Photo/isometric drawing provided by manufacturer Permavent Graphite Description of Product This is an assessment of a breather membrane that allows the passage of water vapour through it whilst preventing liquid water to pass through it. Key Factors Assessed Mechanical Resistance & Stability Health, Hygiene and Environmental Safety in Use Energy Economy and heat retention Durability serviceability and identification Validity This certificate was first issued on 16 th September 2019 and is valid until 16 th September 2020 Issue Dated 16 th September 2019 Certificate No: EW1055B

Permavent Graphite · Permavent Graphite is a strong 130g/m. ². breather membrane suitable for use in all types of domestic and commercial roofing and walling applications within

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Permavent Graphite · Permavent Graphite is a strong 130g/m. ². breather membrane suitable for use in all types of domestic and commercial roofing and walling applications within

Photo/isometric drawing

provided by manufacturer

Permavent Graphite

Description of Product

This is an assessment of a breather membrane

that allows the passage of water vapour

through it whilst preventing liquid water to

pass through it.

Key Factors Assessed

Mechanical Resistance & Stability

Health, Hygiene and Environmental

Safety in Use

Energy Economy and heat retention

Durability serviceability and identification

Validity

This certificate was first issued on 16th September 2019 and is valid until 16th September 2020

Issue Dated 16th September 2019

Certificate No: EW1055B

Page 2: Permavent Graphite · Permavent Graphite is a strong 130g/m. ². breather membrane suitable for use in all types of domestic and commercial roofing and walling applications within

Permavent Graphite is a strong 130g/m² breather membrane suitable for use in all types of domestic and commercial

roofing and walling applications within all wind zones in the UK for underlays used for specific applications as described in

BS 5534.

The zone suitability only applies where a well sealed ceiling is present, ridge height is not greater than 15m, roof pitch is

between 12.5° and 75°, site altitude is not greater than 100m and no significant site topography is present.

Page 3: Permavent Graphite · Permavent Graphite is a strong 130g/m. ². breather membrane suitable for use in all types of domestic and commercial roofing and walling applications within

LABC consider that, Permavent Graphite will meet the functional requirements of the Building

Regulations (listed below) if the criteria detailed in this certificate are met;

The Building Regulations 2010 (as amended) England & Wales

Regulation 7. (1) Materials and Workmanship

Note: The product is acceptable.

AD C Resistance to Moisture

Note: The product is acceptable.

The Building Regulations 2010 (as amended) England

None presently.

The Building Regulations 2010 (as amended) Wales

None presently.

The Building (Scotland) Regulations 2004 (as amended)

If you would like to discuss a specific use of the product in Scotland it will require an additional

assessment under the Scottish Building Regulations and accordingly you should contact the LABSS

STAS Administrator at www.labss.org

Page 4: Permavent Graphite · Permavent Graphite is a strong 130g/m. ². breather membrane suitable for use in all types of domestic and commercial roofing and walling applications within

LABC Warranty

The use of the Permavent Graphite has not been assessed to meet the requirements of the LABC

Warranty Technical Manual. If you would like to discuss a specific use please make an enquiry to

[email protected]

BRE Test BS5534 wind uplift tests for Roof Underlay 130

Polish Centre for testing and Certification Assessment of Performance report 362H 2017 Test Method in accordance with EN

1928:2002 and EN 13859-1:2010 1 edition of 14 September 2017

Polish Centre for testing and Certification Assessment of Performance report 361H 2017 Test method in accordance with EN

ISO 11925-2:2010 part 2 single flame source test 1 edition of 14 September 2017

Polish Centre for testing and Certification Reaction of Fire Classification report in accordance with EN 13501-1-2007 Date of

Issue: 14th September 2017

Zwick/Roel Tear Resistance test to PN-EN 12310-1:2001 series 1 of 3 tests and watertightness PN-EN 1928:2002 Dated 31st

August 2018

Zwick/Roel Tear Resistance test to PN-EN 12310-1:2001 series 2 of 3 tests and watertightness PN-EN 1928:2002 Dated 31st

August 2018

Zwick/Roel Tear Resistance test to PN-EN 12310-1:2001 series 3 of 3 tests and watertightness PN-EN 1928:2002 Dated 3rd

September 2018

Zwick/Roel Tensile strength Test to PN-EN 12311-2:2013 series 1 of 3 tests and watertightness to PN-EN 1928:2002 Dated 31st

August 2018

Zwick/Roel Tensile strength Test to PN-EN 12311-2:2013 series 2 of 3 tests and watertightness to PN-EN 1928:2002 Dated 31st

August 2018

Zwick/Roel Tensile strength Test to PN-EN 12311-2:2013 series 3 of 3 tests and watertightness to PN-EN 1928:2002 Dated 3rd

September 2018

Zwick/Roell Tensile strength after ageing to PN-EN 12311-2:2013

Klima C Testing to EN 12572 for breathability

Permavent Blue, 130g/m² Declaration of Performance Dated 17th September 2018