Page 2: para-test - APCO AVIATION: setting future standards · para-test.com Air Turquoise SA Rte du Pré-au-Ccmte 8 1 CH-lBiIiI Vileneuve ... EP 022.2009 MD SLT 20 130 kg ... info@para-test.com

para-test.comAir Turquoise SA

Rte du Pré-au-Ccmte 8 1 CH-lBiIiI Vileneuvetel -Ll121 9656565 1 mobae .Ll179 202 52 30

in/oDpara-lest.com

Fliaht and Load test report - EN 12491 :2001

ManufacturerAddress

APCO Aviation Inc.7, Chalamish St., Industrial park38900 CaesareaIsrael

Certification number:

Type/model:Total weight in flight:

EP 021.2009MD SLT 18

~

DescriDtion of tests 1 place:date:resu/t:

1. Deployment system strength test A load of 700 N between each components

Villeneuve05.08.2009OK

2. Speed of opening test - ref. A (2 times)

Time from the instant of free drop until a loadof 200 N is sustainedOpening time

Villeneuve31.03.2009< 5 seconds

Openinq time

Villeneuve21.04.2009< 5 seconds

3. Descent rate and stability test - ref. A and B (2 times) The paraglider is released as the parachutebegins to open, minimum 100 m descent.Stability 1

Villeneuve31.03.2009Stable

Sink rate 1

Villeneuve31.03.20095.10 mIs

Stability 2

Villeneuve21.04.2009Stable

Sink rate 2

Villeneuve21.04.20095.07 mIs

4. Strength test 40 mis opening shock (2 times) The drop test device is accelerated to astraight line velocity of 40 mIs and theparachute deployment handle activated usinga static line attached to a drogue chute. Speedof opening is less than 5 secondsTest 1

Monthey01.07.2009OK

Test 2

Monthev01.07.2009OK

5. Interaction and stability test (piloted) - ref. C a the emergency parachute is deployed from aparaglider in normal straight flight.

not available

b the pilot shall take no action while the behaviour of the parachute and paraglider areobserved 200 metres.

not available

c the pilot take action while the behaviour of the parachute and paraglider are observed 200metres.

not available

The model described is in conformity with the f1ight and load tests carried out by Air Turquoise SA.

Air Turquoise SARoute du Pré-au-Comte 8

Case postale 10CH- 1844 Villeneuve

email: [email protected]

No 71.4.1

Rév. 1, 10.11.2008

homepage: www.para-test.com

Page 1 of 2

Page 3: para-test - APCO AVIATION: setting future standards · para-test.com Air Turquoise SA Rte du Pré-au-Ccmte 8 1 CH-lBiIiI Vileneuve ... EP 022.2009 MD SLT 20 130 kg ... info@para-test.com

para-test .cem..;-

Weather data, ref. 3 and B

Air Turquoise SARte du Pré-au-Comle BI CH-I81111 Vileneuvetel. .4121 9656565 1 mobile .4179 2œ Sè 30

in/oQJpa'a-tesl.com

21/04/2009 Villeneuve

Reference

hPa968

Corrected mass: 1 m971.4

Corrected mass: 1 1""6'9."i'1

windo

o

A. At horizontal airspeed 8 mIs and vertical speed 1.5 mIs

B. Formula to be used for correctinq the test mass ofr differences from ICAO standard atmosphere

poT 0

rncorr:= rndec" p O"T

Ground level atmospheric pressure at the test location: (p)

ICAO standard atmospheric pressure at MSL: (po)

Ground level température at the test location: (T)

ICAO standard temperature at MSL: (To)

Total weight in tlight: (mdec)Corrected mass: (mcorr)

C. Onlv parachute with controls for steerinq and landinq tiare

Air Turquoise SARoute du Pré-au-Comte 8

Case postale 10CH - 1844 VilleneuveSwitzerlandmobile: +41 79 202 52 30Tel. no: +41 21 9656565fax: +41 219656568

email: [email protected]: www.para-test.com

No 71.4.1

Rév. 1, 10.11.2008 Page 2 of 2

Page 4: para-test - APCO AVIATION: setting future standards · para-test.com Air Turquoise SA Rte du Pré-au-Ccmte 8 1 CH-lBiIiI Vileneuve ... EP 022.2009 MD SLT 20 130 kg ... info@para-test.com

para-test .com

Jif 11 1 If ~ f' .1 t. ,- .'

