PCV0915_tcm28-1674

Embed Size (px)

Citation preview

  • 8/12/2019 PCV0915_tcm28-1674

    1/36

  • 8/12/2019 PCV0915_tcm28-1674

    2/36

    21

    Latest individual air conditioning

    technology adds new real valueto today's buildings

    Air conditioning systems that use new refrigerant and save energy are the norm. However, we at Daikin

    have gone much further by maximising our advanced technology developed over 25 years as the

    leading manufacturer of individual air conditioning systems. Not only top level air conditioning

    performance, we also offer minimal space utilisation, efficient building management and a multitude of

    other added value features.

    Daikins VRV systems include indoor and

    outdoor units available in a wide range of

    models for various building sizes and

    installation conditions. Long refrigerant

    piping lengths and other features put few

    restrictions on design for great flexibility in

    meeting the needs of the building.

    Daikin offers a compact design for VRVIII outdoor units by

    further optimising equipment functions, exceeding the norm for

    air conditioning systems. Compact units facilitate installation in

    limited areas, such as rooftops, and take up less effective

    space. Easier installation work realises fast completion with timeto spare.

    Benefits for INSTALLERS

    With Daikin's proprietary inverter technology and cutting-edge

    control technology for refrigerant, the VRVIII air conditioning system

    operates with outstanding efficiency. This contributes to high energy

    savings, which greatly reduces your running costs and facilitates far

    better building management.

    Benefits for

    property OWNERS

    To provide a comfortable air

    environment, Daikin offers air

    treatment systems beyond mere air

    conditioning. As well as bringing air to

    a comfortable temperature, the airquality can be treated with ventilation,

    humidification, and other processes.

    Ease of use is realised through

    advanced, centralised control

    systems.

    Benefits for USERS

    Benefits for CONSULTANTand DESIGN OFFICES

  • 8/12/2019 PCV0915_tcm28-1674

    3/36

    43

    Outdoor units with large capacities................................................................page 7

    Wide range and an increased number of connectable indoor units......page 9

    High COPs/Energy savings

    Compliant with the RoHS Directive

    Extended level difference between outdoor units and indoor units.....page 10

    Extended actual and total maximum piping length...................................page 10

    High external static pressure..........................................................................page 11

    Two types of outdoor unit combinations.....................................................page 11

    Developed to facilitate more flexible system design

    inlarge-sized buildings

    Automatic test operation

    Less chances of refrigerant leakage

    Double backup operation in compressors and units

    Outdoor units designed for low operation

    Efficient compressor

    Easier installation.....................................................page12

    A sense of responsibility..........................................page13

    Enhanced comfort....................................................page14

    Nighttime quiet operation function

    Daikin proudly introduces the VRVIII series, which is well-suited to

    large-sized buildings. This air conditioning system provides outdoor

    units that extend air conditioning capacity up to 54 HP. It also

    incorporates numerous outstanding features, such as a wide range

    of outdoor and indoor units, longer actual and total piping length,

    and high external static pressure. The VRVIII series provides the

    power and versatility you need for flexible design and easy

    installation in large-sized buildings.

    Contents

    Technologies.................................. page 5

    Main Features................................ page 7

    Control Systems............................page 47Indoor Unit Lineup........................page 15

    Outdoor Unit Lineup.....................page 25

    Specifications................................ page 27

    Indoor units.....................................page 27

    Outdoor units..................................page 34

    Option List.......................................page 44

    Indoor units....................................page 44

    Outdoor units.................................page 46

    Air Treatment Equipment Lineup...page 58

    Outdoor-air processing unit...........page 59

    Heat Reclaim Ventilator withDX-coil and humidifier....................page 63

    Heat Reclaim Ventilator..................page 67

  • 8/12/2019 PCV0915_tcm28-1674

    4/36

  • 8/12/2019 PCV0915_tcm28-1674

    5/36

    Large capacities for large-sized buildings Large capacities for large-sized buildings

    Main Features

    87

    Daikins indoor unit system offers a large number of connectable indoor units64! Furthermore, our wide range ofindoor units includes 15 types and 73 models* to meet the needs of customers.

    Indoor units

    The previous outdoor unit had a maximum output of 48 HP. The VRVIII have a top output of54 HP! By connecting main units (up to 18 HP each), a high-capacity system (up to 54 HP)that is compact yet flexible can be achieved.

    By providing a range of horse powerlevels in 2 HP increments*, Daikinresponds flexibly to customer needs.

    * Refer to page 26 for combination details.

