PDL500 SERIESELECTRICAL ACCESSORIES
VERSATILE AND RELIABLEACCESSORIES, DESIGNEDFOR SAFETY AND STYLE.
PDL ELECTRICALACCESSORIES
RTM
Page 1
With its leading-edge technology, PDL set a
new international standard with the 500
Series - the world’s first front-loading
modular system of electrical accessories.
In recognition of its innovation and design
excellence, the PDL 500 Series won the NZ
Designmark Award and was a finalist for the
Prince Philip Award.
The low-gloss finish of the 500 Series is both
attractive and practical and will blend in
superbly with any decor.
500 Series accessories are available in black
or white.
PDL 500 SERIES... WORLD-LEADING TECHNOLOGY
Page 2
Designed and manufactured by New
Zealanders for New Zealand homes and
buildings, the 500 Series is contractor
friendly. Behind the switch plates are a host
of innovative time-saving installation and
safety features.
The range is designed and engineered to
ISO 9001 and manufactured to ISO 9002.
Extensive testing at an independent Telarc
registered laboratory has included electrical
and mechanical endurance switching
equivalent to 100 years of ordinary use,
which gives PDL the confidence to offer a
two year warranty on the 500 Series range -
double the normal warranty.
FEATURESPDL 500 Series - packed with featuresfor quick, easy and safe installation.
Front loadingmechanismsFront-loading switchmodules cannot bepushed back into the wallcavity by frontal impact,saving low-profitmaintenance calls whilemaximising end-usersafety.
1
16 Amp switch ratingSwitches are rated at16 Amps as standard.That’s 60% higher thanthe 10 Amp rating ofother brands.
Backed-offterminal screwsAll switch and flat-platesocket terminal screwsin the 500 Series arebacked off forimmediate termination -bigger terminals providemore room for cableconductors.
Additional loopterminalAn additional loopterminal is fitted to theback of all singleswitches, saving bothtime and money.
Page 3
2
3
4
Strong on safetyIf a plug is partially pulledout of a 500 Series powersocket, the plug pins onlyremain live while there isa gap of 5mm betweenthe socket face plate andthe plug - not enoughroom for small fingers totouch the live pins.For additional safety, thesocket pin holes are fittedwith safety shutters.
Fixing screwsattachedFixing screws and screwcaps are now fitted to aneasy-to-remove clip,attached to the back ofthe plate.Fumbling with screwpacks or screwsfitted to flush plates isnow a thing of the past.
Page 4
5
Phillips/slottedscrew headsPDL’s terminal and fixingscrews featurePhillips/slotted screwheads which allow fittingand connections to bedone faster and moreeasily. The versatilescrew headsaccommodate either aPhillips or flat-bladedscrewdriver.
6
7
Low-gloss finishPDL’s 500 Seriesplates now feature alow-gloss finish that’selegant and easy toclean.
8
Page 5
All product development at PDL Industries iscontrolled by a quality management system accreditedto ISO 9001 and certified by Telarc New Zealand andASTA UK. ASTA is a significant UK-based certificationauthority.Independent third party quality systems accreditationreinforces, from an international perspective, theexcellence and quality of PDL products.
Independent third party testing,your guarantee of qualityThe design and manufacture of products by PDLIndustries has always been backed by third partytesting and development facilities.PDL uses Parkside Laboratories, an independentTelarc-registered electrical laboratory for its producttesting and Telarc-endorsed test reports to ensureinternational product acceptance.The laboratory, in addition to ensuring technicalquality levels are maintained on existing products, isan essential part of the development of new products,ensuring that PDL maintain the highest possiblestandards as the latest technological ideas areintroduced into our product ranges.This support for product development and anemphasis on testing and retesting prior to productrelease illustrates PDL Industries’ strong productdevelopment discipline, taking the concepts of qualitydesign well into the early design stages and rightthrough to introduction to manufacturing.
PDL proudly supports NewZealandBoth directly and indirectly, PDL Industries is aproud supporter of New Zealand and NewZealanders.Employees, customers and the community as awhole all benefit from PDL’s success. Businessgrowth is good for expanding job prospects both inthe number of new jobs and in enhanced careeropportunities. Customers benefit from better service and fromgoods that are competitive, innovative, addresstheir needs more closely and are delivered on time.The community benefits from the flow on effect.Suppliers of goods and services to the expandingcompany benefit find an increased demand for theirown products.From the country’s viewpoint, a successfulexporting company such as PDL is a benefitto all.
PDL Electrical Accessories are designed and engineeredto ISO 9001 in New Zealand by PDL Holdings
Engineering Centre and manufactured in New Zealand toISO 9002 by PDL Industries Ltd.
PDL ELECTRICALACCESSORIES
Continuous quality isquality you trust
RTM
NATIONALACCREDITATION
OF CERTIFICATIONBODIES
ISO 9002CERT NO. 11595
QU
ALIT
Y
ASSESSED
PDL Industries Limited,Telarc Reg. No. 061registered to ISO 9002.
REGISTEREDSUPPLIER
NEW ZEALAND MADE
PDL Industries uses an independent Telarc registeredelectrical laboratory for its product testing to ensurecontinuous quality.
QUALITY MANAGEMENT RECOGNISED BY TELARC & ASTA
Page 6
INDEX
SOCKETSVertical Switched Sockets __________ 23-24Horizontal Switched Sockets ________ 25-26Special Sockets for Solid Timber Walls _ 26Range Socket _____________________ 26Worktop Switched Sockets___________ 27Unswitched Socket _________________ 27Round Plate Sockets________________ 27Square Plate Sockets _______________ 27
ASSOCIATED ACCESSORIESShaver Sockets____________________ 28Threaded Socket___________________ 28TV Outlet_________________________ 28
MULTI-GANG STAINLESS STEELSWITCH PANELS
Stainless Steel Switch Plates _________ 29Switch Panel Wall Boxes_____________ 29
MOUNTING ACCESSORIESMounting Brackets _________________ 30Module Mounting Clips______________ 31Mounting Blocks & Spacers ________ 31-32Conversion Plate___________________ 32Flush Boxes ______________________ 32
FLOOR MOUNTED HOUSINGPower Tower______________________ 33
MISCELLANEOUS ACCESSORIESScrew Cap _______________________ 33Junction Boxes ___________________ 33Terminals ________________________ 33
INDEX BY CATALOGUE NUMBER500 Series Products ________________ 34
TECHNICAL DATAWiring Diagrams _________________ 35-38
SWITCHES Standard Switches _________________ 7Waterproof Switches, IP56___________ 7-8Waterproof Permanent Connection Unit, IP56 8Permanent Connection Unit __________ 8Range Switches ___________________ 8Dimmer Switches _________________ 9Key Card Operated Switches__________ 10Fan Control Switches _______________ 10Automatic Lighting Sensor Switch _____ 10Key Lock Switches _________________ 11Time Switches ____________________ 11Hot Water Switches ________________ 12Ceiling Switches ___________________ 12Surface Switches __________________ 12
SWITCH PLATESStandard Switch Plates______________ 13Architrave Switch Plates _____________ 13Worktop Switch Plates ______________ 13Surface Switch Plates_______________ 14
DATA OUTLET FACE PLATESData/Communication Plates __________ 14
SWITCH PLATE MODULES Module Ejector ____________________ 15Module Shroud____________________ 15IDC Terminating Tool _______________ 15Standard Switch Modules___________15-16Dedicated Switch Modules __________ 16Buzzer Modules __________________ 16Illuminated Modules_______________ 17Blank Modules ___________________ 17Rotary Switch Modules ____________ 17Push Button Switch Modules ________ 17Permanent Connection Module ______ 18Pull Cord Switch Modules __________ 18Dimmer Control Modules ___________ 18Communication Modules ___________18-19Telephone Jack Modules & Accessories 20
SAFETY SWITCHES & SOCKETS (RCDs)Safety Sockets ____________________ 21RCD Conversion Plate ______________ 21Safety Switches ___________________ 22
Page
581VWP SINGLE WATERPROOFSWITCH Plate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
583 TRIPLE SWITCHPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V, 146H, 148V or 148HMounting Bracket.
583
582VWP DOUBLE WATERPROOFSWITCH Plate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
582 DOUBLE SWITCH Plate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V, 146H, 148V or 148HMounting Bracket.
581HWP SINGLE WATERPROOFSWITCH Plate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H orCat 148H Mounting Bracket.
