2
Caledonian 9 ADDISON European Installation Bus(EIB) Cables PVC Insulation, PVC Outer Sheath European Installation Bus(EIB) Cables EIB Y(St)Y 2x2x0.8 Solid Copper Conductor PVC Insulation PVC Outer Sheath Overall AL/Polyester Tape With Tinned Copper Drain Wire APPLICATION EIB installation consists of sensors and actuators. The E.I.B. concept allows intergration of Building Management Systems (B.M.S.) over one common system. Lighting, blinds, heating and ventilation can be automatically controlled through the E.I.B cable. This dramatically reduces the cabling required in a modern building. They can be installed over, in, or below the plaster, in pipes and pipe ducts, in dry, moist, and wet areas, as well as outside, provided they are protected against direct exposure to the sun. STANDARDS Basic design to European Standard EN 50090 CABLE CONSTRUCTION Type/Cable Construction 1 Quad 2 Pair Inner Conductor Plain copper conductors 0.8mm Plain copper conductors 0.8mm Conductor Insulation PVC PVC Insulation Colour White,yellow,red,black White/yellow, red/black Stranding Element Cores twisted into a quad Cores twisted into pairs, pairs laid up Screen Aluminium/polyester foil screen Aluminium/polyester foil screen Drain Wire Solid copper Stranded tinned copper Outer Sheath PVC PVC

PE Insulation, PVC Outer Sheath European Installation Bus(EIB) Cables y(st)y

Embed Size (px)

DESCRIPTION

PE Insulation, PVC Outer Sheath European Installation Bus(EIB) Cables CABLE CONSTRUCTION Type/Cable Construction 1 Quad 2 Pair Inner Conductor Plain copper conductors 0.8mm Plain copper conductors 0.8mm Conductor Insulation PE PE Insulation Colour White,yellow,red,black White,yellow,red,black Stranding Element Cores twisted into a quad Cores twisted into pairs, pairs laid up Screen Aluminium/polyester foil screen Aluminium/polyester foil screen Drain Wire Solid copper Stranded tinned copper Outer Sheath PVC PVC www.caledonian-tech.net [email protected]

Citation preview

Page 1: PE Insulation, PVC Outer Sheath European Installation Bus(EIB) Cables y(st)y

Caledonian

9ADDISON

European Installation Bus(EIB) Cables

PVC Insulation, PVC Outer Sheath European Installation Bus(EIB) Cables

EIB Y(St)Y 2x2x0.8

Solid Copper Conductor

PVC Insulation

PVC Outer Sheath

Overall AL/Polyester Tape With Tinned Copper Drain Wire

APPLICATION

EIB installation consists of sensors and actuators. The E.I.B. concept allows intergration of Building Management Systems (B.M.S.) over one common system. Lighting, blinds, heating and ventilation can be automatically controlled through the E.I.B cable. This dramatically reduces the cabling required in a modern building. They can be installed over, in, or below the plaster, in pipes and pipe ducts, in dry, moist, and wet areas, as well as outside, provided they are protected against direct exposure to the sun.

STANDARDS

Basic design to European Standard EN 50090

CABLE CONSTRUCTION

Type/Cable Construction 1 Quad 2 PairInner Conductor Plain copper conductors

0.8mmPlain copper conductors 0.8mm

Conductor Insulation PVC PVCInsulation Colour White,yellow,red,black White/yellow, red/black Stranding Element Cores twisted into a quad Cores twisted into pairs, pairs laid

upScreen Aluminium/polyester foil

screenAluminium/polyester foil screen

Drain Wire Solid copper Stranded tinned copperOuter Sheath PVC PVC

Page 2: PE Insulation, PVC Outer Sheath European Installation Bus(EIB) Cables y(st)y

www.caledonian-cables.co.uk www.addison-cables.com

ADDISON

Caledonian10

COLOUR CODE

Insulation Colour:Pair1: Red/Black; Pair2: White/YellowSheath Colour: Green

ELECTRICAL PROPERTIES

Test Voltage 4000V

Working Voltage MAx.150V

Conductor resistance 37.0 Ohm/km @ 20°C

Insulation resistance 100MΩhms*km @ 20°C

Mutual capacitance@800Hz 100nF/km max

Unbalanced capacitance 300PF/100M MAx

TECHNICAL DATA:

Approx.Weight (kg/km) 62 57Nominal diameter(mm) 6.1 6.1Min. Bending Radius (Laying) 10 x OD mm 10 x OD mmOperating temperature, min -20°C(fixed) -5°C (installation)Operating temperature, max +70°C(fixed) +50°C (installation)

Rated Voltage

150V

NStandard

EN 50090