17
MOULDED CASE CIRCUIT BREAKER C People Electric Appliance serves for people. ISO14001 OHSAS18001 ISO9001

People MCCB

  • Upload
    pauline

  • View
    346

  • Download
    11

Embed Size (px)

DESCRIPTION

People Brand

Citation preview

  • MOULDED CASECIRCUIT BREAKER

    C

    People Electric Appliance serves for people.

    ISO14001 OHSAS18001ISO9001

  • RDM1 MOULDED CASE CIRCUIT BREAKER

    APPLICATION

    RDM1 series of moulded case circuit breaker is a new type product developed and manufacturedby adopting international advanced technology. It is supplied with rated insu lation voltage 800V and used for circuit of AC50Hz, rated operating voltage AC 400V or below rated operation currentup to 800A for infrequent changing over and starting of the motors. Equipped w ith t he protectiondevices for over-current, short circuit and undervoltage, the product is capable of preventingdamage of circuits and supplying units The product conforms to IEC60947-2.

    SPECIFICATION

    TypeRated

    current(A)

    Num-ber ofPoles

    Ratedinsula-

    tionvoltage

    (V)

    Ratedoperat-

    ingvoltage

    (V)

    Arcing-over

    distance(mm)

    Ultimateshort

    circuitbreakingcapacity

    (KA)

    Serviceshort

    circuitbreakingcapacity

    (KA)

    Operationperfor-mance

    ON OFF

    RDM1-63LRDM1-63MRDM1-100CRDM1-100LRDM1-100MRDM1-100HRDM1-225CRDM1-225LRDM1-225MRDM1-225HRDM1-400CRDM1-400LRDM1-400MRDM1-630CRDM1-630LRDM1-630MRDM1-630HRDM1-800MRDM1-800H

    6,10,16,20,25,32,40,

    50,63

    10,16,20,25,32,40,50,63,80,

    100

    100,125160,180

    200,

    225,250315,350

    400

    400500630

    630,700800

    3P,4P 660V 380V

    000

    0( 50)0( 50)0( 50)

    50505050505050

    100100100100100100

    25502535508525355085355065355065

    10065

    100

    18351822355018223550253542253542654265

    1500 8500

    1000 7000

    1000 4000

    RDM1-63L 3P

    RDM1-225L 3P

    RDM1-400 3P

    ACCESSORIES FOR MCCB

    Alarm contact Under voltage release

    Manual operation Auxiliary contact Shunt release

    MOULDED CASE CIRCUIT BREAKER

    A C-01

  • APPLICATION

    RDM11 MOULDED CASE CIRCUIT BREAKER

    RDM11 moulded case circuit breake r is one o f the most advanced type breakers i n the world, which adopts international advanced design and manufacture technology. They are suitable for shortcircuit and overload protection for circuit of AC 690V 50/60Hz, rated current from 12.5A to 630A.It takes protective effect when mouse cage motors non-fre quent star t, breakin g off working and protecting overload, short circuit and lacking voltage.

    TRIPPING CHARACTERISTICS OF MCCB

    Rated current of

    release(A)

    In 63

    63 In 100

    100 In 630

    Thermodynamic release (ambient temp+40 )

    1.05In(cold state)operative time (h)

    1.30In(heat state)operative time (h)

    1

    2

    2

    1

    2

    2

    Operational currentof magneticrelease(A)

    10In 20%

    10In 20%

    5-10In 20%

    Rated current of

    release(A)

    12.5 In 400

    Thermodynamic release (ambient temp+40 )

    2

    1.0In(cold state)operativetime (h)

    1.20In(heat state)operativetime (h)

    1.50In(heat state)operativetime (h)

    2 4min

    7.20In(coldstate)

    operativetime (h)

    2S Tp 10S

    Operational currentof magneticrelease(A)

    12In 20%

    SPECIFICATION

    RDM11-100N 3P

    RDM11-250N 4P

    RDM11-630N 3P

    Ratedcurrent

    (A)Type Poles

    Ratedinsulatingvoltage

    (V)

    Ratedoperatingvoltage

    (V)

    Arcingover

    distance(mm)

