  • The Semicircular Lipoatrophy-

    FINAL DEGREE PROJECT

    THE SEMICIRCULAR LIPOATROPHY (LS)

    ASSOCIATED WITH THE CURRENT BUILDING

    - Datasheets for construction and building rehabilitation-

    Designer/s: Jos Daniel Alcalde Morn/Valdric Farr Judas

    Tutor/s: Enric Aul Mellado

    Official announcement: February 2011

  • FDP 2011 The Semicircular Lipoatrophy-

    1

    INDEX

    1. Preventive measures related to the semicircular lipoatrophy in existing

    buildings. protocol of action.........................................................page. 2.

    2. Preventive measures related to the semicircular lipoatrophy in new

    construction buildings. protocol of actionpage. 8.

    3. Datasheet for control building work in progress. Checklist of measures

    adopted in project to anticipate the appearance of the semicircular

    lipoatrophy................................................................................page. 11.

    4. Datasheet for finished building work. Checklist of measures adopted in project

    to anticipate the appearance of the semicircular lipoatrophy. .........page. 14

    5. Possible solutions of action. ........................................................page. 17.

  • FDP 2011 The Semicircular Lipoatrophy-

    2

    1. PREVENTIVE MEASURES RELATED TO THE SEMICIRCULAR

    LIPOATROPHY IN EXISTING BUILDINGS. PROTOCOL OF

    ACTION.

    This protocol has been designed to evaluate rooms and working places in existing

    buildings, taking a look at the rehabilitation of them. The aim of this evaluation is

    to study the indoor rooms, valuing the current characteristics and seeing the

    potential dangerous agents, which can influence to the appearance of the

    semicircular lipoatrophy.

    Basically we try to study the air conditioning, ventilation, humidity and the indoor

    building rooms, also analyzing the existing office equipment and office furniture.

    This study should be accompanied of thermohigrometric, electrostatic and

    electromagnetic initial valuation, to check if the indoor rooms conditions are

    adequated or not. These results obtained, need to be interpreted as an indication

    of the building conditions, and allows us to anticipate the needs of intervention if

    needed, directed to the appropriate rehabilitation of it.

    The assessment results are necessary to be related with environmental aspects

    that we have mentioned at section A in the original project, and the acceptance

    or not of the values, will be realized as a check-list .

  • FDP 2011 The Semicircular Lipoatrophy-

    3

    DATASHEET 1- EXISTING BUILDINGS PROTOCOL OF ACTION AND PREVENTIVE RELATED MEASURES

    Working place Identification of the working place*:

    * The working place has to be unequivocally identifiable for the company Workplace description: Recent changes in the working place (in the last year) Date: Recent change of building Recent change of furniture Type of changed furniture: Ventilation Forced Natural

    Windows that are possible to open Yes No

    Air conditioning Integrated in the ventilation system Not integrated in the ventilation system

    Humidifier Yes No

    Humidifier Portable Integrated in the ventilation system Independent of the ventilation system

    Electrical installation - wiring Across the floor Trough the wall In columns d

    Additional wiring insulation of the metallic structure of the desk

    Yes No

    Equipments of work PC desktops Yes No

    PC portable Yes No

    Printer / scanner Yes No

    Others Yes No

    CPU position On the Desk Under the Desk, on the floor Under the Desk, placed in a metallic structure

    Printer position On the Desk Centralized

    Presence of special equipment Mobile phones amplifiers Radio Stations Yes Yes No No

  • FDP 2011 The Semicircular Lipoatrophy-

    4

    DATASHEET 1- EXISTING BUILDINGS Desk

    Structure

    Metallic Not metallic

    Wiring gathered support

    Yes No

    Surface Wood Synthetic resin Others:

    Edge Narrow and angular Wide and angular Wide and rounded

    Ground leading Yes No

    Grouped desks Yes No

    There are dividers between desks Yes No

    Pavement Natural (wood, others) Carpet Metallic Synthetic Ceramic, marble, stoneware Antistatic floor treatment Yes No

    Chair Cover of the chair Natural textile Synthetic textile Plastic

    Chair with wheels Yes No

    Antistatic chair On the back On the seat At the wheels

    Footrest Structure Metallic Not metallic

    Antistatic footrest Yes No

    Contact or continuous pressure Its known the existence of continuous pressure Yes No Contact with the edge of the desk Contact with the bottom bar of the desk Contact with other types of furniture Specify other kind of furniture

  • FDP 2011 The Semicircular Lipoatrophy-

    5

    DATASHEET 2- EXISTING BUILDINGS

    MEASUREMENTS MADE INSIDE THE INDOOR ROOM Date measurement: Year of construction: Other relevant aspects:

