8/9/2019 Passive Components Catalogue
1/39
HUBER+SUHNER Excellence in Connectivity Solutions
FIBER OPTIC
PASSIVE COMPONENTS
GENERAL CATALOGUE
Edition 2008
8/9/2019 Passive Components Catalogue
2/39
FURTHER FIBER OPTIC CATALOGUES
System catalogue LISAItem Nr. 23040188
CablesItem Nr. 84019826
Cabling systemsItem Nr. 23029084
Connectors and AssembliesItem Nr. 84019828
8/9/2019 Passive Components Catalogue
3/39
1HUBER+SUHNER FIBER OPTICS
Content
Introduction and Terminologypage 2
Couplerspage 4
Multiplexers (WDM)page 24
Coupler and WDM housingspage 27
Attenuatorspage 28
Connector codepage 34
8/9/2019 Passive Components Catalogue
4/39
2 HUBER+SUHNER FIBER OPTICS
Introduction
Fused couplersPassive optical couplers are branching devices with more than 2 fiber ports. Such components distribute the opti-cal power among fibers in a predetermined way. They combine (coupler) or divide (splitter) optical signals inoptical networks. These optical components are used in central offices, customer premises and in outside plantapplications. H+S couplers are manufactured by the fused biconical tapered (FBT) technology. On request thein and outgoing ports of the coupler can be connectorized with all types of connectors. Couplers can be inte-grated into different organiser trays, modules, panels and subassemblies (see System catalogue LISA).
Fused WDMsFused Wavelength Division Multiplexers are 1x2 branching devices used to combine or to divide two differentwavelengths. Due to their manufacturing technology, FBT WDMs have a sinusoidal transfer function. Their main
features are low excess loss, high isolation and high reliability over a narrow wavelength window.
Fiber optic attenuatorsFiber optic attenuators are devices that reduce signal power in fiber optic links by inducing a fixed loss. They areused to control the power level of optical signals at the outputs of light sources and electrical-to-optical (E/O)converters. They are also used to test the linearity and dynamic range of photo sensors and photo detectors.Fiber optic attenuators use different methods of attenuation, such as absorption or scattering.
Quality assurance and traceabilityEach device is identified by a serial number so it is possible at any time to identify the manufacturing param-eters, the workstation, the operator, the material used and the final characterisation measurements.
Screening tests on every single device
Test+Measurement Range
High temperature storage +85 C for 50 hours
Thermal cycling 10 cycles, 40 to +85 C, dwell time 1h, slopes 3 C/min
Insertion loss (see device specifications)
Directivity (see device specifications)
Qualification performance testsTest Range
Temperature cyclingIEC 61300-2-22 40 C to +70C 1h hold time, 1C/min
1h dwell time, 20 cycles
Damp heat IEC 61300-2-19 +85 C / 93% RH for 14 days
Condensation cycling IEC 61300-2-21 10 cycles
Water immersionIEC 61300-2-45 +43 C (2 C), pH of 5.5 (0.5) for 7days
Vibration IEC 61300-2-1 10 to 2.000 Hz, 20gs, 3 axes
Shock IEC 61300-2-9 3 axes, 40gs, 11ms, 5 per each direction
Fiber torsion IEC 61300-2-5 180 twist, 5 times both directions,5 N force
Cable retention IEC 61300-2-42 5 N for 1 min.
8/9/2019 Passive Components Catalogue
5/39
3HUBER+SUHNER FIBER OPTICS
Introduction
Terminologies of passive network components
Term Description
AttenuationThe decrease in signal strength caused by absorption and scattering. Attenuationis usually expressed in dB.
AttenuatorA passive optical component that intentionally reduces the optical power propa-gating in a fiber.
Broadband Covering a wide range of wavelength.
Center wavelength(s) The nominal operating wavelength(s).
CouplerA passive device that distributes optical power among two or more ports. Alsocalled splitter.
Coupling ratio
The percentage of light transferred to a receiving output port with respect to thetotal power of all output ports.
Decibel (dB)Unit for measuring the relative strength of a signal. Power level referenced indecibels to a microwatt.
Demultiplex The process of separating optical channels.
Directivity
Also referred to as nearend crosstalk, it is the amount of power observed at agiven input port with respect to an initial input power.
Excess loss The ratio of the total output power of a passive component with respect to theinput power.
Insertion loss
A sum of attenuation expressed in dB for a particular path through a component.Insertion loss includes excess loss, splitting loss and polarisation effects.
