Unrestricted © Siemens AG Österreich 2016. All rights reserved. siemens.com
SICAM RTUs– Ready for the FutureReinhard Krug, RC-AT EM DG PRO LM
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 2 Reinhard Krug
• Overview
• SICAM A8000 Series
• SICAM Engineering
• SICAM AK3
SICAM RTUs News
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 3 Reinhard Krug
• Overview
• SICAM A8000 Series
• SICAM Engineering
• SICAM AK 3
SICAM RTUs News
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 5 Reinhard Krug
• Overview
• SICAM A8000 Series
• SICAM Engineering
• SICAM AK3
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 7 Reinhard Krug
Great benefits right from the factory:Well-designed for practical use
Extended temperature range of -40°C to +70°Cfor rough ambient conditions
Highest EMC stability up to 5 kV (IEC 60255)for direct use in substations
Integrated short-circuit indicator functionalityfor use in cable network monitoring
Use of international standards such as IEC 61850for high investment security
Integrated crypto chip and IPSec encryptionto fulfill the high cyber security requirements
Multitude of interfaces and integratedGPRS module for simple adaptation toexisting communication infrastructures
Integrated web parameterization toolfor simple engineering
Plug-and-Play functionality of the modulesfor time and cost savings
Platform modularity for versatile applicationoptions and reduced inventory1.
2.
3.
4.
5.
6.
7.
8.
9.
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 8 Reinhard Krug
Module by module:Precisely tailored to the application
• Distribution grid automation andmicro-grids
• Optimized for use in MV switchgear• Load-flow control
• Grid connection for solar andwind farms
• Control and monitoring of electricityand gas distribution stations
• Simple gateway function
• Power distribution and transmission,micro-grids
• Railway power supply• Communication gateway
Space-saving dimensioningwith slim CP module
Everything in view withthe compact solution on site
With additional interfacesfor complex tasks
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 9 Reinhard Krug
A strong team:Equipped for any task
CP-8000 CP-8021 CP-8022 I/O module
Processor with integratedpower supply and display
Processor withexternal power supply
Expansion modulescombinable as needed
+//
Processor + GPRS withexternal power supply
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 10 Reinhard Krug
A strong team:Simple to install
• Compact DIN rail mounting
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 11 Reinhard Krug
A strong team:Simple to install
• Compact DIN rail mounting
• Consistent bus for I/O modules
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 12 Reinhard Krug
A strong team:Simple to install
• Compact DIN rail mounting
• Consistent bus for I/O modules
• Individual combination of modules
• Detection of the plugged modulesduring startup
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 13 Reinhard Krug
Cyber Security:Meeting the requirements of tomorrow
Compliant withBDEW White Paper
fulfills the recommendationsfor secure and reliablecontrol and communicationsystems
Password-protectedaccess toSICAM TOOLBOX II
ensures that only authorizedpersons can access yoursystem
Integrated crypto chip
protects credentials in a secureenvironment
Encryption andauthentication
with IPSec to remote sitewith https to engineering tool
Security event logging
SYSLOG messages
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 14 Reinhard Krug
IPSec Configuration
https
IEC 60870-5-104 Tunnel 1 Tunnel 2
IEC 61850
Back-up
Router Router Router Router
encrypted
unencrypted
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 15 Reinhard Krug
The entire family at a glance:Power supply units and processor modules
• 12 DI, 8 DO integrated, max. 116 I/O(max. 6 expansion modules)
• Maximum of 4 interfaces• Integrated function keys and display
Integrated power supply
SICAM CP-8000
• Maximum of 128 I/O(max. 8 expansion modules)
• Maximum of 4 interfaces
SICAM PS-8620, PS-8622
SICAM CP-8021
• Maximum of 128 I/O(max. 8 expansion modules)
• Maximum of 5 interfaces• Integrated GPRS modem
SICAM PS-8620, PS-8622
SICAM CP-8022
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 16 Reinhard Krug
The entire family at a glance:Expansion modules
DO-8212
8 binary outputsDC 24/48/60/110/220 V;AC 110/230 V
Integration offunctionalityof SICAM FCM
