Motor: 3600 rpm. synchr. Tolerance: ±5% Impeller, Max. dia.: 5.43” (132 mm) Impeller, Min. dia.: 3.54” (90 mm) Pump inlet, Dia.: 2” (51 mm), DN 50 Pump outlet, Dia.: 1½” (38 mm), DN 40 Performance data refer to water at 68 o F (20 o C). Performance Curves LKH-5 Centrifugal Pumps - 60 Hz NOTE! The curves refer to max. motor: 3.4 Hp (2.5 kW), 3460 rpm. asynchr., 60 Hz. For smaller motors, reduce head (H) with: 3%. DO NOT FORGET THE SAFETY FACTOR.

Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3600 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 5.43” (132 mm)Impeller, Min. dia.: 3.54” (90 mm)Pump inlet, Dia.: 2” (51 mm), DN 50Pump outlet, Dia.: 1½” (38 mm), DN 40

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-5 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to max. motor: 3.4 Hp (2.5 kW), 3460 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 3%.

DO NOT FORGET THE SAFETY FACTOR.

daniele
CORRECT OMD LOGO
Page 2: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 5.43” (132 mm)Impeller, Min. dia.: 3.54” (90 mm)Pump inlet, Dia.: 2” (51 mm), DN 50Pump outlet, Dia.: 1½” (38 mm), DN 40

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-5 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to max. motor: 1.7 Hp (1.3 kW), 1700 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 3%.

DO NOT FORGET THE SAFETY FACTOR.

Page 3: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 6.417” (163 mm)Impeller, Min. dia.: 4.331” (110 mm)Pump inlet, Dia.: 2.5” (63.5 mm), DN 65Pump outlet, Dia.: 2” (51 mm), DN 50

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-10 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 11.5 Hp (8.6 kW), 3500 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 3%.DO NOT FORGET THE SAFETY FACTOR.

Page 4: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-10 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 6.417” (163 mm)Impeller, Min. dia.: 5.512” (140 mm)Pump inlet, Dia.: 2.5” (63.5 mm), DN 65Pump outlet, Dia.: 2” (51 mm), DN 50

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 1.8 kW, 1750 rpm.asynchr., 60 Hz.DO NOT FORGET THE SAFETY FACTOR.

Page 5: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 5.433” (138 mm)Min. dia.: 4.724” (120 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-15 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 11.5 Hp (8.6 kW), 3455 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 3%.DO NOT FORGET THE SAFETY FACTOR.

Page 6: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-15 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 5.433” (138 mm)Impeller, Min. dia.: 4.724” (120 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 2.4 Hp (1.75 kW), 1710rpm. asynchr., 60 Hz.DO NOT FORGET THE SAFETY FACTOR.

Page 7: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 6.496” (165 mm)Impeller, Min. dia.: 4.724” (120 mm)Pump inlet, Dia.: 2.5” (63.5 mm, DN 65)Pump outlet, Dia.: 2” (51 mm, DN 50)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-20 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 16.8 Hp (12.5 kW), 3500 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 3%.DO NOT FORGET THE SAFETY FACTOR.

Page 8: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-20 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 6.496 (165 mm)Impeller, Min. dia.: 5.512” (140 mm)Pump inlet, Dia.: 2.5” (63.5 mm, DN 65)Pump outlet, Dia.: 2” (51 mm, DN 50)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 2.4 Hp (1.75 kW), 1750rpm. asynchr., 60 Hz.DO NOT FORGET THE SAFETY FACTOR.

Page 9: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 8.070” (205 mm)Impeller, Min. dia.: 6.299” (160 mm)Pump inlet, Dia.: 3” (76 mm, DN 80)Pump outlet, Dia.: 2.5” (63.5 mm, DN 65)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-25 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 33.5 Hp (25 kW), 3545 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with:- 3% for 16.8-28.2 Hp (12.5-21 kW).- 5% for 8.5-11.5 Hp (6.3-8.6 kW).DO NOT FORGET THE SAFETY FACTOR.

Page 10: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-25 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.:: 8.070” (205 mm)Impeller, Min. dia.: 6,299” (160 mm)Pump inlet, Dia.: 3” (76 mm, DN 80)Pump outlet, Dia.: 2.5” (63.5 mm, DN 65)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 4.7 Hp (3.5 kW), 1720rpm. asynchr., 60 Hz.DO NOT FORGET THE SAFETY FACTOR.

Page 11: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 8.661” (220 mm)Impeller, Min. dia.: 6.693” (170 mm)Pump inlet, Dia.: 2.5” (63.5 mm, DN 65)Pump outlet, Dia.: 2” (51 mm, DN 50)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-35 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 28.2 Hp (21 kW), 3535 rpm.asynchr., 50 Hz.For smaller motors, reduce head (H) with:- 3% for 16.8-22.8 Hp (12.5-17 kW).- 5% for 8.5-11.5 Hp (6.3-8.6 kW).DO NOT FORGET THE SAFETY FACTOR.

Page 12: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-35 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 8.661” (220 mm)Impeller, Min. dia.: 6.693” (170 mm)Pump inlet, Dia.: 2.5” (63.5 mm, DN 65)Pump outlet, Dia.: 2” (51 mm, DN 50)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 3.4 Hp (2.5 kW), 1720 rpm.asynchr., 60 Hz.DO NOT FORGET THE SAFETY FACTOR.

Page 13: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 9.252” (235 mm)Impeller, Min. dia.: 6.693” (170 mm)Pump inlet, Dia.: 3” (76 mm, DN 80)Pump outlet, Dia.: 2” (51 mm, DN 50)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-40 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 33.5 Hp (25 kW), 3500 rpm.asynchr.,60 Hz.For smaller motors, reduce head (H) with:- 3% for 16.8-28.2 Hp (12.5-21 kW).- 5% for 11.5 Hp (8.6 kW).DO NOT FORGET THE SAFETY FACTOR.