    Serviesshort

    circuitbreakercapacity

    Ultimateshort

    circuitbreakercapacit

    Operatingperfor-mance(times)

    RDM11-100DRDM11-100NRDM11-100HRDM11-100LRDM11-160DRDM11-160NRDM11-160HRDM11-160LRDM11-250DRDM11-250NRDM11-250HRDM11-250LRDM11-400DRDM11-400NRDM11-400HRDM11-400LRDM11-630DRDM11-630NRDM11-630HRDM11-630LRDM11-1250DRDM11-1250NRDM11-1250HRDM11-1250LRDM11-1600DRDM11-1600NRDM11-1600HRDM11-1600L

    12.5,16,20,25,32,40,50,63,

    80,100

    16,20,25,32,40,50,

    63,80,100,125,160

    160,180,200,225,

    250

    200,225,250,300,315,400

    315,350,400,500,600,630

    3,4 950 690 0

    182570150253670150253670150354570150354570150506585160506585160

    182570150253670150253670150354570150354570150506585160506585160

    1500 8500

    1500 7000

    1000 7000

    1000 4000

    1000 4000

    630,700800,1000,

    1250

    800,1000,1250,1600

    500,2500

    500,2500

    MOULDED CASE CIRCUIT BREAKER

    RDM11-250N

    RDM11-100N

    A C-02

  • PNE-100 2P

    PNE-100 3P

    PNE-250 3P

    Type

    Number of Poles

    Rated Current In(A)

    Rated Operating Voltage Ue(V) AC50/60Hz

    Rated Insulation Voltage Ui(V)

    Rated (kV)Uimp

    Breaking Capacity

    (kA ms)

    IEC60947-2

    Icu AC

    220/240V

    380V

    400

    220/240V

    380V

    400V

    240V

    480V

    Ics%Icu

    ACBreaking Capacity(kA)(NEMA-ABI)(HIC)

    Mechanical Life

    Electrical Life

    OverloadCurrentProtection(A)

    Hot protection

    Magnetism protection

    Dimensions(mm)

    L H D

    PNE 60E PNE 100F PNE 100H PNE 250

    3 3 3 3

    15,20,25,30,40,50,

    60

    15,20,25,30,40,50,60,75,80,

    100

    15,20,25,30,40,50,60,75,80,

    100

    125,160225,250

    500

    500

    6

    10

    7.5

    7.5

    25%

    25%

    25%

    -

    -

    8.500

    4.000

    Fixed

    Fixed

    500

    500

    6

    25

    10

    7.5

    25%

    25%

    25%

    -

    -

    8.500

    4.000

    Fixed

    Fixed

    500

    500

    6

    50

    30

    20

    25%

    25%

    25%

    25

    10

    8.500

    4.000

    Fixed

    Fixed

    500

    500

    6

    85

    18

    15

    50%

    50%

    50%

    25

    10

    8.500

    4.000

    Fixed

    Fixed

    75 13060

    75 13060

    75 13060

    105 16565

    PNE MOULDED CASE CIRCUIT BREAKER

    APPLICATION

    PNE moulded case circuit break er is one of the most advanced type breakers in the world, which ado pts international advanced design and manufactur technology. They aresuitable for short circuit and overload protection for circuit of AC 690V 50 / 60Hz, rated currentfrom 15A to 160A. Its rated insulation voltage is 690V. It can make and break the non-frequen t c ircui t in the normal cond itio ns. It takes protective effect when mouse cagemotors no n-fr equent st arting or breaking off working and protecting overload, shortcircuit and lacking voltage. It complies with IEC60947-2.

    MAIN TECHNICAL SPECIFICATION

    MOULDED CASE CIRCUIT BREAKER

    PNE-100

    PNE-250

    A C-03

  • Type

    RDM8(CW)-100

    Rated current (A)

    15,20,30,40,50,60,75,100,125

    Pole number

    3 pole

    Rated operating voltage (V)

    Rated operating voltage (V)

    PT-125

    PT-250

    RDM8 125-CW

    RDM8 250-CW

    PT MOULDED CASE CIRCUIT BREAKER

    APPLICATION

    PT Moulded case circuit breaker is suitable for circuit AC 50Hz/60Hz, rated voltage up toAC 660V,rated operating current to 630A. It features normal structure, reliable performance, complete accessories & high breaking capacity, used for power dis tribut ion and protecting t he circu it and electrical equipment against overload and short-circuit. It complies with standard of IEC947-2.

