differential, gage pressure or vacuum, suitable for air or inert gases with a range of 0-0.3 inH2O. DC voltage in, and 4-20mA out. Supply voltage: 11-32 Vdc. Protected against reversal of polarity. Sensor: Range (Accuracy): - Pressure: 0.0 to .3 inch H2O
Modus Instruments
Pressure Transducer (0-2") Model: T30-020-15-017 Measures: Differential Pressure Description: Measures differential, gage pressure or vacuum, suitable for air or inert gases with a range of 0-2.0 inH2O. DC voltage in, and 4-20mA out. Supply voltage: 11-32 Vdc. Protected against reversal of polarity. Sensor: Range (Accuracy): - Pressure: 0.0 to 2.0 inch H2O
34/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Monarch Instrument
NovaStrobe Stroboscope Model: DB Plus 115/230 Measures: Rotational Rate Description: Hand-held tachometer uses strobe light to measure rotational speed. An adjustment allows the user to match the Stroboscope flash rate with the rotation. Meter includes analog output and tripod mount and battery charger. Sensor: Range (Accuracy): - Rotational Rate: 30 to 14,000 FPM / RPM ( ± 0.01%) Resolution: 0.1 fpm Related Application Note(s): Novastrobe - Stroboscope
Nielsen-Kellerman
Kestrel 2000 Model: K2000 Measures: Wind Speed, Temperature Description: Hand-held thermometer and wind meter with digital display and data hold button measures average and current wind speed, and temperature. Sensor: Range (Accuracy): - Wind Speed: 0.3 to 40 m/s (± 3% or ± 0.1 m/s) - Temperature: - 20° to 158° F (± 2° F)
Nikon
Coolpix 4500 Digital Camera Model: 4500 Description: 4.0 Megapixel digital camera with 4X zoom lens and LCD monitor. Used with a digital fisheye converter or a wide angle converter as a site analysis tool. Related Application Note(s): Taking a Fisheye Photograph Using the Sunpath Software
Nikon
Fisheye Converter Model: FC-E8 Description: Digital fisheye converter for Nikon Coolpix digital cameras. Converter provides a 183° image that is used to photograph the sky dome over a site for shading analysis. Related Application Note(s): Taking a Fisheye Photograph Using the Sunpath Software
Nikon Wide Angle Converter Model: WC-E63 Description: Wide angel converter for Nikon Coolpix digital cameras. Approximate viewing angle with converter is 84º.
35/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
NovaLynx
Current Loop Wind Station Model: 200-WS-22 Measures: Wind Speed, Wind Direction Description: Wind speed and direction sensor with a 3-cup anemometer and a wind vane rotating assembly. The encoder electronics package is housed within a sealed, NEMA enclosure. The circuitry contains two independent 4-20 mA data output channels. Sensor: Range (Accuracy): - Wind Speed: 0 to 100 mph (± 1 mph or 3%) - Wind Direction: 0 to 360° (± 3°) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger
Ohio Semitronics
kW/kWh Plug-load box Model: W-117cx5 Measures: Wattage, Watt/Hours Description: Plug load box contains a watt/watt-hour transducer for 120V, single phase loads. Meter provides a pulse output equal to 1 watt-hour per pulse and a 0-5 VDC output proportional to wattage. Sensor: Range (Accuracy): - Current: 0 - 20 amps (± 0.5%) - Voltage: 0 to 150 volts (± 0.5%) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger
Omega Engineering
4-in-1 Meter - HHF81 Model: HHF81 Measures: Air Velocity, Temperature, Relative Humidity and Illuminance Description: Instantaneous meter with digital display. Sensor: Range (Accuracy): - Air Velocity: 80 to 5910 ft/min, 0.4 to 30.0 m/s, 0.9 ti 67.0 mph, 1.4 to 108.0 km/hr (<= 20 m/s ± 3% FS, >20 m/s ± 4% FS) Temperature: 32º to 122º F (± 2.5ºF)
36/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Related Application Note(s): A Simple Illuminance Field Study
Omega Engineering
Type K Thermocouple Probe Model: TJ240-CASS-ISU-8 Measures: Temperature Description: Wide-range Type K Thermocouple with 12 ft. lead with transition joint and 8" stainless steel probe. Sensor: Range (Accuracy): - Temperature: - 454° to 1600° F (± 1.98° F or ± 4.4% whichever is greater) Compatible Data Loggers: ACR SmartReader Plus 6
Omega Engineering
Type K Thermocouple Probe 6" - 1/8 dia Model: KTSS-HH Description: Type K Thermocouple probe suitable for selected Hobo loggers and meters such as Omega 4-1 multimeter
Omega Engineering
Type T Thermocouple Wire Model: TT-T-20 Measures: Temperature Description: Type T Thermocouple wire uses two metals, copper and constantan, to produce a current proportional to temperature. This non-linear signal needs a reference meter to provide an accurate reading. Sensor: Range (Accuracy): - Temperature: - 450 to 500º F Compatible Data Loggers: ACR SmartReader Plus 6 Campbell 21X Campbell CR10 Hobo Type T Thermocouple
Onicon
Dual turbine flow sensor Model: F-1200 Measures: Flow Description: Insertion sensor for measuring flow of water-based liquid. Fits schedule 40, 4 inch pipe size. Liquid temperature range up to 180° F continuous and 200° F at peak. Sensor has a 400 psi maximum operating pressure and 18 pulses per gallon. Sensor output is 15 VDC signal. Sensor: Range (Accuracy):
37/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Flow: 2.5 to 60,900 GPM, depending on pipe size (± 2% or better, depending on range) Compatible Data Loggers: AEC MicroDataLogger
Onset Computer Corp.
Ext Temp/RH Logger (UX100) Model: UX100-023 Measures: temp/RH Description: Stand-alone data logger with external sensor for temperature and relative humidity. RH accuracy to 2.5%. Logger uses USB communication for data transfer. Sensor: Range (Accuracy): ±0.38°F from 32° to 122°F RH: ±2.5% from 10% to 90% typical Memory/Records: 128kb Related Application Note(s): Onset HOBOware Software
Onset Computer Corp.
High Temperature Stainless Steel Probe-Type K Model: TCP6-K12 Measures: Temperature Description: 12" stainless-steel probe; 3/16” diameter with isolated Type K thermocouple with 1" handle with spring-type strain relief and subminiature connector for use with the Hobo thermocouple data logger. 6 foot cable length and 3/16 inch diameter probe. Sensor: Range (Accuracy): - Temperature: 32°F to 559°F (±4°F) and 559°F to 1650°F (± 0.75%) Compatible Data Loggers: Hobo U12 Type J,K,S,T Thermocouple Logger
Onset Computer Corp.
HOBO FlexSmart/Energy Pro Logger H22-001 Model: H22-001 Measures: Pulse signal with adapter, AC Millivolt, DC Milliamp and DC Voltage Signals, Temperature, Relative Humidity Description: Data logger with 12 channels; 6 channles for proprietary Smart Sensors for measuring temperature and relative humidity and 6 channels for 2 channel TRMS modules or 2 channel Analog modules. TRMS modules are used for AC current and voltage measurements. Analog modules are used for common 4-20mA and 0-20VDC sensor inputs. Logger is powered either by AA alkaline batteries or with an external AC power supply and can provide 12 VDC excitation to sensors. Uses Hoboware software and a PC serial interface. The logger is compatable with a USB to serial converter. Logger dimension: 6.06 in x 3.69 in x 2.00 in (with modules). Sensor: Range (Accuracy): - DC Voltage: 0 to 2.5V or 0 to 5 VDC or 0 to 10 VDC or 0 to 20VDC (± 0.25% full scale range from 50 mV to
38/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
full scale range) - AC Millivolt: 0 to 333 mV RMS (± 0.3% of reading of reading ± 0.5% of full scale range) - DC Milliamp: 0 to 20 mA DC (± 0.25% full scale range from 50 mV to full scale range) Resolution: 12 bit Memory/Records: 512 K
Onset Computer Corp.