    Thermohigrometic Conditions Measuring equipment: Termohigrometer with the probes of temperature, related to humidity and the air speed. Floor: Workplace: Indoor relative humidity: % Outdoor relative humidity: % Indoor temperature: C Outdoor temperature: C Air speed: (m/s)

    Electrostatic charges Measuring equipment: Electrostatic charges meter. Floor: Workplace: Indoor relative humidity: % Form of generation: Electrostatic charges:

    Electromagnetic fields Measuring equipment: Electromagnetic field meter: electrical field (V/m) and magnetic field (A/m). Floor: Workplace: Electrical field: (V/m) Magnetic field: (mA/m o T Frequency: Hz

    Electrical installation Measuring equipment: Ohmmeter. Suitable electrical installation Yes No Absence of multiple connected plugs

  • FDP 2011 The Semicircular Lipoatrophy-

    6

    DATASHEET 3- EXISTING BUILDINGS STUDY OF THE MEASURED VALUES AND THE SOLUTIONS TO CARRY OUT

    Date measurement: Year of construction: Other relevant aspects:

    Thermohigrometic Conditions

    Concept Required Values

    Not compliance of

    required values

    Possible Solutions

    Indoor relative humidity

    47-52%

    Yes No

    52% - Installation of sensors to automate the air conditioning system.

    Indoor temperature

    Spring / Summer: 20-24C

    Autumn / Winter: 23-26C

    Yes No

    Spring/Summer:

    >20-24C - Contribution of air conditioning to cool the room.

    Spring/Summer:

  • FDP 2011 The Semicircular Lipoatrophy-

    7

    -Usual antistatic protection and cleaning products.

    Ground connection pavement

    Yes No

    All or part of the pavement is not

    connected to earth

    -Ground connection of pavement.

    Electromagnetic fields

    Electrical field a 50 Hz - 5KV/m >5KV/m

    - Check and modify the electrical installation: installation in spike. Wire bonded. Keep away the wired up installation from the workplace. -Installation isolated in contact with furniture or near employees.

    Magnetic field a50 Hz - 100 T >100 T

    - Keep away electronic devices, computers and printers from de workplace, as well as switches, routers or wireless telephones.

    Employees habits Personal characteristics: Sex and age: Male Female Seniority of office workers in the company and in the same working place: Type of work: Standing Sat Routine or habits: Crossed legs Support feet on the chair legs To roll the chair while you're sitting Continued contact with edges of the desk or chair: Yes No Commonly used clothes: Synthetic material Cotton clothes Tight clothes Others Footwear usually used: Rubber sole Leather sole Others

  • FDP 2011 The Semicircular Lipoatrophy-

    8

    2. PREVENTIVE MEASURES RELATED TO THE SEMICIRCULAR

    LIPOATROPHY IN NEW CONSTRUCTION BUILDINGS.

    PROTOCOL OF ACTION.

    This protocol has been designed in order that in project phase and during the

    project of design, take care of the essential aspects bear in mind that we have

    developed in our study, towards the environmental factors, the electromagnetic

    fields, the finishing indoor materials as well as the specific furniture planned for

    the room.

    The operating is like a check-list to make sure that we satisfy the obligatory to

    include the aspects to study in the project. Once we studied the different points,

    we should check thus .

  • FDP 2011 The Semicircular Lipoatrophy-

    9

    DATASHEET 4-NEW BUILDINGS MEASURES TO ADOPT DURING THE DESIGN OF OFFICE BUILDINGS TO PREVENT THE APPEARANCE OF SEMICIRCULAR LIPOATROPHY PROJECT

    Points of considering Items

    Possible solutions to include in the project

    Required / Optional

    Environmental criteria

    Relative humidity between

    47-52%

    Air conditioning installation

    Centralized control of air conditioning system. REQUIRED.

    Humidifiers installed. In case of Hr

  • FDP 2011 The Semicircular Lipoatrophy-

    10

    floor triboelectric materials.

    Increment of its conductivity with surface treatments. REQUIRED

    Cleaning and antistatic products. REQUIRED

    Apertures to the South, South-East or South-

    West

    Curtains or vinyls. REQUIRED

  • FDP 2011 The Semicircular Lipoatrophy-

    11

    3. DATASHEET FOR CONTROL BUILDING WORK IN

    PROGRESS. CHECKLIST OF MEASURES ADOPTED IN

    PROJECT TO ANTICIPATE THE APPEARANCE OF THE

    SEMICIRCULAR LIPOATROPHY.

    The next datasheet has been designed in order that in phase of work and during

    the works of execution, it is established that defined elements in project, will be

    really carried out with all the appropriated extension. We expect to do an

    exhaustive follow-up for the adequacy or not of the finishing surface indoor

    materials, and the electrical and air conditioning facilities, as well as the furniture

    that is being installed.

