21
Latest individual air conditioning
technology adds new real valueto today's buildings
Air conditioning systems that use new refrigerant and save energy are the norm. However, we at Daikin
have gone much further by maximising our advanced technology developed over 25 years as the
leading manufacturer of individual air conditioning systems. Not only top level air conditioning
performance, we also offer minimal space utilisation, efficient building management and a multitude of
other added value features.
Daikins VRV systems include indoor and
outdoor units available in a wide range of
models for various building sizes and
installation conditions. Long refrigerant
piping lengths and other features put few
restrictions on design for great flexibility in
meeting the needs of the building.
Daikin offers a compact design for VRVIII outdoor units by
further optimising equipment functions, exceeding the norm for
air conditioning systems. Compact units facilitate installation in
limited areas, such as rooftops, and take up less effective
space. Easier installation work realises fast completion with timeto spare.
Benefits for INSTALLERS
With Daikin's proprietary inverter technology and cutting-edge
control technology for refrigerant, the VRVIII air conditioning system
operates with outstanding efficiency. This contributes to high energy
savings, which greatly reduces your running costs and facilitates far
better building management.
Benefits for
property OWNERS
To provide a comfortable air
environment, Daikin offers air
treatment systems beyond mere air
conditioning. As well as bringing air to
a comfortable temperature, the airquality can be treated with ventilation,
humidification, and other processes.
Ease of use is realised through
advanced, centralised control
systems.
Benefits for USERS
Benefits for CONSULTANTand DESIGN OFFICES
8/12/2019 PCV0915_tcm28-1674
3/36
43
Outdoor units with large capacities................................................................page 7
Wide range and an increased number of connectable indoor units......page 9
High COPs/Energy savings
Compliant with the RoHS Directive
Extended level difference between outdoor units and indoor units.....page 10
Extended actual and total maximum piping length...................................page 10
High external static pressure..........................................................................page 11
Two types of outdoor unit combinations.....................................................page 11
Developed to facilitate more flexible system design
inlarge-sized buildings
Automatic test operation
Less chances of refrigerant leakage
Double backup operation in compressors and units
Outdoor units designed for low operation
Efficient compressor
Easier installation.....................................................page12
A sense of responsibility..........................................page13
Enhanced comfort....................................................page14
Nighttime quiet operation function
Daikin proudly introduces the VRVIII series, which is well-suited to
large-sized buildings. This air conditioning system provides outdoor
units that extend air conditioning capacity up to 54 HP. It also
incorporates numerous outstanding features, such as a wide range
of outdoor and indoor units, longer actual and total piping length,
and high external static pressure. The VRVIII series provides the
power and versatility you need for flexible design and easy
installation in large-sized buildings.
Contents
Technologies.................................. page 5
Main Features................................ page 7
Control Systems............................page 47Indoor Unit Lineup........................page 15
Outdoor Unit Lineup.....................page 25
Specifications................................ page 27
Indoor units.....................................page 27
Outdoor units..................................page 34
Option List.......................................page 44
Indoor units....................................page 44
Outdoor units.................................page 46
Air Treatment Equipment Lineup...page 58
Outdoor-air processing unit...........page 59
Heat Reclaim Ventilator withDX-coil and humidifier....................page 63
Heat Reclaim Ventilator..................page 67
8/12/2019 PCV0915_tcm28-1674
4/36
8/12/2019 PCV0915_tcm28-1674
5/36
Large capacities for large-sized buildings Large capacities for large-sized buildings
Main Features
87
Daikins indoor unit system offers a large number of connectable indoor units64! Furthermore, our wide range ofindoor units includes 15 types and 73 models* to meet the needs of customers.
Indoor units
The previous outdoor unit had a maximum output of 48 HP. The VRVIII have a top output of54 HP! By connecting main units (up to 18 HP each), a high-capacity system (up to 54 HP)that is compact yet flexible can be achieved.
By providing a range of horse powerlevels in 2 HP increments*, Daikinresponds flexibly to customer needs.
* Refer to page 26 for combination details.
