20
PARKING STRUCTURE PGL SERIES Parkin g Gara g e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4

Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

PARKING STRUCTURE

PGLSERIES

P a r k i n g G a r a g e L u m i n a i r e s

1 0 0 - 1 5 0 Wa t t H I D • 8 5 Wa t t I n d u c t i o n

PGL4

Page 2: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

PGL4

Proven Success

SITE / AREAPARKING STRUCTURE

ROADWAYARCHITECTURAL FLOOD

ACCENTLANDSCAPE

MAILING ADDRESS:P.O. BOX 60080

CITY OF INDUSTRY, CA91716-0080

BUSINESS ADDRESS:16555 EAST GALE AVENUE

CITY OF INDUSTRY, CA 91745U.S.A.

PHONE 626 / 968 - 5666FAX 626 / 369 - 2695

ENTIRE CONTENTS © COPYRIGHT 2012 KIM LIGHTING INC.

ALL RIGHTS RESERVEDREPRODUCTION IN WHOLE OR IN PART

WITHOUT PERMISSION IS STRICTLY PROHIBITED.

www.kimlighting.com

Printed in U.S.A.5502613095

Version 2.4 (4/13)

Hubbell Lighting, Inc.

Table of Contents

Design 2-3

Features 4

Installation and Maintenance 5

LuminaireOrdering Information 6-7

Luminaire Specifications 8

Optical Choices 9

PGL4 10-11

DL-WWide Downlight Option 12-13

DL-NNarrow Downlight Option 14-15

Induction FluorescentLamp Option 16

Related Products 17

Application Engineering Services 17

PGL4

Over 2 decades ago, Kim took a long hard look atParking Garage Lighting and concluded that a greatdeal of improvement could be made.

In 1989, Kim introduced the PGL Parking GarageLuminaire. This innovative product was the first to offeran integrated, direct/indirect luminaire, purposely builtfor modern parking garage facilities.

Today, the Kim PGL4 remains the choice for parkinggarage lighting design. Continuous improvement,including a regular program of enhancements andinnovations, keeps the PGL4 the leader in garageillumination.

Page 3: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 1

Page 4: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

Design

The Dynamics of Parking Garage Lighting Design

2 KIM LIGHTING

Low overall ceiling heights and deep exposed structuralelements combine to create a “cave effect.” This isovercome by including indirect illumination of the ceilingsurfaces in the lighting system design.

For the safety and security of people entering andleaving their vehicles, and easy identification of openparking spaces for traffic flow, vertical illumination in theparking zones is required. This is best approached throughdirect high angle illumination, combined with ambientindirect lighting to reduce harsh shadows and contrast.Busy traffic in the drive lanes, plus cars backing out ofparking spaces and negotiating within confined space,requires high visibility. This can only be accomplished bycutoff optical designs that provide high vertical illuminancewith minimal glare.

Visibility of the facility must provide an invitingappearance with no glare to surrounding properties. Thecombination of indirect illumination of the garage interiorand cutoff optical control, provides the most attractivepresentation from the exterior of the garage.

Fixture row spacings are controlled by the structuralelements of the garage. Luminaire performance must bedesigned to accommodate the various combinations ofstructural element depths used to construct moderngarage facilities.Fixture design considerations also include ease ofinstallation, ease of maintenance, and resistance tointrusion by insects, dirt, or water. Other considerations ingarages may include controlling bird nesting, vandalresistance and mounting system flexibility.

A

B

C

D

E

A B C D

A

C

D

B

E

Page 5: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 3

PGL4 Design

Integrated Approach

Clear uplight windowand diffuse reflectorsegment

Drive Lane Direction

Prismatic uplight windowand specular reflectorsegment

Drive Lane Direction

Symmetric reflector

Diffuse Uplight eliminates the “cave effect”and provides a secure and invitingappearance. This ambient light also reducescontrast between the fixture brightness andceiling, which increases visibility.

Up/Downlight produces high verticalilluminance to reach between parkedvehicles. This improves visibility andprovides a sense of security and safety.

Cutoff Downlight provides overallillumination with low glare. A balance ofproviding high vertical illuminance and drive lane comfort is accomplished by a symmetrical reflector design that redirects light from unwanted angles to moreuseful zones.

Integrated Design for completePerformance is the approach taken in the development of the PGL Series.By providing comfortable illumination,eliminating the “cave effect,” and producingexcellent visibility, the PGL series continuesto satisfy the strictest of parking garagelighting design.

Page 6: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

Features

4 KIM LIGHTING

Speed MountThe Kim “Speed Mount” easily attaches to mud boxes as well as standard 4" junction boxes.

Wire SealA molded silicone grommet provides protectionagainst moisture entry by sealing all three wiresexiting the fixture top.

Die-Cast Housing, FinishThe electrical housing is die-cast aluminumfinished in Kim’s exclusive “Super TGIC” powder coat paint. Housing hangs from the “Speed Mount” for easy wiring, and locks into place once it is raised to the finalmounting position.

Housing GasketFor added longevity, the housing gasket is a one-piece silicone component.

Hanger HingeA stainless steelhanger hinge allowseasy no-tool removalof the downlightwindow.

Downlight WindowThe injection molded downlight window has been configured forgreatest performance by optimizing the light transmission at highangles. The standard material is high temperature UV stabilizedacrylic with optional polycarbonate available.