581 SINGLE SWITCH Plate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V, 146H, 148V or 148HMounting Bracket.1 x 501T included.
Page 7
SWITCHES16A Resistive, 16AX Inductiveand 8AX Fluorescent.DC Rating 12A, 12V/24V.Standard Switches comply with Standards: NZS/AS3100,NZS/AS3133 and BS3676.
Waterproof switches comply with Standards: NZS/AS3100,NZS/AS3133, BS3676 and AS1939.
Waterproof switches meet the requirements of NZECP 2(Section 4.4.3) of 1 April 1993 and are suitable forinstallation in Zone 2.
Permanent Connection Unit, Range Switches and DimmerSwitches comply with Standards: NZS/AS3100 and NZS/AS3133.
STANDARD SWITCHES
582
WATERPROOF SWITCHES, IP56
581VWP
582VWP
581HWP
581
551VWP WATERPROOF PERMANENTCONNECTION UNITPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
WATERPROOF PERMANENT CONNECTION UNIT, IP56
551VWP
Page 8
545 SINGLE POLE SWITCH Plate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.,45AX inductive and 45Aresistive, 1 Way. Has “E” & “N” loop terminals.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V, 146Vor 148V Mounting Bracket.545N As for 545 but fitted with neonto indicate "ON".547 DOUBLE POLE SWITCHPlate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 415V a.c., 45AXinductive and 45A resistive,1 Way.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V, 146Vor 148V Mounting Bracket.547N As for 547 but fitted with neonto indicate “ON”.579 SINGLE POLE SWITCHPlate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.,32A resistive, 32AX inductive.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V, 146Vor 148V Mounting Bracket.579/2 DOUBLE POLE SWITCHPlate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 400V - 415V a.c.,32A resistive, 32AX inductive.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V, 146Vor 148V Mounting Bracket.579HSINGLE POLE SWITCHAs for Cat 579 but horizontal.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.579H/2DOUBLE POLE SWITCHAs for Cat 579/2 buthorizontal.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.
RANGE SWITCHES
545 & 547
551 PERMANENT CONNECTIONUNITPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.16A inductive load, 16A resistive load.Fitted with 581M16 2 Wayswitch module and 551M2cord outlet and terminalblock.
PERMANENT CONNECTION UNIT
582HWP DOUBLE WATERPROOFSWITCHPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.
WATERPROOF SWITCHES, IP56 Cont...
551
579H & 579H/2
582HWP
579 & 579/2
522 TOUCH SWITCH DIMMERPlate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 500W max.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.Not suitable for controllingtransformer lighting orfluorescent lamp loads.
522LV TOUCH SWITCH DIMMER Plate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.,400W max.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.Low voltage dimmer forcontrolling the primarypower supply of atransformer operatingtungsten halogen low voltlamps.Not suitable for fluorescentlamp loads.
523 TOUCH SWITCH DIMMER,REMOTEPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.Dimmer operates throughcomplete cycle of full “ON” tomaximum Dim bymaintaining finger touch.Touching the plate will turnthe light “ON” at fullillumination.Neon power indicator.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.Provides 2 Way switchingwhen used with Cat 522 or522LV.
520 ROTARY DIMMERPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 400W max.Fitted with 581M16 2 Wayswitch module and 520MRotary Dimmer module.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
520K ROTARY DIMMERPlate: 118mm x 74mm.Mounting centres 84mm.Rated at 230V - 240V a.c., 1000W max.
520
DIMMER SWITCHES
Page 9
522 & 523
Page 10
525 FAN CONTROL SWITCHPlate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 300VA max.Suitable for induction andshaded pole motors.Features adjustableminimum speed control.
FAN CONTROL SWITCHES
525
525X FAN CONTROL SWITCHAs for 525 but with an extra581M16 2 Way switchmodule.
525X
526NKEY CARD SWITCH 2 module switch with neonlocator and Key Card.Plate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c. Fitted with 2 x 581M16 2Way switch modules and 2 x 500B Module Blanks.Switches can only beoperated by the key cardwhich is inserted via thebottom slot.
KEY CARD OPERATED SWITCHES
526N
AUTOMATIC LIGHTING SENSOR SWITCH
556 PIR SENSOR SWITCH Plate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.500W max incandescent.250W max fluorescent.Interior sensor whichreplaces standard switch andturns lights ON automaticallywhen it senses movement. Field of view - 90° elliptical.Range - 5m forward and 2meither side of centre.Time setting - 20 seconds to10 minutes.Lux setting - 5 Lux upwards.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
526KC KEY CARD ONLYFor use with 526N.
556
546R24ROTARY TIMER with SHIELDPlate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V-240V a.c.,16A resistive and 8AXinductive.Programmable Auto –Manual – OFF.N/C and N/O contacts.Time selection increments of20 minutes to 24 hours.Suits Cat 144 Flush Box.Not suitable for surfacemounting.
568 KEY LOCK SWITCHLOCKABLE “ON” OR “OFF”Plate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 16A, 2 Way.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
568ON KEY LOCK SWITCHLOCKABLE “ON”Plate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 16A, 2 Way.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
568OFF KEY LOCK SWITCHLOCKABLE “OFF”Plate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 16A, 2 Way.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
568, 568ON & 568OFF
KEY LOCK SWITCHES532 TIME DELAY SWITCHPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V-240V a.c.,16AX resistive and inductive.Switch operates light and fantogether or independently.When light is turned OFF, fancontinues for 8 minutes.Fan load 100VA max.
TIME SWITCHES
532
546 UNIVERSAL TIME SWITCHPlate: 118mm x 74 mm.Mounting centres: 84mm.Rated at 230V-240V a.c.,10AX resistive and inductive.Can be set to switch a loadeither ON or OFF for aselected time period from1 sec to 31.5 hours.
546
Page 11
546R24
Page 12
572 HOT WATER SYSTEM SWITCHPlate: 66mm diameter.Mounting centres: 50mm at 45°.Round surface mounting.Rated at 230V - 240V a.c.Fitted with 580M20HWS 1 Way 20A switch forconduit box mounting.
548BSSOLAR WATER HEATERBOOSTER SWITCHPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 20A.Operates when a voltageacross the line terminals ispresent. Provides a boost ofelectric heat when waterusage exceeds the capabilityof the solar water heatingsystem.
571 ROUND SWITCH SURFACE KITPlate: 56mm diameter.Mounting centres: 40mm.Rated at 230V - 240V a.c.Made up of 571R with581M16 2 Way switchmodule and 530 RoundSurface Mounting Block.
SURFACE SWITCHES
571
580D SURFACE SWITCHPlate: 74mm x 74mm x30mm.Mounting centres: 52mm.Rated at 230V - 240V a.c.581M16 2 Way switchmodule in a square deepplate.
573 PULL CORD SWITCHPlate: 66mm diameter.Mounting centres: 50mm.Rated at 230V - 240V a.c.Fitted with 581M16PS 2 WayPull Cord Switch module.16A resistive, 16A inductive,8AX fluorescent.
HOT WATER SWITCHES
574 HOT WATER SYSTEM SWITCHPlate: 79mm x 52mm.Surface mounting.Rated at 230V - 240V a.c. Two fixing points, fitted with580M20HWS. 1 Way 20A switch.Clamp provided for conduitand flexible cord.2 x 501T terminals included.