    TRIPPING CHARACTERISTICS OF MCCB

    Rated current of

    release (A)

    In 63

    63 In 250

    25 In 800

    Thermodynamic release(ambient temp+40 )

    1.05In (cold state)operative time (h)

    1.30In (heat state)operative time (h)

    Operational currentof magneticrelease(A)

    1

    2

    2

    1

    2

    2

    10-50In 20%

    10In 20%

    5-10In 20%

    RDM8-CW MOULDED CASE CIRCUIT BREAKER

    RDM8-CW moulded case circuit breaker is available in three ranges, standard, high-breaking capacity. The performance of the RDM8-CW MCCB range is the result of ex tens ive design& development utilising AAD accredited test station. The current limiting action fo RDM8-CWMCCB provi des low va lues of let-through energy. Full information for this and time/currentcharacteristic curves are both available on request to provide more information.

    MOULDED CASE CIRCUIT BREAKER

    660V 380V, 660VRDM8(CW)-250 125,150,175,200,225,250 3 pole 660V 380V, 660V

    TRIPPING CHARACTERISTICS OF MCCB

    Rated current of

    release (A)

    In 63

    63 In 250

    25 In 800

    Thermodynamic release(ambient temp+40 )

    1.05In (cold state)operative time (h)

    1.30In (heat state)operative time (h)

    Operational currentof magneticrelease(A)

    1

    2

    2

    1

    2

    2

    10-50In 20%

    10In 20%

    5-10In 20%

    RDM8 125-CW

    RDM8 125-CW

    A C-05

  • TypePole

    Number(P)

    Rated current(A)Rated

    current offrame(A)

    Rated ultimatebreaking capacity

    (KA)

    RDM8 30-CSRDM8 50-CSRDM8 60-CSRDM8 100-CSRDM8 250-CSRDM8 400-CSRDM8 630-CSRDM8 800-CSRDM8 1250-CS

    32,33

    2,333333

    3,5,10,15,20,3010,15,20,30,40,50

    6060,70,100

    125,150,175,200,225,250250,300,350,400

    500,600,630600,700,800

    800,1000,1200,1250

    305060

    100250400630800

    1250

    1.55/105/10

    18/2518/3525/50

    353585

    RDM8-CS MOULDED CASE CIRCUIT BREAKER

    APPLICATION

    RDM8-CS series Moulded Case Circuit Breaker is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume,etc. This breaker applies to the circuit with AC 50/60 Hz, r ated insulation voltage 660V, max.rated current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency.

    SPECIFICATION

    RDM8-SS MOULDED CASE CIRCUIT BREAKERAPPLICATION

    SPECIFICATION

    RDM8-SS series Moulded Case Circuit Breaker is a kind of economic breaker, has the features asfollowing, such as steady and reliable property, reasonable structure, beautiful style, small volume,etc. This breaker applies to the circuit with AC50/60Hz, rated insulation voltoge 660V, max .ratedcurrent 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion ofline and unfrequency.

    Type Polenumber

    Rated current(A)

    Breaking capacity(KA)

    AC(P1/P2)