Hydroformed ReflectorThe primary reflector is a one-piece hydroformed aluminumcomponent with an Alzak®

finish. This provides maximumlongevity, maintained light outputand easier care over vacuum-metalized reflectors. Verticalfacets prevent reflected light frompassing through the lamp forhigh efficiency and long lamp life.The reflector is retained insidethe one-piece injection moldedpolycarbonate optical housing.See photo below.

UplightComponentA generous amount ofuplight is provided toilluminate the ceilingand beams. Thisreduces the “caveeffect,” providing amore inviting parkinggarage with a greatersense of security.

Hydroformed Uplight ReflectorThe one-piece hydroformed uplight reflector isconfigured to capture and redirect lamp outputto useful angles. It also retains the lamp socket,and is easily removable for access to theelectrical components.

Electrical ComponentsAll ballasts and related components are rigidlymounted inside the die-cast housing and 100%tested before shipment.

Gasket and FastenersThe downlight window gasket issilicone for maximum recoveryof shape after relamping. Theclosure fasteners are stainlesssteel captive shoulder screws toprevent over-tightening andcracking of the lens.See detail below.

Uplightto Parking StallsTwo prism areas inthe uplight windowbend light downwardfor extra fill into theparking stalls. Prismareas are 180° apart.

Wide Throw DownlightThe primary garage illumination is providedby cutoff downlight in which the lamp is fullyshielded above horizontal. Full coverage ofthe garage bay is achieved by the widethrow and high candlepower.

TowardParking

Stalls

TowardDrivingLane

A B

CutoffCutoff

Top view of luminaire and orientation to parking stalls.

Prisms

A

B

Parking Stalls

Prisms

Page 7: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 5

Speed Mount and Optional Bird ShroudBecause parking garage luminaires must be installed quickly andsecurely, every PGL is supplied with the Kim “Speed Mount.” The “Speed Mount” attaches to any standard 4" junction box ormud box, whether recessed, surface or rigid pendant1 mounted. It serves as a fixture hanger, freeing both hands for connecting fieldwires, and locks the fixture to the junction box without tools. 1See PB2 option on page 8.

Wiring and LockingWith the “Speed Mount” in place, the PGL luminaire can be removed from its carton and easily installed without tools. Thefixture hangs at an angle so field wire connections can be quicklyand easily made. All wires are tucked into the junction box, and the fixture is ready for final mounting. Without tools, the fixture is simply lifted and pushed forward until an audible lock is heard.At this point, the fixture is locked to the junction box and cannot be removed without internal access through the ballastcompartment. This feature reduces the possibility of theft,particularly during the period prior to building occupancy.

Lamping and RelampingFor initial lamping or future relamping, the downlight window is hinged and retained by three captive screws. Access to the lamp is quick, and the entire lamping task can be rapidlyaccomplished. Relamping schedules should always be combinedwith basic cleaning to maintain optimum light output. Since the PGL optical chamber is totally sealed, exterior dusting is all that is normally required.

For additional installation labor cost savings and convenience,fixtures can be ordered with lamp included and factory installed,allowing fixture to be installed without opening the optical chamber.

Control of Light PollutionParking garages are notorious for light pollution because they have traditionally been illuminated with non-cutoff prismed refractorluminaires. The PGL now allows parking garages to be fullyilluminated without significant light spill into the surroundingneighborhood.

PGL test installation

Non-Cutoff prismedrefractor luminaires,175 watt Metal Halide

Kim PGL, 150 wattHigh Pressure Sodium

Installation and Maintenance

Page 8: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

Luminaire Ordering Information

6 KIM LIGHTING

Ordering Example:

1 Fixture:

Fixture Electrical Module Options

PGL4 / 175MH277 / DL-N/ LS / PB2 / QS / TS / SF1 2 3-10

PGL4

2 Electrical Module:PMH = Pulse Start Metal Halide

HPS = High Pressure Sodium

IF = Induction Fluorescent

Lamp Lamp LineWatts Type Volts

150 PMH 277

PGL4Contemporary garage luminaire. Die-cast, low copper (<0.6% CU)aluminum alloy ballast housing with Platinum Silver Super TGIC powdercoat paint over titanated zirconium conversion coating, one-piece clearoptical housing. Downlight optical reflector visible through optical housingmaterial.

ElectricalLamp Mode Module Line Input Max. Input(Lamps by others) Cat. No. Volts Watts Amps2

100 Watt Clear 100PMH120 120 129 2.30Pulse Start Metal Halide 100PMH208 208 129 1.40ED-17 Medium Base 100PMH240 240 129 1.15ANSI Ballast Type M-90 100PMH277 277 129 1.00

100PMH347 347 129 1.00100PMH480 4803 129 0.55

150 Watt Clear 150PMH120 120 185 3.65Pulse Start Metal Halide 150PMH208 208 185 2.10ED-17 Medium Base 150PMH240 240 185 1.80ANSI Ballast Type M-102 150PMH277 277 185 1.58

150PMH347 347 185 1.25150PMH480 4803 185 0.81

100 Watt Clear 100HPS120 120 130 2.20High Pressure Sodium 100HPS208 208 130 1.40E-17 Medium Base 100HPS240 240 130 1.10ANSI Ballast Type S-54 100HPS277 277 130 0.95

100HPS347 347 130 0.70100HPS480 4803 130 0.34

150 Watt Clear 150HPS120 120 188 3.00High Pressure Sodium 150HPS208 208 188 1.65E-17 Medium Base 150HPS240 240 188 1.45ANSI Ballast Type S-55 150HPS277 277 188 1.25

150HPS347 347 188 0.92150HPS480 4803 188 0.70

85 Watt 85IF120 120 86 0.73Induction Fluorescent 85IF208 208 86 0.38

85IF240 240 86 0.3685IF277 277 90 0.38

2Max. Amps reflect open circuit current load.3480 volt with medium base sockets may require approval of local building code authority.

