2
7/27/2015 Parker Electromechanical Automation FAQ Site | ACR Controllers | PC Card Controllers | Watchdog relay function http://parkermotion.com/dmxreadyv2/faqsmanager/faqsmanager.asp?question=551 1/2 Parker Electromechanical Automation FAQ Site » ACR Controllers » PC Card Controllers » Watchdog relay function General Motion Control Xpress Solutions XPR2 + C3 + ETH ACR Controllers 9000 PC Card Controllers IEC PLC (9600) PAC IPA Drive/Controller Aries Drive Controller (CE) Drive only (AE,AR, SE, SR) EPL Bayside / Gearheads Compax3 CTC/HMI Industrial Monitor (PHM / PM1) IPX / IPC Interact InteractX InteractXpress Daedal Positioning Systems MX80 IForce Linear Servo Motors & Positioners Ripped Series Linear Motors & Positioners Dynaserv ESeries Gemini OEM Products 6K Servo Motors Step Motors home | products | how to buy | support & downloads | literature | search Watchdog relay function The Watchdog relay for the ACR controller cards (except the ACR1500) is a dry contact reed relay. The contacts are rated at +24VDC @ 1.0 A. These contacts are not AC rated. The Watchdog outputs of the ACR1500 are OpenCollector Output and are rated at +24VDC @ 30 mA. The emitter of these outputs is connected to the 5VDC common power applied to the ACR1500. This relay is accessed through the P2 connector. The connections are labeled WDCOM (Watchdog Common), WDNO (Watchdog Normally Open) and WDNC (Watchdog Normally Closed). This relay is intended to be used in safety interlock circuits used in a system operated by an ACR controller card. The Watchdog relay is energized when power is applied to the ACR card and passes a DSP function check. NOTE: The 5 volt power applied to the DSPs used with ACR controller cards has a rating of +5VDC +/ 0.2VDC. The card will not operate in low voltage conditions. << Go Back

Parker Electromechanical Automation FAQ Site _ ACR Controllers _ PC Card Controllers _ Watchdog Relay Function

Embed Size (px)

DESCRIPTION

watch

Citation preview

  • 7/27/2015 ParkerElectromechanicalAutomationFAQSite|ACRControllers|PCCardControllers|Watchdogrelayfunction

    http://parkermotion.com/dmxreadyv2/faqsmanager/faqsmanager.asp?question=551 1/2

    ParkerElectromechanicalAutomationFAQSiteACRControllersPCCardControllersWatchdogrelayfunction

    GeneralMotionControlXpressSolutionsXPR2+C3+ETHACRControllers

    9000PCCardControllersIECPLC(9600)

    PACIPADrive/ControllerAriesDrive

    Controller(CE)Driveonly(AE,AR,SE,SR)EPL

    Bayside/GearheadsCompax3CTC/HMI

    IndustrialMonitor(PHM/PM1)IPX/IPCInteractInteractXInteractXpress

    DaedalPositioningSystems

    MX80IForceLinearServoMotors&PositionersRippedSeriesLinearMotors&Positioners

    DynaservESeriesGeminiOEMProducts6KServoMotorsStepMotors

    home|products|howtobuy|support&downloads|literature|search

    Watchdogrelayfunction

    TheWatchdogrelayfortheACRcontrollercards(excepttheACR1500)isadrycontactreedrelay.Thecontactsareratedat+24VDC@1.0A.ThesecontactsarenotACrated.TheWatchdogoutputsoftheACR1500areOpenCollectorOutputandareratedat+24VDC@30mA.Theemitteroftheseoutputsisconnectedtothe5VDCcommonpowerappliedtotheACR1500.ThisrelayisaccessedthroughtheP2connector.TheconnectionsarelabeledWDCOM(WatchdogCommon),WDNO(WatchdogNormallyOpen)andWDNC(WatchdogNormallyClosed).

    ThisrelayisintendedtobeusedinsafetyinterlockcircuitsusedinasystemoperatedbyanACRcontrollercard.TheWatchdogrelayisenergizedwhenpowerisappliedtotheACRcardandpassesaDSPfunctioncheck.

    NOTE:The5voltpowerappliedtotheDSPsusedwithACRcontrollercardshasaratingof+5VDC+/0.2VDC.Thecardwillnotoperateinlowvoltageconditions.

  • 7/27/2015 ParkerElectromechanicalAutomationFAQSite|ACRControllers|PCCardControllers|Watchdogrelayfunction

    http://parkermotion.com/dmxreadyv2/faqsmanager/faqsmanager.asp?question=551 2/2

    SearchKnowledgebase Search

    ViXZetaLegacy

    BLOKMPAServoDrivesTBF&TBNServoDrivesSFDServoDrivesMPFLXiBEAPEX&APEX615xMotionArchitectCompucamRP2406000XWare/XLanguageS/SXDrivesTQ10&TQ10XZZXZXFDrivesDigiplanBD,BDS,BDHX,BL,BLX,BLHX,PDS,PDX,PDHXSLVD&HPD4000L20PC21

    Other

    ParkerHannifinCorporation,ElectromechanicalAutomationDivision,5500BusinessParkDrive,RohnertPark,CA949287075847558or8003589068Email:TechnicalSupportCopyrightParkerHannifinCorporation2011