Page 14: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-40 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 9.252” (235 mm)Impeller, Min. dia.: 7.480” (190 mm)Pump inlet, Dia.: 3” (76 mm, DN 80)Pump outlet, Dia.: 2” (51 mm, DN 50)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 8.5 Hp (6.3 kW), 1750 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 5%.DO NOT FORGET THE SAFETY FACTOR.

Page 15: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 7.008” (178 mm)Impeller, Min. dia.: 5.512” (140 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-45 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 33.5Hp (25 kW), 3545 rpm.asynchr.,60 Hz.For smaller motors, reduce head (H) with:- 3% for 16.8-28.2 Hp (12.5-21 kW).- 5% for 8.5-11.5Hp (6.3-8.6 kW).DO NOT FORGET THE SAFETY FACTOR.

Page 16: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-45 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 7.008” (178 mm)Impeller, Min. dia.: 5.512” (140 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 4.7 Hp (3.5 kW), 1720 rpm.asynchr., 60 Hz.DO NOT FORGET THE SAFETY FACTOR.

Page 17: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 8.070” (205 mm)Impeller, Min. dia.: 5.906” (150 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-50 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 33.5 Hp 2(5 kW), 3500 rpm.asynchr.,60 Hz.For smaller motors, reduce head (H) with:- 3% for 16.8-28.2 Hp (12.5-21 kW).- 5% for 8.5-11.5 Hp (6.3-8.6 kW).DO NOT FORGET THE SAFETY FACTOR.

Page 18: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-50 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%.Impeller, Max. dia.: 8.070” (205 mm)Impeller, Min. dia.: 5.906” (150 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 6.0 Hp (4.5 kW), 1750 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 5%.DO NOT FORGET THE SAFETY FACTOR.

Page 19: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 8.268” (210 mm)Impeller, Min. dia.: 6.299” (160 mm)Pump inlet, Dia.: - 4” (101.6 mm, DN 100)

- 6” (DN 150)Pump outlet, Dia.: - 4” (101.6 mm, DN 100)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-60 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to motor: 46.9 Hp (35 kW), 3500 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with:- 3% for 16.8-28.2 Hp (12.5-21 kW).- 5% for 8.5-11.5 Hp (6.3-8.6 kW).DO NOT FORGET THE SAFETY FACTOR.

Page 20: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-60 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 8.268” (210 mm)Impeller, Min. dia.: 6.299” (160 mm)Pump inlet, Dia.: - 4” (101.6 mm, DN 100)

- 6” (DN 150)Pump outlet, Dia.: - 4” (101.6 mm, DN 100)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to motor: 8.5 Hp (6.3 kW), 1750 rpm.asynchr., 60 Hz.For smaller motors, reduce head (H) with: 5%.DO NOT FORGET THE SAFETY FACTOR.

Page 21: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Motor: 3500 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 11.024” (280 mm)Impeller, Min. dia.: 7.874” (200 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

Performance CurvesLKH-70 Centrifugal Pumps - 60 Hz

NOTE! The curves refer to max. motor: 115.3 Hp (86 kW), 3565rpm. asynchr., 60 Hz.For smaller motors, reduce head (H) with: - 3%DO NOT FORGET THE SAFETY FACTOR.

Page 22: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-70 Centrifugal Pumps - 60 Hz

Motor: 1750 rpm. synchr.Tolerance: ±5%Impeller, Max. dia.: 11.024” (280 mm)Impeller, Min. dia.: 7.874” (200 mm)Pump inlet, Dia.: 4” (101.6 mm, DN 100)Pump outlet, Dia.: 3” (76 mm, DN 80)

Performance data refer to water at 68oF (20oC).

NOTE! The curves refer to max. motor: 22.8 Hp (17 kW),1750 rpm. asynchr., 60 Hz.DO NOT FORGET THE SAFETY FACTOR.

Page 23: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-110 Multi-Stage Centrifugal Pumps - 60 Hz

Motor: 3600 rpm. synchr.Tolerance: ±5%.Impeller: 6.42” (163 mm).Pump inlet, Dia.: 2” (51 mm), DN 50.Pump outlet, Dia.: 1.5” (38 mm), DN 40.

Performance data refer to water at 68oF (20oC).NOTE! The curves refer to max. motor:LKH-112, 16.8 Hp (12.5kW) 3515 rpm. asynchr, 60 Hz.LKH-113, 22.8 Hp (17kW) 3505 rpm. asynchr, 60 Hz.LKH-114, 28.2 Hp (21kW) 3510 rpm. asynchr, 60 Hz.For smaller motors, reduce head (H) by: 3%DO NOT FORGET THE SAFETY FACTOR.

Page 24: Performance Curves - OMDeanomdean.com/wp...Laval_LKH_Pump-Performance-Curves.pdfPerformance data refer to water at 68 oF (20 C). Performance Curves LKH-15 Centrifugal Pumps - 60 Hz

Performance CurvesLKH-120/P Multi-Stage Centrifugal Pumps - 60 Hz VM66346US1 2004-04

Motor: 3600 rpm. synchr.Tolerance: ±5%Impeller: 8.11” (206 mm)Pump inlet, Dia.: 3”, DN 80Pump outlet, Dia.: 2½”, DN 65

Performance data refer to water at 68oF (20oC).NOTE! The curves refer to max. motor:100 Hp, 3565 rpm. asynchr., 60 HzFor smaller motors, reduce head (H) by 3%For inlet pressure > 10 bar, reduce head (H) by 5%

DO NOT FORGET THE SAFETY FACTOR.