CAUTION: All manufacturers ofmetal halide lamps recommendturning them off for 15 minutes onceper week when under continuousoperation. This will reduce the risk ofarc tube rupture at end of life. Also, color temperature may differ between manufacturers ofmetal halide lamps. See lampmanufacturer’s specification sheets.

All fixtures are available pre-lampedby Kim. Consult representative forpricing.

NOTE: Due to the Energy Independence and Security Act (EISA) of 2007, Kim Lighting can no longer supply probestart metal halide ballasts with its luminaires, effective January 1, 2009. Contact Kim Lighting for availability ofreplacement ballasts for warranty service claims.(Visit www.aboutlightingcontrols.org or the Library of Congress website for more details.)

Page 9: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

9 Optional Fusing:

5 Optional PolycarbonateDownlight Lens:

KIM LIGHTING 7

3 Optional NarrowDownlight Optics:

Line Volts: 120V 208V 240V 277V 347V 480V

Cat. No.: SF DF DF SF SF DF

6 Optional BalancedPendant Junction Boxand Bird Shroud:

4 Optional WideDownlight Optics:

Cat. No.: DL-N Two-piece hydroformed aluminum reflector with Alzak® finish.Reflector fills optical housing and provides minimal uplightdistribution. Symmetric downlight distribution is narrowerthan standard symmetric pattern, with increased intensity.

Cat. No.: DL-W Two-piece hydroformed aluminum reflector with Alzak® finish.Reflector fills optical housing and provides minimal uplightdistribution. Symmetric downlight distribution is similar tostandard symmetric pattern, with increased intensity.

Cat. No.: LS One-piece clear injection molded UV stabilizedpolycarbonate downlight lens in place of standard acrylic.

CAUTION: Use only when fixture vandalism is anticipatedwithin the parking garage. Service life is reduced by UVdiscoloration from metal halide lamps. High PressureSodium lamps are recommended to promote full service life.

Cat. No.: PB2 Cast aluminum, finished to match fixture body. Offset L" NPT pendant entry to balance fixture in free-swinginginstallation. For fixture mounting, Kim Speed Mount attachesdirectly to Balanced Pendant Junction Box (PB2).

7 Optional QuartzStandby:

Cat. No.: QS Integral current sensing relay energizes a T-4 mini-cansocket during lamp warm-up and after power interruption.Socket de-energizes prior to the HID lamp reaching full brightness. T-4 mini-can halogen lamp by others; 100 watt maximum.

NOTE: Input amps will increase by .80 with this option.Not available on 85IF.

8 Optional Tamper-Resistant Lens Screws:

Cat. No.: TS Captive hex socket (allen) shoulder screws provided for downlight window instead of standardphillips-head screws.

10 Lamp Included: To order fixtures with lamp included and installed, add “lamp included” suffix to catalog number. Will also includeQS option lamp (when specified).

PolycarbonateDownlight Lens

Balanced PendantJunction Box and Bird Shroud

Single Fuse

Quartz Standby

Page 10: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

Listings and RatingsUL cUL 15981 40C AmbientIP66 Rated ISO 9001:2000

ElectricalHousing

OpticalHousing

DownlightWindow

3 B "

(79.4 mm)

11 " DIA. (279.4 mm)

16 " DIA. (406.4 mm)

6 D" (168.3 mm)

2 "

(50.8 mm)

11 L"

(298.5 mm)

Speed Mount

Toward Parking Stalls

Toward Parking Stalls

Hinge

Mounting holes for standard mud box or 4 " J-box

Rigid conduit pendant Standard 4 " J-box or optional PB2 J-box

Dimensions

Pendant Installations

Free-swinging pendant PB2 Balanced Pendant J-box

• For rigid conduit pendant mount, use a standard 4" junction box with a centered pendant entry.

• For Free-swing pendant mount, use the optional PB2 Balanced Pendant Junction Box (page 7).

• For all pendant installations where bird shroud protection is desired, use the optional PB2 Balanced Pendant Junction Box (page 7).

Luminaire Specifications

PGL4

8 KIM LIGHTING

Speed Mount: Formed steel, electro-zinc plated for mounting to standard 4" junction box or mud box. Hooks are designed to hangfixture, freeing both hands for field wire connections. Allows tool-freefixture mounting to junction box, with integral anti-theft locking device.

Ballast Housing: Die-cast, low copper (<0.6% Cu) aluminum alloyfor direct mounting to the Kim Speed Mount. Wire entry is sealed witha silicone grommet.

Optical Housing: One-piece injection molded UV stabilizedpolycarbonate (minimum wall thickness .125") with hydroformedAlzak® aluminum reflector insert. Reflector has vertical facets toprevent reflected light from passing through the lamp envelope.Uplight window contains two prismed sections to spread additionallight downward in the direction of parking stalls. Optical Housing issecured to Electrical Housing with full silicone gasketing around theperimeter.

Uplight Reflector and Socket: One-piece hydroformed aluminumwith Alzak® surface facing prisms and diffuse white surface facinguplight window areas. Socket is 4KV pulse rated medium base.Reflector is removed by loosening three screws allowing access to the electrical components.

