12
CyFlow ® ML CyFlow ® space Immunology | Haematology Pathology | Microbiology Industrial Applications Cell Biology | Cell Sorting Multilaser 16|9 Parameters Desktop FCM Systems

PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

  • Upload
    lytruc

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

CyFlow® MLCyFlow® space

Immunology | Haematology

Pathology | Microbiology

Industrial Applications

Cell Biology | Cell Sorting

Multilaser 16|9 Parameters Desktop FCM Systems

Page 2: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

2

More than 40 Years of Experience and Professional Expertise

Partec (established 1967)—pioneer in Flow Cytometry since more than 40 years—responds to these requirements with the newest generation of CyFlow® analyzers and CyFlow® sorters featuring innovative computer controlled fluidic systems, modular optical bench systems with advanced PMTs for all optical channels, most modern computer and digital electronic technologies as well as realtime data acquisition and realtime data display.

In more than 100 countries worldwidewww.partec.com/worldwide

01 COMPANY

Flow Cytometry made in Germany

New sophisticated applications and increasing require-ments for reliable results in research and routine with-in the shortest possible time. The challenge for Flow Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry.

Page 3: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

3

02 INTRODUCTION

Excellence in Flow Cytometry

Ultracompact desktop high-end instruments

_ Parallel 16 bit digital pulse processing_ High fluorescence sensitivity: < 100 MESF (FITC) | < 50 MESF (PE)_ Submicron particle detection | < 0,2 µm for scatter_ RobbyWell™ Autoloader option_ True volumetric absolute counting

_ Windows™ FloMax® software for realtime data aquisition, data display and data evaluation_ Automated software compensation online and offline

_ 16 optical parameters: FSC1, FSC2, SSC, FL1–FL13_ Up to 5 light sources_ 488 nm blue solid state laser (200 mW, 50 mW or 20 mW)_ 638 nm red diode laser (25 mW or 40 mW)_ 407 nm violet diode laser (100 mW)_ Choice of UV, green and yellow lasers_ High power UV LED for highest resolution DNA analysis_ Flexible and modular system configurations

CyFlow® ML

Dimensions (cm): L 56 x W 65 x H 30 (stand alone)

Both feature:

Multilaser 16 Parameters— 13 Colors Desktop Flow Cytometer

_ 9 optical parameters—7 colors: FSC, SSC, FL1–FL7_ Up to 3 laser light sources_ 488 nm blue solid state laser (200 mW, 50 mW or 20 mW)_ 638 nm red diode laser (25 mW or 40 mW)_ 407 nm violet diode laser (100 mW)_ 375 nm UV laser (16 mW)_ Other lasers optionally available (green, yellow, etc.)_ Cell sorter upgrade option

Dimensions (cm): L 56 x W 65 x H 30 (stand alone)

3-Laser 9 Parameters—7 Colors Desktop Flow Cytometer

CyFlow® space

Page 4: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

4

The design of the flow cuvette incorporates more than

40 years of experience in handling fluids with sub-micro-

meter and nanoliter precision. Thanks to the optical and

mechanical precision of the flow cuvette, superior results are

guaranteed for all parameters, e.g. coefficients of variation (CVs)

of about 2% on all fluorescence channels. The sample is trans-

ported with the help of a computer controlled syringe pump,

part of a virtually cross-contamination-free fluid system.

The Partec CyFlow® Sorter is the result of more than 40 years of

experience in the field of Flow Cytometry for research and routine

applications in cell and particle characterization. The sorter is

used as an add-on to the Partec CyFlow® space and serves as an

optimized module for simplified and precise cell sorting.

In order to overcome the problems of droplet sorters (bio-

hazard, contamination) Partec has developed this closed

sorting system. The sorting device can be sterilized safely.

Any environmental contamination is completely avoided

under normal operation conditions. In addition, the sorting

action takes place smoothly. Fragile cells or large particles

are sorted without any distortion and other forces acting on

the cells during deflection. Long sorting runs (for several

hundred milliliters of sample volume) are possible.

The Partec Sorter has a Flow Chamber with a piezo element

and an electronic device for piezoelectric activation. The dia-

mond piezo deflects the sorted cells into a second branch of

the flow cell (see sorting scheme opposite page above).

CyFlow® Sorter as built-in module for safe closed piezo sorting offering highest purity and sorting stability.

Partec Quartz Flow Cuvette

The unique Partec quartz flow cuvette is the heart of the CyFlow® ML/space, ensuring that particles and cells cross the excitation light with the best possible precision.

