1 PULVERIZED COAL (PC) FIRED FURNACE Unit 24-25 A PC boiler plant Pulverized coal fired boiler Most widely used coal fired plant in the world. Coal, ground to 75% below 74 micron, burns like gas • Types: 1. Wet bottom (slagging) 2. Dry bottom (85% fly ash) 3. Front fired 4. Tangential fired STOKER FIRED BOILER (1800)

PF Furnace'12.pdf

Embed Size (px)

DESCRIPTION

Tangential Burner - How it works

Citation preview

Page 1: PF Furnace'12.pdf

1

PULVERIZED COAL (PC) FIRED FURNACE

Unit 24-25

A PC boiler plant

Pulverized coal fired boiler

•  Most widely used coal fired plant in the world. Coal, ground to 75% below 74 micron, burns like gas

•  Types: 1. Wet bottom (slagging) 2. Dry bottom (85% fly ash) 3. Front fired 4. Tangential fired

STOKER    FIRED    BOILER  (1800-­‐)  

Page 2: PF Furnace'12.pdf

2

435 MWe tangential fired PF

Tangential burner- Plan view

Tangential flame - Front view Heat release rates

•  Volumetric heat release rate:

(1)

•  wf = kg/s fuel burnt, Vf = furnace volume, m3; LHV = lower heating value, KJ/kg

•  Grate heat release rate (2)

Af = a x b

qv =wf LHVVf

kW/m3

qF =wf LHVAf

kW/m2

Page 3: PF Furnace'12.pdf

3

Typical values of Vol. Heat release rate, qv Boiler & Burner p- 121-122

Coal Type Dry-bottom furnace

MW/m3

Anthracite 0.110-0.140 Semi anthracite 0.116-0.163

Bituminous 0.14-0.20 Lignite 0.09-0.15

Oil (utility boiler) 0.23-0.35

Biomass 0.024 – 0.176*

Gas 0.35

* Grate heat release rate for PF boiler for biomass is highly subjective as Pf boiler are not designed to fire biomass

Furnace size depends on Fuel Amount of flue gas, burning rate of fuel & slagging propensity also affects furnace volume.

Following diagram is for comparison. Not to be used for design

Furnace volume is shown by hatched area

Superheater

Upper limits of Average Grate heat release rate, qF Steaming

capacity Upper limit of qF in MW/m2

(ST= Softening Temperature)

(tons/h)* ST ≤1300 °C ST =1300°C ST≥1300 °C

130 2.13 2.56 2.59 500 3.91 4.65 5.44

1000 4.42 5.12 6.16 1500 4.77 5.45 6.63

Biomass 1.5-3.5 • One ton/h steam is roughly equivalent to 0.75 MW heat input

• To get the electrical power output (MWe) of the plant multiply heat input with (plant efficiency/100), which gives 1 t/h approx equal to 0.3 MWe.

Page 4: PF Furnace'12.pdf

4

Minimum depth of furnace (bminimum)

Steaming capacity (t/h)

130 220 420 670 >670

Coal (m) 6.0 7.0 7.5 8.0 ≥(5-6)dr *

Oil (m) 5.0 5.0 6.0 7.5 5

dr *-maximum nozzle diameter of swirl burner

Note: A square cross-section is good for tangential firing. However the depth must not be shallower than the above limit

It ensures that flame does not hit the wall facing the burner causing damage

Shortest distance between burner and Heating surface (Hfu)

Boiler capacity (t/h)

65-75 130 220 420 670

Anthracite (m) 8 11 13 17 18

Bituminous (m) 7 9 12 14 17

Oil (m) 5 8 Hfu is the height between top of the burner zone and superheater section

It avoids any potential flame impingement on the Superheaters hanging from the wall, which might rupture the tubes

Burner region heat release rate, qb

Fuel qb in MW/m2

Brown coal & Bituminous coal 0.93 -1.16 Anthracite and semi-anthracite 1.4 - 2.1

Lignite 1.4 - 2.32

B.LHV = Furnace heat release in MW

It ensures that the peak heat flux and temperature is not too high to cause dry out and other severe conditions in wall

MW/m2

qb =

wf LHV2(a+ b)Hb