Downlight Window: One-piece clear injection molded UV stabilizedhigh temperature acrylic (polycarbonate optional). Attached to Optical Housing with a “no-tool” quick release spring hinge andthree captive phillips-head “shoulder” type screws to preventovertightening (tamper-resistant hex socket screws optional).Perimeter is fully gasketed with silicone. Convex shape yieldsmaximum light transmission.

HID Electrical Components: High power factor ballasts for -20°F. starting, rigidly mounted inside electrical housing and prewiredwith leads extended out top of housing.

Induction Fluorescent Lamp Electrical Components: CompleteHF generator and induction lamp system is furnished. Induction lampsystem is high power factor, rated for -4° starting.

Optical Configuration: In the direction of the driving lanes, luminairedownlight is of the “cutoff” classification with uplight provided forilluminating ceiling and beams. In the direction of parking stalls,luminaire is a “semi-direct” type with partial uplight refracteddownward for additional fill-light in the parking stalls. In all directions,lamp is shielded from normal viewing angles by the opaque reflectorsection of the luminaire.

Finish: Platinum Silver color on ballast housing only. Super TGICthermoset polyester powder coat paint over titanated zirconiumconversion coating. Clear optical housing.

CAUTION: Fixtures must be grounded in accordance with national,state and/or local codes. Failure to do so may result in seriouspersonal injury.

1Suitable for wet locations.

Page 11: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 9

Optical Choices

DL-NOptional Narrow Downlight Distribution (Minimum Uplight)Modern parking structures include areas where ceiling heights arehigher for access by emergency vehicles, or other similarconstruction. The DL-N option provides increased downlight intensityin a narrower distribution, for increased mounting heights. This optioncan also be used where focused horizontal illumination levels are desired, such as entries and ticket dispenser locations.

• Narrow distribution for higher mounting heights

• Cutoff optics and minimum uplight control glare and luminairebrightness

• Retains aesthetic continuity with standard distribution luminaires

PGL4Standard DistributionInnovated by Kim in 1989, the PGL system of garage luminaires hasrevolutionized how parking structures are illuminated. Designed to provide uniform vertical and horizontal illumination when installedin regular garage areas, the PGL4’s uplighting reduces the “caveeffect” by illuminating the ceiling surfaces.

The PGL4 offers the following features:

• Wide distribution for optimum fixture spacing and economy

• Asymmetric uplight reduces “cave effect” and maximizes visibility

• Cutoff optics controls glare

DL-WOptional Wide Downlight Distribution (Minimum Uplight)The DL-W option is offered for applications where restricted uplightdistribution is desired. The downlight distribution is essentially thesame as the standard PGL4, maintaining full cutoff optical control,with an increase in output, from redirection of uplight illumination intothe direct illumination zone.

