Geotechnical Investigation Update
Proposed Building271 West Hunt Club Road
Ottawa, Ontario
Prepared For
Ottawa Humane Societyc/o MHPM
July 31, 2009
Report PG1909-1
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1
July 31, 2009 Page i
TABLE OF CONTENTS
PAGE
1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.0 PROPOSED DEVELOPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3.0 REVIEW OF AVAILABLE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4.0 DISCUSSION
4.1 Geotechnical Assessment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.2 Site Grading and Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.3 Foundation Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.4 Design for Earthquakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.5 Slab on Grade Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.6 Pavement Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.0 DESIGN AND CONSTRUCTION PRECAUTIONS
5.1 Foundation Drainage and Backfill . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2 Protection of Footings Against Frost Action . . . . . . . . . . . . . . . . . . . . 9
5.3 Excavation Side Slopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.4 Pipe Bedding and Backfill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.5 Groundwater Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.6 Winter Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.7 Corrosion Potential and Sulphate . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7.0 RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
8.0 STATEMENT OF LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
APPENDICES
Appendix 1 Soil Profile and Test Data Sheets
Symbols and Terms
Analytical Testing Results
Appendix 2 Figure 1 - Key Plan
Figures 2 and 3 - Shear Wave Velocity Profiles
Drawing PG1909-1 - Test Hole Location Plan
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 1
1.0 INTRODUCTION
Paterson Group (Paterson) was commissioned by Ottawa Humane Society c/o MHPM
to update our original geotechnical investigation to current Ontario Building
Code (OBC) requirements for the proposed building to be located at 271 West Hunt
Club Road, in the City of Ottawa, Ontario (refer to Figure 1 - Key Plan in Appendix 2
of this report).
The objectives of the current investigation were to:
‘ Review existing borehole information completed on the subject and adjacent
sites to determine the subsoil and groundwater conditions.
‘ Complete a seismic shear wave velocity test to confirm seismic site class
according to OBC standards.
‘ to provide geotechnical recommendations for the design of the proposed
development including construction considerations which may affect the design.
The following report has been prepared specifically and solely for the aforementioned
project which is described herein. It contains our findings and includes geotechnical
recommendations pertaining to the design and construction of the proposed
development as they are understood at the time of writing this report.
Investigating the presence or potential presence of contamination on the subject
property was not part of the scope of work of this present investigation.
2.0 PROPOSED DEVELOPMENT
It is understood that the proposed development will consist of a single storey, steel
frame construction, slab on grade structure with associated access lanes, parking and
landscaped areas.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 2
3.0 REVIEW OF AVAILABLE INFORMATION
Based on a review of existing borehole information, the subsurface profile consists of
topsoil overlying a thin layer of silty sand/sandy silt, which in turn is overlying a deep
silty clay deposit. Glacial till was inferred to be encountered below the silty clay
deposit. Practical refusal to dynamic cone penetration testing was encountered at
18.2, 16.2 and 16.3 m depth at BHs 2, 4 and 5. Reference should be made to the Soil
Profile and Test Data sheets in Appendix 1 for specific details of the soil profile
encountered at the test hole locations.
Based on available geological mapping, the bedrock in the area of the subject site
consists of dolomite of the Oxford Formation, interbedded sandstone and dolomite of
the March Formation, or shale of the Rockliffe Formation. The overburden thickness
ranges between 15 and 50 m depth in the area of the subject site.
Groundwater levels were measured in the standpipes on April 15, 2004. The
measured groundwater levels ranged from at ground surface to 0.6 m below existing
ground surface. It should be noted that groundwater level readings could be influenced
by surface water infiltrating the backfilled borehole. Groundwater conditions can also
be estimated based on the observed colour and consistency of the recovered soil
samples. Based on these observations, it is estimated that the long term groundwater
table can be expected between a 2.5 and 4 m depth.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 3
4.0 DISCUSSION
4.1 Geotechnical Assessment
From a geotechnical perspective, the subject site is suitable for the proposed building.
It is expected that footings will be placed on undisturbed, stiff to very stiff silty clay.
The above and other considerations are discussed in the following paragraphs.