Outdoor units
48 HP 54 HP
Ceiling MountedCassette(Round Flow)
Type Model Name Capacity Range
Capacity Index 20
0.8 HP
40
1.6 HP
62.5
2.5 HP
80
3.2 HP
100
4 HP
125
5 HP
140
6 HP
200
8 HP
250
10 HP
50
2 HP
31.25
1.25 HP
25
1 HP
20 40 63 80 100 125 140 200 250503225
Ceiling MountedCassette(Double Flow)
FXCQ-MVE
Ceiling MountedCassette(Compact Multi Flow)
FXZQ-MVE
Slim Ceiling
Mounted Duct
Ceiling Mounted
Duct
Ceiling Suspended
Wall Mounted
Floor Standing
Concealed
Floor Standing
Ceiling MountedCassette Corner
FXDQ-NBVE(with drain pump)
FXDQ-NBVET(without drain pump)
FXMQ-PVE
FXMQ-MAVE
FXHQ-MAVE
FXAQ-MAVE
FXLQ-MAVE
FXNQ-MAVE
FXKQ-MAVE
FXDQ-PBVET(without drain pump)
FXDQ-PBVE
(with drain pump)
(900/1,100 mm width type)
(700 mm width type)
R-410A VRV system indoor units are not compatible with the R-22 VRV system.Note:
2 HP increments
Offering a higher capacity of up to 54 HP,
responding to the needs of large-sized buildings
* Except for 5 HP 30, 32, 34, 36 HP
38, 40, 42, 44, 46 HP 48, 50, 52, 54 HP
5 HP 8, 10 HP 12, 14, 16, 18 HP
20, 22, 24, 26, 28 HP
VRVIIMA series
New
The latest technology is implemented in the VRVIII system. Surpassing even the VRVII, the VRVIII responds to
more of the needs of our customers that require air-conditioning solutions for large-sized buildings.
Major advances of theVRVIII over the VRVII for large-sized buildings
BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data for details.Note:
Connection unit series indoor units (50 Hz only)
* 14 types and 70 models for 60 Hz specifications.
Ceiling Suspended
Cassette
Type Model Name
1.6 HP0.8 HP 1.25 HP1 HP
FXUQ-MAV1
20 4031.2525
BEVQ125MAVE
5 HP
BEVQ100MAVEBEVQ71MAVE
2 HP 4 HP3 HP
50 12510071
Capacity Range
4020 3225 12550 10071
Connection Unit
Capacity Index
FXFQ-PVE
New New New New New
New
8/12/2019 PCV0915_tcm28-1674
6/36
8/12/2019 PCV0915_tcm28-1674
7/36
Large capacities for large-sized buildings
Main Features
Easier installation
Automatic test operation
Simply press the test operation button and the unit performs an automatic system check, including wiring,shutoff valves, and sensors. The results are returned automatically after the check finishes.
High external static pressure 78.4 Pa (8 mm H2O)
58.8Pa 78.4Pa
Approx.
33.3%increase!
Selectable from two types of combinations
Normal type (Space saving type)
High-COP type (Energy saving type)
8
10
12
14
16
18
8
1
5
5
1
22
2
24
2
26
2
10
1
12
1
16
1
14
1
20
2
18
1
Total number
of connected
outdoor units
HP
Single unit
Single outdoor units Double outdoor units Double outdoor units
* Refer to page 26 for outdoor combination details.
38
3
42
3
40
3
44
3
46
3
48
3
50
3
52
3
54
3
Triple outdoor units
* Refer to page 26 for outdoor combination details.
8
10
12
14
16
18
18
2
16
2
36
3
38
3
24
3
26
3
30
3
28
3
34
3
32
3
Total number
of connected
outdoor units
HP
Single unit
Double outdoor units Triple outdoor units
40
3
42
3
46
3
44
3
50
3
48
3
Triple outdoor units
28
2
30
2
34
2
36
2
32
2
Higher external static pressure has been achieved thanks to the fan grilles and thedual DC fans that reduce internal pressure loss. Exceeding the previous 58.8 Pa (6mm H2O) level, Daikin now offers 78.4 Pa(8 mm H2O) external static pressure by
field setting to meet the requirements forinstallation on each floor, often requestedfor large-sized buildings.
