ELECTRICAL LABELING CODES AND STANDARDS HellermannTyton offers a series of label creation and printing systems which allow users to design, edit and print required labels for Industrial Control Panels. HellermannTyton’s labeling systems help meet the requirements for labeling outlined in the National Electrical Code (NEC 2014), American National Standards Institute (ANSI Z535.4 – 2011) and UL508A for Industrial Control Panels. These standards provide details and guidelines for the design, placement, durability and colors of needed labels. HellermannTyton’s labeling solutions include TagPrint ® Pro 3.0 labeling software, labels and thermal transfer printing systems. WARNING ! WARNING ! DANGER ! 596-00379 l 1.35” x 2.75” 596-00377 l 2.75” x 5.5” DANGER ! 596-00387 l 1.35” x 2.75” 596-00389 l 2.75” x 5.5” 558-00336 l 1” wide roll 558-00337 l 2” wide roll 558-00338 l 3” wide roll 558-00339 l 1” wide roll 558-00341 l 2” wide roll 558-00343 l 3” wide roll 558-00310 l 1” wide roll 558-00314 l 2” wide roll 558-00346 l 3” wide roll 558-00307 l 1” wide roll 558-00311 l 2” wide roll 558-00374 l 3” wide roll 558-00340 l 1” wide roll 558-00342 l 2” wide roll 558-00344 l 3” wide roll 558-00351 l 4” wide roll 558-00309 l 1” wide roll 558-00313 l 2” wide roll 558-00345 l 3” wide roll 558-00350 l 4” wide roll 558-00308 l 1” wide roll 558-00312 l 2” wide roll 558-00006 l 3” wide roll 558-00370 l 4” wide roll 558-00327 l 2” wide roll 558-00330 l 3” wide roll 558-00333 l 4” wide roll 558-00328 l 2” wide roll 558-00331 l 3” wide roll 558-00334 l 4” wide roll 596-00378 l 1.35” x 2.75” 596-00376 l 2.75” x 5.5” 596-00386 l 1.35” x 2.75” 596-00388 l 2.75” x 5.5” SOLID COLORED CONTINUOUS VINYL ROLLS BANDED CONTINUOUS COLORED SIGNAL PANEL VINYL ROLLS PRE-PRINTED SIGNAL WORD LABELS Labels below sold as shown. 596-00203 l 4” x 6” 596-00424 l 3” x 2” 596-00204 l 4” x 6” 596-00426 l 3” x 2” 596-00621 l 4” x 6” 596-00622 l 3” x 2” 596-00247 l 4” x 6” 596-00425 l 3” x 2” 596-00371 l 4” x 6” 596-00372 l 3” x 2” WARNING ! CAUTION ! DANGER ! GENERAL REQUIREMENTS UL 508A SECTION 52 UL 508A SECTION 52.4 INDUSTRIAL CONTROL PANELS UL 508A SECTION 67.4.1 RESET White Foam Button Label NFPA 79 2012: CHAPTER 16.3 UL 508A SECTION 67.2.1 NEC 110.16 NFPA 70E 2012: ARTICLE 130.5(C) WARNING ! ARC FLASH AND SHOCK HAZARD Appropriate Personal Protection Equipment Required Failure To Comply Can Result In Death Or Injury. Refer to NFPA 70E 596-00622 UV NEC 409.110 UL 508A SECTION 52.1 built with pride by Milwaukee, WI (800)537-1512 INDUSTRIAL CONTROL PANEL VOLTS: 120VAC AMPS:16 ᴑ:1 HZ: 60 SHORT CIRCUIT CURRENT10KA RMS SYMMETRICAL, 240 V MAXIMUM ESL JOB# 5555-0000-11 MFR. DATE: 2-21-14 DIAGRAM #1234567899 TYPE: 4X www.hellermann.tyton.com UL 508A SECTION 56.1 CAUTION ! TO REDUCE RISK OF FIRE, REPLACE FUSES ONLY WITH TYPE AND RATING AS LISTED BELOW: FUSE TB1-FU1 TB1FU1-5 TB1-FU6 TB1-FU7-10 TB2-FU1 TB2-FU2 TYPE/AMP TB1-FU1 TB1FU1-5 TB1-FU6 TB1-FU7-10 TB2-FU1 TB2-FU2 Use copper wire rated for 60 degrees C only. OSHA 1910.303(E) PR OR 001000427181 TYPE ARIA RATING 4, 4X, 12, 13 POLYESTER (FULL DOOR) WHEN PROVIDED WITH DRAIN/VENTILATOR 3, 3R, 3S - CAUTION - BONDING BETWEEN CONDUIT CONNECTIONS IS NOT AUTOMATIC AND MUST BE PROVIDED AS PART OF THE INSTALLATION SEE INSTALLATION INSTRUCTIONS FOR USE WITH INDUSTRIAL CONTROL EQUIPMENT IN ORDINARY LOCATIONS HellermannTyton 7930 N. Faulkner Rd. Milwaukee, WI (800) 537-1512 www.hellermann.tyton.com OSHA 1910.335(B)(1) UL 508A SECTIONS 55.1, 55.2 AND 55.3 DANGER ! Electrocution Hazard Serious injury can occur if proper precautions are not followed. NFPA 79 2012: CHAPTER 10.7.3 E M E R G E N C Y S T O P 553-50011 