• Wide distribution with increased intensity

• Cutoff optics and minimum uplight control glare and luminairebrightness

• Retains aesthetic continuity with standard distribution luminaires

0° 30°60°

30°60°

90°90°

120°120° 150°150° 180°

CandlepowerDistributionTowardDriving Lane

CandlepowerDistribution

TowardParking Stalls

0° 30°60°

30°60°

90°90°

120°120° 150°150° 180°

CandlepowerDistributionTowardDriving Lane

CandlepowerDistribution

TowardParking Stalls

0° 30°60°

30°60°

90°90°

120°120° 150°150° 180°

CandlepowerDistributionTowardDriving Lane

CandlepowerDistribution

TowardParking Stalls

Page 12: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

PGL4

Single Row Per Bay

F

F

D

D

A

E

E

C

C

B

F

F

D

D

A

PLAN VIEW

SBay

Width

10 KIM LIGHTING

150 Watt HPSE-17 clearmedium base16,000 initial lumensI.T.L. Test No. 48443Light Loss Factor: 0.81

150 Watt PMHE-17 clearmedium base13,300 initial lumensI.T.L. Test No. 48440Light Loss Factor: 0.72

H

Not to scale

H

Not to scale

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

15' 34.3 25.0 12.5 12.3 4.46 4.36 12.95 2.97 7.87

30' 23.5 10.5 5.97 6.27 2.04 2.25 7.18 3.52 11.52

15' 28.1 23.2 12.3 12.3 6.19 6.11 12.67 2.07 4.6

30' 19.0 8.73 6.5 5.75 2.95 3.12 6.72 2.28 6.44

15' 24.0 22.0 11.9 12.4 8.02 7.81 12.7 1.63 3.07

30' 16.3 7.49 6.53 5.78 3.79 3.92 6.63 1.75 4.3

15' 34.2 25.0 11.2 11.1 3.12 3.08 11.92 3.87 11.1

30' 23.5 10.4 5.20 5.82 1.44 1.57 6.69 4.65 16.32

15' 27.8 23.0 11.4 11.4 4.54 4.47 11.59 2.59 6.22

30' 19.2 8.77 5.88 5.40 2.15 2.28 6.26 2.91 8.93

15' 23.7 21.8 11.0 11.4 6.07 5.98 11.53 1.93 3.96

30' 16.4 7.45 6.00 5.21 2.92 2.98 6.05 2.07 5.62

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

15' 31.3 21.5 10.2 10.2 2.93 2.85 10.84 3.8 10.98

30' 22.5 8.46 5.02 5.09 1.24 1.52 6.17 4.98 18.15

15' 25.2 19.9 9.78 10.3 4.35 4.35 10.46 2.4 5.79

30' 17.9 6.86 5.56 4.56 2.00 2.26 5.66 2.83 8.95

15' 21.6 19.0 9.61 10.1 6.22 5.98 10.52 1.76 3.61

30' 15.3 5.99 5.29 4.56 2.82 3.03 5.54 1.96 5.43

15' 31.2 21.4 9.39 9.15 1.97 1.97 10.07 5.11 15.84

30' 22.5 8.44 4.29 4.78 0.88 1.00 5.8 6.59 25.57

15' 24.9 19.7 9.13 9.50 3.00 2.98 9.58 3.21 8.56

30' 18.2 6.93 5.11 4.28 1.38 1.54 5.3 3.84 13.19

15' 21.3 18.8 8.92 9.30 4.40 4.30 9.49 2.21 4.95

30' 15.5 5.98 5.03 4.14 2.01 2.15 5.06 2.52 7.71

Maintained IlluminationIncludes 32% effective ceiling reflectance (40% surfacereflectance, with 24" D structural beams).

NOTE: Contributions from adjacent bays included inareas shown.

Page 13: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 11

PGL4

Double Row Per Bay

150 Watt HPSE-17 clearmedium base16,000 initial lumensI.T.L. Test No. 48443Light Loss Factor: 0.81

150 Watt PMHE-17 clearmedium base13,300 initial lumensI.T.L. Test No. 48440Light Loss Factor: 0.72

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

27.5' 15' 38.7 29.5 25.0 24.6 25.1 24.6 29.07 1.18 1.57

27.5' 30' 25.8 12.6 12.0 12.6 12.0 12.6 16 1.33 2.15

27.5' 15' 31.0 26.4 22.0 22.1 21.9 22.1 24.99 1.14 1.42

27.5' 30' 22.6 11.9 13.1 11.7 13.0 11.5 14.83 1.29 1.97

27.5' 15' 28.6 27.0 21.2 22.3 21.1 22.2 24.32 1.15 1.36

27.5' 30' 20.4 11.4 13.2 11.7 13.2 11.7 14.26 1.25 1.79

30' 15' 37.5 28.2 22.3 22.3 22.3 22.2 27.07 1.22 1.69

30' 30' 25.2 12.0 10.5 11.7 10.5 11.7 15.08 1.44 2.4

30' 15' 32.5 27.7 22.8 22.7 22.7 22.7 25.99 1.14 1.43

30' 30' 21.7 11.0 11.9 10.9 11.9 10.8 13.91 1.29 2.01

30' 15' 29.8 27.9 22.1 22.7 22.1 22.7 25.13 1.14 1.35

30' 30' 19.3 10.4 12.1 10.5 12.1 10.6 13.13 1.26 1.86

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

27.5' 15' 34.2 24.5 20.4 20.4 20.4 20.4 24.61 1.21 1.68

27.5' 30' 24.1 9.78 10.1 10.3 10.1 10.3 13.86 1.42 2.46

27.5' 15' 26.8 21.8 17.5 18.4 17.4 18.4 20.88 1.2 1.54

27.5' 30' 20.5 9.05 11.3 9.30 11.3 9.23 12.64 1.4 2.27

27.5' 15' 24.8 22.6 17.0 17.9 17.0 17.9 20.17 1.19 1.46

27.5' 30' 18.6 8.95 10.8 9.30 10.8 9.34 12.03 1.34 2.08

30' 15' 33.4 23.5 18.8 18.4 18.7 18.3 23.06 1.26 1.83

30' 30' 23.6 9.43 8.69 9.67 8.70 9.68 13.15 1.51 2.72

30' 15' 28.1 22.9 18.3 19.0 18.3 19.0 21.81 1.19 1.54

30' 30' 20.0 8.35 10.3 8.71 10.3 8.68 11.92 1.43 2.4

30' 15' 25.8 23.3 17.8 18.6 17.8 18.6 20.95 1.18 1.45

30' 30' 17.6 8.11 10.2 8.35 10.2 8.39 11.1 1.38 2.18

H

Not to scale

H

Not to scale

Maintained IlluminationIncludes 32% effective ceiling reflectance (40% surfacereflectance, with 24" D structural beams).

NOTE: Contributions from adjacent bays included inareas shown.

