Performance Review

Static converter (SIV)

Meeting at Railway Board

On 12.05.2017

1

Page 2: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Agenda

Performance Review

Root cause analysis of failures.

Status of reliability action plan

Status of AMC by Zonal Railways

2

Page 3: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY AT A GLANCE (ALL FIRMS)

Make Population 2016-17

upto DEC

16

2015-16 2014-15

2013-

14

2012-13

AAL 960 11.39 % 13.49% 15.56% 32 % 27.5 %

Siemens 905 4.27% 5.36 % 9.0 % 10.9 % 10.3%

Medha 337 16.62% 11.19 % 9.44 % 12.5 % 9.7%

Hind 310 22.37% 18.64 % 35.79 % 18.7 % 16.9%

ABB 116 22.22% 13.16 % 35.06 % 22.2 % 26.5%

BT 53 25.16% 25.49 % 29.41 % 88.8 % 73.4%

3

Page 4: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

SIV AAL MAKE

PERFORMANCE OF M/s. AAL MAKE SIV

4

Page 5: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY AT A GLANCE (AAL)

Firm Population 2016-17

upto DEC 16

2015-16 2014-15

2013-14

2012-13

Autometers 960 11.39% 13.49% 15.56 % 32 % 27.5%

5

Page 6: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY M/s. Autometers Year wise

6

72.4

41.5

32.4

38.8

23.0

27.5

32.0

15.6 13.5

11.4

0.0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

2007-08 2008-09 2009-10 2010-11 2011-12 2012-13 2013-14 2014-15 2015-16 2016-17 (DEC)

Series1

Page 7: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Major Cause/component wise failure analysis (AAL)

SN Year Component

2010-

11

2011-

12

2012-

13

2013-

14

2014-

15

2015-

16

2016-17

1 MCU 15 18 49 56 22 18 12

2 Cooling Fan 31 38 55 57 65 21 16

3 ZCT 18 16 21 25 15 9 2

4 DCCT / CHCT 2 2 9 11 4 5 8

5 GDU card of CHBA

24 18 19 17 13 5 16

6 Misc 10 11 7 5 10 8 8

7

Page 8: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Sudden voltage changes across QCON relay contact which

leads to stucking up of QCON relay contact, hence MCU

failure.

Action plan Status

1. Providing RC damping network

across Q-CON relay.

2. Increasing higher rating of Reed

relay with 2 Amps & 5 lacs

operations in place of earlier

one with 1 Amp & 1 lac

operations.

3. Firm carried out modification in

3 units per loco shed and also

impart training to shed officials

for carrying out the modification

in the remaining units

Completed in all units.

Failures of this card has

reduced in last 3 years.

Further performance is

under watch .

8

Main control unit (MCU) AAL make

Page 9: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Reasons of cooling fan failure were mainly due to bearing failures,

loose fitment in Aluminum housing and burning of motor winding .

Action plan Status

1. Diameter of bearing increased and

housing changed to Mild steel and

capacity of fan increased from 500W

to 1.5 kW.

2. Design of Fan has been modified and

validated in field trials.

(Havells make)

3. RDSO also issued modification sheet

no RDSO/ 2016/EL/MS /0449 Rev

0 dated 30.03.2016 for the same

4. Cooling fan bearing of ZIEHL-

ABEGG is to be replaced in 18

months and full unit is to be

replaced after a service of 6 years.

No failures of modified

cooling fan has been

reported .

ELS/BZA modified cooling

fan as per RDSO

modification sheet in 60

SIVs. Performance

reported satisfactory.

Zonal railways to complete

the modification.

Performance of modified

cooling fan is under

watch.

9

Cooling Fan Failure (AAL make )

Page 10: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Cooling failure ( AAL)

10

Page 11: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Cable of AC choke was passing just beneath the ZCT leading to erratic operation

of ZCT due to variation in impedance value. Also, mechanical stresses developed

on the core of ZCT which leads to its failure.

There are two ZCTs for sensing internal and external earth faults.

Action plan Status

1

AAL has been advised to replace

ZCTs of M/s. DEESYS make of Korea

by M/s. Broycee Control of England.

Firm has replaced 100 units. Rly.

will replace remaining ZCTs of

DEESYS make by M/s. Broycee

Control make and till date Rly.

replaced 118 units. There is

reduction in failures of ZCT’s.

Further performance is under

watch.

11

Failure of ZCT AAL

Page 12: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

There have been frequent failures of Battery Charger and chopper CT.

All failures were of ABB make CTs. There was a loose connection in

power supply terminals due to wrong position of screw.