Isolation
Also referred to as far-end cross-talk or far-end isolation. Predominantly used inreference to WDM products, it is a measure of light at an undesired wavelengthat any given port.
Polarisation Dependent Loss (PDL) Variation of insertion loss with respect to SOP (State Of Polarisation).
Return lossLight that is reflected back along the path of transmission, from either the cou-pling region, the connector or a terminated fiber.
UniformityThe maximum insertion loss difference between output ports of a splitter withinoperating bandwidth.
Wavelength Division Multiplexing(WDM)
A transition technique by which separate optical channels, distinguished bywavelength, are multiplexed onto an optical fiber for transmission.
WavelengthThe distance between the same two points on adjacent waves; the time requiredfor a wave to complete a single cycle.
P1 50%
P2 50%
P0 100%
P0R = 0
Pr
P0P1
P2
P0P1
P2
1 + 21 + 2
2 + 1
8/9/2019 Passive Components Catalogue
6/39
4
100%
50%
0%
1260 nm 1360 nm 1480 nm 1580 nm
HUBER+SUHNER FIBER OPTICS
Dual bandDual band couplers can be operated at both centerwavelengths, 1310 nm and 1550 nm.
12 / 22 Dual Band FBT Coupler
Singlemode
Generic specifications
Parameter Value Test method
PDL 0.20 dB IEC 61300-3-2
Directivity 55 dB IEC 61300-3-20
Return loss 55 dB IEC 61300-3-6
Optical power (max.) 500 mW IEC 61300-2-14
Fiber type ITU-T G.652 SMF
Temperature sensitivity (max.) 0.002 dB/C
Typical excess loss 0.10 dB
Operating temperature 25 C to +70 C
Storage temperature 40 C to +85 C
FeaturesLow excess loss
Low polarisation dependent loss (PDL)
Excellent mechanical and environmentalperformance
ApplicationsPassive optical networks (B-PON, G-PON, E-PON)
Network monitoring
CATV
All fiber amplifiers
Performance
8/9/2019 Passive Components Catalogue
7/39
5HUBER+SUHNER FIBER OPTICS
Detail specifications
Parameter Value
Wavelength band 12601360 and 14801580 nm
Uniformity 0.7 dB
Insertion loss (max.) split ratio
50 / 50 % 3.7 dB
40 / 60 % 4.7 / 2.7 dB
30 / 70 % 6.0 / 2.0 dB
20 / 80 % 7.8 / 1.3 dB
10 / 90 % 11.2 / 0.8 dB
5 / 95 % 14.4 / 0.5 dB
1 / 99 % 21.5 / 0.3 dB
Device packaging, standard
Cable/fiber type Package Package dimensions (mm)
Bare fiber, 250 m P1 3.0 mm; L = 50 mm (tubular package)
TPE loose tube, 0.9 mm P2 3.0 mm; L = 70 mm (tubular package)
TPE loose tube, 0.9 mm or simplexcable, 2.0 mm
P3L = 85 mm; W = 18 mm; H = 7.5 mm(ruggedised package)
12 / 22 Dual Band FBT Coupler
Singlemode
8/9/2019 Passive Components Catalogue
8/39
6
100%
50%
0%
HUBER+SUHNER FIBER OPTICS
FeaturesLow excess loss
Low polarisation dependent loss (PDL)
Excellent mechanical and environmentalperformance
ApplicationsPassive optical networks (B-PON, G-PON, E-PON)
Network monitoring
CATV
All fiber amplifiers
Single bandSingle band couplers are specially optimised for a sin-gle center wavelength, either for1310 nm or1550 nm.