HOBO Motor ON/OFF AC Field Sensor Model: H06-004-02 Measures: Motor Run-Time Description: Stand-alone data logger detects AC-field to determine the ON or OFF status of motorized equipment. Logger records time, date and state (on/off) information for each change in state. Blinking LED confirms operation. Programmable launch time. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 2.4 in x 1.9 in x 0.8 in. Sensor: Range (Accuracy): - Electromagnetic Field: Greater than 2 Gauss at 60Hz Resolution: 0.5 seconds Memory/Records: 2000 records Related Application Note(s): Using the HOBO Motor On/Off Logger Onset Boxcar Software - The Multiple Launch Feature
Onset Computer Corp.
HOBO Pro RH/TEMP Model: H08-032-08 Measures: Relative Humidity, Temperature Description: This high accuracy, two channel weatherproof data logger can be installed in outdoor environments. Logger uses a PC serial interface for data transfer and real time readings. Sensor: Range (Accuracy): - Temperature: - 22° to 122° F (± 0.33° F at 70° F) - Relative Humidity: 0 to 100% (± 3%, ± 4% in condensing environments) Resolution: 8 bit or 12 bit (2 modes) Memory/Records: 64k records Related Application Note(s): Boxcar Software for the HOBO Data Logger Onset Boxcar Software - The Multiple Launch Feature
Onset Computer Corp.
HOBO Pro Temp/Ext. Temp Model: H08-031-08 Measures: Temperature Description: High accuracy, two channel, weather-proof, temperature data logger. The exterior temperature sensor has a 6' lead. Logger uses a PC serial interface for data transfer and real time readings. Sensor: Range (Accuracy):
39/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Internal Temperature: - 22° to 122° F (± 0.33° F at 70 °F) • External Temperature: - 40° to 212° F (± 0.33° F at 70° F) Resolution: 8 or 12 bit (2 modes) Memory/Records: 64k records Related Application Note(s): Boxcar Software for the HOBO Data Logger Onset Boxcar Software - The Multiple Launch Feature
Onset Computer Corp.
HOBO Pro v2 Temp/RH U23-001 Model: U23-001 Measures: Temperature, RH Description: High accuracy, two channel, weather-proof, temperature and relative humidity data logger. Uses a USB interface for data transfer and real time readings. Requires USB optically coupled Base station BASE-U-4 which serves as the communication cable. Sensor: Range (Accuracy): - Internal Temperature: -40° to 158°F; RH ±2.5% from 10% to 90% (typical), to a maximum of ±3.5% including hysteresis Resolution: 12 bit
Onset Computer Corp.
HOBO Pro v2 Water Temp Model: U22-001 Measures: water temperature Description: submersible water temperature logger, -40 to +158 degrees F in air, 122 degrees F maximum sustained water temperature maximum depth 400 ft Sensor: Range (Accuracy): accuracy .36F from 32 - 122 degrees F Resolution: .04 degrees F at 77 degrees F Memory/Records: approx 42,000 measurements
Onset Computer Corp.
HOBO RH/Temp/Light/Ext Model: H08-004-02 Measures: Temperature, Relative Humidity, Light Intensity, AC Current and External Temperature with proprietary sensors, Low DC Voltage Signals Description: Stand-alone four channel data logger with internal sensors for monitoring relative light levels, temperature, relative humidity, and one external channel for proprietary temperature thermistors and current transducers and non-proprietary DC voltage signals. The logger uses an RS232 interface for data transfer and real time readings.in. Sensor: Range (Accuracy): - Temperature: - 4° to 158° F (± 1.27° F at 70° F) - Relative Humidity: 25 to 95% (± 5%)
40/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Light Intensity: 2 to 600 footcandles typical, maximum varies from 300 to 900 footcandles - Voltage Signal: 0 to 2.5 DC volts (±10 mV ±3% of reading) Resolution: 8 bit Memory/Records: 7943 records Related Application Note(s): Boxcar Software for the HOBO Data Logger Onset Boxcar Software - The Multiple Launch Feature
Onset Computer Corp.
HOBO Shuttle Model: H09-002-08 Description: Pocket-sized shuttle used to readout and relaunch HOBO data loggers and download to a PC. Synchronizes HOBO clocks with the PC's clock. Stores data from up to fifty-one 8K loggers. Memory/Records: 468K Related Application Note(s): Boxcar Software for the HOBO Data Logger
Onset Computer Corp.
HOBO STATE Model: HO6-001-02 Measures: State Open/Close Description: Two-channel data logger monitors changes in state using either an internal magnetic reed switch and an external magnet mounted on doors, windows or blinds to monitor open/closed status or using an external input cable to monitor contact closures or passive relay switches. Logger uses a PC serial interface for data transfer and real time readings. Blinking LED confirms operation. Logger dimension: 2.4 in x 1.9 in x 0.8 in. Sensor: Range (Accuracy): - Spacing: Closed state less than and equal to 1/4 inch, open state greater than and equal to 3/4 inch. Resolution: 0.5 seconds Memory/Records: 2000 records Related Application Note(s): Boxcar Software for the HOBO Data Logger Onset Boxcar Software - The Multiple Launch Feature
Onset Computer Corp.
HOBO U12 J,K,S,T Thermocouple Logger Model: U12-014 Measures: Temperature Description: Thermocouple logger with two temperature channels. Channel 1 is for external Type J, K, S or T thermocouples. Channel two is the logger's internal temperature sensor for cold-junction compensation of the thermocouple output. Compatible with standard thermocouples with standard subminiature connectors. Logger uses a direct USB connection. Logger dimension: 2.3 in x 2.9 in x 0.85 in. Sensor: Range (Accuracy): - Internal Temperature: 32º to 122º F (± 0.63º F)
41/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Resolution: 12-bit Memory/Records: 43,000 measurements Related Application Note(s): Onset HOBOware Software
Onset Computer Corp.
HOBO U12-006 4 Channel Indoor External Model: U12-006 Measures: Temperature and Current with proprietary sensors and Low DC Voltage and current loop Signals for various external sensors Description: Stand-alone data logger with four input channels for proprietary sensors for temperature, AC current or non-proprietary low DC voltage signals. Logger uses a USB interface for data transfer and real time readings. Logger dimension: 2.3 x 2.9 x 0.9 inches Resolution: 12 bit Memory/Records: 43,000 measurements
Onset Computer Corp.
HOBO U12-012 RH/Temp/Light/Ext Datalogger Model: U12-012 Measures: Temperature, Relative Humidity, Light; 0 to 2.5 VDC input for external sensors: Temperature, Current, Voltage Description: Stand-alone four channel data logger with internal sensors for monitoring relative light levels, temperature, relative humidity, and one external channel for proprietary temperature thermistors and current transducers and non-proprietary DC voltage signals. The logger uses a USB interface for data transfer and real time readings. Logger dimension: 2.3 in x 2.9 in x 0.85 in. Sensor: Range (Accuracy): - Temperature: - 4° to 158° F (± 0.63° F) - Relative Humidity: 5 to 95% (± 2.5%) - Light Intensity: 1 to 3000 footcandles typical - Voltage Signal: 0 to 2.5 DC volts (±10 mV ±3% of reading) Resolution: 12 bit Memory/Records: 43,000 records Related Application Note(s): Onset HOBOware Software
Onset Computer Corp.