4.2 Site Grading and Preparation
Stripping Depth
Topsoil and deleterious fill, such as those containing organic materials, should be
stripped from under the building and other settlement sensitive structures.
Fill Placement
Fill used for grading beneath the proposed building, unless otherwise specified, should
consist of clean imported granular fill, such as Ontario Provincial Standard
Specifications (OPSS) Granular A or Granular B Type II. The fill should be tested and
approved prior to delivery to the site. It should be placed in lifts no greater than
300 mm thick and compacted using suitable compaction equipment for the lift
thickness. Fill placed beneath the building areas should be compacted to at least 98%
of its standard Proctor maximum dry density (SPMDD).
Non-specified existing fill along with site-excavated soil can be used as general
landscaping fill where settlement of the ground surface is of minor concern. These
materials should be spread in thin lifts and at least compacted by the tracks of the
spreading equipment to minimize voids. If these materials are to be used to build up
the subgrade level for areas to be paved, they should be compacted in thin lifts to a
minimum density of 95% of their respective SPMDD. Non-specified existing fill and
site-excavated soils are not suitable for use as backfill against foundation walls, unless
used in conjunction with a geocomposite drainage membrane, such as Miradrain
G100N or Delta Drain 6000.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 4
4.3 Foundation Design
Shallow Foundation
Footings can be designed using a bearing resistance value at serviceability limit states
(SLS) of 150 kPa and a factored bearing resistance value at ultimate limit states (ULS)
of 300 kPa placed on an undisturbed, stiff to very stiff silty clay crust. A geotechnical
resistance factor of 0.5 was applied to the above noted bearing resistance value at
ULS. The bearing resistance value at SLS will be subjected to potential post-
construction total and differential settlements of 25 and 20 mm, respectively.
An undisturbed soil bearing surface consists of a surface from which all topsoil and
deleterious materials, such as loose, frozen or disturbed soil, whether in situ or not,
have been removed, in the dry, prior to the placement of concrete for footings.
The bearing medium under footing-supported structures is required to be provided with
adequate lateral support with respect to excavations and different foundation levels.
Adequate lateral support is provided to a glacial till bearing medium when a plane
extending down and out from the bottom edge of the footing at a minimum of 1.5H:1V,
passes only through in situ soil or engineered fill of the same or higher capacity as the
soil.
Due to the presence of a deep deposit of silty clay, a permissible grade raise of 1.5 m
is applicable to the subject site.
4.4 Design for Earthquakes
Paterson field personnel placed 24 horizontal geophones in a straight line in roughly
an east-west orientation. The 4.5 Hz. horizontal geophones were mounted to the
surface by means of a 75 mm ground spike attached to the geophone land case. The
geophones were spaced at 3 m intervals and were connected by a geophone spread
cable to a Geode 24 Channel seismograph.
The seismograph was also connected to a computer laptop and a hammer trigger
switch attached to a 12 pound dead blow hammer. The hammer trigger switch sends
a start signal to the seismograph. The hammer is used to strike an I-Beam seated into
the ground surface, which creates a polarized shear wave. The hammer shots are
repeated between four (4) to eight (8) times at each shot location to improve signal to
noise ratio. The shot locations are also completed in forward and reverse directions
(ie.- striking both sides of the I-Beam seated parallel to the geophone array). The shot
locations are located at the centre of the geophone array and 3, 4.5 and 30 m away
from the first and last geophone.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 5
The methods of testing and analysis completed by Paterson are guided by the
standard testing procedures used by the expert seismologists at Carleton University
and Geological Survey of Canada (GSC). It should also be noted that this testing and
analysis method was further utilized by Carleton University and GSC to complete the
Seismic Hazard Microzonation in the Ottawa Region project.
Data Processing and Interpretation
Interpretation for the shear wave velocity results were completed by Paterson
geotechnical personnel. The shear wave velocity measurement was made using
reflection/refraction methods. The interpretation is performed by recovering arrival
times from direct and refracted waves. The interpretation is repeated at each shot
location to provide an average shear wave velocity, Vs30, of the upper 30 m profile.
The layer intercept times, velocities from different layers and critical distances are
interpreted from the shear wave records. Two (2) shear wave velocity profiles are
presented in Appendix 2.