Action plan Status

1 Firm have sent failed DCCT/CHCT

to OEM (ABB) for investigation and

reported failures were due to

defective batch of 180 no.’s.

Total 130 no.’s replaced .

Failures have reduced and

further performance is under

watch. Firm advised to

replaced remaining with LEM

make CT.

12

Charger/ Chopper CT failures of AAL

Page 13: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

GDU card of Battery charger are failing due to decrease in winding

resistance& voltage range of Pulse transformer particularly after 5

years of service.

Action plan Status

1

2

3

Winding resistance and voltage

range of pulse transformer

measurement is to be done by

Sheds and to be replaced on

condition basis.

BZA shed carried out rewinding of

defective pulse transformer.

Performance reported by shed as

satisfactory of such transformers.

Old cards (> 09 years service of

KIT -3 ) to be replaced by modified

card.

Performance of replaced

pulse transformer is under

watch.

Modified cards in Kit –3

fitted in 30 locos ( CNB – 12

& KZJ- 18). Performance is

satisfactory.

13

GDU card failures of AAL

Page 14: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

SIV HIND RECTIFIER MAKE

PERFORMANCE OF M/s. HIND RECTIFIER SUPPLIED 180

KVA STATIC CONVERTER

14

Page 15: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY AT A GLANCE ( HIND)

Firm Population 2016-17

up to Dec

16

2015-16 2014-15

2013-14

2012-13

Hind

310 22.37 % 18.64% 35.79 % 18.7% 16.9%

15

Page 16: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY M/s. HIND YEAR WISE

16

109.9

58.0

80.0

44.0

26.7

16.9 18.7

35.8

18.6 22.4

0.0

20.0

40.0

60.0

80.0

100.0

120.0

2007-08 2008-09 2009-10 2010-11 2011-12 2012-13 2013-14 2014-15 2015-16 2016-17 (DEC)

Series1

Page 17: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Major Component-wise year wise failure analysis HIND

SN Year

Component

2012-13 2013-14 2014-15 2015-16 2016-17

1 QCON timer

card

07 01 07 06 09

2 Crow bar

thyristor

01 04 02 03 01

3 Cooling Fan 00 00 08 03 11

4 Snubber

Capacitor

01 01 04 03 06

5 Control card

A703 &

A704

01 03 (2+1) 04 ( 1+3) 06 ( 2+4) 05 ( 3+2)

6 Fuse 02 04 07 02 10

17

Page 18: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Initially wiring of delay timer was tapped from secondary of Auto

transformer at 380 ± 5% V but the voltage spikes were the cause of

melting the fuses failures.

Action plan Status

1

2

The firm proposed to change the

secondary tap point taken from

380 ± 5% V to 110 ± 5% since at

low voltage spikes will be less

Use of 110 V timer

Firm has modified 20 units

and after satisfactory

performance , firm has been

permitted to modify all the

units.

Fitment feed back along with

performance is under watch .

18

QCON TIMER CARD OF M/s HIND

Page 19: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

The problem was unwanted firing pulse to crow bar thyristor for

protection of DC link over voltage.

Action plan Status

1 To prevent unwanted firing of crow

bar thyristor an energy absorption

unit is being introduce by firm.

Firm has introduced in 06

locos an energy absorption

unit (04 no ET, 01 CNB

01 JHS). which reduces the

excess energy generated due

to unwanted firing of crow bar

thyristor and thereby

preventing the melting of

fuse.

Another 50 units has been

permitted & to be done

within 02 (two) months.

Fitment feed back along with

performance is under watch.

19

CROW BAR THYRISTOR OF M/s HIND

Page 20: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

The capacitance value (0.47 mF) of Snubber capacitors are deteriorating

after a service period of 3 to 4 years of service. The value is deteriorating

from 0.47 micro farad to 0.5 nano farad. The capacitors are Oil filled

and not dry type and the life of oil filled type capacitor is less than Dry

type.

Action plan Status

1 Firm has been asked to make a

cycle check on the value of

snubber capacitors and if the value

deteriorates they have to replace

with new Capacitors of Dry Type.

One cycle checking done.

Firm has replaced snubber

capacitors in 26 locos with

dry type. Total 247 unit have

been checked. Sheds have

also been requested to check

the value of capacitors during

maintenance and replace if

required. This has been

communicated to all railways.

20

Snubber Capacitor problem of M/s HIND

Page 21: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

The basic problem is bearing failure. All the bearing failures are after a

service period of 4 years.

Action plan Status

1 Zonal railways are advised to

replace bearing after a service

period of 04 years. .

Zonal railways have to replace

the bearing .

21

Cooling Fan failures of M/s HIND

Page 22: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

There are failures of Control Cards A 704 (Chopper) & A 703 (Inverter) .