574D32 As for 574 but rated at 32A.
574
580D
CEILING SWITCHES
572
573548BS
574D32
573N NEON PULL CORD SWITCHPlate: 66mm diameter.Mounting centres: 50mm.Rated at 230V - 240V a.c.Fitted with 580M16NPS 1 Wayneon Pull Cord Switch module.Neon can be wired:• Permanently ON• ON to indicate ON• ON in the OFF position as a
locator.573N
581VH ONE APERTURE PLATE Plate: 118mm x 74mm.Mounting centres: 84mm.
582VH TWO APERTURE PLATE As for 581VH but with 2apertures.
STANDARD SWITCH PLATES
581VH583VH THREE APERTURE PLATE As for 581VH but with 3apertures.
584VH FOUR APERTURE PLATE As for 581VH but with 4apertures.
586VH SIX APERTURE PLATE As for 581VH but with 6apertures.
584VH
550VHTBLANK JUNCTION PLATEPlate: 118mm x 74mm. Mounting centres: 84mm.Has 3 x 32A terminalsattached to the plate.
550VHT
550VH BLANK PLATEPlate: 118mm x 74mm. Mounting centres: 84mm.Suits Cat 89 Mounting Block,Cat 144 Flush Box and Cat145V, 148V or 148HMounting Bracket.
561VH ONE APERTURE PLATE Plate: 78mm x 32mm.Mounting centres: 62mm.Suits Cat 560 MountingBlock.
562VH TWO APERTURE PLATEPlate: 78mm x 32mm.Mounting centres: 62mm.Suits Cat 560 MountingBlock.
ARCHITRAVE SWITCH PLATES
561VH
563VH THREE APERTURE PLATE Plate: 130mm x 32mm.Mounting centres: 114mm.Suits Cat 565 MountingBlock.
564VH FOUR APERTURE PLATE Plate: 130mm x 32mm.Mounting centres: 114mm.Suits Cat 565 MountingBlock.
563VH
588VH ONE APERTURE PLATE Plate: 100mm x 48mm.Mounting centres: 80mm.Suits Cat 558 MountingBracket and Cat 567SMounting Block.
WORKTOP SWITCH PLATES
588VH
589VH TWO APERTURE PLATE Plate: 100mm x 48mm.Mounting centres: 80mm.Suits Cat 558 MountingBracket and Cat 567SMounting Block.
SWITCH PLATES
Page 13
589VH550VH
514VH15/1 ONE APERTURE PLATE Plate: 118mm x 74mm. Mounting centres: 84mm.Suits DB15 Panel Mount Outlet.
514VH15/2 TWO APERTURE PLATE As for 514VH15/1 but with 2 apertures.
514VH25/1 ONE APERTURE PLATEPlate: 118mm x 74mm. Mounting centres: 84mm.Suits DB25 Panel Mount Outlet.
514VH25/2 TWO APERTURE PLATE As for 514VH25/1 but with 2 apertures.
514VH9/1 ONE APERTURE PLATEPlate: 118mm x 74mm. Mounting centres: 84mm.Suits DB9 Panel MountOutlet.
514VH9/2 TWO APERTURE PLATEAs for 514VH9/1 but with 2 apertures.
Page 14
571RONE APERTURE PLATEPlate: 56mm diameter.Mounting centres: 40mm.Suits Cat 530 RoundMounting Block.
571R
573R ONE APERTURE PLATE Plate: 66mm diameter.Mounting centres: 50mmat 45°. Plate can be mounted onround conduit box.
573R
SURFACE SWITCH PLATES
DATA OUTLET FACE PLATES
512VH/1 ONE APERTURE PLATEPlate: 118mm x 74mm. Mounting centres: 84mm.Suits IBM data connectionsocket.
512VH/1
513VH/1 ONE APERTURE PLATE Plate: 118mm x 74mm. Mounting centres: 84mm.Suits Twinax Panel MountOutlet.
513VH/2 TWO APERTURE PLATE As for 513VH1 but with 2apertures.
513VH/2
514VH9/2
514VH25/2
504VH/1 ONE APERTURE PLATEPlate: 118mm x 74mm. Mounting centres: 84mm.Thinnet plate to suit AMPEthernet panel connector.
DATA/COMMUNICATION PLATES
504VH/1
Switch modules are compatible with both 500 Series and 600Designer Series plates.
The modules clip into PDL’s switch plates from the front formaximum impact strength.
A module ejector tool for removing or replacing modules isavailable free of charge from your local PDL Representative.
SWITCH PLATE MODULES
Page 15
578M16INTERMEDIATE SWITCHMODULERating: 230V - 240V a.c., 50Hz.,
16A Resistive,8AX Fluorescent and16AX Inductive.
680M32SWITCH MODULERating: 230V - 240V a.c., 50Hz.,
32A Resistive.1 Way.Terminals accommodate3 x 6mm2 conductors.
680M32
STANDARD SWITCH MODULESTerminals accommodate: 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each,except Cat 680M32.
581M16
581M16SWITCH MODULERating: 230V - 240V a.c., 50Hz.,
16A Resistive,8AX Fluorescent and16AX Inductive.2 Way.
MODULE EJECTOR
500ME
500MEFor removing 500 Seriesand 600 Designer Seriesswitch modules from plates.Collapses module clip-inlegs simultaneously andejects module.
680S
680S MODULE SHROUDFlame retardent material.Insulates up to 3000V.Suits all 500 Series and600 Designer Seriesmodules.
MODULE SHROUD
500TTIDC TERMINATING TOOLFor use with Cat 617M2,517M, 518M, 519M6 and519M8.
500TT
IDC TERMINATING TOOL
578M16
32A
Page 16
581M16A/M
580M20HWSHOT WATER SWITCH MODULERating: 230V - 240V a.c.,20A Resistive rating only forhot water system.1 Way.Rocker marked “HWS”.
580M20HWS
STANDARD SWITCH MODULES cont...
581M16P
580M16N
580M16NNEON SWITCH MODULERating: 230V - 240V a.c., 16A. 1 Way.Neon flying leads can beconnected ‘permanently on’ orcan be connected to indicatewhen the switch is ‘on’ or ‘off’.
581M16P NORMALLY OPEN SWITCHMODULERating: 230V - 240V a.c.,16A. Spring return, 2 Way.Rocker marked “PRESS”.
581M16BAs for 581M16P but rockermarked with “BELL” symbol.
581M16RAs for 581M16P but rockermarked “RESET”.
Rating: 230V - 240V a.c.,16A. 2 Way switch module.
581M16A/MMarked “AUTO/MANUAL”.
581M16F Marked “FAN”.
581M16FG Marked“FRIDGE”.
581M16F/R Marked“FORWARD/REVERSE”.
581M16HMarked “HEAT”.
581M16HFL Marked“HIGH/FAN/LOW”.
581M16I/0 Marked“ON/OFF”.
581M16L Marked “LIGHT”.
581M16MWMarked “MICROWAVE”.
581M16SE Marked“SENSOR”.
581M16S/W Marked“SUMMER/WINTER”.
581M16TV Marked “TV”.
581M16WH Marked“WASH”.
581M16WT Marked“WASTE”.
581M16H
DEDICATED SWITCH MODULES
566MNCBPIEZO BUZZERRating: 24V d.c.Screw terminals.Sound level 90dB.
566MNCB
1588M
BUZZER MODULES
1588MBUZZER MODULERating: 240V a.c.Terminal connection: flyingleads.Sound level ≥ 70dB.
587M10DOUBLE POLE SWITCHMODULERating: 230V - 240V a.c., 50Hz.,
10A Resistive and10AX Inductive.
587M10
Terminals accommodate: 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each.