Page 14: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

DL-W Wide Downlight Option

Single Row Per Bay

12 KIM LIGHTING

150 Watt HPSE-17 clearmedium base16,000 initial lumensI.T.L. Test No. 49266Light Loss Factor: 0.81

150 Watt PMHE-17 clearmedium base13,300 initial lumensI.T.L. Test No. 49263Light Loss Factor: 0.72

F

F

D

D

A

E

E

C

C

B

F

F

D

D

A

PLAN VIEW

SBay

Width

H

Not to scale

H

Not to scale

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

15' 32.1 31.7 12.9 12.8 4.16 4.10 13.8 3.21 7.83

30' 21.3 10.7 5.63 7.13 1.87 2.19 7.04 3.76 11.39

15' 27.1 26.7 13.3 13.5 5.87 5.91 13.13 2.24 4.63

30' 17.2 9.94 6.29 7.12 2.80 3.06 6.87 2.45 6.14

15' 24.2 23.9 13.7 14.2 7.79 7.71 13.52 1.75 3.14

30' 14.4 9.68 6.63 7.41 3.70 3.90 6.96 1.88 3.89

15' 32.0 31.6 11.3 11.3 2.88 2.88 12.05 4.18 11.1

30' 21.3 10.7 4.88 6.34 1.34 1.48 6.47 4.83 15.9

15' 27.1 26.6 12.0 11.9 4.25 4.29 11.87 2.79 6.38

30' 17.1 9.89 5.63 6.21 2.01 2.20 6.2 3.08 8.51

15' 24.1 23.7 12.3 12.5 5.77 5.82 12.09 2.1 4.18

30' 14.3 9.60 5.97 6.40 2.81 2.93 6.2 2.21 5.09

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

15' 32.0 28.7 10.4 10.4 2.54 2.46 11.33 4.61 13.01

30' 22.7 9.20 4.35 5.94 1.06 1.34 6.3 5.94 21.42

15' 26.6 24.3 10.8 11.0 3.79 3.85 11.07 2.92 7.02

30' 17.9 8.54 5.11 5.80 1.74 2.04 5.96 3.43 10.29

15' 23.4 21.9 11.1 11.6 5.44 5.37 11.31 2.11 4.36

30' 14.9 8.36 5.40 6.01 2.49 2.75 5.93 2.38 5.98

15' 31.9 2.87 9.00 9.01 1.68 1.68 10.45 6.22 18.99

30' 22.7 9.18 3.66 5.28 0.75 0.85 5.86 7.81 30.27

15' 26.5 24.2 9.73 9.75 2.60 2.64 10.09 3.88 10.19

30' 17.9 8.53 4.56 5.06 1.18 1.35 5.43 4.6 15.17

15' 23.3 21.8 9.96 10.2 3.81 3.81 10.13 2.66 6.12

30' 14.8 8.32 4.85 5.14 1.77 1.93 5.3 2.99 8.36

Maintained IlluminationIncludes 32% effective ceiling reflectance (40% surfacereflectance, with 24" D structural beams).

NOTE: Contributions from adjacent bays included inareas shown.

Page 15: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 13KIM LIGHTING 13

150 Watt HPSE-17 clearmedium base16,000 initial lumensI.T.L. Test No. 49266Light Loss Factor: 0.81

150 Watt PMHE-17 clearmedium base13,300 initial lumensI.T.L. Test No. 49263Light Loss Factor: 0.72

DL-W Wide Downlight Option

Double Row Per Bay

H

Not to scale

H

Not to scale

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

27.5' 15' 36.2 35.8 25.9 25.6 25.9 25.6 29.85 1.17 1.41

27.5' 30' 23.7 12.6 11.3 14.3 11.3 14.4 15.97 1.41 2.09

27.5' 15' 30.8 30.3 24.4 24.7 24.4 24.7 26.98 1.11 1.26

27.5' 30' 20.3 12.8 12.7 14.3 12.6 14.3 15.35 1.22 1.61

27.5' 15' 29.6 29.3 25.2 26.0 25.1 26.0 27.22 1.08 1.18

27.5' 30' 18.4 13.5 13.3 14.9 13.3 14.9 15.33 1.15 1.38

30' 15' 34.9 34.5 22.6 22.7 22.6 22.7 27.51 1.22 1.54

30' 30' 22.9 12.1 9.87 12.8 9.87 12.8 14.81 1.5 2.32

30' 15' 31.4 30.9 24.1 23.9 24.1 23.9 26.87 1.12 1.31

30' 30' 19.3 12.0 11.4 12.5 11.4 12.5 14.03 1.23 1.69

30' 15' 29.9 29.5 24.6 25.0 24.6 25.0 26.83 1.09 1.22

30' 30' 17.4 12.5 12.1 12.9 12.1 12.9 13.87 1.15 1.44

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

27.5' 15' 34.5 31.3 20.9 20.8 20.9 20.7 25.85 1.25 1.67

27.5' 30' 24.2 10.3 8.81 12.0 8.81 12.0 14.38 1.63 2.75

27.5' 15' 28.5 26.2 19.7 20.2 19.6 20.2 23.1 1.18 1.45

27.5' 30' 20.1 10.4 10.3 11.7 10.3 11.7 13.49 1.31 1.95

27.5' 15' 26.8 25.4 20.4 21.2 20.4 21.2 23.1 1.13 1.31

27.5' 30' 17.7 11.0 11.0 12.2 10.9 12.1 13.23 1.21 1.62

30' 15' 33.7 30.4 18.0 18.1 18.1 18.1 23.88 1.33 1.87

30' 30' 23.6 10.0 7.42 10.7 7.43 10.7 13.39 1.8 3.18

30' 15' 29.2 26.9 19.5 19.6 19.5 19.5 23.09 1.18 1.5

30' 30' 19.4 9.81 9.26 10.3 9.25 10.3 12.45 1.35 2.1

30' 15' 27.2 25.7 20.0 20.4 19.9 20.4 22.83 1.15 1.37

30' 30' 16.9 10.2 9.92 10.5 9.90 10.5 12.05 1.22 1.71

Maintained IlluminationIncludes 32% effective ceiling reflectance (40% surfacereflectance, with 24" D structural beams).

NOTE: Contributions from adjacent bays included inareas shown.