Generic specifications
Parameter Value Test method
PDL 0.20 dB IEC 61300-3-2
Directivity 55 dB IEC 61300-3-20
Return loss 55 dB IEC 61300-3-6
Optical power (max.) 500 mW IEC 61300-2-14
Fiber type ITU-T G.652 SMF
Temperature sensitivity (max.) 0.002 dB/C
Typical excess loss 0.10 dB
Operating temperature 25 C to +70 C
Storage temperature 40 C to +85 C
12 / 22 Single Band FBT Coupler
Singlemode
Performance
1310 nm 40 or 1550 nm 40
8/9/2019 Passive Components Catalogue
9/39
7HUBER+SUHNER FIBER OPTICS
Detail specifications
Parameter Value
Wavelength band 1310 40 or 1550 40 nm
Uniformity 0.6 dB
Insertion loss (max.) split ratio
50 / 50 % 3.4 dB
40 / 60 % 4.4 / 2.5 dB
30 / 70 % 5.6 / 1.8 dB
20 / 80 % 7.5 / 1.1 dB
10 / 90 % 10.8 / 0.6 dB
5 / 95 % 14.0 / 0.4 dB
1 / 99 % 21.0 / 0.2 dB
Device packaging, standard
Cable/fiber type Package Package dimensions (mm)
Bare fiber, 250 m P1 3.0 mm; L = 50 mm (tubular package)
TPE loose tube, 0.9 mm P2 3.0 mm; L = 70 mm (tubular package)
TPE loose tube, 0.9 mm or simplexcable, 2.0 mm
P3L = 85 mm; W = 18 mm; H = 7.5 mm(ruggedised package)
12 / 22 Single Band FBT Coupler
Singlemode
8/9/2019 Passive Components Catalogue
10/39
8 HUBER+SUHNER FIBER OPTICS
Ordering code Description
BFC-5050splitting ratio(applies for 12 or 22 couplers only)
0199 1:99 2080 20:80
0298 2:98 3070 30:70
0595 5:95 4060 40:60
1090 10:90 5050 50:50
12 ports
12 2 2
01 wavelengths
01 1310 and 1550 nm dual band
02 1310 nm single band
03 1550 nm single band
P2 package
P1 3.0 mm / L=50 mm (for 250 mcoated fiber only)
P2 3.0 mm / L=70 mm for (0.9 mmTPE loose tube)
P3L=85 mm / W=18 mm / H=7.5 mm(for 0.9 mm TPE loose tube
or 2.0 mm cable jacket)001 version number
001 standard, 9 m singlemode fiber
1 cable/fiber length
1 in meters, max. 3 meters
X1 cable/fiber type
X0 250 m fiber with package P1 only(without connectors only)
X10.9 mm TPE loose tubewith package P2 or P3
X3 2.0 mm cable with package P3 only70/70 connector code 1st side / 2nd side
see last page for connector code
BFC-5050-12-01-P2-001-1-X1-70/70ordering code example for fused 12 / 22coupler singlemode
12 / 22 FBT Coupler
Singlemode
8/9/2019 Passive Components Catalogue
11/39
9
12
50/50
HUBER+SUHNER FIBER OPTICS
1 N / 2 N tree fused couplers are producedthrough a concatenation of 12 couplers.
Dual band couplers can be operated at both centerwavelength, 1310 nm and 1550 nm.
Asymmetric power split ratios upon customer require-ment are possible (e.g. 13 with 5% / 5% / 90%power splitting).
1N / 2N Dual Band Tree Fused Coupler
Singlemode
coupler housing output
input
splice
FeaturesLow excess loss
Low polarisation dependent loss (PDL)
Excellent mechanical and environmentalperformance
ApplicationsPassive optical networks (B-PON, G-PON, E-PON)
Network monitoring
CATV
All fiber amplifiers
Generic specifications
Parameter Value Test method
PDL 0.20 dB (N 4) 0.50 dB (N > 4)
IEC 61300-3-2
Directivity 55 dB IEC 61300-3-20
Return loss 55 dB IEC 61300-3-6
Optical power (max.) 500 mW IEC 61300-2-14
Fiber type ITU-T G.652 SMF
Temperature sensitivity (max.) 0.002 dB/C
Typical excess loss 0.10 dB
Operating temperature 25 C to +70 C
Storage temperature 40 C to +85 C
8/9/2019 Passive Components Catalogue
12/39
10 HUBER+SUHNER FIBER OPTICS
Detail specifications
Parameter Value
Wavelength band
12601360 and 14801580 nm
insertion loss uniformity
Insertion loss max. /uniformity max.
ports
13 5.8 dB 1.0 dB
14 / 24 7.3 dB 1.2 dB
16 / 26 9.3 dB 1.5 dB
18 / 28 10.8 dB 1.7 dB
112 / 212 12.8 dB 2.0 dB
116 / 216 14 dB 2.3 dB
124 16 dB 2.6 dB
132 18 dB 2.8 dB
Device packaging, standard
Version Package Package dimensions (mm)
13 / 14 / 24 P4 L=100 ; W=80 ; H=7.5
15 / 16 / 26 / 18 / 28 P5 L=136 ; W=96 ; H=9.5
112 / 212 / 116 / 216 P6 L=160 ; W=110 ; H=11
1N / 2N Dual Band Tree Fused Coupler
Singlemode
8/9/2019 Passive Components Catalogue
13/39
11
12
50/50
HUBER+SUHNER FIBER OPTICS
1 N tree fused couplers are produced through aconcatenation of 12 couplers.
Single band couplers are specially optimised for asingle center wavelength, either for 1310 or 1550 nm.