Page 17
510MN ILLUMINATED MODULERating: 230V - 240V a.c.Two terminals for directconnection to neon. Availablewith RED,GREEN, AMBER,BLUE and CLEAR coloured lens.510ML12ILLUMINATED MODULERating: 12V a.c./d.c.Available with RED, GREEN,AMBER, BLUE or CLEARcoloured lens.
581M16PBP PROTRUDING PUSH BUTTONMODULEN/O-N/C.Ratings to AS1431 Pt. 1.Insulation Voltage 500V a.c.Operational Voltage230V - 240V a.c.Thermal Current 16A.Operational Current 4A.240V a.c.Operational Current 2A.415V a.c.Utilisation Category AC 11.Degree of Protection IP40.Available with RED, WHITE orYELLOW button.
581M16PBP
PUSH BUTTON SWITCH MODULES
581M16PBS
581M16PBS SHROUDED PUSH BUTTONMODULEN/O-N/C.As for 581M16PBP butavailable with RED, WHITE,GREEN or BLACK button.
581M16PBM
581M16PBM MUSHROOM PUSH BUTTONMODULEN/O-N/C.As for 581M16PBP butavailable with RED, WHITE orGREEN button.
515MS
510MN
ILLUMINATED MODULES
510ML24ILLUMINATED MODULERating: 24V a.c./d.c.Available with RED, GREEN,AMBER, BLUE or CLEARcoloured lens.
510MLD24
510MLD24ILLUMINATED MODULEDEEP LENSRating: 24V a.c./d.c.Available with RED, GREEN,AMBER, BLUE or CLEARcoloured deep lens.
Terminals accommodate 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each.
Terminals accommodate 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each.
515MSOPAL NEON SYMBOL MODULERating: 230V - 240V a.c.Two terminals for directconnection to neon. Symbolsavailable:
500B
500B BLANK MODULE
500BSTMarked “START”.
500BSPMarked “STOP”.
500BESPMarked “EMERGENCY STOP”.
BLANK MODULES
687M3ROTARY SWITCH MODULERating: 230V - 240V a.c., 16A.Three-position switch module:
AUTO, OFF, MAN orI, 0, II or0, 1, 2.
687M4ROTARY SWITCH MODULERating: 230V - 240V a.c., 16A.Four-position switch module:
0, 1, 2, 3.Other configurations availableupon request.
687M4
ROTARY SWITCH MODULESTerminals accommodate 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each.
NO SMOKING
SHOWER ON
WAITER
ROOM SERVICE
DO NOT DISTURB
Page 18
PERMANENT CONNECTION MODULE
551M2
551M2PERMANENT CONNECTIONMODULERating: 230V - 240V a.c., 16A.“Bell Mouth” cable entryaccommodates flexible cordsup to 10mm diameter.
Terminals accommodate 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each.
COMMUNICATION MODULES
581M16PS
580M16NPS PULL CORD SWITCHMODULE WITH NEONRating: 230V - 240V a.c., 16A. 1 Way.Outer body red transparent.Neon flying leads can beconnected ‘permanently on’or can be connected to indi-cate when the switch is ‘on’or ‘off’.
581M16PS PULL CORD SWITCHMODULERating: 230V - 240V a.c.,
16A Resistive,8AX Fluorescent and 16A Inductive. 1 Way/2 Way.
580M16NPS
PULL CORD SWITCH MODULES
521M
521M REMOTE CONTROL POT2 wire remote dimmingpotentiometer.Rating of pot 470K Ohm.
520M ROTARY DIMMER MODULERating: 230V - 240V a.c.,400W max.Incandescent loads only.
520M
DIMMER CONTROL MODULES
Terminals accommodate 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each.
573MMMOMENTARY CONTACTPULL CORD SWITCHMODULERating: 12V a.c., 12A.N/O - N/C.Red button and actuator.
573MM
Terminals accommodate 4 x 1.5mm2 cables each or 2 x 2.5mm2 cables each.
516M
516M BNC SOCKETRating: 50 Ohm.Solder terminals.
615MF
615MF‘F’ TYPE CONNECTORMODULE‘F’ Female/Female throughconnector.
540 RCA -1/4" PHONOHead Phone Adaptor.
540
Page 19
528M
509M TV-FM SPLITTER SOCKETMODULESingle coaxial connection tocombined TV-FM aerial. Suits 75 Ohm coaxial cable.Comprising screw terminal forsignal core and saddle clampfor earth screen.Marked “TV” and “FM” onrespective modules.Suits 562VH, 563VH, 564VH,582VH, 583VH, 584VH,586VH and 589VH.Can be used as an outlet onmaster aerial systems.
528M COAXIAL CABLECONNECTION SOCKETRating: 75 Ohm.PAL type socket.Clamp terminals.
528MIPAL ISOLATED MODULERating: 75 Ohm.PAL type socket.Cable connection coaxialsocket module.Mains isolated for 240V a.c.For additional protection.
529MAs for 528M but marked “FM”.
509M
527PCOAXIAL PLUGRating: 75 Ohm.For use with 528M and529M sockets.
527P
COMMUNICATION MODULES Cont . . .
541M RCA AUDIOCONNECTION SOCKETSolder type terminals.Socket coloured RED.Gold-plated.
542MAs for 541M but socketcoloured BLACK.
541M
615MST
615MST‘ST’ TYPE FIBRE OPTICCONNECTOR MODULE‘ST’ multi-mode throughconnector.Comes with two yellow dustcovers in place.
615MBB
615MBBBANANA BINERY POSTRating: 250V a.c., 12V d.c.,10ASuits standard banana plug.Accepts wire and forkedterminal connections.Gold-plated with black band.
615MRBAs for 615MBB but with a redband.
Page 20
524VH TELEPHONE COVER PLATEPlate: 118mm x 74mm.Mounting centres: 84mm.Plate fits over Telecomsquare plate to allowconversion to standard platesize.
524VH
511VH TELEPHONE JUNCTION PLATEPlate: 118mm x 74mm.Mounting centres: 84mm.For joining up to six sets oftelephone cables using IDCterminals.Approved to TelepermitPTC 203.
511VHTELEPERMITA P P R O V E D
TELEPHONE JACK MODULES & ACCESSORIES
517M
517M BT OUTLET JACKIDC connections.For master connection.Approved to Telepermit PTC203.
TELEPERMITA P P R O V E D
617M2
617M2BT OUTLET JACKTwo-wire outlet for two-wireinstallations.IDC connections.Two-wire outlets are notcompatible with three-wiresystems.Approved to Telepermit PTC223.
TELEPERMITA P P R O V E D
519M6FCC 6 WAY OUTLET JACKIDC connections.For secondary connections.
519M6
518M
518M BT OUTLET JACKIDC connections.For secondary connections.Approved to Telepermit PTC203.
TELEPERMITA P P R O V E D
519M8 FCC 8 WAY OUTLET JACKIDC connections.Data & voice connection.Suits RJ45 plugs.
519M8
591CPRCD CONVERSION PLATE
With PDL’s conversion plate(Cat 591CP), the 591FRCDcan be installed inbathrooms to replace anexisting PDL 63T shaver unit.
Simply fit the 591FRCD tothe conversion plate usingthe existing wall box.
Page 21
591FRCDPOWERGUARDRCD PROTECTED SOCKETPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 20A.Tested to AS3190:1990 andAS3112:1990.Single, vertical switchedsocket outlet incorporating30mA RCD protection.Switches off the current within30ms if electrical leakage toearth exceeds as little as 30mA.Provides RCD protection to allsockets wired downstream.Fitted with safety shutters.Suits Cat 89DP MountingBlock, Cat 144 Flush Box andCat 145V, 146V or 148VMounting Bracket.
SAFETY SOCKETS
591FRCD575VRCD
Each PDL RCD has a 300V MOV internally fitted across theinput conductors. This primarily provides power surge protection to the RCD’s electronic components. However,it also provides surge protection to appliances connectedto the RCD.