    Outdoor units

    48 HP 54 HP

    Ceiling MountedCassette(Round Flow)

    Type Model Name Capacity Range

    Capacity Index 20

    0.8 HP

    40

    1.6 HP

    62.5

    2.5 HP

    80

    3.2 HP

    100

    4 HP

    125

    5 HP

    140

    6 HP

    200

    8 HP

    250

    10 HP

    50

    2 HP

    31.25

    1.25 HP

    25

    1 HP

    20 40 63 80 100 125 140 200 250503225

    Ceiling MountedCassette(Double Flow)

    FXCQ-MVE

    Ceiling MountedCassette(Compact Multi Flow)

    FXZQ-MVE

    Slim Ceiling

    Mounted Duct

    Ceiling Mounted

    Duct

    Ceiling Suspended

    Wall Mounted

    Floor Standing

    Concealed

    Floor Standing

    Ceiling MountedCassette Corner

    FXDQ-NBVE(with drain pump)

    FXDQ-NBVET(without drain pump)

    FXMQ-PVE

    FXMQ-MAVE

    FXHQ-MAVE

    FXAQ-MAVE

    FXLQ-MAVE

    FXNQ-MAVE

    FXKQ-MAVE

    FXDQ-PBVET(without drain pump)

    FXDQ-PBVE

    (with drain pump)

    (900/1,100 mm width type)

    (700 mm width type)

    R-410A VRV system indoor units are not compatible with the R-22 VRV system.Note:

    2 HP increments

    Offering a higher capacity of up to 54 HP,

    responding to the needs of large-sized buildings

    * Except for 5 HP 30, 32, 34, 36 HP

    38, 40, 42, 44, 46 HP 48, 50, 52, 54 HP

    5 HP 8, 10 HP 12, 14, 16, 18 HP

    20, 22, 24, 26, 28 HP

    VRVIIMA series

    New

    The latest technology is implemented in the VRVIII system. Surpassing even the VRVII, the VRVIII responds to

    more of the needs of our customers that require air-conditioning solutions for large-sized buildings.

    Major advances of theVRVIII over the VRVII for large-sized buildings

    BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data for details.Note:

    Connection unit series indoor units (50 Hz only)

    * 14 types and 70 models for 60 Hz specifications.

    Ceiling Suspended

    Cassette

    Type Model Name

    1.6 HP0.8 HP 1.25 HP1 HP

    FXUQ-MAV1

    20 4031.2525

    BEVQ125MAVE

    5 HP

    BEVQ100MAVEBEVQ71MAVE

    2 HP 4 HP3 HP

    50 12510071

    Capacity Range

    4020 3225 12550 10071

    Connection Unit

    Capacity Index

    FXFQ-PVE

    New New New New New

    New

  • 8/12/2019 PCV0915_tcm28-1674

    6/36

  • 8/12/2019 PCV0915_tcm28-1674

    7/36

    Large capacities for large-sized buildings

    Main Features

    Easier installation

    Automatic test operation

    Simply press the test operation button and the unit performs an automatic system check, including wiring,shutoff valves, and sensors. The results are returned automatically after the check finishes.

    High external static pressure 78.4 Pa (8 mm H2O)

    58.8Pa 78.4Pa

    Approx.

    33.3%increase!

    Selectable from two types of combinations

    Normal type (Space saving type)

    High-COP type (Energy saving type)

    8

    10

    12

    14

    16

    18

    8

    1

    5

    5

    1

    22

    2

    24

    2

    26

    2

    10

    1

    12

    1

    16

    1

    14

    1

    20

    2

    18

    1

    Total number

    of connected

    outdoor units

    HP

    Single unit

    Single outdoor units Double outdoor units Double outdoor units

    * Refer to page 26 for outdoor combination details.

    38

    3

    42

    3

    40

    3

    44

    3

    46

    3

    48

    3

    50

    3

    52

    3

    54

    3

    Triple outdoor units

    * Refer to page 26 for outdoor combination details.

    8

    10

    12

    14

    16

    18

    18

    2

    16

    2

    36

    3

    38

    3

    24

    3

    26

    3

    30

    3

    28

    3

    34

    3

    32

    3

    Total number

    of connected

    outdoor units

    HP

    Single unit

    Double outdoor units Triple outdoor units

    40

    3

    42

    3

    46

    3

    44

    3

    50

    3

    48

    3

    Triple outdoor units

    28

    2

    30

    2

    34

    2

    36

    2

    32

    2

    Higher external static pressure has been achieved thanks to the fan grilles and thedual DC fans that reduce internal pressure loss. Exceeding the previous 58.8 Pa (6mm H2O) level, Daikin now offers 78.4 Pa(8 mm H2O) external static pressure by

    field setting to meet the requirements forinstallation on each floor, often requestedfor large-sized buildings.