ShrinkTrak 553-50011 ShrinkTrak 553-50011 ShrinkTrak 553-50011 ShrinkTrak 553-50011 ShrinkTrak 553-50011 ShrinkTrak Self Laminating for Cables NFPA 79 – 2012: CHAPTER 13.1.1.10 NFPA 79 – 2012: CHAPTER 16.5.4 UL 508 SECTION 67.3.1 904PWS NFPA 79 2012: CHAPTER 13 ARTICLE 13.1.1.6 01 02 03 04 05 NEC 250.126(3) UL 508A SECTION 54.5 NEC 110.27(C) NEC 490.48(B)(2) WARNING ! TURN OFF POWER SUPPLY TO EQUIPMENT PRIOR TO WORKING INSIDE PANEL NEC 110.3(B) UL 508A SECTION 54.4 INSTALLATION GUIDELINES TORQUE VALUES WIRE RANGE (FOR REFERENCE ONLY) CONDUCTOR SIZING TO BE DETERMINED BY NEC AND LOCAL CODES 1. TORGUE ALL POWER LUGS TO 325 IN. LB. 2. TORGUE ALL FUSE BLOCKS TO 15 IN. LB. 3. TORGUE ALL NEGATIVE TAP BARS TO 35 IN. LB. 1. ALL POWER LUGS: 350MCM - #6 AWG 2. ALL FUSE BLOCKS: #6 - #14 AWG 3. ALL TAP BARS: #4 - #14 AWG HellermannTyton makes no claim or warranty regarding code compliance. The user is responsible to research all code requirements prior to installation of any labeling that can affect equipment or worker safety. Labels shown are not to scale and are representations only. www.hellermann.tyton.com NEC 110.16 ARC FLASH LABELS NFPA 70E – 2012: ARTICLE 130.5(C) EQUIPMENT LABELING Electrical equipment such as switchboards, switchgear, panel boards, industrial control panels, meter socket enclosures, and motor control centers, that are in other than dwelling units, and are likely to require examination, adjustment, servicing or maintenance shall be field or factory marked to warn qualified persons of potential electric arc flash. NEC 110.27(C) WARNING SIGNS Entrance to rooms and other guarded locations that contain exposed live parts shall be marked with conspicuous warning signs forbidding unqualified persons to enter. NEC 110.3(B) UL 508A SECTION 54.4 EXAMINATION, IDENTIFICATION, INSTALLATION AND USE OF EQUIPMENT The torque and fuse requirements can be labeled per NEC110.3(B) which states that listed or labeled equipment shall be installed and used in accordance with any instructions included in the listed labeling. Fuse ratings also fall under NEC409 for Short Circuit Current Rating (SCCR) where a panel’s overall short circuit current rating is important to passing inspection. Customers may require evidence of compliance with 110.3(B) and listing the fuse number and type will ensure that the SCCR rating does not change. NEC 250.126(3) MARKING If the terminal for the grounding conductor is not visible, the conductor entrance hole shall be marked with the word GREEN or GROUND, the letters G or GR, a grounding symbol, or otherwise identified with a distinctive green color. NEC 409.110, UL 508A SECTION 52.1 ENCLOSURES An industrial control panel shall be marked with the following information that is plainly visible after installation. 1) Manufacturer’s name or trademark or authorized designation. 2) Supply voltages, number of phases, and full load current for each incoming supply circuit. 3) If supplied by more than one power source, the panel shall be marked to indicate more than one disconnecting means is required to de-energize the equipment. 4) SCCR (Short Circuit Current Rating). 5) If intended as service equipment shall be marked as such. 6) Electrical wiring diagram or ID number of separate diagram. 7) Factory identification. 