    RDM8 30-SS

    RDM8 50-SSRDM8 60-SS

    RDM8 100-SS

    RDM8 250-SS

    RDM8 400-SS

    RDM8 630-SS

    RDM8 800-SS

    23333434343434

    3,5,10,15,20,30

    10,20,30,40,5010,20,30,40,50,60

    60,75,100

    125,150,175,200,225,255

    250,300,350,400

    500,600,630

    600,700,800

    240 380 415 500 600 660

    5/5 5/2.5 2.5/1.5 2.5/1.0

    5/105/10

    10/7.510/7.5

    7.5/57.5/5

    7.5/57.5/5

    2.5/1.52.5/1.5

    - -

    --

    50/42

    50/42

    85/60

    85/60

    85/60

    30/20

    30/22

    50/35

    50/35

    50/35

    7.5/8

    25/15

    25/20

    50/30

    50/30

    15/10

    18/15

    35/25

    35/25

    35/25

    10/5

    15/10

    25/18

    25/18

    25/18

    5/2.5

    5/2.5

    15/10

    15/10

    15/10

    RDM8 30-CS 3P

    RDM8 100-CS 3P

    RDM8 50-SS 3P

    RDM8 250-SS 3P

    MOULDED CASE CIRCUIT BREAKER

    RDM8 30-CS

    RDM8 100-CS

    RDM8 50-SS

    RDM8 250-SS

    A C-06

  • Type Pole Rated current(A)Breakingcapacity

    (KA)Rated voltage(V)

    RDM7 32

    RDM7 33

    RDM7 52

    RDM7 53

    RDM7 62

    RDM7 63

    RDM7 102

    RDM7 103

    RDM7 202

    RDM7 203

    RDM7 403

    2

    3

    2

    3

    2

    3

    2

    3

    2

    3

    3

    3,5,10,15,20,30

    3,5,10,15,20,30

    15,20,30,40,50

    15,20,30,40,50

    60

    60

    60,75,100

    60,75,100

    125,150,175,200,225

    125,150,175,200,225

    250,300,350,400

    1.5

    1.5

    2.5

    2.5

    2.5

    2.5

    7.5

    7.5

    10

    10

    18

    415

    415

    600

    600

    600

    600

    600

    600

    600

    600

    600

    Type Pole Rated current(A)Breakingcapacity

    (KA)Rated voltage(V)

    RDM7 32

    RDM7 33

    RDM7 52

    RDM7 53

    RDM7 62

    RDM7 63

    RDM7 103

    RDM7 202

    RDM7 203

    RDM7 403

    2

    3

    2

    3

    2

    3

    3

    2

    3

    3

    3,5,10,15,20,30

    3,5,10,15,20,30

    15,20,30,40,50

    15,20,30,40,50

    60

    60

    15,20,30,40,50,60,75,100

    125,150,175,200,225

    125,150,175,200,225

    250,300,350,400

    1.5

    1.5

    5

    5

    5

    5

    15

    18

    18

    22

    660

    660

    660

    660

    660

    660

    660

    660

    660

    660

    RDM7(EA\SA) MOULDED CASE CIRCUIT BREAKER

    APPLICATION

    The circuit breaker is suitable for industrial or commercial power and lighting circuit. Its ratedworking voltage is from 240V to 415V(AC 50Hz). It can be used to protect the ci rcuit that overload or short circuit may take place and also for protecting the circuit which is not frequent in makingbreak operation under normal conditions.

    SPECIFICATION

    RDM7 52B(SA52B)

    RDM7 33B(SA33B)

    RDM7 103B(EA103B)

    MOULDED CASE CIRCUIT BREAKER

    RDM7 103B

    RDM7 33B

    RDM7 52B

    A C-07

  • PABS-D MOULDED CASE CIRCUIT BREAKER

    APPLICATION

    PABS-D series moulded case circuit breaker is suitable for industrial or commercial power andlighting with AC 50/60Hz, rated working volt age up to AC600V/DC 250V, rate d cu rrent up to 1200A. It s a kind of economical breakers with the ch aract ers of s table an d r eli abl e f unctio n,beautiful appearance, small size and line and infrequent starting motor. It can also be a ttachedto ins tall the accessor ies which have protection function for avoiding loss-voltage, under-vo ltage.The prod uct can inst all conn ection line with front board and back board, it also can be equipped hand-operating appar atus or mo tor-op erating apparatus to control in a remote distance.