The maximum energy that can be absorbed is 40 joules.
RCD CONVERSION PLATE
SAFETY SWITCHES & SOCKETS (RCDs)
575VRCD POWERGUARD RCDPROTECTED SOCKET/SHAVER SOCKETPlate: 175mm x 100mm.Mounting centres: 145mm.Comprises RCD ProtectedSocket and Universal ShaverSocket on one plate. Suits Cat575MB metal flush box.
RCD Protected SocketRated at 230V - 240V a.c.Rated Current: 10A SocketOutlet.Tested to AS3100, AS3190 &AS 3194.Single switched socket outletincorporating 30mA RCD protection. Switches off thecurrent within 30ms if electrical leakage to earthexceeds as little as 30mA.Fitted with safety shutters.
Universal Shaver SocketRated at 230V - 240V a.c.primary and 240V - 115V a.c.secondary, 20VA max. Doubleinsulated. Switches on whenplug is inserted. Fitted withsafety shutters.
591CP
596RCDPOWERGUARDPLATE MOUNTED RCD Plate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 20A.Tested to AS3190:1990 andAS3100:1990. Plate mounted RCD whichprotects all socket outlets orpermanently-wiredappliances wired downstream.Switches off the currentwithin 30 ms if electricalleakage to earth exceeds aslittle as 30mA.Suits Cat 89DP MountingBlock, Cat 144 Flush Box andCat 145V, 146V or 148VMounting Bracket.
SAFETY SWITCHES
596RCD
596/56RCD POWERGUARD PLATE MOUNTED RCDPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c.,20A.Protected to IP56.Tested to AS3190:1990 andAS3100:1990. Plate mounted RCD which protects all socket outlets orpermanently-wiredappliances wired downstream.Its IP56 flush plate allows it tobe used in damp or dustyconditions.Switches off the current within 30 ms if electrical leakage to earth exceeds aslittle as 30mA.Suits Cat 89DP MountingBlock, Cat 144 Flush Box andCat 145V, 146V or 148VMounting Bracket.
596/56RCD
Page 22
If a plug is partially pulled out of a PDL 500 Series powersocket, the plug pins only remain live while there is a gap of5mm between the socket face plate and the plug - not enoughroom for small fingers to touch the live pins.
For additional safety, the socket pin holes are fitted withsafety shutters.
Switched sockets comply with the following Standards:AS3100, AS3112 and NZS198.
591FRSINGLE SWITCHED SOCKETwith ROUND EARTH PINPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
591F/15SINGLE SWITCHED SOCKET 15APlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 15A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
Page 23
591FSINGLE SWITCHED SOCKETPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
591FNAs for 591F but fitted withneon to indicate “ON”.
VERTICAL SWITCHED SOCKETS
591FPSINGLE SWITCHED SOCKETwith “RCD ON” INDICATORPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.AMBER glowing “RCD ON”indicator. Neon is replaceable.
591FXSINGLE SWITCHED SOCKETwith EXTRA SWITCHAs for 591F but fitted with anextra 10A, 1 Way switch.Sockets with engraved extraswitch available on request.
591FXNAs for 591FX but fitted withneon to indicate “ON”.
591FX
592FDOUBLE SWITCHED SOCKETPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
592FNAs for 592F but fitted withneon to indicate “ON”.
SOCKETS
591F
591FP
591F/15
591FR
592FN
592FXDOUBLE SWITCHED SOCKETwith EXTRA SWITCHAs for 592F but fitted withan extra 10A, 1 Way switch.Sockets with engraved extraswitch available on request.
592FXNAs for 592FX but fitted withneon to indicate “ON”.
592F/15DOUBLE SWITCHED SOCKET 15APlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 15A.Suits Cat 89, 536 or 537Mounting Block, Cat 144 FlushBox and Cat 145V, 146V or148V Mounting Bracket.
592FPDOUBLE SWITCHED SOCKETwith “RCD ON” INDICATORPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.AMBER glowing “RCD ON”indicator. Neon is replaceable.
VERTICAL SWITCHED SOCKETS Cont...
Page 24
592FRDOUBLE SWITCHED SOCKETwith ROUND EARTH PINPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144 FlushBox and Cat 145V, 146V or148V Mounting Bracket.
592F/15592FX
592FP592FR
594FPSINGLE SWITCHED SOCKETwith “RCD ON” INDICATORPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.AMBER glowing “RCD ON”indicator. Neon is replaceable.
594FRSINGLE SWITCHED SOCKETwith ROUND EARTH PINPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.
594F/15SINGLE SWITCHED SOCKET 15APlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 15A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.
Page 25
595FDOUBLE SWITCHED SOCKETPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144 FlushBox and Cat 146H or 148HMounting Bracket.
595FNAs for 595F but fitted withneon to indicate “ON”.
594F/15
594FR
595F
594FP
594FXSINGLE SWITCHED SOCKETwith EXTRA SWITCHAs for 594F but fitted with anextra 10A, 1 Way switch.Sockets with engraved extraswitch available on request.
594FXNAs for 594FX but fitted withneon to indicate “ON”.
594FSINGLE SWITCHED SOCKETPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144 FlushBox and Cat 146H or 148HMounting Bracket.
594FNAs for 594F but fitted withneon to indicate “ON”.
HORIZONTAL SWITCHED SOCKETS
594FN
594FX
595FRDOUBLE SWITCHED SOCKETwith ROUND EARTH PINPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.
595FPDOUBLE SWITCHED SOCKETwith “RCD ON” INDICATORPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.AMBER glowing “RCD ON”indicator. Neon is replaceable.
595FXDOUBLE SWITCHED SOCKETwith EXTRA SWITCHAs for 595F but fitted withan extra 10A, 1 Way switch.Sockets with engraved extraswitch available on request.
595FXNAs for 595FX but fitted withneon to indicate “ON”.
595FX
595FP
595F/15DOUBLE SWITCHED SOCKET 15APlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 15A.Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 146H or148H Mounting Bracket.
Page 26
595F/15
595FR
595LDOUBLE SWITCHED SOCKETLarge split-level plate: 86 x145mm.Mounting centres: 120mm.Rated at 230V - 240V a.c., 10A.Designed for solid timberwalls. Comes complete withdrilling template.
595LN As for 595L but fitted withneon to indicate “ON”.
576 RANGE SOCKETPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V- 400V a.c.,32A max, single or twophase cookers. 4 pin. Recommended for use with6mm2 two core with Earth orthree core with Earth TPS.Complies with AS3100 andAS3131.Suits Cat 144 Flush Box orCat 89 or 537 MountingBlock. Compatible with Cat976 Range Plug.
RANGE SOCKET
595LX DOUBLE SWITCHED SOCKETAs for 595L but fitted with anextra 10A, 1 Way switch.
595LXN As for 595LX but fitted withneon to indicate “ON”.
SPECIAL SOCKETS FOR SOLID TIMBER WALLS
595L
595LX
576
HORIZONTAL SWITCHED SOCKETS cont...
570R ROUND PANEL MOUNTSOCKETPlate: 56mm diameter.Mounting centres: 40mm.Rated at 230V - 240V a.c., 10A. Suits Cat 530 RoundMounting Block.
570R/15As for 570R but rated at 15A.
598FSINGLE SWITCHED SOCKETPlate: 100mm x 48mm.Mounting centres: 80mm.Rated at 230V - 240V a.c., 10A.Suits Cat 558 MountingBracket or Cat 567SMounting Block.
598FN As for 598F but fitted withneon to indicate “ON”.
599FDOUBLE SWITCHED SOCKETPlate: 170mm x 48mm.Mounting centres: 150mm.Rated at 230V - 240V a.c., 10A.Suits Cat 559 MountingBracket or Cat 567LMounting Block.
599FN As for 599F but fitted withneon to indicate “ON”.