8) Enclosure type. NEC 490.48(B)(2) ISOLATING EQUIPMENT Permanent legible signs shall be installed at isolating equipment, warning against operation while carrying current, unless the equipment is interlocked so that it cannot be operated under load. NFPA 79 – 2012: CHAPTER 16.5.4 UL 508 SECTION 67.3.1 All control panel devices and components shall be plainly identified with the same designation as shown on the machine drawings or diagram(s). NFPA 79 – 2012: CHAPTER 13.1.1.10 Identification tags shall be readable, permanent, and identified for use in the physical environment. Industry standards for marking wires are printable heat shrink tubing or self-laminating labels. NFPA 79 – 2012: CHAPTER 13 ARTICLE 13.1.1.6 Terminals on terminal blocks shall be plainly identified to correspond to markings on the diagram. NFPA 79 – 2012: CHAPTER 10.7.3 Actuators of emergency stop devices shall be colored RED. The background immediately around pushbuttons and disconnect switch actuators used as emergency stop devices shall be colored YELLOW. NFPA 79 – 2012: CHAPTER 16.3 FUNCTIONAL IDENTIFICATION UL 508A SECTION 67.2.1 Control devices, visual indicators, and displays used in the operator machine interface shall be clearly and durably marked with regard to their function either on or adjacent to the unit. OSHA 1910.303(E) Electrical equipment may not be used unless the following markings have been placed on the equipment. The manufacturer’s name and trademark, other descriptive markings giving voltage, current, wattage or other ratings as necessary. OSHA 1910.335(B)(1) Safety signs, safety symbols, or accident prevention tags shall be used where necessary to warn employees about electrical hazards which may endanger them as required by 1919.145. UL 508A SECTION 52 GENERAL MARKINGS Follow all marking instructions as outlined in UL508A Second Edition, dated December 30, 2013 or later. UL 508A SECTION 52.4 Markings required to be placed on an industrial control panel as specified in notes (a) – (d) and note (f) of Table 52.1 shall be made by die stamping, silk-screening, or etching in metal or plastic or with an indelible ink on adhesive backed label stock and permanently attached to the industrial control panel by rivets, screws, or adhesive. UL 508A SECTION 54.5 Marking with the words, “Ground” or “Grounding”; with the letters, “G”, “GR”, “GRD”, “GND”, or “GRND”. UL 508A SECTION 55.1 Cautionary markings shall be located on a part that is not removable without impairing the operation or appearance of the equipment. UL 508A SECTION 55.2 A cautionary marking shall be prefixed with the word “CAUTION” or “WARNING” as applicable, in letters not less than 1/8” (3.2mm) high. The remaining letters of such marking, unless otherwise specified, shall not be less than 1/16 inch (1.6mm) high. UL 508A SECTION 55.3 A cautionary marking intended to instruct the operator shall be legible and visible to the operator during normal operation of the equipment. A marking that provides servicing instructions shall be legible and visible when such servicing is performed. UL 508A SECTION 56.1 FUSE HOLDER MARKINGS A branch circuit fuse holder that accepts a fuse having a rating larger than the maximum specified rating and all control panel circuit fuseholders shall be marked with the voltage and current rating of the replacement fuse. Fuse ratings also fall under NEC409 for Short Circuit Current Rating (SCCR) where a panel’s overall short circuit current rating is important to passing inspection. Customers may require evidence of compliance with 110.3(A) and listing the fuse number and type will ensure that the SCCR rating does not change. UL 508A SECTION 67.4.1 An enclosure that does not clearly contain electrical parts shall be marked “CAUTION” – High Voltage - _____V”, or with a black lightening flash on a yellow background within a black triangle, or equivalent marking. ANSI Z535.4 would allow changing the signal word CAUTION to DANGER which is ANSI/OSHA and NEC compliant. LITPANELPOSTER ©HellermannTyton 2014