    This form will be necessary filled before, with the defined elements in project and

    also with the elements that really are going to be executed, giving later

    conformity to what it is being executed during the works .

  • FDP 2011 The Semicircular Lipoatrophy-

    12

    DATASHEET 5-NEW BUILDING CONTROL OF EXECUTION WORKS ABOUT ADOPTED MESURES IN PROJECT TO

    PREVENT THE APPEARANCE OF SEMICIRCULAR LIPOATROPHY

    Items Defined in project Executed Co

    nfo

    rmit

    y

    Finishing surface indoor materials

    Metallic floor Ground connection.

    Not metallic floor

    Good conductors and not triboelectric materials.

    Increment of its conductivity with surface treatments.

    Cleaning and antistatic products.

    Walls

    Sun protection at South, South-East or South-West apertures

    Curtains

    Vinyls

    Air conditioning system

    Centralized control of air conditioning system.

    Installation of humidifiers.

    Installation of enthalpy exchangers joined to the air renovation.

    Installation of hygroscopic sensors to automate the air conditioning system.

    Electrical installation

    Installation wire in spike.

    Installation isolated in contact with furniture or near employees.

    Ground connection

    Metallic floor.

    Ground connection for desks and chairs.

    Office furniture

    Desk Surface material.

    Material of structure.

    Chairs Metallic structure electrically connected to wheels which

  • FDP 2011 The Semicircular Lipoatrophy-

    13

    conduct electricity.

    Seats made of not triboelectric material and good electricity conductor.

    Footrests Conductor of electricity to the ground.

  • FDP 2011 The Semicircular Lipoatrophy-

    14

    4. DATASHEET FOR FINISHED BUILDING WORK. CHECKLIST

    OF MEASURES ADOPTED IN PROJECT TO ANTICIPATE THE

    APPEARANCE OF THE SEMICIRCULAR LIPOATROPHY.

    This datasheet has been designed for taking some thermohigrometic,

    electrostatic and electromagnetic measures to verify the suitable indoor

    conditions of building, once the work is ended. The results obtained must be

    treated as a faithful reflection of the reality, that is taking place and the

    environmental values that could affect directly people who develops his

    professional activity.

    It is necessary to study the results and be related following the environmental

    criteria checking the compliment or incompliment throw the obtained values. Its

    possible that it would be necessary to modify the thermohigrometic, electrostatic

    and electromagnetic conditions.

    The acceptance or not of the values are realized as a check-list .

  • FDP 2011 The Semicircular Lipoatrophy-

    15

    DATASHEET 6-NEW BUILDING CONTROL OF FINISHED WORK ABOUT MESURES TAKEN TO PREVENT THE

    APPEARANCE OF SEMICIRCULAR LIPOATROPHY MEASURES TO CHECK INSIDE THE BUILDING

    Date measurement: Thermohigrometic Conditions

    Floor: Workplace: Indoor relative humidity: % Outdoor relative humidity: % Indoor temperature: C Outdoor temperature: C

    Electrostatic charges Floor: Workplace: Indoor relative humidity: % Form of generation: Electrostatic charges:

    Electromagnetic fields Floor: Workplace: Electrical field: (V/m) Magnetic field: (mA/m o T Frequency: Hz

    Electrical installation Suitable electrical installation. Yes No

    STUDY THE MEASURED VALUES AND SOLUTIONS TO ADOPT Date measurement:

    Thermohigrometic Conditions

    Concept Required Values

    Not compliance of

    required values

    Check de possible solutions adopted in project or propose

    others

    Indoor relative humidity

    47-52%

    Yes No

    52% - Installation of sensors to automate the air conditioning system. Indoor Spring / Spring/Summer: -Contribution of air conditioning to

  • FDP 2011 The Semicircular Lipoatrophy-

    16

    temperature Summer: 20-24C

    Autumn / Winter: 23-26C

    Yes No

    >20-24C cool the room.

    Spring/Summer:

    5KV/m

    -Check and modify the electrical installation: installation in spike. Wire bonded. Keep away the wired up installation from the workplace. -Installation isolated in contact with furniture or near employers.

    Magnetic field a50 Hz - 100 T >100 T

    -Keep away electronic devices, computers and printers from de workplace, as well as switches, routers or wireless telephones.

    Electrostatic charges

    Furniture

    Antistatic furniture (desks,

    chairs and footrests)

    Yes No

    All or part of the furniture is not

    antistatic

    -Desk: rounded piece of plastic close to parts in contact with workers, also wide surface of contact. -Isolate the conductor lines, protected from the metallic structure. -Chair: seats made of not triboelectric material and good electricity conductor.