    SPECIFICATION

    Number of poles

    Max rated servicevoltage Ui (V)

    Dim

    ensionsandm

    ountingdetails aaa c

    MOULDED CASE CIRCUIT BREAKER

    PABS-103b

    PABS-103b

    PABS-203b

    PABS-203b

    PABS-403b

    PABS-403b

    A C-08

    10,15,20,30,40,50,60,75,100

    500V 600V

    440V 480V

    380V

    220V 240V

    3

    600

    250

    90

    155

    56

    82

    132

    30

    10

    14

    25

    50

    10

    14

    14

    25

    50

    20

    14

    -

    -

    -

    -

    -

    -

    -

    -

    Rated current in (A) 40 reference ambient temperature

    3

    600

    250

    105

    165

    56

    84

    126

    30

    10

    14

    25

    50

    10

    14

    25

    25

    50

    20

    14

    3

    600

    250

    140

    257

    95

    145

    215

    44

    22

    25

    35

    50

    22

    25

    35

    35

    50

    20

    14

    125,150,175,200,225

    250,300,350,400

    Dim

    ensionsandm

    ountingdetails

    GB14048-2 AC (No symmetry value/symmetry value)

    IEC60947-2 Icu AC

    DC

    Connection way

    Alarming switch (AL)Auxiliary switch (AUX)

    Voltage release mounting (SHT)

    Low voltage release mounting (UVT)Accessory lead wire terminal platform (LT)

    Outer operate handle

    Terminal isolation cover

    Automatic tripping device

    Trip button

    AC

    DC

    a

    b

    c

    ca

    bb

    aa

    500V

    440V

    415V

    380V

    240V

    250V

    125V

    Shoppingfitting

    Press terminal

    -

    - Thermal electro-magnetism type

    Have

    b bb

    ca

  • MCCB Description Standard rangeCurrent rating(A)

    Standard range

    16A20A32A40A50A63A80A

    100A125A160A200A

    1 poleList number

    3 polesList number

    PME161PME201PME321PME401PME501PME630PME801

    PME1001PME1251PME1604

    -

    PME163PME203PME323PME403PME503PME633PME803

    PME1003PME1253PME1603PME2003

    Impulse withstand V.Utilisation categoryAdjustment thermal

    Adjustment magneticTerminal capacity(Max)

    8KVA

    FixedFixed

    120mm2

    8KVA

    FixedFixed

    120mm2

    Breaking capacity IEC60947 2/BS EN60947-2(AC 50/60Hz)

    690V AC

    480V AC

    400V AC/440V AC

    380V AC

    220V AC/240V AC

    250V DC

    Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)

    --------

    2519--

    121220202525303040403719

    PME-125 3P

    PME-250 3P

    PME MOULDED CASE CIRCUIT BREAKER

    SPECIFICATION

    PME moulded case circuit breaker is highly specified. Positive contact indication is standard,with three positions ON OFF and centre TRIPPED preventing the MCCB contactsfrom being held closed in the event of over current.

    PME moulded case circuit breaker 3 & 1 pole units have a trip to test button provided a s st andard.All main contacts are of quality. Silve alloy construction for durability. Comply ing with IEC60947-2is covered by type test and marine approval certification.1. Moulded case circuit breakers 16 to 200A.2. Available in three ranges: standard, standard adjustable, Hi-break adjustable.3. Complies with IEC60947-2.4. Current limiting action provides low values of lot-through energy.

    PME STANDARD RANGE

    MOULDED CASE CIRCUIT BREAKER

    A C-09

  • PAA MOULDED CASE CIRCUIT BREAKER

    DESCRIPTION

    PAA MCCB is Available in two frame sizes from 25 to 800 A. Loadline series of mouldedcase circuit breakers provide overload and short-circuit protection for the full range o f transf-orme r sizes encountered in normal service. The over load and i nstantaneo us trippin g elements,adjustable over a wide band, make these MCCBs ideal for many distribution applications. PAA MCCBs are available in single pole, three poles, three pol es with sw itched neu tral and switch-disconnector versions. Loadline triple poles PAA Frame circuit breaker and switch-disconnectorare physically interchangeable with PAA breakers for Motor Duty requirments. PAA Frame have front adjustable overload and fixed instantaneous tripping elements.