Page 16: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

DL-N Narrow Downlight Option

Single Row Per Bay

14 KIM LIGHTING

150 Watt HPSE-17 clearmedium base16,000 initial lumensI.T.L. Test No. 49260Light Loss Factor: 0.81

150 Watt PMHE-17 clearmedium base13,300 initial lumensI.T.L. Test No. 49257Light Loss Factor: 0.72

F

F

D

D

A

E

E

C

C

B

F

F

D

D

A

PLAN VIEW

SBay

Width

H

Not to scale

H

Not to scale

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

10'

55' 12'

14'

10'

60' 12'

14'

15' 27.1 37.9 13.2 12.8 2.58 2.48 12.31 4.96 15.28

30' 13.7 13.3 4.30 8.39 1.13 1.23 6 5.31 12.12

15' 23.2 29.3 14.5 14.7 3.90 3.94 12.48 3.2 7.51

30' 10.1 12.9 6.57 7.94 1.69 2.04 5.97 3.53 7.63

15' 20.4 23.7 15.0 15.7 6.11 6.10 12.93 2.12 3.89

30' 8.33 11.6 7.52 7.76 2.60 3.10 6.13 2.36 4.46

15' 27.0 37.8 10.7 10.5 1.91 1.89 11.11 5.88 20

30' 13.7 13.3 3.39 6.94 0.86 0.90 5.37 6.24 15.93

15' 23.1 29.2 12.9 12.8 2.81 2.76 11.27 4.08 10.58

30' 10.1 12.8 5.56 6.93 1.15 1.35 5.3 4.61 11.13

15' 20.2 23.4 13.5 13.8 4.24 4.24 11.44 2.7 5.52

30' 8.26 11.6 6.67 6.74 1.78 2.04 5.34 3 6.52

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

10'

55' 12'

14'

10'

60' 12'

14'

15' 24.0 24.1 10.1 9.58 1.91 1.85 10.12 5.47 18.43

30' 13.5 10.4 2.63 6.77 0.83 0.88 4.99 6.01 16.27

15' 20.6 25.3 11.9 11.3 2.57 2.60 10.07 3.92 9.84

30' 9.71 10.8 4.55 6.42 1.10 1.22 4.81 4.37 9.82

15' 17.7 20.1 12.1 12.7 3.92 3.83 10.25 2.68 5.25

30' 7.54 9.74 6.04 6.24 1.49 1.92 4.83 3.24 6.54

15' 23.9 34.1 7.72 7.43 1.44 1.41 9.04 6.41 24.18

30' 13.5 10.4 2.00 5.31 0.62 0.65 4.43 7.15 21.77

15' 20.6 25.2 10.4 9.69 1.97 1.93 9.18 4.76 13.06

30' 9.66 10.7 3.72 5.65 0.79 0.82 4.33 5.48 13.54

15' 17.5 20.0 10.9 10.9 2.67 2.60 9.08 3.49 7.69

30' 7.50 9.70 5.13 5.29 1.01 1.11 4.17 4.13 9.6

Maintained IlluminationIncludes 32% effective ceiling reflectance (40% surfacereflectance, with 24" D structural beams).

NOTE: Contributions from adjacent bays included inareas shown.

Page 17: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 15

150 Watt HPSE-17 clearmedium base16,000 initial lumensI.T.L. Test No. 49260Light Loss Factor: 0.81

150 Watt PMHE-17 clearmedium base13,300 initial lumensI.T.L. Test No. 49257Light Loss Factor: 0.72

DL-N Narrow Downlight Option

Double Row Per Bay

H

Not to scale

H

Not to scale

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

10'

55' 12'

14'

10'

60' 12'

14'

27.5' 15' 29.7 40.5 26.5 25.7 26.5 25.7 28.91 1.12 1.58

27.5' 30' 15.1 14.6 8.80 17.0 8.78 17.0 14.53 1.65 1.94

27.5' 15' 27.3 33.4 29.3 29.7 29.2 29.6 29.43 1.08 1.22

27.5' 30' 12.4 14.8 13.4 16.1 13.4 16.1 14.4 1.16 1.3

27.5' 15' 26.6 29.9 30.2 31.5 30.1 31.4 29.67 1.12 1.18

27.5' 30' 11.9 14.7 15.5 16.0 15.4 15.9 14.59 1.23 1.34

30' 15' 29.1 39.8 21.5 21.1 21.5 21.1 25.81 1.22 1.89

30' 30' 14.8 14.3 7.03 14.1 7.03 14.1 12.9 1.83 2.11

30' 15' 26.1 32.1 25.9 25.8 25.9 25.8 26.73 1.04 1.24

30' 30' 11.8 14.3 11.5 14.3 11.5 14.3 13.07 1.14 1.24

30' 15' 20.2 23.4 13.5 13.8 4.25 4.24 11.44 2.7 5.52

30' 30' 10.7 13.8 13.8 14.0 13.8 13.9 13.04 1.22 1.31

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

10'

55' 12'

14'

10'

60' 12'

14'

27.5' 15' 26.0 36.2 20.3 19.3 20.2 19.2 23.5 1.22 1.89

27.5' 30' 14.6 11.4 5.53 13.8 5.51 13.8 12.04 2.19 2.65

27.5' 15' 23.5 28.1 24.1 22.8 24.1 22.7 23.91 1.05 1.24

27.5' 30' 11.2 12.2 9.49 13.2 9.48 13.2 11.79 1.24 1.39

27.5' 15' 21.7 24.2 24.4 25.6 24.4 25.6 24.13 1.11 1.18

27.5' 30' 9.91 11.7 12.5 13.0 12.5 12.9 11.88 1.2 1.31

30' 15' 25.5 35.7 15.6 15.0 15.6 15.0 20.69 1.38 2.38

30' 30' 14.4 11.2 4.24 10.9 4.24 10.9 10.54 2.49 3.4

30' 15' 22.7 27.4 21.0 19.6 21.0 19.6 21.75 1.11 1.4

30' 30' 10.9 11.9 7.92 11.7 7.89 11.7 10.75 1.36 1.51

30' 15' 20.4 22.9 22.0 22.1 22.0 22.0 21.71 1.06 1.12

30' 30' 9.06 11.1 10.8 11.1 10.7 11.1 10.48 1.16 1.23

Maintained IlluminationIncludes 32% effective ceiling reflectance (40% surfacereflectance, with 24" D structural beams).

