Particle Size & Shape Analyzer
Table of Content
Laser Channel ..….………. 3-7
Video Channel ..…....…. 8-15
General Application ....16-17
S/W Features …………. 18-29
Summery …..………..…….. 30
Slide 2/30
DIPA-2000 Measuring Channels
Single Instrument ; Dual Measurement Channels
Slide 3/30
DIPA-2000 Laser Channel
Main Advantages:
Quick & Straight Forward Measurement
High Resolution Detection Capabilities
Time Domain Analysis, No “Pre-Knowledge”
Slide 4/30
The rotating laser beam scans single particles within its focus.
The diameter of the particle is directly correlated to the duration of the obscuration.
The measurement principle is a time interval, not an intensity measurement.
The time domain is independent of particles optical or physical properties.
DIPA-2000 Laser Channel
A B C D E F
Ta Tb Tc Td Te TfTime
V
Scanning Laser
Slide 5/30
From the duration of the obscuration (T),
and the known rotation velocity of the laser beam (V),
the particle diameter (D)
can be calculated:
D = V · TIn relation to the high speed of the laser rotating laser, the particles
are stationary, thus will not effect particle size measurement.
No requirements for particles pre-knowledge of:
1. Refractive index
2. Temperature
3. Viscosity variation
4. Electrical conductivity
5. Etc…
DIPA-2000 Laser Channel
Slide 6/30
Data is collected directly on each analyzed particle.
Detection of minor fractions, high resolution.
Correct measurement of particle size, not influenced by physical or optical properties.
Operation in Liquid, Dry and Aerosol mediums.
No calibration/alignment required by user.
Robust measurement, on-line indication for statistical significance.
Concentration measurement.
FDA 21 CFR Part 11 S/W security compliance.
DIPA-2000 Laser ChannelSummery
Slide 7/30
DIPA-2000 Video Channel
Main Advantages:
Sample Visualization
Dynamic Shape Analysis
Advanced Particles Size and Shape information
Slide 8/30
Dynamic Shape Analysis(DSA) Principle of Operation
Real time images of particles in motionare collected
Images are converted into a grid containing a collection of picture elements (pixels)
Each individual pixel has a value for brightness (grey level): 0 = Dark; 255 = White
All images are analyzed according to apre-defined set of Image Analysis characteristics
Measurement is finished when the analysis end conditions are met (# of particles/images, confidence level, time, etc)
420 µm
18 µm
Image Conversion
Slide 9/30
DIPA-2000 DSA Main Features:
• Easy setup and measurement using software wizards
• Advanced pre-processing algorithms
• Size and Shape Filter/Grouping
• Automated Report Generation
• Storage of real raw date (un-processed images)
• Re-processing of raw data
• Internal optical calibration and verification tools available
• Interface with 3rd party hardware (Microscopy)
DIPA-2000 Video Channel
Slide 10/30
• For each individual particle, all size and shape parameters are determined.
• The DIPA-2000 Image Analysis S/W automates set-up and measurement.
• DIPA-2000 IA software includes many procedures such as:
– Pre-Processing Procedures– Image Quality Filters– Region of Interest Determination– Out-Of-Focus Rejection– Morphology Operations– Grouping according to size/shape– Re-Processing of stored images and
movies– Manual Lens Calibration (Microscopy)
DIPA-2000 Video Channel
Slide 11/30
Image quality can be improved using automatic pre-processing procedures, such as “Contrast Enhancement”
Contrast Enhancement increases the number of gray levels
DIPA-2000 Video ChannelPre-Processing
Slide 12/30
• Shape Filters can be set up to analyze a specific group of particles based on size and/or shape characterization
• Some Known Applications:
• Fiber Analysis
• Shape of Sieve Fraction
• Abrasives
• Oil-In-Water
• Minor fraction in Matrix
• And many more…
All Particles:
Shape Factor < 0,8:
Shape Filter
Average Size of non-sphericalparticles in sample
DIPA-2000 Video ChannelGrouping / Shape Filters
Slide 13/30
• The complete shape information for every particle is saved in the object data base.• For each Particle all data analysis results can be viewed individually.
DIPA-2000 Video ChannelObject Data-Base
Slide 14/30
Seeing is believing, visualize your sampled particles.
Better and advanced characterization of materials.
High resolution data (down to pixel size data).
Detection and quantification of shape parameters.
Validation technique for the Laser Channel or other particlesize methods.
Detection capability of minor fractions for fine particles oragglomerated materials.
Quantification of material homogenity.
Advanced tool for shape differences characterisation.
FDA 21 CFR Part 11 S/W security compliance.
DIPA-2000 Video ChannelSummery
Slide 15/30
One System = Variety of Applications
MagneticStirring
FiberCell
FreeFall
LiquidFlow (10mm)
SlideCell
LiquidFlow (4mm)
HeatedCell
MechanicalStirring
AerosolFlow
MicroFlow
“Adapting the technology to the application”, rather than -“adapting the application to the technology”
Slide 16/30
Life Science
Heavy Industry
Food Products
Energy
Ceramics & Metals
Chemicals
Pharma/Bio-Tech
Environmental
Geology Soil, clay, sand, kaolin
Ocean water, tap water, waste water, membrane filtration, dust, flocculation
Powders, suspensions, syrups, emulsions, pastes, micro-carriers, injectable solutions, collagen, microcapsules
Pesticides, dispersants, catalysts, resins, emulsions,
preservatives
Alumina, silica, magnetic powders, tungsten, strontium,
sintered products, stainless steel, cobalt
Coal, fuels, slurries, shale-oil emulsions, fly ash
Emulsions, fine powders, beer, coffee, chocolate, flour,
ground products, agglomerated crystals, peanut butter
Polymers, oil droplets, wear particles, calk, fillers, toners,
pulp & paper, coatings, pigments, PVC, paint
Bacteria, smears, inhalation toxicology, cell research,
algae growth, yeast, blood analysis
Some Global ApplicationsSlide 17/30
DIPA 2000 Particle Size & Shape
Analyzer
Elementary and Advanced S/W Features
Slide 18/30
Slide 19/30
Slide 20/30
Slide 21/30
Slide 22/30
Slide 23/30
Slide 24/30
Slide 25/30
Slide 26/30
Slide 27/30
Slide 28/30
Slide 29/30
DIPA 2000 S/W FeaturesSummery
• Easy setup and measurement using software wizards
• Advanced pre-processing algorithmes
• Size and Shape Grouping/Filtering
• Automated report generator
• Storage of real-time raw data (un-processed images)
• Re-processing of raw data (images & movie files)
• Interface with 3rd party hardware (e.g. Microscopy)
• Manual calibration and verification tools avaible
• Integrated laser and video software
• Simultaneous laser and video results
• FDA 21 CFR Part 11 S/W security compliance