FORWARD SCATTER

SAMPLESHEATH FLUID (HYDRODYNAMIC FOCUSING)

BLUE SOLID STATE LASER

RED DIODE LASER

UV OR VIOLET DIODE LASER

HIGH NA OBJECTIVES

Page 5: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

5

During piezoelectric activation, a pressure wave is generated

and, as a consequence, a small volume of sheath fluid is

deflected together with the cell or particle of interest. The

piezo activation of the sorting process is repeated each time

there is a cell to be sorted, according to the acquisition signals.

In the sample flow each cell is analyzed and all the signals

reach the computer, where the decision is made which cell

should be sorted, according to any software gating.

Special feature of the CyFlow® Sorter is the correct sorting

of ALL the cells in a region. The high yield is a result of the

practically zero dead time data acquisition system. No event

is lost because all Partec hard- and software acquisition work

without any “interrups”. In addition, in this way no “wrong” cell

can be sorted by mistake, achieving directly highest purity.

The Partec sorting principle is utmost stable, lasting,

constant, and without vibrations, because the whole system

is closed, non-elastic, and without air. The delay time setting

can be controlled easily on the CCD camera screen, no

microsopic check is needed. The Partec sorter works with

low pressure differences in the capillary system. The mor-

phology and vitality of cells (for e.g. most fragile particles

like plant protoplasts) are not influenced by sorting.

As far as the control of the sorting process is concerned,

Partec instruments have the advantage of an extremely

precise and stable system control of the time delay between

measurement and piezo activation. Another unique feature of

Partec instruments is the built-in CCD camera, which allows

an easy check of the whole process directly in the monitor of

the instrument, this is also maintained while sorting (See the

photograph above: CCD camera shot of the sorting process.

Sorted cells are deflected to the upper right).

Sorting Control Unit

Setting of sorting parameters for piezo crystal energy, delay,

slope, and hold time. Direct connection to processor.

Sorting speed

Input up to 10,000 cells per second, for highest purity (99%)

of sorted fraction up to 100 cells per second (300 cells per

second at 95% puritiy).

Sorting flow cell specifications

Completely closed quartz type flow cell with 200 microns

sorting channel for particle sizes up to 60 microns diameter

(other sorting channel dimensions optional).

Sorting action

Piezo crystal for controlled particle deviation. Adjustable

delay between point of analysis and deflection.

CyFlow® Sorter Module

DIAMOND PIEZO FOR CLOSED CELL SORTING

Page 6: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

6

Laboratories demand highest flexibility for upcoming applications. The CyFlow® ML/space open system architec-ture is designed for today and the future.

Taking advantage of most recent computer and electronic technologies

Each optical channel is equipped with an independent processor

controlled digital pulse analyzer for parallel pulse processing in

order to minimize signal losses due to coincidence and dead-

time effects. 16 bit (65536 channels) analogue-to-digital conver-

ters for each parameter are the fundament for software-based

color crosstalk compensation algorithms and other numerical

operations, e.g. fluorescence ratio measurements, with out artif-

acts. The computing power of the CyFlow® ML/space system

allows signal analysis, processing and display of each event

generated by a particle in realtime, which is a prerequisite for

precise high speed analysis and accurate absolut counting.

All-in-one design and modular extension for future cytometric analysis

The CyFlow® ML/space in its ultracompact design incorpo-

rates all modules and components within smallest dimen-

sions of L 56 x W 65 x H 30 [cm]. In contrast to other avail-

able FCM systems, the CyFlow® line of instruments does

not require any external equipment. Power supply, pressure

regulators and the fluidic system are completely built-in.

Additional space beside or under your laboratory desk is not

any longer required. In order to be prepared for future appli-

cations, the CyFlow® ML/space offers flexible and modular

configurations in a most compact system architecture.

Page 7: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

7

The True Volumetric Absolute Counting (TVAC) is a unique feature of all Partec Flow Cytometers, offering highest absolute counting precision and accuracy.