CODES AND STANDARDS - Allied Electronics - … AND STANDARDS HellermannTyton offers a series of label creation and printing systems which allow users to design, edit and print required

Embed Size (px)

Citation preview

ELECTRICAL LABELINGC O D E S A N D S T A N D A R D SHellermannTyton offers a series of label creation and printing systems which allow users to design, edit and print required labels for Industrial Control Panels. HellermannTyton’s labeling systems help meet the requirements for labeling outlined in the National Electrical Code (NEC 2014), American National Standards Institute (ANSI Z535.4 – 2011) and UL508A for Industrial Control Panels. These standards provide details and guidelines for the design, placement, durability and colors of needed labels. HellermannTyton’s labeling solutions include TagPrint® Pro 3.0 labeling software, labels and thermal transfer printing systems.

WARNING!

WARNING!

DANGER!

596-00379 l 1.35” x 2.75”596-00377 l 2.75” x 5.5”

DANGER!

596-00387 l 1.35” x 2.75”596-00389 l 2.75” x 5.5”

558-00336 l 1” wide roll558-00337 l 2” wide roll558-00338 l 3” wide roll

558-00339 l 1” wide roll558-00341 l 2” wide roll558-00343 l 3” wide roll

558-00310 l 1” wide roll558-00314 l 2” wide roll558-00346 l 3” wide roll

558-00307 l 1” wide roll558-00311 l 2” wide roll558-00374 l 3” wide roll

558-00340 l 1” wide roll558-00342 l 2” wide roll558-00344 l 3” wide roll558-00351 l 4” wide roll

558-00309 l 1” wide roll558-00313 l 2” wide roll558-00345 l 3” wide roll558-00350 l 4” wide roll

558-00308 l 1” wide roll558-00312 l 2” wide roll558-00006 l 3” wide roll558-00370 l 4” wide roll

558-00327 l 2” wide roll558-00330 l 3” wide roll558-00333 l 4” wide roll

558-00328 l 2” wide roll558-00331 l 3” wide roll558-00334 l 4” wide roll

596-00378 l 1.35” x 2.75”596-00376 l 2.75” x 5.5”

596-00386 l 1.35” x 2.75”596-00388 l 2.75” x 5.5”

S O L I D C O L O R E D C O N T I N U O U S V I N Y L R O L L S B A N D E D C O N T I N U O U S C O L O R E D S I G N A L P A N E L V I N Y L R O L L S

P R E - P R I N T E D S I G N A L W O R D L A B E L S Labels below sold as shown.

596-00203 l 4” x 6”596-00424 l 3” x 2”

596-00204 l 4” x 6”596-00426 l 3” x 2”

596-00621 l 4” x 6”596-00622 l 3” x 2”

596-00247 l 4” x 6”596-00425 l 3” x 2”

596-00371 l 4” x 6”596-00372 l 3” x 2”

WARNING! CAUTION!DANGER!

GENERAL REQUIREMENTS UL 508A SECTION 52 UL 508A SECTION 52.4

I N D U S T R I A L C O N T R O L P A N E L S

UL 508A SECTION 67.4.1

RESET

White FoamButton Label

NFPA 79 – 2012: CHAPTER 16.3

UL 508A SECTION 67.2.1

NEC 110.16

NFPA 70E – 2012: ARTICLE 130.5(C)

WARNING!ARC FLASH AND SHOCK HAZARD

Appropriate Personal Protection Equipment Required

Failure To Comply Can Result In Death Or Injury. Refer to NFPA 70E

596-00622 UV

NEC 409.110 UL 508A SECTION 52.1

built with pride by

Milwaukee, WI(800)537-1512

INDUSTRIAL CONTROL PANELVOLTS: 120VAC AMPS:16 ᴑ:1 HZ: 60SHORT CIRCUIT CURRENT10KA RMS SYMMETRICAL, 240 V MAXIMUM

ESL JOB# 5555-0000-11MFR. DATE: 2-21-14DIAGRAM #1234567899

TYPE: 4Xwww.hellermann.tyton.com

UL 508A SECTION 56.1

CAUTION!TO REDUCE RISK OF FIRE, REPLACE FUSES

ONLY WITH TYPE AND RATING AS LISTED BELOW:

FUSETB1-FU1TB1FU1-5TB1-FU6TB1-FU7-10TB2-FU1TB2-FU2

TYPE/AMP TB1-FU1 TB1FU1-5 TB1-FU6 TB1-FU7-10 TB2-FU1 TB2-FU2

Use copper wire rated for 60 degrees C only.