Hobo U9 Motor On/Off Data Logger Model: U9-004 Measures: Magnetic Field of AC Motor Description: Stand-alone data logger detects AC-field to determine the ON or OFF status of motorized equipment. Logger records time, date and state (on/off) information for each change in state. Blinking LED confirms operation. Programmable launch time. Logger uses a USB interface for data transfer and real time readings. Logger dimension: 1.8 in x 2.38 in x .77 in. Sensor: Range (Accuracy):
42/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- AC Field: Sensitivity Threshold 750 mGauss@60 Hz Memory/Records: Up to 43,000 State Changes Related Application Note(s): Using the HOBO Motor On/Off Logger
Onset Computer Corp.
HOBO Weather Station Measures: Temperature, Relative Humidity, Wind Speed, Wind Direction, Radiation Description: Weatherproof datalogger with up to 15 input channels mounted on 3-meter tripod. Weather station includes the following Hobo Smart Sensors: wind speed and direction sensor, temperature and relative humidity sensor enclosed in a radiation shield and silicon pyranometer with level for radiation measurements. Not made to withstand wind gusts over 120 mph. Sensor: Range (Accuracy): - Wind Speed: 0 to 99 mph (up to ± 4%) - Wind Direction: 0 to 358°, 2° dead band (± 5°) - Temperature: - 41° to 167° F (± 1.3° F at 77° F) - Relative Humidity: 0 to 100% up to ± 4% in condensing environments) - Radiation: 0 to 1280 W/m2, within spectral range of 300 to 1100 nm (± 10 W/m2 or ± 5% typical) Resolution: 8 bit Memory/Records: 500,000 records Related Application Note(s): Onset HOBOware Software
Onset Computer Corp.
Motor Logger (UX90 512kB) Model: UX90-004M Measures: Motor on/off status Description: Stand-alone data logger detects AC-field to determine the ON/OFF status of motorized equipment. Logger uses USB communication for data transfer. Memory/Records: 512kB Related Application Note(s): Onset HOBOware Software
Onset Computer Corp.
Narrow Range Temperature Sensor TMC6-HB Model: TMC6-HB Measures: Temperature Description: Narrow range external temperature sensor for Hobo data loggers. 6 foot cable and 0.3 inch diameter sensor; fits in 3/16 inch holes. Sensor: Range (Accuracy): - Temperature: 32° to 110° F (± 0.7° F with H8, ± 0.45° F with U12 at 68° F) Compatible Data Loggers: Hobo 4-channel External Hobo RH/Temp/2 External Hobo RH/Temp/Light/External
43/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Hobo U-12 Temp/RH/Light/External Resolution: 0.3° F at 68° F with H8, 0.025° F at 68° with U12
Onset Computer Corp.
Occupancy / light logger (12 meters) Model: UX90-006 Measures: light on/off status, occ/unocc status, 84,650 measurements Description: simultaneously logs light and occupancy. 12 meter diameter sensitivity Memory/Records: 128kb (84,650 measurements) Related Application Note(s): Onset HOBOware Software Recording Light Fixture Operation Schedules
Onset Computer Corp.
Onset 100A CT - AC Model: CTV-C Measures: AC current Description: 100A CT for use with Hobo loggers (2.5v). Window size 1.1 x 0.8 in.
Onset Computer Corp.
Onset 200A CT – AC Model: CTV-D Measures: AC current Description: 200A CT for use with Hobo loggers (2.5v). Window size 1.54 x 1.26 in.
Onset Computer Corp.
Onset 20A CT - AC Model: CTV-A Measures: AC current Description: 20A CT for use with Hobo loggers (2.5v). Window size 1.1 x 0.8 in.
Onset Computer Corp.
Onset 50A CT - AC Model: CTV-B Measures: AC current Description: 50A CT for use with Hobo loggers (2.5v). Window size 1.1 x 0.8 in.
Onset Computer Corp.
Onset 600A CT – AC Model: CTV-E Measures: AC current Description: 600A CT for use with Hobo loggers (2.5v). Window size 2.92 x 2.46 in.). Compatible Data Loggers: AEC MicroDataLogger ELITEpro
44/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Related Application Note(s): ElitePro Recording Poly-Phase Power Meter
Onset Computer Corp.
Optic USB base station Model: BASE-U-4 Description: includes 5 plastic couplers for use with a variety of loggers: UA Pendant, U20 Water level, U22 Water temp, UTBI TidbiT v2, and U23 HOBO Pro v2.
Onset Computer Corp.
RH, Temp, 2 External Channel HOBO Model: H08-007-02 Measures: Relative Humidity, Temperature, 0 to 2.5 VDC with External sensors: Temperature, Current, Voltage Description: Stand-alone four channel data logger with one internal relative humidity sensor, one internal temperature sensor, and two external channels for proprietary sensors for temperature, AC current and non-proprietary low voltage signal input. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 2.4 in x 1.9 in x 0.8 in. Sensor: Range (Accuracy): - Temperature: - 4° to 158° F (± 1.27° F at 70° F) - Relative Humidity: 25% to 95% (± 5%) - Voltage Signal: 0 to 2.5 DC volts (±10 mV ±3% of reading) - Milliamp Signal: 4 to 20 mA (±10 mV ±3% of reading) Resolution: 8 bit Memory/Records: 7943 records Related Application Note(s): Boxcar Software for the HOBO Data Logger Onset Boxcar Software - The Multiple Launch Feature
Onset Computer Corp.
