part list for REZNOR

Embed Size (px)

DESCRIPTION

replacement parts for reznor duct furnaces

Citation preview

  • Form RZ-NA-P-EEDU, Page 1

    REFERENCES:

    Replacement Parts/Service FormsForm P-PILOTS, Replacement Pilots*Form P-T'Stats, Replacement Thermostats & Accessories*Form P-GC, Gas Conversion Components and InstructionsForm P-FAN&LIMIT, Replacement Fan and Limit controls*Form P-VALVES, Replacement Valves, Electronic Gas

    Controls, and Maxitrol Gas Control Systems*Form CP19, Ignition Conversion (G60PFH-2 to

    G770NGC-4) Components and InstructionsForm CP-EEDU-PSK - Replacement Pressure Switch Kit

    Installation/Operation Form:Installation/Operation Manual, Form I-EEDU

    WEBSITE (all forms may be downloaded from Website):www.RezSpec.com

    *These items are not in this book.

    IMPORTANT1. Always include complete heater model and serial number so that

    any specification change can be considered for parts shipment. Itcan save time and expense.

    2. Specifications are subject to change without notice.3. We reserve the right to substitute functional replacements.4. Order by Part No.; not Heater Option Designation.

    Replacement Parts forModel EEDU and HEEDU

    Duct FurnacesPARTS Form P-EEDU

    Obsoletes Form 735 (Version A)

    Example of a Rating PlateThe rating plate is located on the cover of the electrical junction box.Find the serial number on the heater rating plate. See page 2 to decodethe serial number and model number.

    Key to Duct Furnace Rating PlateA = StandardB = Model and SizeC = Date of ManufacturerD = Serial No.E = Volts/PH/Hz/AmpsF & G = Natural or Propane GasH & I = AltitudeJ = Orifice Drill SizeK = Normal Input (altitude

    adjusted)L = Thermal Output (altitude

    adjusted)

    M = Minimum Input (altitudeadjusted)

    N = Normal Manifold PressureO = Minimum Gas Supply

    PressureP = Maximum Air ThroughputQ = Minimum Air ThroughputR = Normal Input (sea level)S = Thermal Output (sea level)T = Minimum Input (sea level)

    Replacement Parts TagEach unit has a replacement parts tag that includes theModel No. and the Serial No. as well as a list of originalcommon replacement parts. Always provide the full modeland serial numbers when ordering replacement parts.

    Index Description Page No.Burner Orifices 6Burner Rack and Components 6Cabinet Parts 3Condensate Drain Kit 3Coupling Kits 3Ductstat 8Fan Control 8Flue Collection Box 4Hanger Kit 3Heat Exchanger and Components 5Heat Exchanger Baffles 5Ignition Controller 7Limit Control 5Manifold 6Pilot 7Pressure Switch 4Relay 4Replacement Parts Tag 2Serial No. and Rating Plate 1Transformer 8

    REZNORMERCER, PA. USA 16137

    DUCT FURNACECATEGORY IIIFOR INDUSTRIAL/COMMERCIAL USE ONLYANSI Z83.8 [ AA ] - [ A ] CSA 2.6 [ AA' ] - [ A' ] DUCT FURNACEMODEL [ B ] [ C ]SERIAL NO. [ D ][ E ] VOLTS [ E ] PH [ E ] HZ MAXIMUM TOTAL INPUT [ E ] AMPSTYPE OF GAS: [ F ] [ G ]ORIFICE SIZE [ J ] DRILL HAS BEEN FACTORY ADJUSTEDFOR USE AT [ H ] FEET [ I ] METERS OF ALTITUDE.

    ALT. ADJUSTEDNORMAL INPUT [ K ]BTU/HR.OUTPUT CAPACITY [ L ]BTU/HR.MINIMUM INPUT(2,M,MV MODELS) [ M ]BTU/HR.NORMAL MANIFOLD PRESSURE [ N ] IN.W.C.MIN. PERMISSIBLE GAS SUPPLY PRESSURE FOR PURPOSE OF INPUT ADJUSTMENT. [ O ] IN.W.C.MAXIMUM THROUGHPUT [ P ] C.F.M.MINIMUM THROUGHPUT [ Q ] C.F.M.

    CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP- 6" , FLUECONNECTION-6", LEFT SIDE-12", RIGHT SIDE- 12", BOTTOM- 12"THIS UNIT MAY BE INSTALLED ON NONCOMBUSTIBLE FLOORS.THIS UNIT SHALL BE INSTALLED ON THE POSITIVE PRESSURE SIDE OF THEAIR CIRCULATING BLOWER.THIS UNIT MAY BE INSTALLED DOWNSTREAM FROM A REFRIGERATIONSYSTEM (USE DRAIN OPTION CS1).FOR ALTERNATE INSTALLATIONS USE THE LATEST EDITIONS OF THEAPPROPRIATE STANDARD LISTED BELOW:FOR AIRCRAFT HANGERS USE STANDARD ANSI/NFPA 409FOR PARKING STRUCTURES USE STANDARD ANSI/NFPA 88AFOR REPAIR GARAGES USE STANDARD ANSI/NFPA 88B

    SEA LEVEL[ R ][ S ][ T ]

  • Form RZ-NA-P-EEDU, Page 2

    Model No. DecodingThe Model No. consists of the Example:

    Model Designation HEEDU Size 400 Series No. -6

    The Series No. which changes when the product line is re-certified (see chart below) is important in the selection ofcertain replacement parts.Suffixes to the Model No.

    2 = Two Stage ValveH = High Altitude OrificesMV = Electronic ModulationS = Stainless Steel Heat Exchanger

    De-Coding a Serial No.Sample: S AZJ 66 K8 N 12345 MV3

    1 | 2 | 3 | 4 | 5 | 6 | 71 = Stainless steel heat exchanger (with an aluminized

    heat exchanger, there is no letter suffix)2 = Date code (see below)3 = Pilot code (Reference Form P-VALVES)4 = Valve code (Reference Form P-VALVES)5 = N is natural gas; L is propane gas6 = Consecutive number7 = Maxitrol system (optional)

    Introduction and Recertification Dates

    Date of Manufacture - First Element of the Serial NumberYear Jan Feb Mar Apr May June July Aug Sept Oct Nov Dec1981 AGA AGB AGC AGD AGE AGF AGG AGH AGI AGJ AGK AGL1982 AHA AHB AHC AHD AHE AHF AHG AHH AHI AHJ AHK AHL1983 AIA AIB AIC AID AIE AIF AIG AIH AII AIJ AIK AIL1984 AJA AJB AJC AJD AJE AJF AJG AJH AJI AJJ AJK AJL1985 AKA AKB AKC AKD AKE AKF AKG AKH AKI AKJ AKK AKL1986 ALA ALB ALC ALD ALE ALF ALG ALH ALI ALJ ALK ALL1987 AMA AMB AMC AMD AME AMF AMG AMH AMI AMJ AMK AML1988 ANA ANB ANC AND ANE ANF ANG ANH ANI ANJ ANK ANL1989 AOA AOB AOC AOD AOE AOE AOG AOH AOI AOJ AOK AOL1990 APA APB APC APD APE APF APG APH API APJ APK APL1991 AQA AQB AQC AQD AQE AQF AQG AQH AQI AQJ AQK AQL1992 ARA ARB ARC ARD ARE ARF ARG ARH ARI ARJ ARK ARL1993 ASA ASB ASC ASD ASE ASF ASG ASH ASI ASJ ASK ASL1994 ATA ATB ATC ATD ATE ATF ATG ATH ATI ATJ ATK ATL1995 AUA AUB AUC AUD AUE AUF AUG AUH AUI AUJ AUK AUL1996 AVA AVB AVC AVD AVE AVF AVG AVH AVI AVJ AVK AVL1997 AWA AWB AWC AWD AWE AWF AWG AWH AWI AWJ AWK AWL1998 AXA AXB AXC AXD AXE AXF AXG AXH AXI AXJ AXK AXL1999 AYA AYB AYC AYD AYE AYF AYG AYH AYI AYJ AYK AYL2000 AZA AZB AZC AZD AZE AZF AZG AZH AZI AZJ AZK AZL2001 BAA BAB BAC BAD BAE BAF BAG BAH BAI BAJ BAK BAL2002 BBA BBB BBC BBD BBE BBF BBG BBH BBI BBJ BBK BBL2003 BCA BCB BCC BCD BCE BCF BCG BCH BCI BCJ BCK BCL2004 BDA BDB` BDC BDD BDE BDF BDG BDH BDI BDJ BDK BDL2005 BEA BEB BEC BED BEE BEF BEG BEH BEI BEJ BEK BEL2006 BFA BFB BFC BFD BFE BFF BFG BFH BFI BFJ BFK BFL2007 BGA BGB BGC BGD BGE BGF BGG BGH BGI BGJ BGK BGL2008 BHA BHB BHC BHD BHE BHF BHG BHH BHI BHJ BHK BHL2009 BIA BIB BIC BID BIE BIF BIG BIH BII BIJ BIK BIL2010 BJA BJB BJC BJD BJE BJF BJG BJH BJI BJJ BJK BJL2011 BKA BKB BKC BKD BKE BKF BKG BKH BKI BKJ BKK BKL2012 BLA BLB BLC BLD BLE BLF BLG BLH BLI BLJ BLK BLL2013 BMA BMB BMC BMD BME BMF BMG BMH BMI BMJ BMK BML2014 BNA BNB BNC BND BNE BNF BNG BNH BNI BNJ BNK BNL2015 BOA BOB BOC BOD BOE BOF BOG BOH BOI BOJ BOK BOL