Selection of Fluorochromes for the CyFlow® ML/space Light Source System

The CyFlow® ML/space features True Volumetric Absolute

Counting for precise cell and particle enumeration. This

unique method is based on the fundamental definition of

absolute counts respectively the particle concentration

(c = N/V). In the CyFlow® ML/space, the sample volume

is measured directly by mechanical means, rather than

by calibration with oftenly expensive beads with a “given”

nominal concentration. Thus, the volume measurement is

eliminating any error influence related to eventually varying

bead concentrations or bead aggregations. The CyFlow® ML/

space allows the analysis of a fixed volume as defined by the

distance between two platinum electrodes. Alternatively,

a well defined volume of free choice involving the digital

sample speed control can be used. Benefits of True Volumetric

Absolute Counting:

_ digital volumetric precision by mechanical design: CV < 2%

_ no errors related to calibration _ no additional time and preparation steps_ no expenses for calibration beads _ no separate haematology counter required

Excitation (nm) Detector Exemplary Dyes Exemplary Dyes Exemplary Dyes Exemplary Dyes Exemplary Dyes Exemplary Dyes Exemplary Dyes Exemplary Dyes

Blue 488 Green FITC GFP Alexa Fluor 488 Syto 9-24 Oregon Green JC-1 (monomers) DiOC6(3) H2-DCF-DA

Orange PE YFP Hydroethidine

Orange Red PE-Texas Red PI ECD EB JC-1 (aggregates)

Red I PE-Cy5 PerCP PE-Dy647 Acridine Orange 7-AAD

Red II PE-Cy5.5 PerCP-Cy5.5

Far Red PE-Cy7

Red 638 Red I APC APC-Cy5 Syto 59-63 Dy647 TO-PRO3 Alexa Fluor 647 Draq5 Cy5

Red II APC-Cy5.5 Cy5.5

Far Red APC-Cy7 APC-H7 Alexa Fluor 750 Cy7

Violet 407 Blue Pacific Blue Alexa Fluor 405 Monobromobimane Hoechst 33342

Green AmCyan CFP Qdot 525 Lucifer Yellow

Orange Cascade Yellow Pacific Orange Qdot 585

UV LED365

UV Laser355375

Blue DAPI Hoechst 33342 Alexa Fluor 350 Cascade Blue BFP AMCA Indo-1 (Ca++)

Green Qdot 525

Orange Qdot 585 Indo-1 (no Ca++)

Green 532 Orange mStrawberry DsRed DY590 mOrange

Red mCherry LDS 751

Yellow 561 Orange PE Dy590 Philippin Cy3 mBanana

Red PE-Cy5 PI LDS 751

Orange 594 Orange Red Texas Red Alexa Fluor 594

Red APC mCherry Cell Tracker Red

Far Red APC-Cy7 mPlum mRaspberry mKate Katushka HCRed HCRed

Page 8: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

03 OVERVIEW

Fields of Applications

Overview of applications and upgrade options for CyFlow® ML and CyFlow® space

CyFlow® ML CyFlow® space

Healthcare Immunology, Hematology, Pathology, Cancer Research, DNA Analysis

MicrobiologyCell Counting & Live/Dead Analysis in Biotechnology and Cell Culture,

Toxicology, Biomonitoring, Virus Detection, Research

Industrial Applications Quality Control in Food and Beverage Industry, Yeast Analysis, Fermentation Control,

Process Optimization, Particle Counting, Particle Size Distribution

Agrosciences Ploidy Analysis, Plant Genome Size, Apomixis

Cell Counting eukaryotic cell cultures (mammalian cell cultures | plant cell cultures),

prokaryotic cell cultures, leukocyte counting in depleted blood products, counting of immunolabelled subtypes, sperm cell counting

Functional Assays cell cycle and cell proliferation, viability | Live/Dead cell counting, apoptosis

Wine Industry Rapid and Automatic Detection, Quantifi cation and Live/Dead Analysis

of Yeasts in Wine & Champagne

HIV Monitoring and AIDS Patient Follow-up Diagnostics | Dedicated,

Accurate and Affordable CD4 and CD4% Testing for Adults and Children

Cell Sorting

Options & Upgrades RobbyWell™ Autoloader RobbyWell™ Autoloader CyFlow® Sorter for closed and non-hazardous, non-destruc-tive cell and particle sorting

Notes High-End FCM system for a wide range of applications

High-End FCM system for a wide range of applications and cell sorting

8

Page 9: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

Full flexibility and automation by the multi-tube FloMax® panel system and the FloMax® Report system within the FloMax® software package.

Ready prepared and freely adaptable instrument settings

and panels facilitate switching between different applica-

tions. FloMax® is optimized for immunophenotyping, micro-

biology analysis, cell cycle, DNA ploidy, and scientific flow

cytometric analysis. Data are stored in FCS Flow Cytometry

standard file format for easy exchange with other analysis

software. One of the unique features is the digital on- and

offline color crosstalk compensation of the spectral over-

lap of fluorescence from simultaneously analyzed dyes.