Temperature Sensor TMC6-HA Model: TMC6-HA Measures: Temperature Description: Wide range external temperature sensor for Hobo data loggers. 6 foot cable and a sensor diameter of 0.2 inch. Sensor: Range (Accuracy): - Temperature: - 40° to +212° F (± 0.9° F with H8, ± 0.45° with U12 at 68° F) Compatible Data Loggers: Hobo 4-channel External Hobo RH/Temp/2 External Hobo RH/Temp/Light/External Hobo U-12 Temp/RH/Light/External Resolution: ± 0.7°F at 68°F with H8, ± 0.05° F at 68° F with U12
45/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Opti-Logic
Laser Hypsometer/Rangefinder Model: 400LH Measures: Distance, Vertical Angle, Height Description: Laser distance and vertical angle sensor. Calculates height of objects. Sensor: Range (Accuracy): - Distance: 4 to 400 yards, or 0 to 999 yards in reflective mode (± 1 yard, or ± 2 yards for very dark or very bright targets) - Height: Range depends on distance from object (± 18 inches, or ± 1 yard for very dark or very bright targets) - Vertical Angle: - 60° to 70° (± 1°) Resolution: 1 foot, 0.5 yards, 0.1 meter, or 0.1 degree
P3 International
Kill A Watt EZ Model: P4460 Measures: See Sensor: Range window to the right. Description: Unit retains data after unplugged, until reset. Sensor: Range (Accuracy): Function Range Accuracy (Typ.,Max.) RMS Voltage 85-125 Vrms (0.2%, 1%) RMS Current 0.00~15.00 Arms (0.3%, 1%) Active Power 0~1875 Watt (0.5%, 2%) Apparent Power 0~1875 VA 0. (5%, 2%) Line Frequency 47.0~63 Hz (0.1 Hz, 2%) Power Factor 0.00~1.00 (0.01, 0.03) Power Quantity 0.00~9999 KWH (0.5%, 2%) Time Quantity 00:00~9999 30ppm Display Update 1 Sec Power Consumption 10 Wmax Typical: V=90V~125V, A=0.2A~15A
P3 International
Kill A Watt Meter Model: P4400 Measures: Voltage, AC Current, Power, Frequency, kWh Description: 110V AC plug load logger monitors electrical usage and records and stores energy consumption (kWh) in non-volatile memory. LCD display shows real time power, voltage, current, and power factor readings and accumulated kWh. Sensor: Range (Accuracy): - Voltage: 0 to 125 VAC (± 0.2%) - Current: 0 to 15 Amps (± 0.2%)
46/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Power: 0 to 1.875 kW (± 0.2%)
Pace Scientific
Pocket Logger Model: XR440 Measures: Temperature, Humidity, Pressure and AC Current with proprietary sensors, Voltage Signals and Milliamp Signals Description: Stand-alone four channel data logger that accepts a variety of input signals from proprietary sensors for temperature, pressure and AC current along with non-proprietary DC voltage and milliamp signals. Logger uses a 9-pin PC serial interface for data transfer and real time readings. Some models with extended memory are available. Logger dimension: 3.1 in x 2.1 in x 0.9 in. Sensor: Range (Accuracy): - Voltage: 0 to 5 VDC (±0.25% full scale) - Milliamp: 4 to 20 mA ( Resolution: 12 bit Memory/Records: 21,504 records Related Application Note(s): Pace Scientific Inc. Pocket Logger Software
Pace Scientific
Pressure Transducer 100 psig Model: P1500-100 Measures: Air, liquid, gas pressure Description: Pressure transducer for high and low side refrigeration and air conditioning systems, chilled water, hot water, air, gas, oil and steam pressure that will work with any data logger with a 0-5 Volt input including the Pace Scientific data loggers. No external power needed when used with the Pace data loggers, or a 2 mAmp / 5 Volt excitation is required when used with other types of loggers. Sensor has 1/4" NPT male pressure port. Sensor: Range (Accuracy): Pressure: 0 to 100 psig (±0.25% FS) Resolution: 0.03 psig
Pace Scientific
Pressure Transducer-600 psig Model: P1000-600 Measures: Gas Pressure, Liquid Pressure Description: Pressure transducer that will work with any data logger with a 0-5 Volt input including the Pace Scientific data loggers. No external power needed when used with the Pace data loggers, or a 2 mAmp / 5 Volt excitation is required when used with other types of loggers. Sensor: Range (Accuracy): - Pressure: - 15 to 600 psig (±1.5psig) (± 0.25% of Full Scale)
47/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Pace Scientific
PT907 Temperature Probe Model: PT907 Measures: Temperature Description: Proprietary Pace Scientific temperature probe with epoxy tip and 4' lead. Not for continuous immersion in water (mineral or silicon oil ok). Sensor: Range (Accuracy): - Temperature: -58 to 221°F (± 0.27° F from 32° to 104° F, better than ±0.54° F from -13° to 185° F) Compatible Data Loggers: Pace Pocket Logger Pace XR5 Logger
Pace Scientific
PT916 Temp Probe Model: PT916 Measures: Temperature Description: Pace Scientific proprietary probe has closed end stainless steel tube, suitable for liquid or gaseous immersion, refrigerant (insert into a Pete's Plug) and general temperature applications. 1/8 inch sensor diameter with 4 foot long cable. Sensor: Range (Accuracy): - Temperature: -58° to 248° F continuous duty, or intermittent max temp: 302° F (± 0.27° F from 32° to 104° F, better than ± 0.54° F from -13° to 185° F) Compatible Data Loggers: Pace Pocket Logger
Pace Scientific
PT940 Temperature Probe Model: PT940 Measures: Temperature Description: Proprietary temperature probe with closed end stainless steel tube in a moisture-proof jacket, suitable for wet environments for use with the Pace Scientific data loggers. 3/16 inch sensor diameter with 20 foot cable. Sensor: Range (Accuracy): - Temperature: - 58° to 221° F (± 0.27° F from 32° to 104° F, better than ± 0.54° F from - 13° to 185° F) Compatible Data Loggers: Pace Pocket Logger Pace XR5 Logger
Pace Scientific Temperature & RH Probe Model: TRH-100-10FT Measures: Temperature, Relative Humidity Description: Proprietary temperature & RH probe for the Pace Logger. Probe's lead length in 10 feet and
48/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
0.5 inches in sensor diameter. Sensor: Range (Accuracy): - Relative Humidity: 0 to 95% (± 2%) - Temperature: - 13° to 185° F (± 0.27° F from 32° to 104° , ± 0.55° F below 32° F and above 104° F) Compatible Data Loggers: Pace Pocket Logger Pace XR5 Logger
Pace Scientific
XR5-8X-SE DataLogger Model: XR5-8X-SE Measures: Temperature, Relative Humidity and Pressure with proprietary sensors and DC Voltage and Milliamp Signals Description: Stand-alone datalogger has eight analog and three pulse input channels. Logger uses proprietary sensors for temperature, relative humidity, pressure and non-proprietary sensors with DC voltage and milliamp output. Logger uses a PC serial interface for data transfer and real time readings. Logger dimension: 4.88 in x 2.21 in x 1.28 in. Sensor: Range (Accuracy): - Voltage: 0 to 5 volts DC (± 0.25% of full scale) - Milliamp: 4 to 20 mA Resolution: 12 bit Memory/Records: 63,642 records
Peterson Equipment
Temperature and Pressure Test Kit Model: 1500 Measures: Pressure, Temperature Description: Pressure and temperature test kit. Each kit includes one analog temperature and one analog pressure gauge for gases and liquids. Gauges have a 1/4" NPT brass housing and are compatible with neoprene and nordel valves. Sensor: Range (Accuracy): - Pressure: 0 to 100 psi (± 2% of range across middle half of scale (25 to 75 psi) and ± 3% of range outside of the middle part of the scale. ) - Temperature: 0 to 125 °F or 0 to 220° F
Pilkington Sun Angle Calculator Model: Form SA-2-82 Measures: Solar Altitude and Azimuth Angles Description: Kit with sun path diagrams for the following latitudes: 24, 28, 32, 36, 40, 44, 48, 52. Diagrams project yearly and daily position of sun into 2-D. Includes overlay for finding profile angles. Sensor: Range (Accuracy):
49/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Solar Altitude Angle: 0 to 90° from the Horizon - Solar Azimuth Angle: 0 to 120° from South
Pruftechnik AG
Vibrotip Model: VIB 8.650 Measures: Vibration Level, Bearing Condition, Cavitation, Rotation Description: Hand-held analyzer with LCD display measures bearing condition, vibration severity, surface temperature, pump cavitation and machine RPM. Displays and stores measurements for rotating equipment diagnostics. Sensor: Range (Accuracy): - Vibration Severity: 0 to 2 in/sec RMS or 50 mm/sec, 10 Hz to 1 kHz (± 5%) - Bearing Diagnosis: - 9 to 80 dB - Cavitation: -9 to 80 dB - Rotation: 60 to 30,000 rpm Resolution: 0.1 mm/s or 0.01 in./s, 1dB
R.M. Young
Wind Sentry Anemometer and Vane Model: 03001-5 Measures: Horizontal Wind Speed and Direction (Azimuth) Description: Wind anemometer with vane with DC voltage output. Sensor: Range (Accuracy): - Wind Speed: 0 to 112 mph (± 1.1 mph) - Wind Direction: 0 to 360° (± 5°) Compatible Data Loggers: Campbell 21X Campbell CR10
Raytek
MiniTemp MT4 Model: MT4 Measures: Surface Temperature Description: Non-contact infrared thermometer with laser sighting. Selectable temperature display in °C or °F. Emissivity is pre-set at .95. Distance to spot size is 8:1. Sensor: Range (Accuracy): - Temperature: 0 to 525° F (± 2%, or ± 3° F, whichever is greater)
50/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Raytek
Raytek Raynger Infrared Thermometer Model: MX4 Measures: Surface Temperature Description: Non-contact Infrared thermometer with laser sighting. Meter measures the amount of infrared energy emitted by a target object and calculates the surface temperature. Meter has digital display for instantaneous readings and emmissivity values are adjustable. Sensor: Range (Accuracy): - Temperature: - 25° to 1600° F (± 1%)
Riotronics
B424 RegistRead Model: B424 Measures: Natural Gas Usage in Cubic Feet Description: Replacement faceplate for gas meter that outputs a pulse signal that corresponds to natural gas usage. RegistRead is compatible with data loggers that accept digital, KYZ, contact closure or pulse inputs.