    Certification Series (see Model No. above) DateIntroduction (no series no.) AGE (5/81)

    3 AMI (9/87)6 AUK (11/95)

    Introduction (no series no.) AGE (5/81)3 AMI (9/87)5 AQK (11/91)6 AUK (11/95)

    For installation in the United States

    For installation in Canada

  • Form RZ-NA-P-EEDU, Page 3

    Cabinet Parts, Hanger Kit, Condensate Drain, and Coupling Kits

    !"#$

    %!&'($

    )*

    +##*''

    Terminate drain outside of the building.

    Condensate Drain Kit, P/N 31765(Same as Option CS1)

    Hanger Kit, P/N 57959, Four ThreadedSockets(Same as Option CK3)

    SocketAssemblyonly,P/N 9557

    , -&"

    ,. ""&"

    /

    01

    2

    %

    Cabinet Parts

    Coupling Kits for 2, 3, 4, or 5 Furnaces

    Coupling Kit, P/N 57963 (Same as Op tion CR1), for Two Furnaces

    Item Qty P/N DescriptionA 2 57964 Filler Plate B 1 57965 Tie Plate C 2 9557 Threaded Socket

    AssemblyD 2 5095 3/8-16 x 1-1/4" lg Hex

    Head BoltsE 2 5197 Split Ring Lock Washer

    F 20 11813 #10 x 1/2" lg Sheetmetal Screws

    Additional Kits:3 Furnaces - P/N 82854 (Op tion CR2)4 Furnaces - P/N 82855 (Op tion CR3)5 Furnaces - P/N 82856 (Op tion CR4)

    Cod

    e

    Description 75 100 125 140 170 200 225 250 300 350 400

    1 Bottom Pan Aluminized Steel 85985 85986 85987 85988 85989 85990 85991Stainless Steel 86052 86053 86054 86055 86056 86057 86058

    2 Left Side Panel Assy Prior to Series 6 64689(includes insulation) Beginning with Series 6 142099

    3 Right Side Panel Assy Prior to Series 6 64691(includes insulation) Beginning with Series 6 142100

    4 Bottom Front Panel (Size 75 includes insulation) 64692 55378 55392 55398 55404 55410 55422 55434 554445 Bottom Stiffening Channel 55393 55399 55405 55411 55423 55435 554456 Burner Panel 55508 55509 55510 55511 55512 55513 555147 Bottom Rear Channel N/A N/A N/A N/A 65074 65075 65076 65077 65078 65079 650808 Rear Cover Plate (aka Prior to Series 6

    Ignition Plate Assy) Beginning with Series 69 Inner Bottom Panel - Size 75 only 64694 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

    ("false bottom" - not illustrated)

    99125

    63162 45737142053 142054

    55379 5538755506 55507

    Painted Side Panel (not illustrated) - Same as panels in Option AZ9

    85983 8598486050 86051

    5537314208055375

    14208155386

  • Form RZ-NA-P-EEDU, Page 4

    Flue Collection and Venter AssemblyCode 18A,Capacitor,P/N 163894

    Code 21, Venter Relay,P/N 14747, RBM 84-20102-01, SPST

    Code 27 - Vent Cap

    /

    3

    01

    %

    %

    2.