Asymmetric power split ratios upon customer require-ment are possible (e.g. 13 with 5% / 5% / 90%power splitting).
coupler housing output
input
splice
FeaturesLow excess loss
Low polarisation dependent loss (PDL))
Excellent mechanical and environmentalperformance
ApplicationsPassive optical networks (B-PON, G-PON, E-PON)
Network monitoring
CATV
All fiber amplifiers
Generic specifications
Parameter Value Test method
PDL 0.20 dB (N 4) 0.50 dB (N > 4)
IEC 61300-3-2
Directivity 55 dB IEC 61300-3-20
Return loss 55 dB IEC 61300-3-6
Optical power (max.) 500 mW IEC 61300-2-14
Fiber type ITU-T G.652 SMF
Temperature sensitivity (max.) 0.002 dB/C
Typical excess loss 0.10 dB
Operating temperature 25 C to +70 C
Storage temperature 40 C to +85 C
1N / 2N Single Band Tree Fused Coupler
Singlemode
8/9/2019 Passive Components Catalogue
14/39
12 HUBER+SUHNER FIBER OPTICS
Detail specifications
Parameter Value
Wavelength band 1310 40 or 1550 40 nm
insertion loss uniformity
Insertion loss max. /uniformity max.
ports
13 5.3 dB 0.9 dB
14 / 24 6.8 dB 1.0 dB
16 / 26 8.9 dB 1.3 dB
18 / 28 10.4 dB 1.5 dB
112 / 212 12.0 dB 1.8 dB
116 / 216 13.6 dB 2.0 dB
124 15.5 dB 2.3 dB
132 17.5 dB 2.5 dB
Device packaging, standard
Version Package Package dimensions (mm)
13 / 14 / 24 P4 L=100 ; W=80 ; H=7.5
15 / 16 / 26 / 18 / 28 P5 L=136 ; W=96 ; H=9.5112 / 212 / 116 / 216 P6 L=160 ; W=110 ; H=11
1N / 2N Single Band Tree Fused Coupler
Singlemode
8/9/2019 Passive Components Catalogue
15/39
13HUBER+SUHNER FIBER OPTICS
Ordering code Description
BFC-TREETREE
(applies for 1N or 2N concatenated tree fused couplers)
14 ports
13 112 212
14 24 116 216
16 26 124
18 28 132
01 wavelengths
01 1310 and 1550 nm dual band
02 1310 nm single band
03 1550 nm single band
P4 package for 0.9 mm tube jacket or 2.0 mm cable
P4 L=100 mm; W = 80 mm; H = 7.5 mm
P5 L=136 mm; W = 96 mm; H = 9.5 mm
P6 L=160 mm; W = 110 mm; H = 11 mm
001 version number
001 standard, 9 m singlemode fiber
1 cable length
1 in meters, max. 3 meters
X1 cable type
X1 0.9 mm TPE loose tube
X3 2.0 mm cable
70/70 connector code 1st side / 2nd side
see last page for connector code
BFC-TREE-14-01-P4-001-1-X1-70/70ordering code example for fused 1N/2N Treecoupler singlemode
1N / 2N Tree Fused Coupler
Singlemode
8/9/2019 Passive Components Catalogue
16/39
14
100%
50%
0%
HUBER+SUHNER FIBER OPTICS
FeaturesStable environmental performances
Low excess loss
High uniformity
ApplicationsData link, LAN
Network monitoring and mirroring
Optical sensors
Test equipments
BroadbandBroadband couplers are specially optimised for aband range from 800 nm to 1600 nm.
Generic specifications
Parameter Value Test method
Directivity 40 dB IEC 61300-3-20
Return loss 40 dB IEC 61300-3-6
Optical power (max.) 5 W IEC 61300-2-14
Typical excess loss 0.10 dB
Fiber type 50/125 m
Temperature sensitivity (max.) 0.002 dB/C
Operating temperature 25C to + 70C
Storage temperature 40C to + 85C
12 / 22 Broadband FBT Coupler 50/125 m
Multimode
Performance
800 nm to 1600 nm
8/9/2019 Passive Components Catalogue
17/39
8/9/2019 Passive Components Catalogue
18/39
16
100%
50%
0%
HUBER+SUHNER FIBER OPTICS
FeaturesStable environmental performances
Low excess loss
High uniformity
ApplicationsData link, LAN
Network monitoring and mirroring
Optical sensors
Test equipments
BroadbandBroadband couplers are specially optimised for aband range from 800 nm to 1600 nm.