Based on our interpretation, two (2) distinct shear wave velocities were noted from
different layers. Layer 2 was noted to extend to beyond a 30 m depth.
Table 1 - Shear Wave Velocity Results
Trigger Source
Location (m)
Overburden - Layer 1 Overburden - Layer 2
Vs (m/s) Depth (m) Vs (m/s)
-30 138 11.5 234
-4.5 119 9.9 249
-3 122 8.9 223
72 121 11.0 264
73.5 129 11.0 236
99 129 8.9 213
Layer 1 Avg. Vs
126 m/s
Layer 1 -
Avg. Depth 10.2 m
Layer 2 Avg. Vs
237 m/s
Note: ‘ The trigger source locations are representative of the recorded distance with respect to the
first geophone location of the geophone array.
‘ Interpretation of results from shot location 34.5 was not possible, so the data was ignored
in our analysis.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 6
The Vs30 was calculated using the standard equation for average shear wave velocity
calculation from the Ontario Building Code (OBC) 2006.
VDepth m
Depth m
Vs m s
Depth m
Vs m s
Vm
m
m s
m
m s
V m s
s
OfInterest
Layer
Layer
Layer
Layer
s
s
30
1
1
2
2
30
30
30
10 2
126
19 8
237
182
=
+
=
+
=
∑
∑
( )
( ( )
( / )
( )
( / )
.
/
.
/
/
Based on the results of the seismic testing, the average shear wave velocity of the
upper 30 m profile, Vs30, was calculated to be 182 m/s. Therefore, a seismic Site
Class D is applicable for the subject site as per Table 4.1.8.4.A of the OBC 2006.
4.5 Slab on Grade Construction
With the removal of all topsoil and fill, containing organic materials, within the footprint
of the proposed building, the native soil surface will be considered to be an acceptable
subgrade surface on which to commence backfilling for slab on grade construction.
Any soft areas should be removed and backfilled with appropriate backfill material.
OPSS Granular A or Granular B Type II, with a maximum particle size of 50 mm, are
recommended for backfilling below the floor slab. It is recommended that the upper
200 mm of sub-floor fill consists of OPSS Granular A crushed stone. All backfill
materials within the footprint of the proposed buildings should be placed in maximum
300 mm thick loose layers and compacted to at least 98% of its SPMDD.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 7
4.6 Pavement Structure
For design purposes, the pavement structure presented in the following tables could
be used for the design of car only parking areas and access lanes.
Table 2 - Recommended Pavement Structure - Car Only Parking Areas
Thickness
(mm)
Material Description
50 Wear Course - Superpave 12.5 Asphaltic Concrete
150 BASE - OPSS Granular A Crushed Stone
300 SUBBASE - OPSS Granular B Type II
SUBGRADE - Either in situ silty clay or OPSS Granular B Type I or II material placed over in situ soil
Table 3 - Recommended Pavement Structure - Access Lanes
Thickness
(mm)Material Description
40 Wear Course - Superpave 12.5 Asphaltic Concrete
50 Binder Course - Superpave 19.0 Asphaltic Concrete
150 BASE - OPSS Granular A Crushed Stone
400 SUBBASE - OPSS Granular B Type II
SUBGRADE - Either in situ silty clay or OPSS Granular B Type I or II material placed over in situ soil
Minimum Performance Graded (PG) 58-34 asphalt cement should be used for this
project.
If soft spots develop in the subgrade during compaction or due to construction traffic,
the affected areas should be excavated and replaced with OPSS Granular B Type I or
II material.
The pavement granular base and subbase should be placed in maximum 300 mm thick
lifts and compacted to a minimum of 100% of the material’s SPMDD using suitable
vibratory equipment.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 8
Pavement Structure Drainage
Satisfactory performance of the pavement structure is largely dependent on keeping
the contact zone between the subgrade material and the base stone in a dry condition.