    2

    Cod

    e

    Description 75 100 125 140 170 200 225 250 300 350 400

    10 Flue Collection Prior to Series 6 61024 61028 61030 61033 61036 61039 61042 61045 61048Box Assembly Beginning Series 6 140898 140899 140900 140901 140902 140903 140904 140905 140906

    11 Venter Support Angle/Duct Support12 Orifice Plate 63167 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A13 Exhaust Collar and Prior to Series 6

    Pipe Assembly Beginning Series 6 61054 143183 14318414 Venter Support Plate N/A N/A N/A

    15A Blower Housing (includes housing & collars)15B Cover Plate16 Venter Wheel, 5/16" bore

    Torrington AA326-215-1 Torrington AA408-228-117 Venter Fan Blade RHF

    18A Capacitor N/A N/A N/A N/A N/A N/A N/A N/A 163894 (replaces 103181)18B Capacitor Boot, Syntex #M-78 N/A N/A N/A N/A N/A N/A N/A N/A19 Venter Junction Box Mounting Bracket20 Venter Junction Box21 Relay, RBM #84-20102-10122 Venter Junction Box Cover23 Switch Bracket24 Pressure Switch IS20232-5272 (black plastic) 205821 (to replace metal pressure switch used prior to 9/2003, or kit P/N 177633)25 Pressure Switch Tubing, Silicone 177293, 8-1/4"26 Fuse 1.6 Amps (C.G.A. prior to 10/89 only)27 Vent Terminal Cap28 Venter Motor 115 volt

    Fasco 7121-4861 Fasco 7162-1775208 volt 30249 (replaces 62814, 208/230V motor)

    Fasco 7162-0186 Fasco 7162-0186230 volt 29571 (replaces 62814, 208/230V motor)

    Fasco 7162-0158 Fasco 7162-0158Venter Motor and Wheel 115 voltAssembly (including Codes 208 volt16, 17, 19, 20, 22, 23, & 28) 230 voltVenter Sub-Assembly 115 volt(complete including Codes 208 voltabove plus 15A&B) 230 volt

    65396 65397 6539865396 65397 65401

    64858 6486365146 65149 65152

    63169 6317464858 64859

    61069 87434

    30249

    29571

    61541110051, 4" 110052, 5" 110053, 6"

    10318231394

    1474729596

    29595

    61075

    29791 29792

    29793

    29597

    63179

    6105161051

    61054 6788067880

    147904, 7"

    63164140907

    63178

    63110 6254561064 61072

    61070

    29594

  • Form RZ-NA-P-EEDU, Page 5

    %1%0

    %1

    %

    %

    %

    %

    %0% 3

    %

    %%

    Limit Control (Code 35) on Bracket(Code 34) is accessible from "inside"or "outside" the furnace

    OutsideInside

    Beginningwith Series 6,"V-shaped"tube baffles(Code 38) fitin betweenthe top of theheatexchangertubes inSizes 140-400

    38

    Heat Exchanger and Components

    ."4

    .4

    4

    54

    .

    ."4

    54

    Code 40 - Model EEDU only Code 40 -- Heat Exchanger Baffle AssemblyAll Model EEDU units are equipped with a heat exchanger directional air baffle assembly asillustrated.When replacing a heat exchanger, check to see if the baffle assembly can be salvaged. If the baffleassembly cannot be salvaged, it will be neces-sary to order and install a replacement. Theheat exchanger baffle assembly (Code 40) forModel EEDU furnaces includes Codes 40A, B,C, D, E, F.Model HEEDU units are equipped with only arear top baffle support (Code 40E) and a reartop baffle (Code 40F). If these parts cannot besalvaged, order and install replacements.These parts cannot be installed in the replace-ment heat exchanger at the factory. They mustbe ordered separately and installed in thefield.