597 SINGLE SWITCHED SOCKETSplit-level plate: 170mm x48mm.Mounting centres: 150mm.Rated at 230V - 240V a.c., 10A.Has 2 blank modules toaccept 500 Series switchmechanisms. Suits Cat 559Mounting Bracket orCat 567L Mounting Block.
597N As for 597 but fitted withneon to indicate “ON”.
597
598F
WORKTOP SWITCHED SOCKETS593 SINGLE UNSWITCHED SOCKETSplit-level plate: 118mm x74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A. Suits Cat 89, 536 or 537Mounting Block, Cat 144Flush Box and Cat 145V,146V or 148V MountingBracket.
UNSWITCHED SOCKET
593
ROUND PLATE SOCKETS
570R
570S SQUARE PANEL MOUNT SOCKETPlate: 51mm x 51mm x 9mm.Mounting centres: 38mm.Rated at 230V - 240V a.c., 10A. Supplied with panel clampfor fitting throughrectangular entry 38mm wide x 31mm high.
570S/15As for 570S but rated at 15A.
SQUARE PLATE SOCKETS
570S
Page 27
599F
575 SHAVER SOCKETPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c. primary and 240V-115V a.c.secondary, 20VA max.Vertical or horizontalmounting. Double insulated. Switches on when plug isinserted. Comes completewith Cat 557 spacer to beused with Cat 89 MountingBlock for surface mounting.Also comes complete withCat 144 Flush Box.(Refer also to 575VRCD P21.)
SHAVER SOCKETS
575
1575 SHAVER SOCKETPlate: 146mm x 90mm.Mounting centres: 120mm.Rated at 230V - 240V a.c.primary and 240V - 115V a.c.secondary, 20VA max.Vertical or horizontalmounting.Double insulated. Switches on when plug isinserted. This socket replaces PDL’s63T Shaver Socket.
1575
593LRP SINGLE THREADED SOCKETwith PLUGPlate: 118mm x 74mm.Mounting centres: 84mm.Rated at 230V - 240V a.c., 10A. Comes complete with Cat 905LR. Suits Cat 537 or 89Mounting Block, Cat 144Flush Box and 145V, 146V or148V Mounting Bracket.
THREADED SOCKET
593LRP
Page 28
ASSOCIATED ACCESSORIES
528TV OUTLETPlate: 118mm x 74mm.Mounting centres: 84mm.PAL type socket with clampterminals.Suits Cat 89, 536 or 537Mounting Block, Cat 144 FlushBox and Cat 145V, 146V, 146H,148V or 148H MountingBracket.
TV OUTLET
528
534P8SSTAINLESS STEEL SWITCH PLATE8 WAYSize: 128mm x 220mm.Supplied with 8 x Cat 533Module Mounting Clips.
STAINLESS STEEL SWITCH PLATES
534P8S
534P16SSTAINLESS STEEL SWITCH PLATE16 WAYSize: 220mm x 220mm.Supplied with 16 x Cat 533Module Mounting Clips.
534P16S
534P24S STAINLESS STEEL SWITCH PLATE24 WAYSize: 313mm x 220mm.Supplied with 24 x Cat 533Module Mounting Clips.
534P24S
534B8 SWITCH PANEL WALL BOX8 WAYSize: 108mm x 200mm x 60mm deep.1 earth terminal.Side knockouts: 2 x 38mm, 4 x 25/21mm.Back knockouts: 11 x 38mm, 2 x 25/21mm.
SWITCH PANEL WALL BOXES
534B8
534B16 SWITCH PANEL WALL BOX16 WAYSize: 200mm x 200mm x60mm deep.1 earth terminal.Side knockouts: 2 x 38mm, 4 x 25/21mm.Back knockouts: 2 x 38mm, 4 x 25/21mm.
534B16
534B24SWITCH PANEL WALL BOX24 WAYSize: 293mm x 200mm x60mm deep.1 earth terminal.Side knockouts: 2 x 38mm,4 x 25/21mm.Back knockouts: 3 x 38mm,4 x 25/21mm.
534B24
PDL’s switch panels accept all 500 Series modules but theymust be ordered separately. Standard plate finish is brushedstainless steel but polished brass plates are available onrequest. Mounting Boxes are supplied separately.
Page 29
MULTI-GANG STAINLESS STEEL SWITCH PANELS
145V VERTICAL BRACKET 84mm product mountingcentres.Nails can be inserted at theside.Suits all standard plate size 500 Series accessories.
145V
MOUNTING ACCESSORIESSwitches and switched sockets suit Cat 89, 536 or 537Mounting Block.
RCDs suit Cat 89DP Mounting Block.
558 HORIZONTAL BRACKET FOR WORKTOP PLATES80mm product mountingcentres.Suits Cat 588VH, 589VH,598F and 598FN.
559 HORIZONTAL BRACKET FOR WORKTOP PLATES150mm product mountingcentres.Suits Cat 597, 597N, 599Fand 599FN.
MOUNTING BRACKETS
558
148H HORIZONTAL BRACKET 84mm product mountingcentres.Opening 52mm x 76mm.Suits all standard plate size 500 Series accessories.
148H
148V VERTICAL BRACKET 84mm product mountingcentres.Opening 52mm x 76mm.Suits all standard plate size 500 Series accessories.
148V
Page 30
146V VERTICAL BRACKET Nailed stud bracket forstandard plate size 500Series accessories.84mm product mountingcentres.
146V
146HHORIZONTAL BRACKET Nailed stud bracket forstandard plate size 500Series accessories.84mm product mountingcentres.
146H
Page 31
557 MOUNTING BLOCK SPACERSize: 118mm x 75mm x 12mm.For use with Cat 89Mounting Block for surfacemounting extra deepelectrical accessories egCat 575 Shaver Socket.
557
531 SPACER (standard size)Size: 118mm x 75mm x 13mm deep.84mm product mountingcentres.
531
89 UNIVERSAL MOUNTINGBLOCKSize: 122mm x 80mm x 30mm deep.84mm product mountingcentres.Suits all standard size 500 Series accessories.
89SPAs for 89 but 18mm deep.
89DPAs for 89 but 37mm deep.
89
537 DEEP MOUNTING BLOCK Size: 120mm x 77mm x 35mm deep.84mm product mountingcentres.Knockouts same as Cat 536.Suits all standard size 500Series accessories.
537
536 SHALLOW MOUNTING BLOCK(standard size)Size: 119mm x 76mm x25mm deep.84mm product mountingcentres.4 x 25mm knockouts,12 x 20mm knockouts,12 x 16mm knockouts, 12 TPS cable knockouts.Suits all standard size 500Series accessories.
536
530 ROUND MOUNTING BLOCKSize: 65mm diameter x 22mmdeep.Mounting centres: 50mm at 45°.Suits conduit box covercentres.Knockout for 20mm flexconduit.Suits Cat 571R and Cat 570R.
MOUNTING BLOCKS & SPACERS
530
539 MOUNTING CLIP 40mm mounting centres forscrew fixing.Suits all 500 Series and 600Designer Series modules.
MODULE MOUNTING CLIPS
539
533 PANEL MOUNTING CLIP A 30mm square hole isrequired.Clip will accommodate metalthickness from 20SWG to16SWG (1.0mm - 1.5mm).Suits all 500 Series and 600Designer Series modules.
533
Page 32
567S SHORT WORKTOP MOUNTING BLOCKSize: 103mm x 51mm x 30mm.80mm product mountingcentres.4 x 16mm knockouts,4 x TPS cable knockouts.Suits Cat 588VH, 589VH,598F and 598FN.
567L LONG WORKTOP MOUNTINGBLOCKSize: 173mm x 51mm x 30mm.150mm product mountingcentres.8 x 16mm knockouts,8 x TPS cable knockouts.Suits Cat 597, 597N, 599Fand 599FN.