VD-9 diode failed and Programmable logic device damaged.

Action plan Status

1 The failed control cards were sent

to M/s. Transtanik/ Germany for

investigation by firm. It was

reported by the firm that diode

(VD-9) and PLD (Programmable

logic device) of SCR board

damaged and these were replaced

by the firm.

The performance of control card

failures is under watch.

Detailed action plan awaited

22

Control card failures of M/s HIND

Page 23: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

25 Amps rating fuse in Battery charger out put failed make EATON and

FERRAZ.

Action plan Status

1 The 25 Amps rating fuse in

Battery charger out put failed.

Replacement of fuse by 35 Amps.

The fuse of M/s EATON and

FERRAZ are replaced by 35

amps. All fuse replaced. The

performance is under watch.

23

Fuse failures in Battery Charger out put

Page 24: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

SIV SIEMENS MAKE

PERFORMANCE OF M/s. SIEMENS SUPPLIED 180 KVA

STATIC CONVERTER

24

Page 25: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY AT A GLANCE (SIEMENS)

Firm Populatio

n

2016-17

upto DEC

16

2015-16 2014-15

2013-14

2012-13

Siemens

905 4.27% 5.36 % 9.0 % 10.9% 10.3 %

25

Page 26: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY M/s. SIEMENS YEARWISE

26

37.4

28.1

19.8

17.5

14.5

10.3 10.9

9.0

5.4 4.3

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

2007-08 2008-09 2009-10 2010-11 2011-12 2012-13 2013-14 2014-15 2015-16 2016-17 (DEC)

Series1

Page 27: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Major Component-wise year wise failure analysis SIEMENS

SN Year

Component

2012-13 2013-14 2014-15 2015-16 2016-17

1 Battery

Charger

9 21 22 3 4

2 Cooling Fan 15 19 18 10 10

3 Inverter 16 20 05 6 6

27

Page 28: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Indigenized Battery charger failed due to failure of rectifier module due

to Diode getting open circuit.

Action plan Status

1 Firm has to modify rectifier section

in their Indigenized Battery

charger.

Amongst 286 units 260 units

has been modified by the

firm.

Firm has been advised to

modify balance 26 units

within 30.06.2017.

28

Failure of Battery charger

Page 29: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

The cooling fan of M/s Siemens failed due to bearing failures and Jam.

Firm stated the major failure of cooling fan bearing is due to either

improper mounting of cooling fan or improper maintenance

Action plan Status

1

2

As per firm’s advice the

bearing of cooling fan is to be

replaced after a service period

4.5 years.

RDSO has issued guideline

vide RDSO letter no

EL/1.2.9.1 dated 29.04.2016

Zonal railways to replace bearing

as per OEM recommendation.

The performance in Zonal railways

is under watch

29

Cooling fan failure M/s. Siemens

Page 30: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

The failures of inverter module are repetitive due to various reasons like

component failures, IGBT failure etc. During previous meeting firm has

been advised to draw action plan of Inverter failure.

Action plan Status

1 There are two cases of warranty

failures of Inverter . Loco no 28726

and loco no 27263 of ELS/AQ and

ELS/BSL respectively

Firm stated the causes of

failures along with action

plan is to be submitted to

RDSO.

Firm also stated that no clear

trend has been noticed for

the failures.

30

Inverter failures of Siemens

Page 31: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

SIV MEDHA MAKE

PERFORMANCE OF M/s. MEDHA SERVO DRIVE

SUPPLIED 180 KVA STATIC CONVERTER

31

Page 32: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY AT A GLANCE (MEDHA)

Firm Population 2016-17

upto Dec

2015-16 2014-15

2013-14

2012-13

MEDHA

337 16.62% 11.19% 9.44 % 12.5% 9.7%

32

Page 33: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY M/s. MEDHA YEARWISE

33

137.5

80.9

67.0

32.9

27.0

9.7 12.5

9.4 11.2

16.6

0.0

20.0

40.0

60.0

80.0

100.0

120.0

140.0

160.0

2007-08 2008-09 2009-10 2010-11 2011-12 2012-13 2013-14 2014-15 2015-16 2016-17 (DEC)

Series1

Series2

Page 34: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Major Component-wise year wise failure analysis MEDHA

SN Year

Component

2013-14 2014-15 2015-16 2016-17

1 Main

control card

07 01 01 05

2 TDC-IF 01 17 05 07

3 Battery

Charger

03 01 02 04

34

Page 35: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

The tripping of SIV occurred due to sensing over voltage of OHE though

OHE voltage was below specified limit.