NOTE: Contributions from adjacent bays included inareas shown.

Page 18: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

8'

55' 9'

10'

8'

60' 9'

10'

16 KIM LIGHTING

Induction Fluorescent Lamp Option

Double Row Per Bay

85 Watt Induction Fluorescent6,000 initial lumensI.T.L. Test No. 46569Light Loss Factor: 0.85

The 100,000 Hour Induction Fluorescent Lamp Features & Benefits• Ultra-long lamp life; <20% failure at 60,000 hours, and <50%

failure at 100,000 hours.

• Excellent lumen maintenance; over 70% of initial light output ismaintained after 60,000 hours.

• Good efficiency; 85 Watt lamp rated at 6000 lumens or 70 lumensper watt. Comparable output to 70 Watt High Pressure Sodium.

• Excellent color; 4000°K. white light, CRI >80, no color deviation.

• Electronic control; fluctuations in supply voltage have a negligibleeffect on light output, >0.9 power factor, -20°C. (-4°F.) starting.

• Fast run-up time; >80% light output in 10 seconds.

• Instant restart; <0.1 seconds.

• High frequency operation; no flickering, noise or stroboscopiceffect.

Mounting Flange

Fluorescent Coating

HF Generator

Heat Conduction Rod

Coil

Ferrite Core(inside)Antenna

Coaxial Cable

{

Induction Lamp ConceptThe induction fluorescent lamp is a state-of-the-art source, utilizing no electrodes or filament as in conventional discharge or incandescentsources. In this lamp, light is generated by means of induction – the transmission of energy via a magnetic field – combined with gasdischarge. This produces a highly efficient, extremely long-lived source that starts very quickly with little deterioration over its rated life.

H

Not to scale

27.5' 15' 21.7 12.7 7.81 7.89 7.85 7.94 12.2 1.56 2.78

27.5' 30' 17.1 4.10 3.25 4.48 3.23 4.49 7.54 2.33 5.29

27.5' 15' 17.2 11.2 7.44 7.49 7.39 7.45 10.53 1.42 2.33

27.5' 30' 14.0 4.45 3.69 4.75 3.64 4.68 6.94 1.91 3.85

27.5' 15' 15.1 10.9 7.81 7.78 7.77 7.73 10.14 1.31 1.95

27.5' 30' 11.7 4.55 3.92 4.73 3.89 4.72 6.38 1.64 3.01

30' 15' 21.3 12.3 6.75 6.79 6.74 6.76 11.36 1.69 3.16

30' 30' 16.8 3.90 2.85 3.77 2.84 3.76 7.08 2.49 5.92

30' 15' 17.9 11.8 7.32 7.34 7.28 7.33 10.72 1.47 2.46

30' 30' 13.7 4.17 3.23 4.04 3.22 3.99 6.43 2 4.25

30' 15' 15.8 11.6 7.78 7.79 7.74 7.77 10.42 1.35 2.04

30' 30' 11.3 4.29 3.5 4.15 3.47 4.12 5.94 1.71 3.26

Maintained IlluminationIncludes 32% effective ceiling reflectance (40% surfacereflectance, with 24" D structural beams).

NOTE: Contributions from adjacent bays included inareas shown.

_

Page 19: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

KIM LIGHTING 17

Related Products

AR/SAR STL LLF AFL

ET AC WF WD

Top Deck Lighting Stairway, Ramp, and Perimeter Lighting

Application Engineering Services

Applications Assistance

Kim Lighting utilizes the latest computer technology and softwareto provide specifiers with reliable evaluations of lighting systemperformance.

Kim can analyze a proposed luminaire layout or providerecommendations based on performance criteria.

Hard copies of plans can be sent directly to the Kim ApplicationsDepartment via fax, express or regular mail. Any .dwg or .dxf filecan be e-mailed ([email protected]), or placed onCD and forwarded to Kim Lighting, c/o Applications Dept.

Photometric Files

Kim Lighting electronic photometric files include .pdf file formatpages for printing and .ies files for use in lighting calculationsoftware. The complete .ies / .pdf library is available on theinternet at www.kimlighting.com.

Page 20: Parking Gara g e Luminaires 100 - 150 Watt HID • 85 Watt ...Parking Garag e Luminaires 100 - 150 Watt HID • 85 Watt Induction PGL4. PGL4 Proven Success SITE / AREA PARKING STRUCTURE

PGL4P a r k i n g G a r a g e L u m i n a i r e s

Hubbell Lighting, Inc.

How may we serve you better? Let us know by visiting our web site at:

www.kimlighting.com

Your input is valuable to us.

Because of a continuing product improvementprogram, Kim Lighting reserves the right tochange specifications without notice.

www.kimlighting.com