CM-8820
3 inputs currentI: 1 A/5 A (parameterizable)Output: 225 mV in accor-dance with IEC 60044-8
AI-8320
4 analog inputs-20…0…+20 mA-10…0…+10 V
AO-8380
4 analog outputs-20…0…+20 mA-10…0…+10 mA-10…0…+10 V
AI-8510
AI-8511
3 inputs current/voltage
I: 225 mV as per IEC 60044-8U: 100/√3 VAC, 230 VAC, 400/√3 VAC
I: 225 mV as per IEC 60044-8U: 3.25/√3 VAC
DI-8110DI-8111DI-8112DI-8113
16 binaryinputs
DC 24V
DC 48/60V
DC 110V
DC 220V
AI-8510
AI-8511
CM-8820
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 17 Reinhard Krug
• Overview
• SICAM A8000 Series
• SICAM Engineering
• SICAM AK 3
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 18 Reinhard Krug
Convenient engineering:Parameterization, commissioning and operation
with SICAM WEB with SICAM TOOLBOX II
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 19 Reinhard Krug
SICAM WEB:Parameterization made easy – with the online tool for SICAM A8000
• Display and download ofevent and alarm lists
• intuitive diagnostics• enhanced simulation and testing
New functions
• Plug & play functionality• Simple and intuitive user interface• Multilingual support• Universal use on tablets and desktop PCs• Optimized for small bandwidth• Reliable and secure remote maintenance
via https
Technical highlights • Access to all parameters 24/7• One-time assignment
of address• No limitation of applicability• Maximized user friendliness
Advantages
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 20 Reinhard Krug
SICAM TOOLBOX II:All automation tasks – an integrated tool
• New Operations Systems• Windows Server 2012 R2• Windows 8.1, Windows 10• Security Patches• SICAM WEB online diagnoses integrated• IEC 61850 Ed2 support
New functions V6.0
• Central database• Single data entry• Logging and simulation of telegrams• Local and remote functions• Supports current and legacy products• Supports newest SICAM A8000 Series
Proven advantages• Minimized effort for initial
data generation• Streamlined, efficient
engineering
Result
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 21 Reinhard Krug
• Overview
• SICAM A800 Series
• SICAM Engineering
• SICAM AK 3
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 22 Reinhard Krug
Proven SICAM system concept & functionality
Numerous communication protocols from different manufacturers
Open system architecture Simple process interfacing
Easy object-orientated
engineeringSICAM TOOLBOX II
application programs according to IEC 61131-3
Redundancy
Safety-related features
Security functionsPlug & play for spare parts
Compatibility to the system family SICAM RTUs
IEC 61850 IEC 60870-5-104IEC 60870-5-101
IEC 60870-5-103
Front End, Gateway
Process Control Applications, Automation Applications
Station Control Device,
Sub-Node
Telecontrol Substation
Ax 1703 Peripheral Bus Point-To-Point Traffic
multi-point trafficDial-Up Traffic
Absolutely free addressingMODBUSDNP3
· PROFIBUS-DP
NTP
SNMP
http/https (SSL)
Remote maintenance
IPSEC
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 23 Reinhard Krug
SICAM AK 3 – Overview
New racks
Integrated onboard Ethernetinterfaces at CPU-Module
New power supply
Single front panelsper board
Proven flexibleSICAM RTUs architecture
TBII integration
SICAM safety SIL2(safety integrity level)
SICAM Toolbox IIuntil Version 5.0
re-use ofCAEX plus logics
Plug&Playwith SD-Card
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 24 Reinhard Krug
SICAM AK3
New
Features
SecuritiyFeatures
§ Secure and authenticated communication
§ with IPSec to a remote site
§ with https to SICAM TOOLBOX II
§ Security events logging with SYSLOG
§ enhanced device monitoring with SNMPV3
§ User/role management and access password
§ credential storage on crypto chip
New
Feat
ures
Secu
rity
Feat
ures
Ben
efits
§ seamless Ethernet redundancy with parallel redundancyprotocol PRP acc. to IEC 62439-3
§ IEC 61850 Ed 2 Client, Server and GOOSE
§ enhanced performance of local interfaces
§ CPU redundancy in one rack CM-2848
§ improved rack for serial comm. gateways CM-2847
§ Simplified mechanical design
§ improved power supply
§ High performance RTU and
§ protocol gateway
§ Enhanced PLC capabilities
§ Superior I/O capabilities
Unrestricted © Siemens AG Österreich 2016. All rights reserved.June 16, 2016Page 25 Reinhard Krug
Reinhard KrugEM DG PRO LM
Ruthnergasse 31210 Vienna
Mobile: +43 (0) 664 80117 31275E-mail: [email protected]
siemens.at/future-of-energy