    VRVII

    MA series

    1211

    78.4Pa

  • 8/12/2019 PCV0915_tcm28-1674

    8/36

  • 8/12/2019 PCV0915_tcm28-1674

    9/36

  • 8/12/2019 PCV0915_tcm28-1674

    10/36

    Indoor Unit Lineup

    1817

    Ceiling Mounted Cassette (Double Flow) Type

    Thin, lightweight, and easy to install in

    narrow ceiling spaces

    FXCQ20M/FXCQ25M/FXCQ32M

    FXCQ40M/FXCQ50M/FXCQ63M

    FXCQ80M/FXCQ125M

    FXCQ-M 20

    32/27

    25/32

    34/28

    63

    37/32

    40/50

    34/29

    80

    39/34

    125

    44/38

    34/29 36/30 39/3437/32 41/36 46/40

    (dB(A))

    305 mm

    The thin unit (only 305 mm high) can be

    installed in a ceiling space as narrow as

    350 mm. All models feature a compact

    design with a depth of only 600 mm.

    (When a high-efficiency filter is attached, the

    unit's height is 400 mm.)

    Low operation sound level

    Designed with higher airflow suitable for

    high ceiling application up to 3 metres.

    Providing 2 different settings of standardand ceiling soiling prevention, the auto

    swing mechanism realises even distribution

    of airflow and room temperature.

    Two types of optional high-efficiency filter

    are available (65% and 95%, colourimetric

    method).

    A long-life filter (maintenance free up to one

    year) is equipped as standard accessory.

    Drain pump is equipped as standard

    accessory with 600 mm lift.

    Major maintenance work can be performed by

    removing the panel. A flat-type suction grille

    and a detachable blade make cleaning easy.

    220 V

    240 V

    Sound level(H/L)

    600 mm600 mm

    Ceiling Mounted Cassette Corner Type

    Slim design for flexible installation

    Main body

    Air discharge grille(Option)

    Set for front discharge using a suspended ceiling.

    Downward discharge is shut off and air is blown straight out(front discharge).

    Front discharge is possible with an air

    discharge unit (option), which allows the

    installation in the drop-ceiling or sagging wall.

    Single-flow type allows effective air discharge

    from corner or from drop-ceiling.

    Providing 3 different settings of standard, draft

    prevention and ceiling soiling prevention, the

    auto swing mechanism realises even

    distribution of airflow and room temperature.

    Main body

    Downward discharge

    Air discharge grille (Option)

    FXKQ25MA/FXKQ32MA

    FXKQ40MA/FXKQ63MA

    3

    32C 30C

    28C 26C24C

    22C

    20C

    2

    1

    0 1 2 3 4 5 6 (m)

    (m)

    500 mm

    Drain pump is equipped as standard

    accessory with 500 mm lift.

    Slim body needs only 220 mm space above the

    ceiling. If you use a panel spacer (option), the

    unit can be installed in the minimum space of

    195 mm.

    A long-life filter (maintenance free up to one

    year) is equipped as standard accessory.

    Panel spacer

    20 mm

    Min.195 mm

  • 8/12/2019 PCV0915_tcm28-1674

    11/36

  • 8/12/2019 PCV0915_tcm28-1674

    12/36

    2221

    Indoor Unit Lineup

    Wall Mounted Type

    Sophisticated design and compact casing

    harmonised with your interior dcor

    Drain pan and air filter can be kept clean by

    mildew-proof polystyrene.

    Compact and stylish design that does not

    detract from the dcor of the room.

    Drain pump kit is available as optional

    accessory, which lifts the drain 1,000 mm from

    the bottom of the unit.

    Auto-swing realises efficiency of air

    distribution. The louvre closes automatically

    when the unit stops.

    5 steps of discharge angle can be set by

    remote controller.

    Washable grille, the front grille can be easily

    removed for washing.

    Discharge angle is automatically set at the

    same angle as the previous operation when

    restarting. (Initial setting: 10 for cooling and

    70 for heating)

    Flexible installation

    Drain pipe can be fitted to from either left or

    right sides.

    Low operation sound level

    46/39

    63

    42/36

    50

    39/34

    40

    37/29

    32

    36/29

    25

    35/29

    20

    Sound level(H/L)

    FXAQ-MA

    (dB(A))

    FXAQ20MA/FXAQ25MA

    FXAQ32MA/FXAQ40MA

    FXAQ50MA/FXAQ63MA

    Drain pump kit

    1,000 mm

    Height of drain-up

    Indoor unit

    Ceiling Suspended Type

    Slim body with quiet and wide airflow

    Adoption of QUIET STREAM FAN

    Drain pump kit (option) can be easily

    incorporated.

