2
 48 Fiber Cable Shown PE Outer Jacket Steel Armor Steel RSM (2) Ripcord for Jacket Access (2) 6.0mm Buffer Tube Ripcord for Armor Access (2) Gel 250 micron Fibers Physical Specifications 002 - 024 5021 2 0.16(4.0) 0.43(11.0) 93(138) 8.6(22.0) 4.3(11.0) 607(2700) 180(800) 1945(593) 026 - 048 5021 4 0.24( 6.0) 0.51( 13.0) 121( 181) 10.2( 26.0) 5.1( 13.0) 607( 2700) 180( 800) 1483( 452) 050 - 096 5021 8 0.31( 8.0) 0.59( 15.0) 152( 226) 11.8( 30.0) 5.9( 15.0) 607( 2700) 180( 800) 1188( 362) 5021 Series cable is constructed with 12 fibers per tube Environmental and Mechanical Cable Identification Specification Test Method Operating Temperature -40° to 158° F (-40° to +70° C) FOTP - 3 Installation Temperature -22° to 14F (-30° to +60°C) N/A Storage Temperature -40° to 167° F (-40° to +75° C) N/A Crush Resistance 250lbf/in (44N/mm) FOTP - 41 1 - Blue 5 - Slate 9 - Yellow Impact Resistance Exceeds FOTP - 25 2 - Orange 6 - White 10 - Violet Flexing 25 Cycles FOTP - 104 3 - Green 7 - Red 11 - Rose Twist Bend Exceeds FOTP - 85 4 - Brown 8 - Black 12 - Aqua SYSTIMAX® Outside Plant Fiber Optic Cables are designed and qualified to the requirements of Telcordia GR-20-CORE, Issue 2; ANSI/ICEA S-87-640-1999 Standard for Optical Fiber Outside Plant Communications Cable; IEC 60793 Optical Fibers; IEC 60794 Optical Fiber C ables; and ITU-T G.652 Characteristics of a Singlemode Optical Fiber. Drawings not to scale Visit our Web site at w ww.systi max.com or contact your local SYSTIMAX Solutions Specifications subject to change representative or SYSTIMAX BusinessPartner for more information. Revision Date: 02/14/06 5021 Series SYSTIMAX® Armored Outdoor Cable Fiber Bundles and Fibers are identified with standard color coding: 2 - 96 Fiber Arid-Core® Construction Central Tube Short Te rm Long Ter m Bundles Catalog Number Cable Jacket - Black medium density polyethylene Fiber Count Maximum Vertical Rise Feet (Meters) Minimum Bend Radius in. (cm) Loaded Unloaded Weight lbs/kft (kg/km) Jacket Diameter in. (mm) Max. Tensile Load lbs. (Newtons) Buffer Tube Diameter in. (mm)

Pd 310327

Embed Size (px)

DESCRIPTION

Engineering

Citation preview

  • 48 Fiber Cable Shown

    PE Outer JacketSteel Armor

    Steel RSM (2)Ripcord for Jacket Access (2)

    6.0mm Buffer TubeRipcord for Armor Access (2)

    Gel250 micron Fibers

    Physical Specifications

    002 - 024 5021 2 0.16 (4.0) 0.43 (11.0) 93 (138) 8.6 (22.0) 4.3 (11.0) 607 (2700) 180 (800) 1945 (593)026 - 048 5021 4 0.24 (6.0) 0.51 (13.0) 121 (181) 10.2 (26.0) 5.1 (13.0) 607 (2700) 180 (800) 1483 (452)050 - 096 5021 8 0.31 (8.0) 0.59 (15.0) 152 (226) 11.8 (30.0) 5.9 (15.0) 607 (2700) 180 (800) 1188 (362)

    5021 Series cable is constructed with 12 fibers per tube

    Environmental and Mechanical Cable IdentificationSpecification Test Method

    Operating Temperature -40 to 158 F (-40 to +70 C) FOTP - 3Installation Temperature -22 to 140 F (-30 to +60C) N/AStorage Temperature -40 to 167 F (-40 to +75 C) N/ACrush Resistance 250lbf/in (44N/mm) FOTP - 41 1 - Blue 5 - Slate 9 - YellowImpact Resistance Exceeds FOTP - 25 2 - Orange 6 - White 10 - VioletFlexing 25 Cycles FOTP - 104 3 - Green 7 - Red 11 - RoseTwist Bend Exceeds FOTP - 85 4 - Brown 8 - Black 12 - Aqua

    SYSTIMAX Outside Plant Fiber Optic Cables are designed and qualified to the requirements ofTelcordia GR-20-CORE, Issue 2; ANSI/ICEA S-87-640-1999 Standard for Optical Fiber Outside Plant Communications Cable; IEC 60793 Optical Fibers; IEC 60794 Optical Fiber Cables; and ITU-T G.652Characteristics of a Singlemode Optical Fiber.

    Drawings not to scaleVisit our Web site at www.systimax.com or contact your local SYSTIMAX Solutions Specifications subject to change

    representative or SYSTIMAX BusinessPartner for more information. Revision Date: 02/14/06

    5021 Series

    SYSTIMAX Armored Outdoor Cable

    Fiber Bundles and Fibers are identified with standard color coding:

    2 - 96 Fiber Arid-Core ConstructionCentral Tube

    Short Term Long Term

    BundlesCatalog Number

    Cable Jacket - Black medium density polyethylene

    Fiber Count

    Maximum Vertical Rise Feet (Meters)

    Minimum Bend Radius in. (cm)

    Loaded Unloaded

    Weight lbs/kft

    (kg/km)

    Jacket Diameter in. (mm)

    Max. Tensile Load lbs. (Newtons)Buffer Tube

    Diameter in. (mm)