567L
574E SURFACE MOUNTINGENCLOSUREEnclosure suitable for usewith any 500 Series and 600Designer Series mechanism.
574E
538 CONVERSION PLATEPlate: 118mm x 118mm.Mounting centres (plate tobox): 84mm x 46mm.Plate mounting centres:84mm.
Note: Plate adapts existing 2 gang installation to 500 Series standard platesize.
CONVERSION PLATE
538
144PT FLUSH BOX Plastic threaded plate fixing holes.84mm x 52mm opening.84mm product mounting centres,48mm deep.Large cable entries for ease ofwiring.Side mounting by nails.Provision for horizontal or verticalmounting to studs.Provision for angled screw fixingthrough side wall.
144MT FLUSH BOX As for 144PT but with threadedbrass plate fixing holes.
FLUSH BOXES
144PT
560 SINGLE ARCHITRAVEMOUNTING BLOCKSize: 79mm x 33mm x 25mm deep.62mm product mountingcentres.4 x 16mm knockouts,4 x TPS cable knockouts.Suits Cat 561VH and 562VHArchitrave Plates.
565 DOUBLE ARCHITRAVEMOUNTING BLOCKSize: 132mm x 33mm x 25mm deep.2 mounting holes.114mm product mountingcentres.8 x 16mm knockouts,8 x TPS cable knockouts.Suits Cat 563VH and564VH Architrave Plates.565
560
567S
MOUNTING BLOCKS & SPACERS Cont . . .
544J JUNCTION BOXSize: 65mm x 92mm x 45mm deep.Rated at 40A, 500V.Includes 3 single and 1double screw terminals, fullyshrouded. Each terminalaccommodates 3 x 6mm2 cables.Comes with two ready-fixnails in the base.
544JUNCTION BOXSize: 67mm x 67mm x 37mm deep.Rated at 32A, 500V.4 mounting holes 51mm x51mm.Includes 4x 501T terminals,fully shrouded.Each terminalaccommodates 4 x 2.5mm2 cables.
544J
535 POWER TOWERSize: 158mm x 158mm x 140mm high.Takes 4 x standard, vertical 500 Series or 600 DesignerSeries plates.Fitted with divider forsegregated services.1 central 25mm conduitentry and 4 x 25mmknockouts.Cover has aperture for 500Series module.
POWER TOWER
535
500C SCREW CAPSuits all 500 Series screwfixing holes.
SCREW CAP
500C
501TSINGLE SCREW TERMINAL 32A5.5mm diameter hole.
501JARSINGLE SCREW TERMINALS32A, BULKJar of 100 single screwterminals (32A).5.5mm diameter hole.
501L1SINGLE SCREW TERMINAL 40ATerminal accepts 3 x 6mm2
conductors.
501L1/50SINGLE SCREW TERMINALS40A, BULKJar of 50 single screwterminals (40A).Terminals accept 3 x 6mm2
conductors.
501L2TWIN SCREW TERMINAL 40ATerminal accepts 3 x 6mm2
conductors.
501L2/40TWIN SCREW TERMINALS40A, BULKJar of 40 twin screw terminals(40A).Terminals accept 3 x 6mm2
conductors.
TERMINALS
JUNCTION BOXES
Page 33
FLOOR MOUNTED HOUSING
MISCELLANEOUS ACCESSORIES
501T
544501L1
501L2
Cat No. Page Cat No. Page Cat No. Page Cat No. Page89 ______________ 3189DP ____________ 3189SP ____________ 31144MT___________ 32144PT ___________ 32145V ____________ 30146H ____________ 30146V ____________ 30148H ____________ 30148V ____________ 30500B ____________ 17500BESP _________ 17500BSP __________ 17500BST __________ 17500C ____________ 33500ME___________ 15500TT ___________ 15501JAR __________ 33501L1 ___________ 33501L1/50_________ 33501L2 ___________ 33501L2/40_________ 33501T ____________ 33504VH/1 _________ 14509M____________ 19510ML12_________ 17510ML24_________ 17510MLD24 _______ 17510MN __________ 17511VH ___________ 20512VH/1 _________ 14513VH/1 _________ 14513VH/2 _________ 14514VH9/1 ________ 14514VH9/2 ________ 14514VH15/1 _______ 14514VH15/2 _______ 14514VH25/1 _______ 14514VH25/2 _______ 14515MS __________ 17516M____________ 18517M____________ 20518M____________ 20519M6___________ 20519M8___________ 20520 _____________ 9520K ____________ 9520M____________ 18521M____________ 18522 _____________ 9522LV ___________ 9523 _____________ 9524VH ___________ 20525 _____________ 10525X ____________ 10526KC ___________ 10526N ____________ 10527P ____________ 19
528 _____________ 28528M____________ 19528MI ___________ 19529M____________ 19530 _____________ 31531 _____________ 31532 _____________ 11533 _____________ 31534B8 ___________ 29534B16 __________ 29534B24 __________ 29534P8S __________ 29534P16S _________ 29534P24S _________ 29535 _____________ 33536 _____________ 31537 _____________ 31538 _____________ 32539 _____________ 31540 _____________ 19541M____________ 19542M____________ 19544 _____________ 33544J ____________ 33545 _____________ 8545N ____________ 8546 _____________ 11546R24 __________ 11547 _____________ 8547N ____________ 8548BS ___________ 12550VH ___________ 13550VHT __________ 13551 _____________ 8551M2___________ 18551VWP _________ 8556 _____________ 10557 _____________ 31558 _____________ 30559 _____________ 30560 _____________ 32561VH ___________ 13562VH ___________ 13563VH ___________ 13564VH ___________ 13565 _____________ 32566MNCB ________ 16567L ____________ 32567S ____________ 32568 _____________ 11568OFF __________ 11568ON___________ 11570R ____________ 27570R/15 _________ 27570S ____________ 27570S/15 _________ 27571 _____________ 12571R ____________ 14
572 _____________ 12573 _____________ 12573MM __________ 18573N ____________ 12573R ____________ 14574 _____________ 12574D32 __________ 12574E ____________ 32575 _____________ 28575MB __________ 21575VRCD ________ 21576 _____________ 26578M16__________ 15579 _____________ 8579/2____________ 8579H ____________ 8579H/2 __________ 8580D ____________ 12580M16N ________ 16580M16NPS ______ 18580M20HWS______ 16581 _____________ 7581HWP _________ 7581M16__________ 15581M16A/M ______ 16581M16B ________ 16581M16F_________ 16581M16FG _______ 16581M16F/R _______ 16581M16H ________ 16581M16HFL ______ 16581M16I/O _______ 16581M16L_________ 16581M16MW ______ 16581M16P ________ 16581M16PBM ______ 17581M16PBP ______ 17581M16PBS ______ 17581M16PS _______ 18581M16R ________ 16581M16SE _______ 16581M16S/W ______ 16581M16TV _______ 16581M16WH_______ 16581M16WT _______ 16581VH ___________ 13581VWP _________ 7582 _____________ 7582HWP _________ 8582VH ___________ 13582VWP _________ 7583 _____________ 7583VH ___________ 13584VH ___________ 13586VH ___________ 13587M10__________ 16588VH ___________ 13589VH ___________ 13
591CP ___________ 21591F ____________ 23591F/15__________ 23591FN ___________ 23591FP ___________ 23591FR ___________ 23591FRCD_________ 21591FX ___________ 23591FXN __________ 23592F ____________ 23592F/15__________ 24592FN ___________ 23592FP ___________ 24592FR ___________ 24592FX ___________ 24592FXN __________ 24593 _____________ 27593LRP __________ 28594F ____________ 25594F/15__________ 25594FN ___________ 25594FP ___________ 25594FR ___________ 25594FX ___________ 25594FXN __________ 25595F ____________ 25595F/15__________ 26595FN ___________ 25595FP ___________ 26595FR ___________ 26595FX ___________ 26595FXN __________ 26595L ____________ 26595LN ___________ 26595LX ___________ 26595LXN __________ 26596RCD__________ 22596/56RCD _______ 22597 _____________ 27597N ____________ 27598F ____________ 27598FN ___________ 27599F ____________ 27599FN ___________ 27615MBB _________ 19615MF___________ 18615MRB _________ 19615MST _________ 19617M2___________ 20680M32__________ 15680S ____________ 15687M3___________ 17687M4___________ 171575 ____________ 281588M___________ 16
INDEX BY CATALOGUE NUMBER
Page 34
WIRING DIAGRAMS
Page 35
A/P (Red)
1
L
C N
Load
A/P (Red)
1
L
C N
Load
2
578M16 Intermediate Switch
580M16N & 580M16NPS one way switches with neon
Neon permanently ON Neon ON, switch OFF (locator) Neon ON, switch ON (indicator)
Neon wires Neon wires Neon wires
Rear view of switch modules
Rear view of switch modules
N (Black)
LOAD
A/P (Red)
581M16 2 way switch 578M16 intermediate switch 581M16 2 way switch
Any number of intermediate switches can be wired between the 2 way switches
528M TV Antenna Socket & 529M FM Antenna Socket
8mm
Braid rolled back
Stripping guide actual size
2
3
528M/529M module
FM
5mm
Braid rolled back
Stripping guide actual size
TV
1
2
3
509M module
2
A/P (Red)
1
L
C N
Load
2
1
L
C
2
1
L
C
3
12
4
517M Master & 518M Secondary BT Telephone Sockets
509M TV-FM Splitter Antenna Socket
15mm
1
Coaxial cable
10mmCoaxial cable
50mm
517M or 518M module
Red
Blue
White
Use 500TT tool to insert wires (Ø 0.4mm)to IDC terminals, max two wires per terminal.