VRVII
MA series
1211
78.4Pa
8/12/2019 PCV0915_tcm28-1674
8/36
8/12/2019 PCV0915_tcm28-1674
9/36
8/12/2019 PCV0915_tcm28-1674
10/36
Indoor Unit Lineup
1817
Ceiling Mounted Cassette (Double Flow) Type
Thin, lightweight, and easy to install in
narrow ceiling spaces
FXCQ20M/FXCQ25M/FXCQ32M
FXCQ40M/FXCQ50M/FXCQ63M
FXCQ80M/FXCQ125M
FXCQ-M 20
32/27
25/32
34/28
63
37/32
40/50
34/29
80
39/34
125
44/38
34/29 36/30 39/3437/32 41/36 46/40
(dB(A))
305 mm
The thin unit (only 305 mm high) can be
installed in a ceiling space as narrow as
350 mm. All models feature a compact
design with a depth of only 600 mm.
(When a high-efficiency filter is attached, the
unit's height is 400 mm.)
Low operation sound level
Designed with higher airflow suitable for
high ceiling application up to 3 metres.
Providing 2 different settings of standardand ceiling soiling prevention, the auto
swing mechanism realises even distribution
of airflow and room temperature.
Two types of optional high-efficiency filter
are available (65% and 95%, colourimetric
method).
A long-life filter (maintenance free up to one
year) is equipped as standard accessory.
Drain pump is equipped as standard
accessory with 600 mm lift.
Major maintenance work can be performed by
removing the panel. A flat-type suction grille
and a detachable blade make cleaning easy.
220 V
240 V
Sound level(H/L)
600 mm600 mm
Ceiling Mounted Cassette Corner Type
Slim design for flexible installation
Main body
Air discharge grille(Option)
Set for front discharge using a suspended ceiling.
Downward discharge is shut off and air is blown straight out(front discharge).
Front discharge is possible with an air
discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.
Single-flow type allows effective air discharge
from corner or from drop-ceiling.
Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
Main body
Downward discharge
Air discharge grille (Option)
FXKQ25MA/FXKQ32MA
FXKQ40MA/FXKQ63MA
3
32C 30C
28C 26C24C
22C
20C
2
1
0 1 2 3 4 5 6 (m)
(m)
500 mm
Drain pump is equipped as standard
accessory with 500 mm lift.
Slim body needs only 220 mm space above the
ceiling. If you use a panel spacer (option), the
unit can be installed in the minimum space of
195 mm.
A long-life filter (maintenance free up to one
year) is equipped as standard accessory.
Panel spacer
20 mm
Min.195 mm
8/12/2019 PCV0915_tcm28-1674
11/36
8/12/2019 PCV0915_tcm28-1674
12/36
2221
Indoor Unit Lineup
Wall Mounted Type
Sophisticated design and compact casing
harmonised with your interior dcor
Drain pan and air filter can be kept clean by
mildew-proof polystyrene.
Compact and stylish design that does not
detract from the dcor of the room.
Drain pump kit is available as optional
accessory, which lifts the drain 1,000 mm from
the bottom of the unit.
Auto-swing realises efficiency of air
distribution. The louvre closes automatically
when the unit stops.
5 steps of discharge angle can be set by
remote controller.
Washable grille, the front grille can be easily
removed for washing.
Discharge angle is automatically set at the
same angle as the previous operation when
restarting. (Initial setting: 10 for cooling and
70 for heating)
Flexible installation
Drain pipe can be fitted to from either left or
right sides.
Low operation sound level
46/39
63
42/36
50
39/34
40
37/29
32
36/29
25
35/29
20
Sound level(H/L)
FXAQ-MA
(dB(A))
FXAQ20MA/FXAQ25MA
FXAQ32MA/FXAQ40MA
FXAQ50MA/FXAQ63MA
Drain pump kit
1,000 mm
Height of drain-up
Indoor unit
Ceiling Suspended Type
Slim body with quiet and wide airflow
Adoption of QUIET STREAM FAN
Drain pump kit (option) can be easily
incorporated.