Due to the impervious nature of the subgrade materials, consideration should be given
to installing subdrains during the pavement construction. These drains should be
installed at each catch basin as per City of Ottawa standards and specifications. The
subdrain inverts should be approximately 300 mm below subgrade level. The
subgrade surface should be crowned to promote water flow to the drainage lines.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 9
5.0 DESIGN AND CONSTRUCTION PRECAUTIONS
5.1 Foundation Drainage and Backfill
It is recommended that a perimeter foundation drainage system be provided for the
proposed structure. The system should consist of a 100 to 150 mm diameter
perforated corrugated plastic pipe, surrounded on all sides by 150 mm of 10 mm clear
crushed stone, placed at the footing level around the exterior perimeter of the structure.
The pipe should have a positive outlet, such as a gravity connection to the storm
sewer.
Backfill against the exterior sides of the foundation walls should consist of free-draining
non frost susceptible granular materials. The greater part of the site excavated
materials will be frost susceptible and, as such, are not recommended for re-use as
backfill against the foundation walls, unless used in conjunction with a drainage
geocomposite, such as Miradrain G100N or Delta Drain 6000, connected to the
perimeter foundation drainage system. Imported granular materials, such as clean
sand or OPSS Granular B Type I granular material, should otherwise be used for this
purpose.
5.2 Protection of Footings Against Frost Action
Perimeter footings of heated structures are required to be insulated against the
deleterious effect of frost action. A minimum of 1.5 m thick soil cover (or equivalent)
should be provided in this regard.
A minimum of 2.1 m thick soil cover (or equivalent) should be provided for exterior
unheated footings, not thermally connected to a heated space, such as exterior
columns and/or wing walls.
5.3 Excavation Side Slopes
The side slopes of excavations in the soil and fill overburden materials should either
be cut back at acceptable slopes or should be retained by shoring systems from the
start of the excavation until the structure is backfilled. It is assumed that sufficient room
will be available for the greater part of the excavation to be undertaken by open-cut
methods (i.e. unsupported excavations).
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 10
The excavation side slopes above the groundwater level extending to a maximum
depth of 3 m should be cut back at 1H:1V or flatter. The flatter slope is required for
excavation below groundwater level. The subsoil at this site is considered to be mainly
a Type 2 and 3 soil according to the Occupational Health and Safety Act and
Regulations for Construction Projects.
Excavated soil should not be stockpiled directly at the top of excavations and heavy
equipment should be kept away from the excavation sides.
Slopes in excess of 3 m in height should be periodically inspected by the geotechnical
consultant in order to detect if the slopes are exhibiting signs of distress.
It is recommended that a trench box be used at all times to protect personnel working
in trenches with steep or vertical sides. It is expected that services will be installed by
“cut and cover” methods and excavations will not be left open for extended periods of
time.
5.4 Pipe Bedding and Backfill
At least 150 mm of OPSS Granular A should be used for pipe bedding for sewer and
water pipes. The bedding should extend to the spring line of the pipe. Cover material,
from the spring line to at least 300 mm above the obvert of the pipe should consist of
OPSS Granular A. The bedding and cover materials should be placed in maximum
225 mm thick lifts compacted to a minimum of 95% of the material’s SPMDD.
Generally, it should be possible to re-use the silty clay crust above the cover material
if the excavation and filling operations are carried out in dry weather conditions.
Where hard surface areas are considered above the trench backfill, the trench backfill
material within the frost zone (about 1.8 m below finished grade) should match the soils
exposed at the trench walls to minimize differential frost heaving. The trench backfill
should be placed in maximum 300 mm thick loose lifts and compacted to a minimum
of 95% of the material’s SPMDD.
To reduce long-term lowering of the groundwater level at this site, clay seals should be
provided in the service trenches. The clay seals should be as per Standard Drawing
No. S8 of the Department of Public Works and Services, Infrastructure Services Branch
of the City of Ottawa. The seals should be at least 1.5 m long (in the trench direction),
as compared to the 1 m minimum in the detail, and should extend from trench wall to
trench wall. Generally, the seals should extend from the frost line and fully penetrate
the bedding, subbedding and cover material.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 11
The barriers should consist of relatively dry and compactable brown silty clay placed
in maximum 225 mm thick loose layers and compacted to a minimum of 95% of the
material’s SPMDD. The clay seals should be placed at the site boundaries and at
strategic locations at no more than 60 m intervals in the service trenches.
