1
RYMSA RF will reserve the right to make any changes without notice. E-mail: [email protected] Web: www.rymsarf.com FLDV-006 UHF DTV 6 poles bandpass filter 50 W Filter type Bandpass coaxial Order (1) 6 with internal feedback Cavity size 50 mm Frequency range 470-862 MHz Mask type Non critical Impedance 50 Ohm Channel bandwidth 6, 7, 8 MHz Maximum RMS power handling 50 W Connectors N (F) Thermal stability 2 kHz / ºC Dimensions (W x D x H) 139 x 187 x 184 mm Temperature range -10°C to +50°C Working position Any Channel bandwidth 8 MHz (typical DVB-T/T2) Insertion loss f 0 1.0 dB Insertion loss f 0 3.8 MHz 3.1 dB Attenuations: f 0 4.2 MHz > 8 dB f 0 6 MHz > 25 dB f 0 12 MHz > 40 dB VSWR f 0 3.8 MHz 1.15:1 Group delay f 0 3.8 MHz < 200 ns Channel bandwidth 6 MHz (typical ISDB-T) Insertion loss f 0 1.2 dB Insertion loss f 0 2.79 MHz 3.3 dB Attenuations: f 0 3.15 MHz > 6 dB f 0 4.5 MHz > 25 dB f 0 9 MHz > 40 dB VSWR f 0 2.79 MHz 1.15:1 Group delay f 0 2.79 MHz < 250 ns Channel bandwidth 6 MHz (typical ATSC) Insertion loss f 0 1.2 dB Insertion loss f 0 2.69 MHz 3.0 dB Attenuations: f 0 3.15 MHz > 6 dB f 0 6.0 MHz > 20 dB f 0 9 MHz > 35 dB VSWR f 0 2.69 MHz 1.15:1 Group delay f 0 2.69 MHz < 250 ns Electrical Specifications Mechanical & Environmental Specifications NOTES: (1):8 th order filter on request. (2): Other frequency responses can be supplied. Please, ask RYMSA RF. The filter can be field retuned to any frequency within specified band Optional accesories Directional couplers at input and output Responses (2) TV UHF

FLDV-006 f0 3.8 MHz 1.15:1 Group delay f0 3.8 MHz < 200 ns Channel bandwidth 6 MHz (typical ISDB-T) Insertion loss f0 ≤ 1.2 dB Insertion loss f0 2.79 MHz ≤ 3.3 dB

  • Upload
    lamtram

  • View
    225

  • Download
    4

Embed Size (px)

Citation preview

Page 1: FLDV-006 f0 3.8 MHz 1.15:1 Group delay f0 3.8 MHz < 200 ns Channel bandwidth 6 MHz (typical ISDB-T) Insertion loss f0 ≤ 1.2 dB Insertion loss f0 2.79 MHz ≤ 3.3 dB

RYMSA RF will reserve the right to make any changes without notice.

E-mail: [email protected] Web: www.rymsarf.com

FLDV-006

UHF DTV 6 poles bandpass filter ● 50 W Filter type Bandpass coaxial

Order (1) 6 with internal feedback

Cavity size 50 mm

Frequency range 470-862 MHz

Mask type Non critical

Impedance 50 Ohm

Channel bandwidth 6, 7, 8 MHz

Maximum RMS power handling 50 W

Connectors N (F)

Thermal stability 2 kHz / ºC

Dimensions (W x D x H) 139 x 187 x 184 mm Temperature range -10°C to +50°C Working position Any

Channel bandwidth 8 MHz (typical DVB-T/T2)

Insertion loss f0 ≤ 1.0 dB Insertion loss f0 3.8 MHz ≤ 3.1 dB Attenuations: f0 4.2 MHz > 8 dB f0 6 MHz > 25 dB f0 12 MHz > 40 dB VSWR f0 3.8 MHz 1.15:1 Group delay f0 3.8 MHz < 200 ns

Channel bandwidth 6 MHz (typical ISDB-T)

Insertion loss f0 ≤ 1.2 dB Insertion loss f0 2.79 MHz ≤ 3.3 dB Attenuations: f0 3.15 MHz > 6 dB f0 4.5 MHz > 25 dB f0 9 MHz > 40 dB VSWR f0 2.79 MHz 1.15:1 Group delay f0 2.79 MHz < 250 ns

Channel bandwidth 6 MHz (typical ATSC)

Insertion loss f0 ≤ 1.2 dB Insertion loss f0 2.69 MHz ≤ 3.0 dB Attenuations: f0 3.15 MHz > 6 dB f0 6.0 MHz > 20 dB f0 9 MHz > 35 dB VSWR f0 2.69 MHz 1.15:1 Group delay f0 2.69 MHz < 250 ns

Electrical Specifications

Mechanical & Environmental Specifications

NOTES: (1):8th order filter on request. (2): Other frequency responses can be supplied. Please, ask RYMSA RF.

The filter can be field retuned to any frequency within specified band

Optional accesories Directional couplers at input and output

Responses (2)

TV UHF