    HeatExchangerBaffle inModelHEEDU

    Code 35 -LimitControl

    Code Description (Qty*) 75 100 125 140 170 200 225 250 300 350 40029 Heat Aluminized Steel 65096 65097 65098 65099 65100 65101 65102

    Exchanger 321 Stainless Steel 59186 59192 59198 59204 59210 59216 59222409 Stainless Steel 59144 59147 59150 59153 59156 59159 59162

    30 Burner Angle31 Rear Burner Support 45639 45646 45653 45660 45667 45674 4568132 Hanger Support Angle33 Baffle 46218 46219 46220 46221 46222 46223 4622434 Limit Control Bracket35 Limit Control 36T2136 Side Gasket Strip Craneglas37 Front and Rear Gasket Strip (2) 62923 62924 62925 62926 62927 62929 6293138 Tube Baffles Beginning with Series 6

    (None prior to Series 6) (5) (6) (7) (8) (8) (11) (13) (15)40 Heat Exchanger Baffle Assembly EEDU only 55519 55096 55520 55097 55539 55540 55541

    40A Baffle Support Bracket(2) (2) (2) (2) (2) (2) (2) (2) (4) (4) (4)

    40B Bottom Baffle Support 52497 46489 52498 46494 52499 52500 5250140C Finger Baffle

    (3) (3) (4) (4) (5) (6) (7) (8) (10) (12) (14)40D Side Finger Baffle 40E Rear Top Baffle Support 55105 55106 55107 55108 55109 55111 5511340F Rear Top Baffle 55118 55119 55120 55121 55122 55124 55126*Quantity other than one is in parenthesis; a quantity at the beginning of the row applies to all sizes.

    EEDU and HEEDU

    (2) 551285510355116

    5510455117

    62921 6292285727

    55094 55095

    -- -- --

    45602, 180F(2) 62933

    85449, 200F

    (2) 5550554420 46217

    63175

    59137 59141( 2) 55452

    54419 45632

    65094 6509559174 59180

    EEDU only

    55101

    46478 4648445399

  • Form RZ-NA-P-EEDU, Page 6

    Burner Rack and Components

    Code 48 -Burneronly

    Code 43 -Burner Rack

    Orifice

    Code 47 --Manifold withOrifices(Code 46 lessOrifices)

    BurnerAir

    Shutters

    Cod

    e

    Description 75 100 125 140 170 200 225 250 300 350 400

    43 Burner Rack Aluminized Steel Prior to 81065 81066 81067 81068 81069 81070 81071with shutters Stainless Steel Series 6 81054 81055 81056 81057 81058 81059 81060Burner Rack Aluminized Steel Beginning with 150443 150444 150445 150446 150447 150448 150449 150450 150451 150452 150453with shutters Stainless Steel Series 6 150454 150455 150456 150457 150458 150459 150460 150461 150462 150463 150464

    46 Manifold (less orifices) 84766 84767 84768 84770 84771 84772 8477347 Manifold with Natural Gas Orifices (sea level) 80922 80923 47224 47225 47226 47227 47228 47229 47230 47231 47232

    Manifold with Propane Gas Orifices (sea level) 80924 80925 65207 65208 65209 65210 65211 65212 65213 65214 6521548 Burner only (Qty) (4) (4) (5) (5) (6) (7) (8) (9) (11) (13) (15)

    Aluminized SteelStainless Steel

    49 Carryover Assembly Prior to Series 6, 63134 63138 N/A N/A N/A N/A N/ARight Carryover Assembly qty was 1; N/A N/A N/A N/A N/A N/A 63141 63148 63152 63148 63152Left Carryover Assembly beginning with N/A N/A N/A N/A N/A N/ACenter Carryover Assembly Series 6, qty is 2. N/A N/A N/A N/A N/A N/A N/A N/A N/A

    50 Burner Air Shutter Assembly 46107 46109 46113 46115 46117 46119 46121 46123 4612551 Burner Air Shutter Guide 165686 165687 165688 165689 165690 165691 16569252 Burner Orifice (Qty) (4) (4) (5) (5) (6) (7) (8) (9) (11) (13) (15)