21 3
56 4
TECHNICAL DATA
Page 36
WIRING DIAGRAMS
Blue wireE (Green)
520K Dimmer Two way circuit
Loop2
1
C
581M16
2
1
C
581M16
Loop2
1
C
581M16
White wireBrown wire
White wireBrown wire
Lamp
Lamp
A/P (Red)
A/P (Red)
N (Black)
N (Black)
520K Dimmer One way circuit
520 Dimmer & 520M Dimmer Module Two way circuit
2
1
C
581M16
Loop2
1
C
581M16
Lamp Lamp
A/P (Red)
N (Black)
520KDimmer
Lamp
Lamp520KDimmer
Loop2
1
C
581M16
Lamp LampA/P (Red)
N (Black)
520 Dimmer & 520M Dimmer Module One way circuit
A/P (Red)
N (Black)
522 Dimmer & 523 Dimmer Remote
523Loop
A/P
Lamp
Remote
Loop
A/P
Lamp
Remote
522
Lamp Lamp
A/P (Red)
N (Black)
522LV Dimmer & 523 Dimmer Remote
523Loop
A/P
TX/Lamp
Remote
Loop
A/P
Lamp
Remote
522LV
12 VoltLamp
Fuse
12 VoltLamp
Blue wireE (Green)
White wire
White wire
520MDimmer Module
White wire
White wire
520MDimmer Module
LVTransformer
Fuse
Note: Transformer must be wire-wound,not electronic type.
Page 37
WIRING DIAGRAMS
R A/P LN
Cat 546
L =A/P =
R =N =
LoadActiveRemoteNeutral
Remote springreturn switch
R A/P LN
Cat 546
Cat 546R24
L =A/P =
R =N =
LoadActiveRemoteNeutral
R A/P LN
Cat 546
L =A/P =
R =N =
LoadActiveRemoteNeutral
Remoteswitch
Lamp
Time Delay Module
Blue wire
Orange wire
Brown wire
A/P (Red)
532 Time Delay Module
Fan532
Loop2
1
C
581M16
N (Black)
2
1
C
581M16
2
1
C
581M16P
A/P (Red)
N (Black)
A/P (Red)
N (Black)
A/P (Red)
N (Black)A/P (Red)
N (Black)
546 Timer Delay after switch off of a remote switch (D2 setup)
546 Timer
546R24 Timer
Delay after press of the timer button OR remote press switch (D1 setup)
Load ON when tappets down 546 Timer Delay after press of the timer button (D1 setup)
525 / 525X Fan Speed Control Reversing (only for four wire motors)
2
1
C
581M16
525
A N L+
N (Black)
2
1
C
525X
A N L+
N (Black)
2
1
C
Forwardwire
Reversewire
LoopLoop
A/P (Red) A/P (Red)
E (Green) E (Green) 581M16 581M16
LOAD
LOAD
LOAD
1
4
2
3
5
LOAD
Page 38
WIRING DIAGRAMS
A/PA/P (Red)
NN (Black) N OUT
E (Green)A/POUT
LINE IN
591RCD
AdditionalSocketOutlet
N
A/P
591FRCD
596RCD
556
N (Black)
Single 556 PIR Sensor
AA N N
Load
Supply
A/P (Red)
Lamp/s
556
N (Black)
Multiple 556 PIR Sensors
AA N N
Load
Supply Lamp/s
556
AA N N
Load
Supply
A/P (Red)
N (Black)
A/P
E (Green)
LINE
596RCD
SocketOutlet
N
A/PA/P (Red) N
A/P LOAD N
E
N
A/P
E
SocketOutlet
PDL INDUSTRIES LTDManufacturers of Electrical Products
Continuous quality is quality you
Head Office: PO Box 1367, Christchurch, New ZeaTelephone 03-338 9059, Fax 03-338
Auckland: Tel 09-525 6593, Fax 09-525 Wellington: Tel 04-589 1094, Fax 04-589 Official Carrier
registered to ISO 9002.
PDL Electrical Accessories are designed and engineered to ISO 9001and manufactured to ISO 9002.
500S-NZ-9/97
For 60 years the PDL Group ofCompanies has built an enviable inter-
national reputation founded on theconcept that “continuous quality is
quality you trust”.
PDL is globally recognised for manu-facturing the very best in electrical
accessories, industrial switchgear, ACvariable speed drives, custom plastic
products and electrical consumerappliances to the highest internationalstandards. PDL products are now dis-tributed to over 40 countries including
New Zealand, Australia, the UnitedKingdom, Europe, Asia, North
America, the Pacific and the MiddleEast.
Continuous investment in researchand development has provided thePDL Group with some of the most
sophisticated world-wide technologyand this, together with innovation,design excellence and independent
third-party quality assuranceschemes, has ensured PDL an excel-
lent reputation in the internationalmarket.
The commitment to R&D has under-pinned the current success of PDLHoldings’ ten subsidiary companiesand their continued further growth.Currently, the Group employs 2,100
people over three continents –Australasia, Asia and Europe and has
an annual turnover in excess of$NZ380 million.
THE PDL GROUP OF COMPANIES
PDL GROUP PRODUCTSPDL electrical wiring accessories for domestic, commercial and industrial applications.
Microdrive-3, Microdrive-i and Microdrive-Elite electronic variable speed
AC motor drives, Nu-Start soft starters for AC motors, Microvector AC motor speed controller
for high performance applications.
Specialist plastic custom moulding, blow moulded bottles, packs and closures for all sectors
of the packaging industry.
• DPRO - Air Circuit Breakers • CFS - Fuse Switch Units.
• Current Transformers • Power Analysers.
• Megatiker - Moulded Case Circuit Breakers • Various Fusegear.
PDL HOLDINGS LTD – THE GROUP
NATIONALACCREDITATION
OF CERTIFICATIONBODIES
ISO 9002CERT NO. 11595
QU
ALIT
Y
ASSESSED
PDL Industries Limited,Telarc Reg. No. 061registered to ISO 9002.
REGISTEREDSUPPLIER