    SPECIFICATION

    TRIPPING ELEMENT

    Insulation voltage(Ui)-660V acOperating voltage(Ue)-415 acRated frequency-~50/60HzReference Calibration-40 (50 on request)

    Overload front adjustable 0.7-1.0 times rated currentInstantaneous-non-adjustable

    PAA 25-63A=400A PAA 80-125A=800A PAA 160-250A=1600A

    Description

    25

    32

    40

    50

    63

    80

    100

    125

    160

    200

    225

    250

    315

    400

    500

    630

    800

    In/A Lowest Setting Current amps

    17.5

    22.5

    28

    35

    44

    56

    70

    88

    112

    140

    157.5

    175

    221

    280

    350

    441

    560

    PAA-100

    single pole MCCB

    triple poles MCCB

    PAA-250

    PAA Frame

    PAA-400

    PAA-630

    PAA-800

    PAA 100 1P

    PAA 250 3P

    PAA 400 3P

    MOULDED CASE CIRCUIT BREAKER

    A C-10

  • PDPX-125N 3P

    PDPX-250N 3P

    PDPX MOULDED CASE CIRCUIT BREAKER

    Pole numberRated current In(A)

    Type

    The electrical characteristic satisfiesEn60947 - 2Rated working voltageUe(50-60Hz)

    Rated working voltage Ue=(V)Rated insulation voltage Ui~(V)Rated impulse voltage Uimp(KV)Usage groupMoulded case switch typeLimited breaking capacity(KA) 230/240V~

    400/415V~440V~480/500V~600V~690V~250V

    Used breaking capacity lcos(%Icu)Short-circuit closed capacity(400V~)Short-time withstand current Icw(KA)Life (open,close for a time) mechanical

    ElectricalInsulation capacity

    Protection groupHot-magnetic tripElectronic tripTake to connect the ground to breakDown to probe into the function s theHigh choice electronic-tripResidual currentprotected modules installation

    Bottom

    On the sideinstallation

    Outer accessoriesControl from a distanceFix typeInsert typeDrawer typeScrew hand handlePower conversion systemDimension and weightDimension (L W H) (mm)

    Weight(kg)

    3 pole4 pole3 pole4 pole

    PDPX 125 PDPX 250

    PDPX-E PDPX PDPX PDPX PDPXPDPX-E3-4

    16-1253-4

    25-250

    500

    250500

    6A

    690

    250690

    8A

    E2216108--

    1610032

    35251812--

    2550

    52.5

    50362014--

    3050

    75.6

    60363025201636

    10075.6

    L170100704025204050

    220

    H10070604025204075

    154

    7000

    1000

    7000

    1000

    75.6 120 74101 120 74

    11.2

    105 200 105140 200 105

    2.53.7

    MOULDED CASE CIRCUIT BREAKER

    A C-11

    DESCRIPTION

  • PVL-160X 3P

    PVL-250X 3P

    PVL MOULDED CASE CIRCUIT BREAKER

    DESCRIPTION

    TypeRated

    currentIn(A)

    Setting current ofinverse-time

    delayed overloadrelease L I (A)R

    Operating current ofinstantaneous short-circuit release I Ii

    (A)

    Standard switchingcapacity N 40/45/50kA

    at 380/415V AC

    PVL 160X

    PVL250

    20

    32

    40

    50

    63

    80

    100

    125

    160

    200

    255

    16-20

    25-32

    32-40

    40-50

    50-63

    63-80

    80-100

    100-125

    125-160

    160-200

    200-250

    300

    300

    600

    600

    600

    1000

    1000

    1000

    1600

    1000-2000

    200-2500

    PVL1702-1DD33-...

    PVL1703-1DD33-...

    PVL1704-1DD33-...

    PVL1705-1DD33-...

    PVL1706-1DD33-...

    PVL1708-1DD33-...

    PVL1710-1DD36-...

    PVL1712-1DD36-...

    PVL1716-1DD36-...

    PVL3720-1DD36-...

    PVL3725-1DD36-...

    Type

    PVL 160X

    High switching capacity H 70 kA

    at 380/415V AC

    Very high switching capacity L

    100kA at 380/415V AC

    PVL 250

    PVL1702-2DD36-...

    PVL1703-2DD36-...

    PVL1704-2DD36-...

    PVL1705-2DD36-...

    PVL1706-2DD33-...

    PVL1708-2DD36-...

    PVL1710-2DD36-...

    PVL1712-2DD36-...

    PVL1716-2DD36-...

    PVL3720-2DD36-...

    PVL3725-2DD36-...

    PVL3720-3DC36-...

    PVL3725-3DC36-...