OSHA 1910.303(E)

PR OR 001000427181

TYPE ARIARATING 4, 4X, 12, 13POLYESTER (FULL DOOR)

WHEN PROVIDED WITH DRAIN/VENTILATOR 3, 3R, 3S

- CAUTION - BONDING BETWEEN CONDUIT CONNECTIONS IS NOT AUTOMATIC

AND MUST BE PROVIDED AS PART OF THE INSTALLATIONSEE INSTALLATION INSTRUCTIONS

FOR USE WITH INDUSTRIAL CONTROL EQUIPMENT IN ORDINARY LOCATIONS

HellermannTyton7930 N. Faulkner Rd.

Milwaukee, WI (800) 537-1512

www.hellermann.tyton.com

OSHA 1910.335(B)(1)

UL 508A SECTIONS 55.1, 55.2 AND 55.3

DANGER!

Electrocution Hazard

Serious injury can occur if proper precautions are not followed.

NFPA 79 – 2012: CHAPTER 10.7.3

EM

ERGENCY

S T O P

553-50011ShrinkTrak

553-50011ShrinkTrak

553-50011ShrinkTrak

553-50011ShrinkTrak

553-50011ShrinkTrak

553-50011ShrinkTrak

Self Laminating for Cables

NFPA 79 – 2012: CHAPTER 13.1.1.10

NFPA 79 – 2012: CHAPTER 16.5.4

UL 508 SECTION 67.3.1

904PWS

NFPA 79 – 2012: CHAPTER 13 ARTICLE 13.1.1.6

0102030405

NEC 250.126(3)

UL 508A SECTION 54.5

NEC 110.27(C) NEC 490.48(B)(2)

WARNING!

TURN OFF POWER SUPPLY TO

EQUIPMENT PRIOR TO WORKING INSIDE PANEL

NEC 110.3(B) UL 508A SECTION 54.4

INSTALLATION GUIDELINESTORQUE VALUES

WIRE RANGE (FOR REFERENCE ONLY)

CONDUCTOR SIZING TO BE DETERMINED BY NEC AND LOCAL CODES

1. TORGUE ALL POWER LUGS TO 325 IN. LB.2. TORGUE ALL FUSE BLOCKS TO 15 IN. LB.3. TORGUE ALL NEGATIVE TAP BARS TO 35 IN. LB.

1. ALL POWER LUGS: 350MCM - #6 AWG2. ALL FUSE BLOCKS: #6 - #14 AWG3. ALL TAP BARS: #4 - #14 AWG

HellermannTyton makes no claim or warranty regarding code compliance. The user is responsible to research all code requirements prior to installation of any labeling that can affect equipment or worker safety. Labels shown are not to scale and are representations only.www.hellermann.tyton.com

NEC 110.16 ARC FLASH LABELS NFPA 70E – 2012: ARTICLE 130.5(C) EQUIPMENT LABELING Electrical equipment such as switchboards, switchgear, panel boards, industrial control panels, meter socket enclosures, and motor control centers, that are in other than dwelling units, and are likely to require examination, adjustment, servicing or maintenance shall be field or factory marked to warn qualified persons of potential electric arc flash. NEC 110.27(C) WARNING SIGNS Entrance to rooms and other guarded locations that contain exposed live parts shall be marked with conspicuous warning signs forbidding unqualified persons to enter.NEC 110.3(B) UL 508A SECTION 54.4 EXAMINATION, IDENTIFICATION, INSTALLATION AND USE OF EQUIPMENT The torque and fuse requirements can be labeled per NEC110.3(B) which states that listed or labeled equipment shall be installed and used in accordance with any instructions included in the listed labeling. Fuse ratings also fall under NEC409 for Short Circuit Current Rating (SCCR) where a panel’s overall short circuit current rating is important to passing inspection. Customers may require evidence of compliance with 110.3(B) and listing the fuse number and type will ensure that the SCCR rating does not change. NEC 250.126(3) MARKING If the terminal for the grounding conductor is not visible, the conductor entrance hole shall be marked with the word GREEN or GROUND, the letters G or GR, a grounding symbol, or otherwise identified with a distinctive green color. NEC 409.110, UL 508A SECTION 52.1 ENCLOSURES An industrial control panel shall be marked with the following information that is plainly visible after installation. 1) Manufacturer’s name or trademark or authorized designation. 2) Supply voltages, number of phases, and full load current for each incoming supply circuit. 3) If supplied by more than one power source, the panel shall be marked to indicate more than one disconnecting means is required to de-energize the equipment. 4) SCCR (Short Circuit Current Rating). 5) If intended as service equipment shall be marked as such. 6) Electrical wiring diagram or ID number of separate diagram. 7) Factory identification. 8) Enclosure type. NEC 490.48(B)(2) ISOLATING EQUIPMENT Permanent legible signs shall be installed at

