Page 1 2012/8/2 MOLDFLOW ANALYSIS REPORT Part Name : Body Lower+Upper Report Date : 2012/8/2

Part Name : Body Lower+Upper Report Date : 2012/8/2

  • Upload
    fergal

  • View
    30

  • Download
    4

Embed Size (px)

DESCRIPTION

Part Name : Body Lower+Upper Report Date : 2012/8/2. Material introduction. PC Makrolon 2607 Bayer MaterialScience. MFR:13 g/10 min. Analysis Indication. The distribution of thickness for this part is regular. The Fusion mesh is adopted for Moldflow CAE analysis model. - PowerPoint PPT Presentation

Citation preview

Page 1: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 1 2012/8/2

MOLDFLOW ANALYSIS REPORT

Part Name : Body Lower+Upper

Report Date : 2012/8/2

Page 2: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 2 2012/8/2

MOLDFLOW ANALYSIS REPORT

Material introduction

PC Makrolon 2607 Bayer MaterialScience

MFR:13 g/10 min

Page 3: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 3 2012/8/2

MOLDFLOW ANALYSIS REPORT

The distribution of thickness for this part is regular.

The Fusion mesh is adopted for Moldflow CAE analysis

model.

Analysis Indication

Page 4: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 4 2012/8/2

MOLDFLOW ANALYSIS REPORT

Feed System Design

Layout:1 + 1

Sub gate:Ø2.0 mm

Page 5: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 5 2012/8/2

MOLDFLOW ANALYSIS REPORT

Cooling System Design

Same as the 2D mold drawing.

Page 6: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 6 2012/8/2

MOLDFLOW ANALYSIS REPORT

Melt temperature: 300.00 deg.C

Processing Conditions

Filling Conditions:

Cooling Conditions:

Coolant inlet temperature: 90.00 deg.C

Pressure(压力 ) [MPa] Duration(时间 ) [Second]

75 10

Holding Setting( 保 压 设定 ):

Page 7: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 7 2012/8/2

MOLDFLOW ANALYSIS REPORT

Fill TimeFill Time

Fill time is 1.7 sec.

Page 8: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 8 2012/8/2

MOLDFLOW ANALYSIS REPORT

Fill TimeFill Time

Shift+F5

Play this report file to view filling animation.

Page 9: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 9 2012/8/2

MOLDFLOW ANALYSIS REPORT

Injection PressureInjection Pressure

Left plot is the pressure distribution at the time of 99% filled(V/P switch over).

The max. pressure is 124.6 MPa.

Page 10: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 10 2012/8/2

MOLDFLOW ANALYSIS REPORT

Clamp Clamp ForceForce

Clamp Force(锁模力 )=80~100 Ton

Higher hold pressures will increase the clamp force requirement.(保压压力越大 ,

锁模力越大)

Page 11: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 11 2012/8/2

MOLDFLOW ANALYSIS REPORT

Weld LinesWeld Lines

No weld line

Page 12: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 12 2012/8/2

MOLDFLOW ANALYSIS REPORT

Air trapAir trap

The locations of air traps are shown as small pink balls.

Page 13: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 13 2012/8/2

MOLDFLOW ANALYSIS REPORT

Air trapAir trap

The locations of air traps are shown as small pink balls.

Page 14: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 14 2012/8/2

MOLDFLOW ANALYSIS REPORT

Coolant TemperatureCoolant Temperature

The change in coolant temperature from coolant-in to coolant-out is not mare than 3°C .

Page 15: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 15 2012/8/2

MOLDFLOW ANALYSIS REPORT

Mold TempMold Temp

The mold temperature is uniform in the cavity.

定模温度均匀 .

Page 16: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 16 2012/8/2

MOLDFLOW ANALYSIS REPORT

Mold TempMold Temp

The mold temperature is uniform in the core.

动模温度均匀 .

Page 17: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 17 2012/8/2

MOLDFLOW ANALYSIS REPORT

Time to Reach Ejection TemperatureTime to Reach Ejection Temperature

The acceptable range of time to reach eject-ion temperature for parts is 44~55 sec.

Sink mark in the marked regions.

Page 18: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 18 2012/8/2

MOLDFLOW ANALYSIS REPORT

Time to Reach Ejection TemperatureTime to Reach Ejection Temperature

Freeze time for gate is 10 sec.

浇口凝固时间为 10秒 .

Page 19: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 19 2012/8/2

MOLDFLOW ANALYSIS REPORT

X DeflectionX Deflection

X

The shrinkage is uniform in X direction.

Page 20: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 20 2012/8/2

MOLDFLOW ANALYSIS REPORT

Y DeflectionY Deflection

Y

The shrinkage is uniform in Y direction.

Page 21: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 21 2012/8/2

MOLDFLOW ANALYSIS REPORT

Z DeflectionZ Deflection

Z

0.13

0.09

0.10.15

Page 22: Part Name :   Body Lower+Upper Report Date :   2012/8/2

Page 22 2012/8/2

MOLDFLOW ANALYSIS REPORT

Summary

Note:

The report is based on the analysis results of Moldflow Plastics Insight software. Please use this report for reference only.

Flow Results(流动结果) Refer to page

Short shot (不饱模 ) No

Unbalanced Filling (流动不平衡 ) No

Injection pressure is high (注射压力偏高 ) No

Weld line on main surface (主面有熔接线 ) No

Air trap(困气 )) No

Cool Results(冷却结果)Uniform mold temperature (模温均匀 ) Yes

Freeze time for part to ejection (产品凝固时间 ) 44~55 Sec 17

Sink mark (缩水 ) Yes 17

Freeze time for gate (浇口凝固时间 ) 10 18

Freeze time for runner is longer than that of part (流道凝固时间比产品长 ) No

Warp Results(变形结果)Some degree of deflection (有一定变形 ) No