    Easy-to-clean flat design

    Maintenance is easier because everything can

    be performed from below the unit.

    Non-dew Flap with no implanted bristles

    FXHQ-MA

    Sound level(H/L)

    32

    36/31

    63

    39/34

    100

    45/37

    (dB(A))Low operation sound level

    Uses the quiet stream fan and manymore advanced technologies.

    Sound absorptionmember

    Turbulent flowis produced

    Straightening vane

    Quiet stream fan

    Installation is easy

    Maintenance is easy

    Drain pump kit

    (built inside main unit)

    600mm

    Bristle-free Flap minimisescontamination and makescleaning simpler.

    Non-dew Flap

    100

    Wide air discharge openings produce a

    spreading 100airflow.

    A long-life filter (maintenance free up to one

    year) is equipped as standard accessory.

    FXHQ32MA/FXHQ63MA

    FXHQ100MA

  • 8/12/2019 PCV0915_tcm28-1674

    13/36

  • 8/12/2019 PCV0915_tcm28-1674

    14/36

  • 8/12/2019 PCV0915_tcm28-1674

    15/36

  • 8/12/2019 PCV0915_tcm28-1674

    16/36

  • 8/12/2019 PCV0915_tcm28-1674

    17/36

  • 8/12/2019 PCV0915_tcm28-1674

    18/36

  • 8/12/2019 PCV0915_tcm28-1674

    19/36

  • 8/12/2019 PCV0915_tcm28-1674

    20/36

  • 8/12/2019 PCV0915_tcm28-1674

    21/36

  • 8/12/2019 PCV0915_tcm28-1674

    22/36

  • 8/12/2019 PCV0915_tcm28-1674

    23/36

  • 8/12/2019 PCV0915_tcm28-1674

    24/36

  • 8/12/2019 PCV0915_tcm28-1674

    25/36

  • 8/12/2019 PCV0915_tcm28-1674

    26/36

    Control Systems

  • 8/12/2019 PCV0915_tcm28-1674

    27/36

    y

    5251

    Advanced Control Systems

    Contact signal

    Ai unit

    (DAM101A51)

    Fan

    Daikin CentralAir ConditioningSystem

    Localmonitoring

    & control

    Multi-PCEthernet

    Sub PC

    Fire alarm

    D -NET

    D -NET

    D -NET

    D -NET

    Wiring adaptor required for connection withother equipment not compatible with D -NET

    Via internet

    Intranet/Internet

    Web Access

    Web Access

    Malfunction reportby E-mail

    Heat Reclaim

    Ventilator

    VRV System

    Centralised control system for easy provision of effective controland monitoring of VRV system functions

    *1Air ConditioningNetwork Service System(Optional Maintenance Service)

    Dio unit(DEC102A51)

    Special Functions Features control and monitoring functions for central A/C products and an Air Conditioning

    Network Service function.

    Using an external contact via DIII-NET, monitors and controls equipment such as lighting,fans, or building security systems.

    *1. There are restrictions in applicable areas and release times, therefore please consult us separately for details.

    Interfacing requirements vary depending on model, and some systems may not be suitable. Please contact your distributor for details.

    Floor visual navigation

    Multi language (English, French, Italian, German, Spanish, Dutch, Portuguese,

    Chinese and Korean)

    Graphical reportMulti-PC access

    Analogue interlock

    Automatic heat/cool change-over

    Temperature limitation

    Sliding temperature

    Energy saving function (ECONO mode) (Option)

    Air Conditioning Network Service System (Optional Maintenance Service)

    Features

    Light Pump

    *2

    Monitor and control from the remote site by Web browser (Option)

    PPD data can be managed from the remote site by Web browser (Option)

    Send malfunction report through the Internet by E-mail (Option)

    Compliant with the RoHS Directive (DAM602B51/52)(refer to page 13 for details)

    DAM602B51/52

  • 8/12/2019 PCV0915_tcm28-1674

    28/36

  • 8/12/2019 PCV0915_tcm28-1674

    29/36

  • 8/12/2019 PCV0915_tcm28-1674

    30/36

  • 8/12/2019 PCV0915_tcm28-1674

    31/36

  • 8/12/2019 PCV0915_tcm28-1674

    32/36

  • 8/12/2019 PCV0915_tcm28-1674

    33/36

  • 8/12/2019 PCV0915_tcm28-1674

    34/36

  • 8/12/2019 PCV0915_tcm28-1674

    35/36

  • 8/12/2019 PCV0915_tcm28-1674

    36/36