Generic specifications
Parameter Value Test method
Directivity 40 dB IEC 61300-3-20
Return loss 40 dB IEC 61300-3-6
Optical power (max.) 5 W IEC 61300-2-14
Typical excess loss 0.10 dB
Fiber type 62.5/125 m
Temperature sensitivity (max.) 0.002 dB/C
Operating temperature 25C to + 70C
Storage temperature 40C to + 85C
12 / 22 Broadband FBT Coupler 62.5/125 m
Multimode
Performance
800 nm to 1600 nm
8/9/2019 Passive Components Catalogue
19/39
17HUBER+SUHNER FIBER OPTICS
Detail specifications for 12 or 22 couplers
Parameter Value
Wavelength band 800 1600 nm
Uniformity 1.5 dB (for 50/50)
Insertion loss (max.) split ratio
50 / 50 % 4.9 dB
40 / 60 % 6.0 / 4.0 dB
30 / 70 % 7.0 / 3.0 dB
20 / 80 % 9.0 / 2.0 dB
10 / 90 % 12.8 / 1.8 dB
5 / 95 % 14.0 / 1.5 dB
1 / 99 % 22.0 / 1.0 dB
Device packaging, standard
Cable/fiber type Package Package dimensions (mm)
Bare fiber, 250 m P1 3.0 mm; L = 50 mm (tubular package)
TPE loose tube, 0.9 mm P2 3.0 mm; L = 70 mm (tubular package)
TPE loose tube, 0.9 mm or simplexcable, 2.0 mm
P3 L = 85 mm; W = 18 mm; H = 7.5 mm (ruggedised package)
12 / 22 Broadband FBT Coupler 62.5/125 m
Multimode
8/9/2019 Passive Components Catalogue
20/39
8/9/2019 Passive Components Catalogue
21/39
19
12
50/50
HUBER+SUHNER FIBER OPTICS
1 N/2 N tree fused couplers are producedthrough a concatenation of 12 couplers.
Broadband couplers are specially optimised for aband range from 800 nm to 1600 nm.
Asymmetric power split ratios upon customer require-ment are possible (e.g. 13 with 5% / 5% / 90%power splitting).
1N/2N Broadband Tree Fused Coupler 50/125 m
Multimode
coupler housing output
input
splice
FeaturesStable environmental performances
Low excess loss
High uniformity
ApplicationsData link, LAN
Network monitoring and mirroring
Optical sensors
Test equipments
Generic specifications
Parameter Value Test method
Directivity 40 dB IEC 61300-3-20
Return loss 40 dB IEC 61300-3-6
Optical power (max.) 5 W IEC 61300-2-14
Typical excess loss 0.10 dB
Fiber type 50/125 m
Temperature sensitivity (max.) 0.002 dB/C
Operating temperature 25C to + 70C
Storage temperature 40C to + 85C
8/9/2019 Passive Components Catalogue
22/39
20 HUBER+SUHNER FIBER OPTICS
Detail specifications for 1N tree couplers
Parameter Value
Wavelength band 800 1600 nm
insertion loss uniformity
Insertion loss max. /uniformity max.
ports
13 5.8 dB 1.0 dB
14 / 24 7.3 dB 1.2 dB
18 / 28 10.8 dB 1.7 dB
116 / 216 14.0 dB 2.3 dB
Device packaging, standard
Version Package Package dimensions (mm)
13 / 14 / 24 P4 L=100 ; W=80 ; H=7.5
18 / 28 P5 L=136 ; W=96 ; H=9.5
116 / 216 P6 L=160 ; W=110 ; H=11
1N / 2N Broadband Tree Fused Coupler 50/125 m
Multimode
8/9/2019 Passive Components Catalogue
23/39
21
12
50/50
HUBER+SUHNER FIBER OPTICS
1 N/2 N tree fused couplers are producedthrough a concatenation of 12 couplers.
Broadband couplers are specially optimised for aband range from 800 nm to 1600 nm.
Asymmetric power split ratios upon customer require-ment are possible (e.g. 13 with 5% / 5% / 90%power splitting).