    XXX

    X

    Z

    Y Y

    PVL 160 circuit-breaker

    419

    2411

    106.590.58781.5

    120.5 63.5

    5831

    .5

    4-(250)d2.5-(160)

    88.5

    15.5 Y Y

    35 35 35

    PVL 160 and PVL 250circuit-breakers mounting detailPVL 250 circuit-breaker

    17.56 5.2

    75.5

    140 174.5

    115.5 Y

    88.5

    1224.5

    104.5139.5

    52.5

    1632

    1632

    NSK

    -884

    0

    NSK

    -884

    1

    8

    35 35 35 17.56 8.417.5

    35(3P)

    7 13 5.5

    75.5

    174.5

    185.514

    913

    11.5

    24.5104.5

    139.552.5

    18(8) 70(4P)

    19.5

    6513

    1.5

    2 5.2(3P)4 5.2(4P)

    MOULDED CASE CIRCUIT BREAKER

    A C-12

  • A C-13

    105 86

    152

    100

    DESCRIPTION

    PHFD MOULDED CASE CIRCUIT BREAKER

    PHFD moulded case circuit breakers are the choice of designer for coordinate protection of all types of low voltage power distribution systems.

    Description

    Single pole MCCB

    Triple poles MCCB

    In/ARated isolating

    voltage(V)

    Rated capacity

    (KA)

    15

    20

    25

    30

    35

    40

    50

    70

    90

    100

    125

    150

    15

    20

    25

    30

    35

    40

    50

    70

    90

    100

    125

    150

    175

    200

    225

    250

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    65

    PHFD-250N 3P

    PHFD-125N 3P

    MOULDED CASE CIRCUIT BREAKER

  • A C-14

    SPECIFICATION

    PHB MOULDED CASE CIRCUIT BREAKER

    Manufacture stardand:IEC60947-2Fixing type thermal tripFixing type magnetic trip

    MAX. RATED SHORT-CIRCUIT BREAKING CAPACITY

    PHB126HPHB226HPHB226NPHB226E

    Hull

    65kA35kA40kA

    100kA

    220/240VAC

    25kA25kA40kA70kA

    380/415VAC 660/690VAC

    --

    12kA14kA

    250VDC*

    10kA-

    10kA20kA

    Description Rated current(A)

    MCCBMCCBMCCBMCCBMCCBMCCBMCCBMCCBMCCB

    PHB226H-25kAMCCBMCCBMCCBMCCBMCCBMCCBMCCB

    PHB126H-25kA1620253240506380

    100

    6380

    100125160200225

    PHB226N-40kA

    Description

    MCCBMCCBMCCBMCCBMCCBMCCBMCCB

    PHB226E-70kAMCCBMCCBMCCBMCCBMCCBMCCBMCCB

    6380

    100125160200225

    6380

    100125160200225

    Rated current(A)

    ACCESSORY AND AUXILIARY EQUIPMENT

    Revolve the hand handle the organizationLocks-AA auxiliary switch,2NO+2NC-UV Owe-voltage trip,415V~-SR Cent trip,240V~-UV2 Owe-voltage trip,240V~

    80

    72

    80

    126

    101.

    7

    104.785.8

    81

    226

    PHB-126 3P

    PHB-226 3P

    MOULDED CASE CIRCUIT BREAKER

    PHB-126

    PHB-226

  • A C-15

    MOULDED CASE CIRCUIT BREAKER

    PTCD\PEB\PQD Series moulded case c ircuit breaker is one of our new type productsdeveloped and manufactured by adopting international adv anced technology. It is supplied withrated insulating voltage 660V and used for circuit of A.C.50Hz, rated operati ng voltage AC 380V.(Or below), rated operati ng current up to 22 5A for infre que nt cha ngi ng ove r and starting of the motors. Equipped with the protection devices for over-cur rent, shor t-circ uit a nd under-voltage, the products are capable of preventing damage of circuits and supply units.

