48 Fiber Cable Shown
PE Outer JacketSteel Armor
Steel RSM (2)Ripcord for Jacket Access (2)
6.0mm Buffer TubeRipcord for Armor Access (2)
Gel250 micron Fibers
Physical Specifications
002 - 024 5021 2 0.16 (4.0) 0.43 (11.0) 93 (138) 8.6 (22.0) 4.3 (11.0) 607 (2700) 180 (800) 1945 (593)026 - 048 5021 4 0.24 (6.0) 0.51 (13.0) 121 (181) 10.2 (26.0) 5.1 (13.0) 607 (2700) 180 (800) 1483 (452)050 - 096 5021 8 0.31 (8.0) 0.59 (15.0) 152 (226) 11.8 (30.0) 5.9 (15.0) 607 (2700) 180 (800) 1188 (362)
5021 Series cable is constructed with 12 fibers per tube
Environmental and Mechanical Cable IdentificationSpecification Test Method
Operating Temperature -40 to 158 F (-40 to +70 C) FOTP - 3Installation Temperature -22 to 140 F (-30 to +60C) N/AStorage Temperature -40 to 167 F (-40 to +75 C) N/ACrush Resistance 250lbf/in (44N/mm) FOTP - 41 1 - Blue 5 - Slate 9 - YellowImpact Resistance Exceeds FOTP - 25 2 - Orange 6 - White 10 - VioletFlexing 25 Cycles FOTP - 104 3 - Green 7 - Red 11 - RoseTwist Bend Exceeds FOTP - 85 4 - Brown 8 - Black 12 - Aqua
SYSTIMAX Outside Plant Fiber Optic Cables are designed and qualified to the requirements ofTelcordia GR-20-CORE, Issue 2; ANSI/ICEA S-87-640-1999 Standard for Optical Fiber Outside Plant Communications Cable; IEC 60793 Optical Fibers; IEC 60794 Optical Fiber Cables; and ITU-T G.652Characteristics of a Singlemode Optical Fiber.
Drawings not to scaleVisit our Web site at www.systimax.com or contact your local SYSTIMAX Solutions Specifications subject to change
representative or SYSTIMAX BusinessPartner for more information. Revision Date: 02/14/06
5021 Series
SYSTIMAX Armored Outdoor Cable
Fiber Bundles and Fibers are identified with standard color coding:
2 - 96 Fiber Arid-Core ConstructionCentral Tube
Short Term Long Term
BundlesCatalog Number
Cable Jacket - Black medium density polyethylene
Fiber Count
Maximum Vertical Rise Feet (Meters)
Minimum Bend Radius in. (cm)
Loaded Unloaded
Weight lbs/kft
(kg/km)
Jacket Diameter in. (mm)
Max. Tensile Load lbs. (Newtons)Buffer Tube
Diameter in. (mm)