1N / 2N Broadband Tree Fused Coupler 62.5/125 m
Multimode
coupler housing output
input
splice
FeaturesStable environmental performances
Low excess loss
High uniformity
ApplicationsData link, LAN
Network monitoring and mirroring
Optical sensors
Test equipments
Generic specifications
Parameter Value Test method
Directivity 40 dB IEC 61300-3-20
Return loss 40 dB IEC 61300-3-6
optical power (max.) 5 W IEC 61300-2-14
Typical excess loss 0.10 dB
Fiber type 62.5/125 m
Temperature sensitivity (max.) 0.002 dB/C
Operating temperature 25C to + 70C
Storage temperature 40C to + 85C
8/9/2019 Passive Components Catalogue
24/39
22 HUBER+SUHNER FIBER OPTICS
Detail specifications for 1N tree couplers
Parameter Value
Wavelength band 800 1600 nm
insertion loss uniformity
Insertion loss max. /uniformity max.
ports
13 5.8 dB 1.0 dB
14 / 24 7.3 dB 1.2 dB
18 / 28 10.8 dB 1.7 dB
116 / 216 14.0 dB 2.3 dB
Device packaging, standard
Version Package Package dimensions (mm)
13 / 14 / 24 P4 L=100 ; W=80 ; H=7.5
18 / 28 P5 L=136 ; W=96 ; H=9.5
116 / 216 P6 L=160 ; W=110 ; H=11
1N / 2N Broadband Tree Fused Coupler 62.5/125 m
Multimode
8/9/2019 Passive Components Catalogue
25/39
23HUBER+SUHNER FIBER OPTICS
Ordering code Description
BFC-TREETREE
(applies for 1N or 2N concatenated tree fused couplers)
14 ports
13
14 24
18 28
116 216
11 wavelengths
11 800 to 1600 nm broadband
P4 package for 0.9 mm tube jacket or 2.0 mm cable
P4 L=100 mm; W = 80 mm; H = 7.5 mm
P5 L=136 mm; W = 96 mm; H = 9.5 mm
P6 L=160 mm; W = 110 mm; H = 11 mm
500 version number
500 standard, 50 m multimode fiber
600 standard, 62.5 m multimode fiber
1 cable/fiber length
1 in meters, max. 3 meters
X1 cable/fiber type
X0 250 m fiber with package P1 only(without connectors only)
X1 0.9 mm TPE loose tubewith package P2 or P3
X3 2.0 mm cable with package P3 only
70/70 connector code 1st side / 2nd side
see last page for connector code
BFC-TREE-14-11-P4-500-1-X1-70/70ordering code example for TREE fused couplermultimode
1N / 2N Broadband Tree Fused Coupler
Multimode
8/9/2019 Passive Components Catalogue
26/39
24
100%
50%
0%
1310 nm 15 1550 nm 15
HUBER+SUHNER FIBER OPTICS
Fused Wavelength Division Multiplexers (WDM)
Singlemode
FeaturesLow excess loss
High isolation
High reliability
Applications1310 nm / 1550 nm simultaneous operation on asingle fiber
Network monitoring
CATV
Access passive optical network
Generic specifications
Parameter Value
Operating wavelength 1310 15 / 1550 15
Directivity 55 dB
Return loss 55 dB
Fiber type ITU-T G.652 SMF
Temperature sensitivity (max.) 0.002 dB/C
Operating temperature 25 to + 70 C
Storage temperature 40 to + 85 C
WDMWavelength Division Multiplexers (WDMs) allow themultiplexing and demultiplexing of two different wave-length with high isolation and low insertion loss.