Air TLXquoise SARte du Pré-au-Comte 8 1 CH-1844 Vileneuvelei. .41 21 96S 6S 6S 1 mobile.41 79 202 52 30

intcQtpara-lest.com

Fliaht and Load test report - EN 12491 :2001

ManufacturerAddress

APCO Aviation Inc.

7, Chalamish S1., Industrial park38900 CaesareaIsrael

Certification number:

Type/model:Total weight in flight:

EP 022.2009MD SLT 20

130 kg

Description of tests 1 place:date:result:1. Deployment system strength test A load of 700 N between each components

Villeneuve05.08.2009OK

2. Speed of opening test - ref. A (2 times)Time from the instant of free drop until a loadof 200 N is sustainedOpening time

Villeneuve31.03.2009< 5 secondsOpening time

Villeneuve21.04.2009< 5 seconds3. Descent rate and stability test - ref. A and B (2 times) The paraglider is released as the parachutebegins to open, minimum 100 m descen1.Stability 1

Villeneuve31.03.2009StableSink rate 1

Villeneuve31.03.20094.48 misStability 2

Villeneuve21.04.2009StableSink rate 2

Villeneuve21.04.20095.15 mis4. Strength test 40 mis opening shock (2 times) The drop test device is accelerated to astraight line velocity of 40 mis and theparachute deployment handle activated usinga static line attached to a drogue chute. Speedof opening is less than 5 secondsTest 1

Monthey01.07.2009OKTest 2

Monthey01.07.2009OK

5. Interaction and stability test (piloted) - ref. C a the emergency parachute is deployed from aparaglider in normal straight fligh1.

not availableb the pilot shall take no action while the behaviour of the parachute and paraglider areobserved 200 metres.

not availablec the pilot take action while the behaviour of the parachute and paraglider are observed 200metres.

not available

The model described is in conformity with the f1ight and load tests carried out by Air Turquoise SA.

Air Turquoise SARoute du Pré-au-Comte 8

Case postale 10CH- 1844 Villeneuve

email: [email protected]

No 71.4.1

Rév. 1, 10.11.2008

For Air Turquoise SA

homepage: www.para-tes1.com

Page 1 of 2

Page 5: para-test - APCO AVIATION: setting future standards · para-test.com Air Turquoise SA Rte du Pré-au-Ccmte 8 1 CH-lBiIiI Vileneuve ... EP 022.2009 MD SLT 20 130 kg ... info@para-test.com

para-test.com'r' .."

Weather data, ref. 3 and B

, • t Ji 1 f IJ, t· 1 •• ~ ~

Air Turquoise SARte du Pré-au-Comte 8 1 CH-I8L1L1Vileneuvetel. -Ll121 965 65 65 1 mobile -Lll 79 2œ 52 30

il"lloepara-test.com

21/04/2009 Villeneuve

Reference

hPa968

Corrected mass: 1 125'9'7"1':"4

Corrected mass: 1 122.9

windo

o

A. At horizontal airspeed 8 mis and vertical speed 1.5 mis

B. Formula to be used for correctinQ the test mass ofr differences fram ICAO standard atmosphere

p·T 0mcorr:=mdec'--

p O·T

Ground level atmospheric pressure at the test location: (p)

ICAO standard atmospheric pressure at MSL: (po)

Ground level température at the test location: (T)

ICAO standard temperature at MSL: (To)

Total weight in flight: (mdec)

Corrected mass: (mcorr)

C. Onlv parachute with controls for steerinQ and landinQ flare

Air Turquoise SARoute du Pré-au-Comte 8

Case postale 10CH - 1844 VilleneuveSwitzerlandmobile: +41 79 202 52 30Tel.no:+41 21 9656565fax: +41 219656568

email: [email protected]: www.para-test.com

No 71.4.1