    Natural Gas P/N 38678Sea Level Size #45 #41 #41 #38 #38 #38 #38 #39 #39 #39 #39Propane Gas P/N 63003Sea Level Size 1.2mm 1.45mm 1.45mm 1.55mm 1.55mm 1.55mm 1.55mm 1.55mm #53 #53 #53Natural Gas P/N 848532001-4500 ft Size #47 #42 #42 #41 #41 #41 #41 #41 #41 #41 #41Propane Gas P/N 639222001-4500 ft Size 1.15mm #54 #54 1.45mm 1.45mm 1.45mm 1.45mm 1.45mm #54 #54 #54Natural Gas P/N 165902001-3000 ft Size #46 #42 #42 #39 #39 #39 #39 #40 #40 #40 #40Propane Gas P/N 396582001-3000 ft Size #56 #54 #54 #53 #53 #53 #53 #53 #54 #54 #54Natural Gas P/N 848533001-4000 ft Size #47 #42 #42 #40 #40 #40 #40 #41 #41 #41 #41Propane Gas P/N 639223001-4000 ft Size 1.15mm #54 #54 #53 #53 #53 #53 #53 #54 #54 #54Natural Gas P/N 848534001-5000 ft Size #47 #42 #42 #41 #41 #41 #41 #41 #41 #41 #41Propane Gas P/N 639224001-5000 ft Size 1.15mm #54 #54 1.45mm 1.45mm 1.45mm 1.45mm 1.45mm #54 #54 #54Natural Gas P/N 848535001-6000 ft Size #47 #43 #43 #41 #41 #41 #41 #42 #42 #42 #42Propane Gas P/N 639225001-6000 ft Size 1.15mm 1.35mm 1.35mm 1.45mm 1.45mm 1.45mm 1.45mm 1.45mm #54 #54 #54Natural Gas P/N 404146001-7000 ft Size #48 #43 #43 #42 #42 #42 #42 #42 #42 #42 #42Propane Gas P/N 404166001-7000 ft Size #57 1.35mm 1.35mm 1.45mm 1.45mm 1.45mm 1.45mm 1.45mm #54 #54 #54Natural Gas P/N 404147001-8000 ft Size #48 #44 #44 #42 #42 #42 #42 #43 #43 #43 #43Propane Gas P/N 404167001-8000 ft Size #57 #55 #55 #54 #54 #54 #54 #54 #54 #54 #54Natural Gas P/N 396518001-9000 ft Size #49 #44 #44 #43 #43 #43 #43 #43 #43 #43 #43Propane Gas P/N 404168001-9000 ft Size #57 #55 #55 #54 #54 #54 #54 #54 #55 #55 #55

    U.S. and Canada

    Canada

    United States

    84764

    11792

    84437

    84437

    84437

    84437

    11828

    84765

    81063 8106481052 81053

    63144

    8521887954

    63128 63131

    6315655552

    165684 165685

    45870 45871

    61652 61653 9789

    11792

    11834 61652 11834

    45871 87391

    11834 9789 11834

    87391 11792

    11834 9789 11834

    11792

    11834 61652 11834

    11792 84437

    97360

    84437

    61652 11834

    97360

    11828

    61652 11834

    11833 84437 11828

    11830 11834

    11833 11828

    11830 11834 11830

  • Form RZ-NA-P-EEDU, Page 7

    Step 4 - Attachterminal to IgnitionController ModelG60 or G67BG/NG-2

    Steps 2 & 3 -Attach 90 Crimp-on Terminal

    Step 1 - SlipBoot over end ofwire

    Horizontal Spark Pilot - Prior to Series 6

    P/N 110861 - Complete Replacement Pilot Kitfor Horizontal, Natural Gas, Spark PilotP/N 110862 - Complete Replacement Pilot Kitfor Horizontal, Propane Gas, Spark Pilot

    Instructions for connecting ignitor lead in replacement spark pilots above to Model G60 or G67BG/NG-2 Ignition Controllers (Not applicable to ignition controllers G67BG-5 or G770NGC-4; Items59 and 60 are not used when installing replacement pilot on heaters with these controllers.):1. Identify the ignitor wire attached to the pilot electrode. Slip the 90 protective boot on to the wire as

    illustrated.2. On the "open" leg of the 90 crimp-on terminal (P/N 112647), locate a flat, triangular spike tab pre-

    punched in the metal. With the tip of a small, straight screwdriver, force the spike tab toward the insideof the connector. Straighten the tab to a vertical position.

    3. Insert the ignitor wire into that same connector leg (just to the 90 bend) and push the wire on to theprotruding spike tab, making sure that the tab penetrates the insulation. (Do not strip the ignitor wire.)Using a crimping tool or pliers, squeeze the sides of the terminal to form a "C" shape. The ignitor wireshould now be firmly held by the terminal.

    4. Slide the protective boot over the terminal. Holding the boot, attach the 90 Rajah terminal to theignitor lead Rajah connector on the Model G60 or G67BG/NG-2 ignition controller.

    IgnitionController forIntermittentSpark PilotSystemwithoutLockout,G67BG-5,P/N 97782

    IgnitionControllerwith Lockout,G770NGC-4,P/N 97547

    Ignition ControllersP/N 97204, PilotHole Cover Plate

    Beginning withSeries 6 Models, besure to re-attach thepilot hole cover platewhen installing thepilot.