Action plan Status

1. The case has been studied by the

firm and found that heat generated

in TDC-IF card which leads to

opening of solder joint of a resistor

in RC circuit. The firm has now

provided RC network in place of

resistor.

2. On further study the limit of OHE

sensor of SIV is being increased

from 500 ms to 1 sec. by software

modification vide letter dated

5.4.2017

3. Average time increased from 200ms

to 500ms

1. Problem occurred again in

the locos where modification in

RC network of TDC-IF card was

carried out. .

2. Software modification in 20

locos in ELS/CNB and KZJ.

The performance is satisfactory.

Firm has been advised to

implement the modification in

all units.

35

TDC-IF & MCU card failure of M/s Medha SIV

Page 36: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

The fuse failure took place due to cable contact loose (voltage feed

back circuit).

Action plan Status

1. Firm advised to ensure proper

quality of crimping / soldering

of the contact.

2. Checking the contacts in

schedule maintenance as

specified in SMI.

(i) Two cases failed after a

service period of 05 years.

(ii) Two cases failed after a

service period of 08 years.

36

Battery charger fuse failure of M/s Medha SIV

Page 37: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

SIV ABB MAKE

PERFORMANCE OF M/s. ABB SUPPLIED 180 KVA STATIC

CONVERTER

37

Page 38: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY AT A GLANCE (ABB)

Firm Population 2016-17

upto Dec

16

2015-16 2014-15

2013-14

2012-13

ABB

116 22.22% 13.16 % 35.06 % 22.2% 26.5%

38

Page 39: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

FRPCPY M/s. ABB YEARWISE

39

350.0

700.0

70.0 50.4 43.0

26.5 22.2 35.1

13.2 22.2 0

100

200

300

400

500

600

700

800

ABB 2007-08 2008-09 2009-10 2010-11 2011-12 2012-13 2013-14 2014-15 2015-16 2016-17 (DEC)

Chart Title

FRPCPY

FRPCPY

Page 40: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Major Component-wise year wise failure analysis ABB

SN Year

Component

2015-16 2016-17

1 PEC card 01 05

2 Cooling Fan 02 06

40

Page 41: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Cooling fan getting jammed after a service period of 4 to 5 years

Action plan Status

1

The cooling fan bearing is to be

replaced after a service period of 04

years.

Zonal Railways advised

accordingly .

41

Cooling fan failures M/s ABB SIV

Page 42: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Problem was due to loose connection between male & female connectors

of PEC due to which fuse of input/output also melting.

Action plan Status

1

The power supply card connection

with junction box was not proper

which causes these failures.

PEC card assembly replaced

No failures reported till then.

42

PEC card failures M/s ABB SIV

Page 43: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Maintenance practices adopted by ELS/ BZA & ED

ELS/ ED & ELS/ BZA have developed Electronic Lab for

testing of various Electronics cards of 180 KVA Static

Converter.

43

Page 44: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Maintenance practices adopted by ELS/ BZA & ED

ELS/ ED has repaired 83 Nos. of cards till date .

ELS/ BZA investigated the failures of GDU card and found

that GDU card was failing due to failure of Pulse

transformer. Shed has developed an In-house test bench

and re-wind the Pulse transformer. They achieved the

same voltage range of pulse of +16 V to -11 V and winding

resistance of 0.2 to 0.3 Ω.

44

Till now shed has provided 12 no.’s

of such re-winded Pulse

transformers and all are working

satisfactorily. In this way they have

saved purchase of complete GDU

card which costs 2.2 lakhs.

Page 45: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

Status of AMC of SIV

Firm Status

AAL • Firm has given two types of budgetary quotations. ( SIV older than 06 years & SIV less than 06 years). No Railways has floated any tender.

Hirect • Firm has given budgetary quotations. • Tender has been invited for 06 units by ELS/BSL/CR which is under TC.

Siemens • Firm has given budgetary quotations. • Tender has been invited for 41 units by ELS/BSL/CR, 29 units by

ELS/HWH/ER & 09 units ELS/ASN/ER

Medha • Firm has given budgetary quotations. • LOA awarded for 06 units by ELS/ASN/ER on 21.04.2017. • LOA awarded for 02 units by ELS/BRC/WR on 27.04.2017. • Tender has been invited for 04 units by ELS/HWH/ER opened on

24.04.17 & 07 units by ELS/AJJ/SR which is under TC. Opened on 08.03.17.

• Tender will be opened for 60 units by SCRly on 19.05.2017.

ABB • Firm has given budgetary quotations. 45

Page 46: Performance Review Static converter (SIV) · Sudden voltage changes across QCON relay contact which leads to stucking up of QCON relay contact, hence MCU failure. Action plan Status

THANKS