Rolatape
Measuring Wheel Model: 112 Measures: Distance in feet and inches Description: Measuring wheel for measuring distance on hard surface. Device has telescoping handle for portability. To obtain accurate wall to wall measuements, add the diameter of the wheel (4") to the counter reading. Sensor: Range (Accuracy): - Distance: 0 to 10, 000 feet (± 1" for every 100' measured)
SDT USA
LeakMaster Ultrasound Detector Model: 101 Measures: Compressed Air, Steam, Vacuum, Process Gas and Refrigeration Gas Leaks Description: Ultrasound detector for leaks, friction and electrical discharge.
Sensor Switch
Discriminator Model: D-1 Measures: Lighting Ballast Types Description: Handheld device that distinguishes between magnetic and electronic ballasts
Setra Systems Bidirectional Diff Pressure Txdcr +/- 2.5 inches
51/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Model: 264 Measures: Differential Air Pressure Description: Pressure transducer for measuring differential or static air pressure. Output is 0-5VDC. Sensor requires 9-30 VDC excitation. Sensor: Range (Accuracy): Pressure: - 2.5" to +2.5" WC (± 1.0% Full Scale) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger Pace XR5 Logger
Setra Systems
HVAC Pressure Transducer Model: 206/C206 Measures: Air Pressure, Gas Pressure, Liquid Pressure Description: Pressure transducer for gases or liquids. Compatible with 17-4PH stainless steel. Converts pressure to proportional 0.1 - 5.1 VDC or 4-20mA analog output. Requires 12-28 VDC excitation. Sensor: Range (Accuracy): - Pressure: 0-100 PSIG, 0-250 PSIG or 0-500 PSIG (± 0.13% FS at constant temperature) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger Pace XR5 Logger
Setra Systems
Low Differential Pressure Transducer 0-2.5" Model: 264/C264 Measures: Low Differential Air Pressure. Model 264 has 0-5vdc output. Model C264 has 4-20ma output. Description: Low differential or gage (static) pressure transducer senses differential or gage pressure and converts this pressure difference to a proportional electric output. Can be used for either air or inert gases. Sensor requires 24VDC excitation with either 0-5 V (Model 264) or 4-20 mA (model C264) output. Sensor: Range (Accuracy): - Pressure: 0 to 0.1, 0 to 0.5 or 0 to 2.5 in H2O (±1.0% Full Scale) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger
Shortridge Instruments
3-Top Air Flow Capture Hood Kit Model: 8403 Measures: Air Flow Description: Air flow capture hood kit with 2'x2', 2'x4', 1'x4' tops for use with Shortridge Airdata
52/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Multimeter. Kit includes; flow measuring base with sensing manifold. Two position flaps and control, push-button handle and carrying case.
Shortridge Instruments
Airdata Multimeter 870 Model: ADM-870 Measures: Air Velocity, Air Flow, Differential & Absolute Pressure, Temperature, Mass Flow Equivalent Description: Electronic micromanometer with digital display and keypad interface for balancing air distribution systems. Displays output in English or metric units. Sensor: Range (Accuracy): - Air Velocity: 50 to 30,000 fpm FS (± 3% of reading ± 7 fpm from 50 to 8000 fpm) - Air Flow: 25 to 2500 cfm supply, 25 to 1500 cfm exhaust (± 3% of reading ± 7 cfm from 100 to 2000 cfm) - Differential Pressure: 0.0001 to 60" WC FS (± 2% of reading ± 0.001" WC from 0.0500" to 50.00" WC) - Absolute Pressure: 14 to 40 inches Hg (± 2% of reading ± 0.1 inch Hg from 14 to 40 inch Hg) - Temperature: - 67 to 250° F (± 0.5° F from 32 to 158° F, ± 1.0° F at other temperatures) Resolution: 0.1° (Temp)
Shortridge Instruments
Datalogging Airdata Multimeter ADM-880C Model: ADM-880C Measures: Air Velocity, Air Flow, Differential & Absolute Pressure, Temperature, Mass Flow Equivalent Description: Datalogging electronic micromanometer with digital display and keypad interface for balancing air distribution systems. Displays output in English or metric units. Sensor: Range (Accuracy): - Air Velocity: 50 to 30,000 fpm FS (± 3% of reading ± 7 fpm from 50 to 8000 fpm) - Air Flow: 25 to 2500 cfm supply, 25 to 1500 cfm exhaust (± 3% of reading ± 7 cfm from 100 to 2000 cfm) - Differential Pressure: 0.0001 to 60" WC FS (± 2% of reading ± 0.001" WC from 0.0500" to 50.00" WC) - Absolute Pressure: 14 to 40 inches Hg (± 2% of reading ± 0.1 inch Hg from 14 to 40 inch Hg) - Temperature: - 67 to 250° F (± 0.5° F from 32 to 158° F, ± 1.0° F at other temperatures) Resolution: 0.1° (Temp) Memory/Records: 2000 readings
Siemens (formerly Controlotron)
Dual Channel Submersible Flow Computer 1010WDP1 Model: 1010WDP1 Measures: Liquid Flow Description: Portable ultrasonic flow meter with clamp-on transducers for non-intrusive liquid flow monitoring. Kit includes a variety of transducer sizes for use on pipe diameters ranging from 0.75 inches to 24 inches. The transducers can be used on pipe temperatures up to 250° F. Instantaneous readings are
53/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
output via graphic display screen. Logger uses a PC 9-pin serial interface for data transfer. Sensor: Range (Accuracy): - Flow: 1 to 40 ft/sec (± 0.5%) Resolution: 12 bit Memory/Records: 200 Kilobytes of Memory
Siemens (formerly Controlotron)
Ultrasonic Thickness guage Model: 7ME39510TG20 Sensor: Range (Accuracy): See manual
Simpson Electric
Sound Level Meter Model: 884-2 Measures: Sound Levels Description: Portable sound level instrument has range selector allowing the device to be set for a specific sound level. Dial readout is scaled ±10 db from the set scale. Sensor: Range (Accuracy): - Sound: 40 to 140 db
SLIK
Tripod Model: PRO 330DX Description: Lightweight titanium tripod with 3-way, quick release panhead. Weight: 3 lbs. 7 oz. Supports 6.6 lbs.