    P/N 110853 - Complete Replacement PilotKit for Vertical, Natural Gas, Spark PilotP/N 110854 - Complete Replacement PilotKit for Vertical, Propane Gas, Spark Pilot

    6164 Vertical Spark Pilot -Beginning with Series 6

    6263

    Protective boot and terminal in-stalled on the ignition controllerend of the ignitor wire

    Pilots and Ignition ControllersCode P/N

    55 61145

    61146

    56 6308837801

    57 51459664

    58 5045059 112647 Crimp-on 90 Rajah terminal connector60 112648 90 Boot Terminal Protector

    May not be used; see below.

    Component DescriptionPilot Assembly, Natural Gas, with orifice, less pilot tubing and less flame sensor lead; Baso J992HXW7221

    Pilot Assembly, Propane Gas, with orifice, less pilot tubing and less flame sensor lead; Baso #J992HXW4209Orifice only, Natural Gas (7221)Orifice only, Propane Gas (4209)Pilot Tubing, 22" longNut with breakaway ferrule (2 required when replacing pilot tubing)Flame Sensor Lead, 16"

    55

    57

    56

    58

    59

    60

    Code P/N Component Description61 97534 Pilot Assembly, Natural Gas, with orifice, less pilot tubing and

    less flame sensor lead; Johnson #J982HKW-9731-71597535 Pilot Assembly, Propane Gas, with orifice, less pilot tubing

    and less flame sensor lead; Johnson #J982HKW-9733-410

    62 103034 Orifice only, Natural Gas, Johnson #9731-715 (brass)98695 Orifice only, Propane Gas, Johnson #9733-410 (black)

    63 98698 Pilot Tubing, Johnson #B10499-995-11, 1/8" O.D. x 18" long97572 Compression Fitting, #FTG75 (2 required)

    64 98697 Flame Rod, Johnson #Y75AA-365 97575 Flame Sensor Lead, 21" (not illustrated)

  • Form RZ-NA-P-EEDU, Page 8

    Other Components

    800-695-1901www.RezSpec.com2006 Thomas & Betts Corporation, All rights reserved.MANUFACTURER OF HEATING, COOLING, AND VENTILATING SYSTEMSTrademark Note: Reznor is registered in the United States and other countries.3/06 Form RZ-NA-P-EEDU (Version .1)

    A B C

    A = Temperature Selector, P/N 115848, J/C A350A-1CB = Stage Adder Module, P/N 115849, J/C S350AA-1CC = Display Module, P/N 115852, J/C D350AA-1C

    P/N 103355, 115/24/40VA, Basler#BE141650-WAA (replaces P/N 60368);P/N 103497, 208/230/24/40VA, Basler#BE21539001 (replaces P/N 60369);P/N 103498, 460/24/40VA, Basler#BE23975001 (replaces P/N 60370)

    ControlTransformer

    Two-Stage Electronic Ductstat Modules (Used inOptions AG15 and AG16)

    Ductstat Sensor,P/N 115851

    Ductstat SensorHolder, P/N 115850

    DPST Control Switch, P/N101902 (used in GasControl Options AG3, AG8,AG9, AG15 and AG16)

    Two-Stage Ductstat, P/N 41700,Honeywell (Used in Option AG3)

    Fan Control and Gasket Kit,P/N 57960 (Same as OptionCQ1)

    67- 789%9'4''":

    ;54

    ;

    ;#

    "?"4

    Fan Control Wiring(W.D. 145977)

    Fan Control Location

    May be used as a functionalreplacement for ColumbusElectric fan control used onEEDU Series prior to 6/96.

    Mounting Holes

    %01

    % 2!%/

    3!%/

    2

    1!1

    Drill a 3/16" hole for sensor

    Drill four 1/8" holes for screws

    Fan control is rated for maximum motorsize 3/4 HP, 1Ph @ 115 or 230 VAC.Larger motors or 3 Ph require use ofcontactor or starter.

    P/N 134170, Maxitrol SignalConditioner (used in Gas ControlOption AG21)

    Bulb Holder,P/N 100260Cable Strap,P/N 16227

    NOTE: If P/N 41700 isEssex brand, the bulbholder is P/N 104156