Easy-to-clean flat design
Maintenance is easier because everything can
be performed from below the unit.
Non-dew Flap with no implanted bristles
FXHQ-MA
Sound level(H/L)
32
36/31
63
39/34
100
45/37
(dB(A))Low operation sound level
Uses the quiet stream fan and manymore advanced technologies.
Sound absorptionmember
Turbulent flowis produced
Straightening vane
Quiet stream fan
Installation is easy
Maintenance is easy
Drain pump kit
(built inside main unit)
600mm
Bristle-free Flap minimisescontamination and makescleaning simpler.
Non-dew Flap
100
Wide air discharge openings produce a
spreading 100airflow.
A long-life filter (maintenance free up to one
year) is equipped as standard accessory.
FXHQ32MA/FXHQ63MA
FXHQ100MA
8/12/2019 PCV0915_tcm28-1674
13/36
8/12/2019 PCV0915_tcm28-1674
14/36
8/12/2019 PCV0915_tcm28-1674
15/36
8/12/2019 PCV0915_tcm28-1674
16/36
8/12/2019 PCV0915_tcm28-1674
17/36
8/12/2019 PCV0915_tcm28-1674
18/36
8/12/2019 PCV0915_tcm28-1674
19/36
8/12/2019 PCV0915_tcm28-1674
20/36
8/12/2019 PCV0915_tcm28-1674
21/36
8/12/2019 PCV0915_tcm28-1674
22/36
8/12/2019 PCV0915_tcm28-1674
23/36
8/12/2019 PCV0915_tcm28-1674
24/36
8/12/2019 PCV0915_tcm28-1674
25/36
8/12/2019 PCV0915_tcm28-1674
26/36
Control Systems
8/12/2019 PCV0915_tcm28-1674
27/36
y
5251
Advanced Control Systems
Contact signal
Ai unit
(DAM101A51)
Fan
Daikin CentralAir ConditioningSystem
Localmonitoring
& control
Multi-PCEthernet
Sub PC
Fire alarm
D -NET
D -NET
D -NET
D -NET
Wiring adaptor required for connection withother equipment not compatible with D -NET
Via internet
Intranet/Internet
Web Access
Web Access
Malfunction reportby E-mail
Heat Reclaim
Ventilator
VRV System
Centralised control system for easy provision of effective controland monitoring of VRV system functions
*1Air ConditioningNetwork Service System(Optional Maintenance Service)
Dio unit(DEC102A51)
Special Functions Features control and monitoring functions for central A/C products and an Air Conditioning
Network Service function.
Using an external contact via DIII-NET, monitors and controls equipment such as lighting,fans, or building security systems.
*1. There are restrictions in applicable areas and release times, therefore please consult us separately for details.
Interfacing requirements vary depending on model, and some systems may not be suitable. Please contact your distributor for details.
Floor visual navigation
Multi language (English, French, Italian, German, Spanish, Dutch, Portuguese,
Chinese and Korean)
Graphical reportMulti-PC access
Analogue interlock
Automatic heat/cool change-over
Temperature limitation
Sliding temperature
Energy saving function (ECONO mode) (Option)
Air Conditioning Network Service System (Optional Maintenance Service)
Features
Light Pump
*2
Monitor and control from the remote site by Web browser (Option)
PPD data can be managed from the remote site by Web browser (Option)
Send malfunction report through the Internet by E-mail (Option)
Compliant with the RoHS Directive (DAM602B51/52)(refer to page 13 for details)
DAM602B51/52
8/12/2019 PCV0915_tcm28-1674
28/36
8/12/2019 PCV0915_tcm28-1674
29/36
8/12/2019 PCV0915_tcm28-1674
30/36
8/12/2019 PCV0915_tcm28-1674
31/36
8/12/2019 PCV0915_tcm28-1674
32/36
8/12/2019 PCV0915_tcm28-1674
33/36
8/12/2019 PCV0915_tcm28-1674
34/36
8/12/2019 PCV0915_tcm28-1674
35/36
8/12/2019 PCV0915_tcm28-1674
36/36