Solar Light
SnP Meter Model: Kit SL-3101 Meter PMA220 P-PMA2130 S-PMA2131 Measures: Scotopic and Photopic Illuminance Description: Hand-held digital scotopic and photopic illuminance meter that measures the spectral response following the CIE scotopic and photopic spectral luminous efficiency curves. Sensors are cosine-corrected and output is in Lux or footcandles. Meter also calculates scotopic/photopic ratio, visually effective light level and perceived brightness. Meter operates for up to 40 hours continuous use on 4 AA alkaline batteries. Sensor: Range (Accuracy): - Scotopic Illuminance: 0 to 200,000 scotopic mLux (± 5%) - Photopic Illuminance: 0 to 150,000 Lux (± 5%) Resolution: 1 mLux / 1 Lux
54/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Related Application Note(s): A Simple Illuminance Field Study
Solar Pathfinder
Solar Pathfinder Measures: Shading/Solar Access Description: The Solar Pathfinder is used for solar site analysis. Any objects that would cast shadows on a particular location are reflected in the plastic dome. The shading elements are traced onto a sunpath diagram to evaluate solar access throughout the entire year.
Solmetric
Suneye 210 with GPS Model: 210 GPS Measures: insolation Description: Suneye 210 with GPS
Sony
HI-8 Video Camera Recorder Model: CCD-TR81 Description: HI-8 handycam camcorder
Statens Institute
Sundial Measures: Time, Position of the Sun Description: This polar sundial can be adjusted for any latitude. It is ideal for evaluating the solar access of proposed structures using architectural models.
Stewart Warner
Hand Tachometer Model: 82682-G Measures: Revolutions per Minute (RPM) Description: Analog contact tachometer that reads revolutions per minute. Operates in a clockwise or counter-clockwise mode. Sensor: Range (Accuracy): - Revolutions per Minute: 0 to 4000 RPM (± 2 degrees of full scale)
Summit Technology
0.01-10 Amp Current Transducers Model: HA-10
55/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: AC Current Description: Current transducer (CT) for use with the Powersight Energy Analyzer. Sensor: Range (Accuracy): - AC Current: 0.01 to 10 Amps (± 2% of reading + 0.02 Amps RMS) Compatible Data Loggers: Powersight 250 Powersight 3000 Powersight 4000
Summit Technology
100-5000 Amps Current Transducer Model: FX5000 Measures: AC Current Description: Large, flexible current transducer (CT) for use with the Powersight Energy Analyzer. Inside diameter is 7.5". Sensor: Range (Accuracy): - AC Current: 100 to 5000 Amps (± 1%) Compatible Data Loggers: Powersight 250 Powersight 3000 Powersight 4000
Summit Technology
100A Clamp-on Probe Model: HA100 Measures: AC Current Description: Clamp-on current transducer (CT) for use with the Powersight Energy Analyzer. Inside diameter of opening is 0.5". Sensor: Range (Accuracy): - AC Current: 0.1 to 100 Amps (± 2% ± 0.2 Amps) Compatible Data Loggers: Powersight 250 Powersight 3000 Powersight 4000
Summit Technology
10-3000 Amp Current Transducer Model: FX 3000a Measures: AC Current Description: Large, flexible current transducer (CT) can fit around large, inflexible conductor. CT has 7.5" inside diameter. For use with Powersight Energy Analyzer only. Sensor: Range (Accuracy):
56/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- AC Current: 10 to 3000 Amps (± 1%) Compatible Data Loggers: Powersight 250 Powersight 3000 Powersight 4000
Summit Technology
1-1000 Amp Current Transducer Model: HA1000 Measures: AC Current Description: Current transducer for use with the Powersight Energy Analyzer. Inside diameter of 2". Sensor: Range (Accuracy): - AC Current: 1 to 1000 Amps (± 0.5% + 0.2 Amps RMS below 400 Amps, and + 2 Amps RMS above 400 Amps) Compatible Data Loggers: Powersight 250 Powersight 3000 Powersight 4000
Summit Technology
1-150 Amp Current Transducers Model: HA150 Measures: AC Current Description: Current transducer for use with the Powersight Energy Analyzer. Sensor: Range (Accuracy): - AC Current: 1 to 150 Amps (± 2% + 0.2 Amps RMS) Compatible Data Loggers: Powersight 250 Powersight 3000 Powersight 4000
Summit Technology
AC/DC Current Probes Model: DC 600 Measures: AC Current, DC Current Description: Current probe capable of measuring both AC and DC current. For use with the Powersight Energy Analyzer. Probe opening has an inside diameter of 1.18". Sensor: Range (Accuracy): - AC Current: 5 to 400 Amps rms (± 2%) - DC Current: 5 to 600 Amps DC (± 3%) Compatible Data Loggers: Powersight 250
57/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Powersight 3000 Powersight 4000
Summit Technology
Line DC Converter (LDC) Model: LDC3 Description: The LDC connects directly to line voltages via fused safety clips to provide power to the Powersight 3000 when a 120 VAC outlet is not available. Compatible Data Loggers: Powersight 3000
Summit Technology
Power Quality Analyzer PS4000 Model: PS4000 Measures: AC Voltage, Amps, AC Current, Kilowatt, Kilowatt/Hour, Power Factor, Harmonics, Transients, Swells and Sags. Description: True RMS power quality analyzer with 1000 amp current probes and voltage references for 3-phase loads. Capable of swell, sag, inrush, high-speed transient, and harmonic analysis. Meter has a LCD display for real-time readings and button interface. Stand alone logger uses a PC serial interface for data transfer. Logger dimension: 4 in x 8 in x 1.5 in. Sensor: Range (Accuracy): - AC Voltage 1 to 600 VRMS (0.1%) - AC Current: 0.01 to 5000 Amps (0.1% of readings plus accuracy of probes) - Harmonic (THD): Thru 25th or 1800 Hz (To within 1% of fundamental) Memory/Records: 4 Megabyte Related Application Note(s): Summit Technology Powersight PS-3000
Summit Technology
PS250 True RMS Energy Analyzer Model: PS 250 Measures: AC Voltage, Amps, AC Current, Kilowatt, Kilowatt/Hours, Power Factor, Harmonics Description: Stand alone true RMS, data logging, polyphase power meter can measure up to 140 measurement parameters. Four voltage clips and three proprietary 1000 Amp CT clamps are included with meter. Meter has LCD display for real-time readings and uses a PC serial interface for data transfer. Logger dimension: 4 in x 8 in x 1.5 in. Sensor: Range (Accuracy): - Voltage: 1 to 600 VRMS (± 0.5%) - AC Current: 0.01 - 5000 Amps (± 0.5% plus accuracy of current probe) - Harmonic (THD): through 50th or 3000 Hz (± 1% of fundamental) Memory/Records: Standard Mem: 1,044 Records with 53 Variables, Extended Mem: 4,540 Records with 53 Variables
58/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Related Application Note(s): Summit Technology Powersight PS-3000
Summit Technology
Single Phase Adapter Box Model: 120ADP Measures: AC Current Description: Single-phase receptacle with voltage and current leads to be used with the Powersight Energy Analyzer. Allows user to get power and waveform information on plug-loads. Sensor: Range (Accuracy): - AC Current: 0 to 15 Amps (+/-0.5%) - AC Power: 0 to 120 VAC (+/-1%) Compatible Data Loggers: Powersight 250 Powersight 3000 Powersight 4000
Summit Technology
True RMS Energy Analyzer PS-3000 Model: PS-3000 Measures: AC Voltage, AC Current, Kilowatt, Kilowatt/Hour, Power Factor, Harmonics Description: True RMS energy analyzer with 1000 amp current probes and voltage references for 3-phase loads. Meter has an LCD display for real-time readings and a keypad interface. Stand alone logger uses a PC serial interface for data transfer. Logger dimension: 4 in x 8 in x 1.5 in. Sensor: Range (Accuracy): - Voltage: 1 to 600 Volts rms (± 0.5%) - Frequency: 45 to 3000 Hz (± 0.5%) - AC Current: 0.01 to 6000 Amps (± 0.5% plus accuracy of probe) - Power: 1 Watt to 60 Megawatts (± 1% + accuracy of probe) - Power Factor: 0 to 1 (± 1% + accuracy of probe) - Energy & Cost: (± 1% + accuracy of probe) - Harmonic (THD): through 50th or 3000 Hz (± 1% of fundamental) Memory/Records: Standard Mem: 1,044 Records with 53 Variables, Extended Mem: 4,540 Records with 53 Variables Related Application Note(s): Summit Technology Powersight PS-3000
Summit Technology
True RMS Energy Analyzer PS-3500 Model: PS-3500 Measures: AC Voltage, AC Current, Kilowatt, Kilowatt/Hour, Power Factor, Harmonics Description: Cat IV-compliant true RMS energy analyzer with 1000 amp current probes and voltage references for 3-phase loads. In addition to the features found on the PS3000, the meter accepts an SD card and Blutetooth connections for data transfer. Logger dimension: 3.75 in x 7.75 in x 2 in.