5.5 Groundwater Control
The contractor should be prepared to direct water away from all bearing surfaces and
subgrades, regardless of the source, to prevent disturbance to the founding medium.
It is anticipated that pumping from open sumps will be sufficient to control the
groundwater influx through the sides of the excavations.
A temporary MOE permit to take water (PTTW) will be required for this project if more
than 50,000 L/day are to be pumped during the construction phase. At least 5 to
6 months should be allowed for completion of the application and issuance of the
permit by the MOE.
5.6 Winter Construction
Precautions must be taken if winter construction is considered for this project. The
subsoil conditions at this site consist of frost susceptible materials. In the presence of
water and freezing conditions, ice could form within the soil mass. Heaving and
settlement upon thawing could occur.
In the event of construction during below zero temperatures, the founding stratum
should be protected from freezing temperatures by the use of straw, propane heaters
and tarpaulins or other suitable means. In this regard, the base of the excavations
should be insulated from sub-zero temperatures immediately upon exposure and until
such time as heat is adequately supplied to the building and the footings are protected
with sufficient soil cover to prevent freezing at founding level.
Trench excavations and pavement construction are also difficult activities to complete
during freezing conditions without introducing frost in the subgrade or in the excavation
walls and bottoms. Precautions should be taken if such activities are to be carried out
during freezing conditions.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 12
5.7 Corrosion Potential and Sulphate
The results of analytical testing show that the sulphate content is less than 0.1%. This
result is indicative that Type 10 Portland cement (normal cement) would be appropriate
for this site. The chloride content and the pH of the sample indicate that they are not
significant factors in creating a corrosive environment for exposed ferrous metals at this
site, whereas the resistivity is indicative of a low to moderately aggressive corrosive
environment.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 13
6.0 RECOMMENDATIONS
It is a requirement for the foundation design data provided herein to be applicable that
a materials testing and observation services program including the following aspects
be performed by the geotechnical consultant.
‘ Observation of all bearing surfaces prior to the placement of concrete.
‘ Sampling and testing of the concrete and fill materials used.
‘ Periodic observation of the condition of unsupported excavation side slopes in
excess of 3 m in height, if applicable.
‘ Observation of all subgrades prior to backfilling and follow-up field density tests
to determine the level of compaction achieved.
‘ Sampling and testing of the bituminous concrete including mix design reviews.
A report confirming that these works have been conducted in general accordance with
our recommendations could be issued, upon request, following the completion of a
satisfactory materials testing and observation program by the geotechnical consultant.
paterson Geotechnical Investigation UpdateOttawa Kingston North Bay Proposed Building
271 West Hunt Club Road - Ottawa
Report: PG1909-1July 31, 2009 Page 14
7.0 STATEMENT OF LIMITATIONS
The recommendations made in this report are in accordance with our present
understanding of the project. The client should be aware that any information
pertaining to soils and all test hole logs are furnished as a matter of general information
only and test hole descriptions or logs are not to be interpreted as descriptive of
conditions at locations other than those of the test holes.
The recommendations provided herein should only be used by the design
professionals associated with this project. They are not intended for contractors
bidding on or undertaking the work.
The present report applies only to the project described in this document. Use of this
report for purposes other than those described herein or by person(s) other than
Ottawa Humane Society, MHPM or their agent(s) is not authorized without review by
this firm for the applicability of our recommendations to the altered use of the report.
Paterson Group Inc.
David J. Gilbert, P.Eng.
Carlos P. Da Silva, P.Eng.
Report Distribution:
‘ Ottawa Humane Society c/o MHPM (3 copies)
‘ Paterson Group (1 copy)
APPENDIX 1
SOIL PROFILE AND TEST DATA SHEETS
SYMBOLS AND TERMS
ANALYTICAL TESTING RESULTS
APPENDIX 2
FIGURE 1 - KEY PLAN
FIGURES 2 AND 3 - SHEAR WAVE VELOCITY PROFILES
DRAWING PG1909-1 - TEST HOLE LOCATION PLAN
FIGURE 1
KEY PLAN
SITE
Figure 2 – Shear Wave Velocity Profile at -30 m Shot Location
Figure 3 – Shear Wave Velocity Profile at 73.5 m Shot Location