Performance
8/9/2019 Passive Components Catalogue
27/39
25HUBER+SUHNER FIBER OPTICS
Detail specifications
Parameter Standard High isolation Very high isolation
Version no. 001 002 003
Insertion loss (max.) 0.3 dB 1.0 dB 1.5 dB
Isolation (min.) 17 dB 30 dB 40 dB
PDL(on through channel)
0.15 dB 0.25 dB 0.40 dB
Device packaging, standard
Isolation class Cable/fiber type Package Package dimensions (mm)
Standard bare fiber, 250 m P1 3.0 mm; L = 50 mm
Standard TPE loose tube, 0.9 mm P2 3.0 mm; L = 70 mm
Standard simplex cable, 2.0 mm P3 L = 85 mm; W = 18 mm; H = 7.5 mm
High / very high buffer tube, 0.9 mm P4 L = 100 mm; W = 80 mm; H = 7.5 mm
High / very high simplex cable, 2.0 mm P4 L = 100 mm; W = 80 mm; H = 7.5 mm
Fused Wavelength Division Multiplexers (WDM)
Singlemode
8/9/2019 Passive Components Catalogue
28/39
26 HUBER+SUHNER FIBER OPTICS
Ordering code DescriptionWDM-12 ports
12
01 wavelengths
01 1310 and 1550 nm
P2 package
P1 3.0 mm:L = 50 mm
for 250 m coated fiber /
standard isolation
(without connectors only)
P2 3.0 mm:L = 70 mm
for 0.9 mm TPE loose tube /
standard isolation
P3L = 85 mmW = 18 mmH = 7.5 mm
for 0.9 mm TPE loose tube
and 2.0 mm cable /
standard isolation
P4L = 100 mmW = 80 mmH = 7.5 mm
for 0.9 mm TPE loose tube
and 2.0 mm cable /
high and very high isolation
001 version number
001 standard
002 high isolation
003 very high isolation
1 cable length1 in meters, max. 3 meters
X1 cable type
X0 250 m fiberX0 = available package: P1
(available without connectors only)
X1 0.9 mm tube X1 = available package: P2, P3, P4
X3 2.0 mm cable X3 = available package: P3, P4
70/70 connector code 1st side / 2nd side
see last page for connector code
WDM-12-01-P2-001-1-X1-70/70 ordering code example for fused WDM singlemode
Fused Wavelength Division Multiplexers (WDM)
Singlemode
8/9/2019 Passive Components Catalogue
29/39
27
3.0
mm
50mm
3.0
mm
70mm
85mm
45mm
18mm
14mm
7.5 mm
100m
m
80mm75mm
80mm
7.5 mm
110mm105mm
11 mm
140m
m160m
m
116m
m136m
m
86mm91mm
9.5 mm
P1P2
P3 P4
P5 P6
HUBER+SUHNER FIBER OPTICS
Coupler and WDM Housings
Application: for coupler 12, 22 and standard WDM with 250 mcoated fiber (without connectors only)
Application: coupler, standard WDM with 0.9 mm tube
Application: coupler 12, 22 standard WDM with 2 mm cable Application: coupler 13, 14, 24 WDM high isolation and WDMvery high isolation
Application: coupler 15, 16, 26, 18, 28 Application: coupler 112, 212, 116, 216
8/9/2019 Passive Components Catalogue
30/39
28
35.5 mm
12.7mm
9.3mm
HUBER+SUHNER FIBER OPTICS
Plug Type Attenuator SC
Singlemode
FeaturesPush-pull type
Maximum stability and reliability
Flat spectral response
SC interface according to IEC 61754-4
ApplicationsPassive optical networks (B-PON, G-PON, E-PON)
Multi wavelength systems balancing
Optical power receivers protection
Specifications
Parameter Value singlemode UPC Value singlemode APC Test method
Wavelength bandwidth 1260 nm to 1360 nm and 1460 nm to 1625 nm
Attenuation from 1 to 20 dB, in steps of 1 dB IEC 61300-3-4
Spectral tolerances 15% on nominal attenuation value (att 1 4 dB)
10% on nominal attenuation value (att 5 20 dB)IEC 61300-3-7
Repeatability of IL 0.1 dB over service life
Return loss > 50 dB > 60 dB IEC 61300-3-6
Durability min. 1000 mating cycles
Operating temperature 25C to + 70C
Housing material zinc nickel plated
Housing colour metallic
Ferrule full ceramic
Dimensional drawing
8/9/2019 Passive Components Catalogue
31/39
8/9/2019 Passive Components Catalogue
32/39
30
13.4 mm
(30 mm)4.5 mm
4.5mm 9
.3mm
HUBER+SUHNER FIBER OPTICS
FeaturesLatched push-pull type, small form factor(1.25 mm ferrule)
Maximum stability and reliability
Flat spectral response
LC interface according to IEC 61754-20
ApplicationsPassive optical networks (B-PON, G-PON, E-PON)
Multi wavelength systems balancing
Optical power receivers protection
Specifications
Parameter Value singlemode UPC Value singlemode APC Test method
Wavelength bandwidth 1260 nm to 1360 nm and 1460 nm to 1625 nm
Attenuation from 1 to 20 dB, in steps of 1 dB IEC 61300-3-4