59/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Sensor: Range (Accuracy): - Voltage: 1 to 600 Volts rms (± 0.5%) - Frequency: 45 to 3000 Hz (± 0.5%) - AC Current: 0.01 to 6000 Amps (± 0.5% plus accuracy of probe) - Power: 1 Watt to 60 Megawatts (± 1% + accuracy of probe) - Power Factor: 0 to 1 (± 1% + accuracy of probe) - Energy & Cost: (± 1% + accuracy of probe) - Harmonic (THD): through 50th or 3000 Hz (± 1% of fundamental) Related Application Note(s): Summit Technology Powersight PS-3000
Suunto OY
Hand-bearing compass Model: kb-14/360r Measures: Magnetic Bearing, Position, Status Description: Heavy-duty precision compass balanced for use in northern hemisphere. Compass shows magnetic direction, so readings will need adjustment for local declination to obtain true directions. Sighting feature has actual and reverse reading. Sensor: Range (Accuracy): - Magnetic Bearing: 0 to 360º (± 1/6º) Related Application Note(s): Using a Suunto Compass
Suunto OY
Optical Reading Clinometer Model: PM-5/360 PC Measures: Altitude Angle, Percent Slope Description: Heavy-duty clinometer for measuring vertical angles. Clinometer has two scales: angle in degrees above or below horizontal, and percent slope. Sighting allows user to simultaneously view object and read slope. Often used to determine heights of buildings and landscape elements. Related Application Note(s): Using a Suunto Clinometer
Synergistic Control Systems
Meter/Recorder w/ Analogs Model: C180E-A-N1 Description: 2 PT, 16 CT, 16 digital input, 8 digital output, plus 15 analog input channels for monitoring 0-5 Vdc, 4-20 mA or 1000-ohm platinum RTD sensors; packaged in a 24"x12"x4" NEMA 1 enclosure.
Taylor Sling Psychrometer Model: 1328
60/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: Dry-bulb and Wet-bulb Temperature Description: Measures both dry-bulb and wet-bulb temperature. Arm pivots and rotates to allow air to move past thermometers. Has 9" tubes recessed in gray metal back. Sensor: Range (Accuracy): - Dry-bulb and Wet-bulb Temperature: 20 to 120°F (± 1%) Resolution: 1°
Tektronix
Illuminance Meter Model: J17 LumaColor Measures: Illuminance Description: This illuminance meter is cosine corrected and has a photopic correction for use with all visible light sources. Readings are in lux or footcandles. Sensor: Range (Accuracy): - Illuminance: 0.001 to 5000 fc (± 1% + 2 counts) Related Application Note(s): A Simple Illuminance Field Study
Tektronix
Luminance Head Model: J1803 Measures: Luminance Description: This luminance head is to be used with J17 photometer. It has an eight-degree angle of sensitivity and photopic correction for different light sources. Readings are in candelas per meter squared or foot-lamberts. Sensor: Range (Accuracy): - Luminance: 0.03 to 1,500,000 cd/m2 (± 1% + 2 counts)
Telaire Systems
Carbon Dioxide & Temp Monitor - 7001 Model: Telaire 7001 Measures: CO2, Temperature Description: Hand-held CO2 and Temperature monitor with digital display and push-button interface. 0 to 4 VDC output can be sent to a datalogger through an RJ-45 jack. Sensor: Range (Accuracy): - CO2: 0 to 10,000 ppm for display and 0 to 4000 ppm for voltage output (± 50 ppm or 5% of reading, whichever is greater) - Temperature: 32 to 122°F for display and 32 to 104°F voltage for output, (± 2° F) Resolution: 0.1° (Display)
Testo Combustion Analyzer 330-2 Model: 330-2
61/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: O2, CO, NO, Nox, stack gas temperature, pressure Description: Hand-held measuring device for flue gas analysis of furnace systems. Memory/Records: 400 measurements
Testo
Differential Pressure Probe Model: 0638 1547 Measures: Air Pressure Description: Differential air pressure probe for Testo 400 Multifunction Meter/Data Logger. Sensor: Range (Accuracy): - Differential Pressure: 0 to 40" H2O (± 0.04" H2O from 0 to 8" H2O) and (± 8" to 40" H2O)
Testo
Multi-Function Meter/Logger Model: 400 Description: Instantaneous meter with LCD display and data logging capability measures temperature, %RH, CO2, differential pressure, air velocity with proprietary probes. Meter has rechargeable batteries. Logger uses a PC serial interface for data transfer. Memory/Records: 500,000 records
Testo
Omni-Directional Velocity Probe Model: 0628 0035 Measures: Air velocity Description: Omni-directional hot bulb air velocity probe for measurements in the lower velocity range. Proprietary probe for use with the Testo 400 multifunction meter/data logger. Sensor: Range (Accuracy): - Air Velocity: 0 to 2000 fpm (±6 fpm ±5% of reading)
Testo
Quick Action Hot Wire Velocity Probe Model: 0635 1041 Measures: Air Velocity Description: Quick action hot wire air velocity probe for Testo 400 multifunction meter/data logger. Probe has telescopic handle with integral 5 foot cable and probe tip is 0.4" in diameter Sensor: Range (Accuracy): - Air Velocity: 0 to 20 m/s or 0 to 3900 fpm (± 0.03 m/s ±4% of reading or ± 6 fpm ±4% of reading)
Testo Reference Humidity Probe Model: 0636 9741
62/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Measures: % Relative Humidity Description: Relative humidity probe for Testo 400 multifunction meter/data logger. Sensor: Range (Accuracy): - % Relative Humidity: 0 to 100% RH (±1% RH from 10 to 90% RH) and (±2% RH from 0 to 9.9% RH) and (±2% from 90.1 to 100% RH)
Testo
RTD Immersion/Penetration Probe Model: 0604 0273 Measures: Temperature Description: RTD immersion/penetration probe for Testo 400 multifunction meter/data logger. Sensor: Range (Accuracy): - Temperature: -330 to +750 ºF (±0.15 +0.005 * reading)
Testo
Velocity Stick Model: 0560 4052 Measures: Air Velocity and Temperature Description: Hot wire anemometer stick with digital display. Stick is 11.8" long and probe stem is 0.47" in diameter. Sensor: Range (Accuracy): - Air Velocity: 0 to 1970 fpm (± 5% of m.v. ± 20 fpm to 400 fpm and ±5% of m.v. ± 60 fpm over 400 fpm) - Temperature: -4º to 120º F (± 0.9º F) Resolution: 1 fpm
Testo
Wind Vane/Temperature Velocity Sensor Probe Model: 0635 9540 Measures: Air Velocity and Temperature Description: Wind vane and temperature probe with telescopic handle that exends to a maximum of 1 meter long. For use with theTesto Muliti/Function meter. Sensor: Range (Accuracy): - Air Velocity: 78 to 11,000 fpm or 0.4 to 60 m/s (± 39 fpm ± 1% of reading or ± 0.20 m/s ± 1% of reading) - Temperature: +30º to 140º F
Tif (ATP)
4-way Manifold Gauge Set Model: TIF9600 Measures: Refrigerant Pressure Description: Gauges measure refrigerant (CFC/HCFC) pressure. Unit has 72 inch evacuation hose. Sensor: Range (Accuracy): - Pressure: Low: – 29.9 inch Hg to 250 PSI, High: 0 to 500 PSI (±2% of Mid Scale)
63/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
Resolution: Low Pressure: 1 inHg/1PSI, High Pressure: 5PSI
TOPCON Positioning
Pulse Total Station Model: GPT-2009 Measures: Topography, Distance, Height Description: Reflectorless total station surveying tool. Has non-prism and prism modes. Sensor: Range (Accuracy): - Distance: 9.8 to 328 ft (± 3 in up to 82 ft, ± 1.5 in over 82 ft) in non-prism mode; up to 13,100 ft (± .9 in) in prism mode. Accuracies decline at large distances by 1 ppm of distance.