isolating equipment, warning against operation while carrying current, unless the equipment is interlocked so that it cannot be operated under load. NFPA 79 – 2012: CHAPTER 16.5.4 UL 508 SECTION 67.3.1 All control panel devices and components shall be plainly identified with the same designation as shown on the machine drawings or diagram(s).NFPA 79 – 2012: CHAPTER 13.1.1.10 Identification tags shall be readable, permanent, and identified for use in the physical environment. Industry standards for marking wires are printable heat shrink tubing or self-laminating labels.NFPA 79 – 2012: CHAPTER 13 ARTICLE 13.1.1.6 Terminals on terminal blocks shall be plainly identified to correspond to markings on the diagram.NFPA 79 – 2012: CHAPTER 10.7.3 Actuators of emergency stop devices shall be colored RED. The background immediately around pushbuttons and disconnect switch actuators used as emergency stop devices shall be colored YELLOW.NFPA 79 – 2012: CHAPTER 16.3 FUNCTIONAL IDENTIFICATION UL 508A SECTION 67.2.1 Control devices, visual indicators, and displays used in the operator machine interface shall be clearly and durably marked with regard to their function either on or adjacent to the unit.OSHA 1910.303(E) Electrical equipment may not be used unless the following markings have been placed on the equipment. The manufacturer’s name and trademark, other descriptive markings giving voltage, current, wattage or other ratings as necessary.OSHA 1910.335(B)(1) Safety signs, safety symbols, or accident prevention tags shall be used where necessary to warn employees about electrical hazards which may endanger them as required by 1919.145.UL 508A SECTION 52 GENERAL MARKINGS Follow all marking instructions as outlined in UL508A Second Edition, dated December 30, 2013 or later.

UL 508A SECTION 52.4 Markings required to be placed on an industrial control panel as specified in notes (a) – (d) and note (f) of Table 52.1 shall be made by die stamping, silk-screening, or etching in metal or plastic or with an indelible ink on adhesive backed label stock and permanently attached to the industrial control panel by rivets, screws, or adhesive.UL 508A SECTION 54.5 Marking with the words, “Ground” or “Grounding”; with the letters, “G”, “GR”, “GRD”, “GND”, or “GRND”.UL 508A SECTION 55.1 Cautionary markings shall be located on a part that is not removable without impairing the operation or appearance of the equipment.UL 508A SECTION 55.2 A cautionary marking shall be prefixed with the word “CAUTION” or “WARNING” as applicable, in letters not less than 1/8” (3.2mm) high. The remaining letters of such marking, unless otherwise specified, shall not be less than 1/16 inch (1.6mm) high. UL 508A SECTION 55.3 A cautionary marking intended to instruct the operator shall be legible and visible to the operator during normal operation of the equipment. A marking that provides servicing instructions shall be legible and visible when such servicing is performed. UL 508A SECTION 56.1 FUSE HOLDER MARKINGS A branch circuit fuse holder that accepts a fuse having a rating larger than the maximum specified rating and all control panel circuit fuseholders shall be marked with the voltage and current rating of the replacement fuse. Fuse ratings also fall under NEC409 for Short Circuit Current Rating (SCCR) where a panel’s overall short circuit current rating is important to passing inspection. Customers may require evidence of compliance with 110.3(A) and listing the fuse number and type will ensure that the SCCR rating does not change. UL 508A SECTION 67.4.1 An enclosure that does not clearly contain electrical parts shall be marked “CAUTION” – High Voltage - _____V”, or with a black lightening flash on a yellow background within a black triangle, or equivalent marking. ANSI Z535.4 would allow changing the signal word CAUTION to DANGER which is ANSI/OSHA and NEC compliant.

LITPANELPOSTER ©HellermannTyton 2014