Spectral tolerances 15% on nominal attenuation value (att 1 4 dB)
10% on nominal attenuation value (att 5 20 dB)IEC 61300-3-7
Repeatability of IL 0.1 dB over service life
Return loss > 50 dB > 60 dB IEC 61300-3-6
Durability min. 1000 mating cycles
Operating temperature 25C to + 70C
Housing material plastic material, UL94-V0
Housing colour blue green
Dimensional drawing
Plug Type Attenuator LC
Singlemode
8/9/2019 Passive Components Catalogue
33/39
31HUBER+SUHNER FIBER OPTICS
Attenuator Plug Type
Singlemode
Ordering code DescriptionOFA-FSC connector type
FSC (SC)
FCPC
FLC (LC)
U polishing type
U UPC (RL > 50 dB)
A APC (RL > 60 dB)
020 attenuation
020 2 dB
030 3 dB
040 4 dB
050 5 dB
060 6 dB
080 8 dB
100 10 dB
150 15 dB
200 20 dB
other attenuation values upon request
S tolerancesS 15% (14 dB); 10% (520 dB)
01 wavelength
01 1310 and 1550
001 version number
001 - standard
OFA-FSC-P-020-S-01-001 ordering code example for attenuator "plug type"
8/9/2019 Passive Components Catalogue
34/39
32 HUBER+SUHNER FIBER OPTICS
Inline Attenuator
Singlemode
FeaturesExcellent uniformity
Maximum stability and reliability
Flat spectral response
Low cost / high quality
All current singlemode connectors can beterminated
Applications
Passive optical networks (B-PON, G-PON, E-PON)Telecom, CATV, FTTH
Multi wavelength systems balancing
Optical power receivers protection
Specifications
Parameter Singlemode PC Singlemode UPC Singlemode APC Test method
Wavelength bandwidth 1260 nm to 1360 nm and 1480 nm to 1580 nm
Attenuation from 1 to 30 dB, in steps of 1 dB IEC 61300-3-4
Spectral tolerances 15% on nominal attenuation value (att 1 4 dB)
10% on nominal attenuation value (att 5 20 dB)IEC 61300-3-7
Return loss > 45 dB > 50 dB > 60 dB IEC 61300-3-6
Durability min. 1000 mating cycles
Connector type all singlemode connector types (see last page for connector code)
Cable type LSFH, 2.0 mm, blue
Operating temperature 25C to + 70C
Storage temperature 40C to + 85C
Length tolerancesCable length Tolerance (measured from ferrule tip to ferrule tip)
< 1 m 0 / + 100 mm
1 to 5 m 0 / + 100 mm
5 to 10 m 0 / + 2 %
8/9/2019 Passive Components Catalogue
35/39
33HUBER+SUHNER FIBER OPTICS
Ordering code DescriptionOIA inline attenuator
020 attenuation
020 2 dB
030 3 dB
040 4 dB
050 5 dB
060 6 dB
080 8 dB
100 10 dB
150 15 dB
200 20 dB
300 30 dB
other attenuation values upon request
S tolerances
S 15% (14 dB); 10% (520 dB)
01 wavelength
01 1310 and 1550
001 version number
001 - standard01 cable length
01 in meters, max. 3 meters
X3 cable type
X3 2.0 mm cable
70/70 connector code 1st side / 2nd side
see last page for connector code
OIA-020-S-01-001-01-X3-70/70 ordering code example for inline attenuator singlemode
Inline Attenuator
Singlemode
8/9/2019 Passive Components Catalogue
36/39
34 HUBER+SUHNER FIBER OPTICS
Connectorcode type
00 no connector
20 ST-HQ
22 ST-Security
24 ST-LEAN
30 FCPC
33 FCPC APC wide key
34 FCPC APC small key
40 LSA
43 LSA APC
45 MU
Connectorcode type
70 SC
73 SC APC 8
74 SC APC 9
80 LX.5
83 LX.5 APC
85 LC
86 LC APC
90 LSH (E-2000)
93 LSH (E-2000) APC
Connector Code
8/9/2019 Passive Components Catalogue
37/39
35HUBER+SUHNER FIBER OPTICS
Notes
8/9/2019 Passive Components Catalogue
38/39
36 HUBER+SUHNER FIBER OPTICS
Notes
8/9/2019 Passive Components Catalogue
39/39
08
HUBER+SUHNER Excellence in Connectivity Solutions
HUBER+SUHNER is a leading global supplier of components
and systems for electrical and optical connectivity incommunications, industrial and trans portation markets.
HUBER+SUHNER can draw on core competences in the
areas of high frequency technology, fibre optics, cables and
polymers. Working in close collaboration with our customersaround the globe, we strive for excellence in the development
and manufacturing of high quality products.
MMUNICATION INDUSTRYTRANSPORTATION
mmunication Networks/Communication Equipment Railway/Automotive Instrumentation/Space+Defence/Industrial Wiring
HUBER+SUHNER AGRF Technology
HUBER+SUHNER is certified according toISO 9001 and ISO 14001.