    DIMENSIONS OF OUTLINE AND INSTALLATION (PQD)

    SPECIFICATION

    Model Pole Rated Current (A) Rated Insulation voltageRated operating

    voltage

    PTCD

    PEB

    PQD

    3 30,40,50,60,70,100

    125,150,175,200,225

    3

    3

    30,40,50,60,70,100 600V240V380V660V

    PTCD-100 3P

    PEB-100 3P

    PQD-250 3P

    243

    183

    6169

    35

    8

    487

    321 32

    27 14

    223 32

    1116 1 8

    3

    11 3219 32

    123 64

    3 81 4

    34

    2532

    5 329 16 2

    3

    1

    1116

    138

    1116

    138

    9 323

    4 81

    2 141 1 114

    2332 7 32

    19 32

    13

    4

    1 32

    122

    1516

    2 582 16143 14

    7

    116

    14 1

    5 32

    132

    MOULDED CASE CIRCUIT BREAKER

    PTCD-100

    DESCRIPTION

  • Type

    RDW1-2000

    RDW1-32004000

    RDW1-63004000/5000

    RDW1-6300

    Pole

    3P

    4P

    3P

    3P

    4P

    3P

    4P

    3P

    L1

    375

    470

    435

    550

    550

    813

    928

    928

    L2

    335

    430

    395

    510

    510

    773

    888

    888

    L3

    292

    292

    352

    352

    352

    352

    352

    352

    L4

    356

    360

    325

    440

    440

    703

    818

    818

    L5

    247

    247

    307

    307

    307

    307

    307

    307

    W1

    421

    494

    W2

    467

    540

    b

    139

    212

    In A

    10

    15

    20

    30

    20

    30

    RDW1-3200 could increase to 4000A,its installation dimension is same with RDW1-3200,4P

    RDW1-2000 cable dimensionfor with drawable type

    RDW1-3200 cable dimensionfor with drawable type

    RDW1-3200 In=4000A RDW1-6300, In=4000A, 5000Acable dimension for with drawable type

    RDW1-6300, In=6300Acable dimension for with drawable type

    RDW1-2000

    RDW1-3200

    RDW1 AIR CASE CIRCUIT BREAKER

    SCOPE OF APPLICATION

    400~630

    800~1600

    2000~2500

    3200~4000

    4000

    5000~6300

    a

    AIR CASE CIRCUIT BREAKER

    A C-16

  • RDW1 AIR CASE CIRCUIT BREAKER

    50kA/400V40kA/690V

    50kA/400V40kA/690V

    100kA/400V80kA/690V

    80kA/400V60kA/690V

    80kA/400V65kA/690V

    100kA/400V80kA/690V

    80kA/400V65kA/690V

    80kA/400V65kA/690V

    120kA/400V80kA/690V

    100kA/400V70kA/690V

    100kA/400V70kA/690V

    It can be used as controlling and protecting Electric Power Distribution line & Net. It is normally installed in Low-Volt age Sw itc hge ar as main Switch for total protection. The technical performance of our goods have reached advanced level of same item in the world.

    MAIN TECHNICAL PARAMETER

    Frame classing rated current

    Rated insulation voltage

    Rated voltage

    Rated current

    Rated ultimate short-circuit breaking capacity(lcu)

    Rated service short-circuit breaking capacity(lcs)

    Rated withshand current for short-time(lcw)

    Number of poles

    Arcing distance

    2000A 3200A 4000A 6300A

    690V

    400V

    630A,800A,1000A,1250A,1600A,2000A,2500A,3200A,4000A

    80kA/400V50kA/690V

    3P, 4P

    0

    Fault deviate indication/reposit pbutton

    Shut button

    Manua/Power store handle

    Dispart button

    Power store & releaseindication

    Shut & Dispart indication

    Panel

    In-Out devicePosition indication

    Shakable handle &its depositary

    Two times loop terminal connector(moving)

    Two times loop terminal connector(moving)

    Under-Uoltage reloaseDraw-out seatingShunt releaseAwciliary contactClose electromagnetIntelligent controller

    Electric operation frameworkOperation framework

    AC Rated Current:630A-3200ABreaking Capacity:80kA-100KA(virtual value)Rated working voltage: AC960VType:Draw-Out type and Fixed Mounted typeStandards: IEC60947-2, GB14048.2

    AIR CASE CIRCUIT BREAKER

    A C-17