VAISALA Oyj
Duct-mounted RH Sensor Model: hmd50u Measures: Relative Humidity (RH) Description: Three-wire humidity sensor for duct mounting. Sensor has a 0 to 1 volt DC output. Device requires 15 to 35 VDC input power, is 5/8" in diameter and measures 10" in length. Operating temperature range is 14 to 140°F. Sensor: Range (Accuracy): - Relative Humidity: 10 to 90% (± 3% at 68° F)
VAISALA Oyj
HM34F Humidity and Temperature Meter Model: HM34F Measures: Temperture and % Relative Humidity Description: Battery operated, hand-held meter with digital display for the measurement of ambient relative humidity and temperature. Sensor: Range (Accuracy): - % Relative Humidity: 0 to 100% RH (±2%RH (0 to 90%RH) and ±3%RH (0 to 100%RH)) - Temperature: -4 to 140ºF (±0.5º F)
VAISALA Oyj
HMI41 Humidity and Temperature Meter Model: HMI41 Measures: Temperature, Relative Humidity Description: Hand-held temperature and relative humidity meter with LCD display. Calculates dewpoint, wet bulb, absolute humidity and mixing ratio. Compatible with the Vaisala HMP41 or HMP45 probe. Sensor: Range (Accuracy): - Temperature: - 4° to 140° F (± 0.2 to 0.4° F) with HMP41 or HMP45 probe; - 40° to 212° F (± 0.2 to 0.6° F) with HMP42 probe - Relative Humidity: 0 to 100% (± 2% for 0 to 90% RH, ± 3% for 90 to 100% RH) - Dewpoint: - 4° to 140° F
64/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
- Wet Bulb Temperature: 32° to 140° F - Absolute Humidity: 0 to 160 g/m3 - Mixing Ratio: 0 to 160 g/Kgd.a. Resolution: Relative Humidity: 0.1% RH, Temperature: 0.1° F
VAISALA Oyj
Humidity and Temperature Probe Model: HMP45 Measures: Temperature, Relative Humidity Description: Temperature and relative humidity probe for use with the HMI41 meter. Sensor: Range (Accuracy): - Relative Humidity: 0 to 100% (± 2% for 0 to 90% RH, ± 3% for 90% to 100% RH) - Temperature: - 4° to 140° F (± 0.2 to 0.4° F)
VAISALA Oyj
Humidity Transmitter for Small Spaces Model: HMP233 Measures: Temperature and Relative Humidity (RH) Description: Two channel temperature and relative humidity transmitter with 4 to 20 mA output for measurement in tight spaces. Sensor: Range (Accuracy): - Relative Humidity: 0 to 100% (± 1% for 0 to 90% RH, ± 2% for 90% to 100% RH) - Temperature: - 40° to 140° F OR - 40° to 248° F (± 0.36° F) Compatible Data Loggers: AEC MicroDataLogger Pace Pocket Logger Pace XR5 Logger
VAISALA Oyj
RH and Temperature Probe Model: HMP45C Measures: Relative Humidity (RH), Temperature Description: Low power consumption temperature and relative humidity probe provides 0 to 1 Volt DC and RTD output signals. Can be installed into a solar radiation shield. Requires a 7 to 35 Volts DC power supply. Sensor: Range (Accuracy): - Temperature: - 38.5° to 140° F (± 0.36° F) - Relative Humidity: 0.8% to 100% (± 2%) Compatible Data Loggers: AEC MicroDataLogger Campbell CR10
65/65
PG&E Tool Lending Catalog
Mfg & Image Tool Name & Description
VAISALA Oyj
RH/Temperature Transmitter Model: HMD50Y Measures: Temperature, Relative Humidity (RH) Description: Three-wire humidity sensor and 2-wire temperature sensor for duct mounting. Requires 15 to 35 VDC input power, is 5/8" in diameter and measures 10" in length. Has selectable 0-10 or 0-1 Volt output. Can be used with energy management systems. Sensor: Range (Accuracy): - Relative Humidity: 10 to 90% (better than ± 3% at 20°C) - Temperature: -10 to 60°C or 14 to 140°F (± 0.6°C at 25°C) Compatible Data Loggers: ACR SmartReader 7 ACR SmartReader Plus 7 AEC MicroDataLogger
VAISALA Oyj
Thin Humidity and Temperature Probe Model: HMP42 Measures: Temperature, Relative Humidity Description: Temperature and relative humidity probe used for small and hard-to-reach places. For use with the Vaisala HMI41 meter. Sensor: Range (Accuracy): - Relative Humidity: 0 - 100% (± 2% for 0 to 90% RH, ± 3% for 90 to 100% RH) - Temperature: - 40° to 212° F ( ± 0.2° to 0.4° F for - 4° to 140° F, ± 0.4° to 0.6° F for - 40° to -4° F and 140° to 212° F)
Watt Stopper
InteliTimer Pro (IT-200) Model: IT-200-PC Measures: Occupancy (Motion), On/Off Status of Lights Description: Occupancy and light logger utilizes passive infrared technology and a Fresnel lens to detect occupancy in an area. Light sensor is housed in a plastic light pipe that is aimed at the source to determine if the area’s lights are on or off. Approximate logger dimension: 4.3 in x 3.5 in x 1.2 in. Memory/Records: 4096 entries Related Application Note(s): Energy Savings Potential of Occupancy Sensors