    Furniture connected to

    earth (desks and

    chairs) Yes No

    All or part of the furniture is not connected to

    earth

    -Desk: metallic structure to ground connection. -Chair: metallic structure electrically connected to wheels which conduct electricity.

    Pavement

    Antistatic pavement

    100V

    -Not metallic floor: -Good conductors and not triboelectric materials. -Increment of its conductivity with surface treatments. -Cleaning and antistatic products.

    Ground connection pavement

    Yes No

    All or part of the pavement is not

    connected to earth

    -Metallic floor:

    - Ground connection.

  • FDP 2011 The Semicircular Lipoatrophy-

    17

    5. POSSIBLE SOLUTIONS OF ACTION.

    Environmental criteria

    Centralized control of the air conditioning system

    It would be very advisable the fact of centralizing the system of air conditioning,

    controlling thus the global conditions of the building.

    Installation of humidifiers.

    In case the relative humidity is lower than the recommended, its possible to

    install humidifiers to raise it.

    Installation of sensors to automate the air conditioning system.

    To be able to control the relative humidity in an automated and exhaustive way,

    its recommended to install hygroscopic sensors to obtain an historical report,

    also keeping constant the humidity. The machine will be turned on automatically

    when one of the sensors detects a lower value than the estimated.

    Installation of enthalpy exchangers joined to the renovation of the air.

    Instead of the crossed conventional interchangers, the installation of enthalpys

    interchangers in the room, allow the air renovation. It also could recover the air

    humid load returned and also keep a higher relative humidity in a natural way.

    Design of the furniture

    Desks

    Rounded edges with a large surface of contact or protect with a rounded piece of

    plastic,to isolate the metallic structure in contact with the employee.

    Metallic structure ground connected

    To obtain a better dissipation of the static loads, it is necessary to connect the

    desk to the electrical ground line connection of the building.

    Isolation of the electrical installation in contact to the metallic structure

    Improving the electrical isolation of the wired, related to the desk, its influence

    will be reduced.

  • FDP 2011 The Semicircular Lipoatrophy-

    18

    Chairs

    Metallic structure electrically connected to wheels which conduct electricity

    The chair with a conductor line installed both at the armrests and at the metallic

    structure, its is discharged throw a conductive leg, removing the electrostatic

    load.

    Seats made of not triboelectric material and good electricity conductor

    Seats must be made with a dissipative and not triboelectric material, that is to

    say that avoids generating electrical loads in the human body. For that reason it

    should be used pieces of cotton commercialized as antistatic, avoiding articles

    with synthetic fibers, silk, rayon, wool, etc.

    Footrest

    Another measure to improve the conductivity of the materials from the

    workplace, it is possible to install footrests that lead the electricity to the ground,

    hereby lets dissipate the electrostatic loads. The conductive floor combined with

    a conductive footwear, in order that the human body remains ground connected

    surely. The top limit resistance of the conductive footwear about static electricity

    must be 1,5105 W.

    Design of finishing surface materials

    Metallic floor

    Ground connection

    To assure the dissipation of the electrostatic loads from the furniture and office

    workers, its necessary to connect the metallic elements in the ground connection

    line of the building.

    Not metallic floor

    Good conductors and not triboelectrics

    To allow the dissipation of the electrostatic loads from the furniture and office

    workers, insulating surfaces cannot be placed. Also it is necessary to bear in

    mind, not to use triboelectrics materials.

  • FDP 2011 The Semicircular Lipoatrophy-

    19

    Increase of the conductivity with superficial treatments

    The superficial treatment is realized generally with the application of prepared

    antistatic mixtures, added to the detergents, paintings, lubricants, impregnants

    and other substances, to increase the superficial conductivity to favor the

    formation of a hygroscopic conductive film. Its possible to use commercial

    antistatic products, in dissolution with water for an application in synthetic

    insulating floor, for a soft washing-up with mop or antistatic humid cloth with the

    dissolution. The film hereby created is soluble in water usually wear down with

    the use, so it is necessary to realize the treatment almost daily, though it is

    acceptable if it is done weekly.

    Cleanliness with antistatic products

    To reduce the aptitude to generate electrostatic loads as well as to increase his

    conductivity, its necessary to clean with antistatic products the floor with few

    conductivity, specially at the toilets and in the bar.

    Apertures to the South, South-East or South-West

    Curtains or vinyls

    In the zones of the building orientated to the south-east, south and west there is

    normally a high sunstroke that increases the temperature of these areas and

    therefore it reduces the relative dampness. To solve this problem its necessary

    to install curtains and vinyls to reduce the sunstroke and stabilize the relative

    humidity.