The N-color compensation algorithm allows a correc-

tion of the crosstalk between any parameters without the

need of rerunning a sample. FloMax® optimally supports

the True Volumetric Absolute Counting feature of the

CyFlow® ML/space, displaying particle concentrations for

any subsets of cells, even if defined by a gate at a later time

after the acquisition.

The flexible FloMax® Panel system allows automated analy-

sis of repeating sample series employing different dyes or

instrument settings. The FloMax® Report system generates

easy-to-adapt automated single or multi-tube panel results.

Reports are based on Microsoft Word or Excel written in

Visual Basic.

The Windows™ FloMax® software integrates instrument control including acquisition, on- and offline data analysis, on- and offline compensation into a complete software package.

04 ANALYZE

CyFlow® ML/space FCM System

9

Page 10: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

10

05 SPECIFICATIONS

CyFlow® ML/space FCM System

GENERAL_ compact flow cytometer for automated sequential analysis of single cells and microscopic particles_ scatter particle size range: 0.2 µm–200 µm_ fluorescence sensitivity: <100 MESF (FITC) < 50 MESF (PE) _ fluorescence resolution: CV < 2% _ configurations with up to 16/9 optical parameters + time parameter

LIGHT SOURCES_ up to 5/3 light sources_ blue solid state laser: 200 mW@488 nm_ red diode laser: 40 mW@635 nm_ violet diode laser: 100 mW@407 nm_ green DPSS laser 30/100 mW@532 nm_ yellow solid state laser 100 mW@561 nm_ UV LED 365 nm or ultra-violet diode laser 16 mW@375 nm_ other laser power and laser wavelengths available

OPTICS_ modular optical system with up to 16/9 optical

parameters with selected PMTs with integra-ted electronic preamplifier for CyFlow® ML: FSC1, FSC2, SSC, FL1-FL13CyFlow® space: FSC1, SSC, FL1-FL7

_ standard setup and filters_ color CCD camera for video flow monitor_ standard objective mount with high numerical aperture_ immersion gel coupling, e.g. for detection of weak cytokines (option) _ separated intermediate image planes for optimized spatial filtering by diaphragms

FLOW SYSTEM_ synthetic quartz flow cuvette for laminar sample transport with sheath fluid

_ sample port with computer controlled BioSafety cleaning system, avoids sample droplets and minimizes cross contamination_ True Volumetric Absolute Counting based on mechanical volume measurement, no need for reference particles _ contamination-free computer controlled precision syringe pump for sample transport and True Volumetric Absolute Counting, pump speed continuously adjustable from 0-50 µl/s, sheath fluid pressure continuously adjustable from 0-800 mbar_ easily accessible sheath fluid and waste

reservoirs with fluid level sensors

ELECTRONICS _ parallel signal processing for each of the optical channels with selectable linear, 3- or 4-decade logarithmic scale_ pulse height, area, and width analysis for doublet discrimination _ 16 bit analog-to-digital converters, trigger on any parameter or parameter combinations

COMPUTER _ latest industry standard computer _ 19" TFT LCD display_ CCD video camera _ dual screen setup (optional)_ DVD-RW_ keyboard, mouse, barcode reader (optional)_ 100 MB/s and 1000 MB/s Ethernet connection_ DeskJet color printer, b&w or color laser printer (optional), printing via network

SOFTWARE_ Microsoft Windows™ operating system with full network support _ Apple® Macintosh network connection (optional)_ 32 bit Windows™ FloMax® software for routine and research applications_ 64 parameter realtime data acquisition

and analysis

_ 3-spot acquisition from spatially separated light sources with time-window delay system

_ internal floating point numerics with double precision

_ one and two parameter histograms and dotplots_ 64—32768 channels resolution for 1P histograms_ 32/32—1024/1024 channels for 2P dotplots_ multiparameter N-colors crosstalk compen-

sation, settings may be corrected at any time_ multiparameter ColorGating_ ratio measurement_ doublet discrimination based on pulse height, area, and width analysis_ peak and cluster analysis and statistics_ connection to 96 well plate automate_ DNA cell cycle analysis_ DNA peak analysis_ multitube panel system with automated

acquisition_ Flow Cytometry standard data format (FCS) for storage of original and evaluated data _ storage of gates and screen layout _ automated data transfer of graphics, statistics and instrument settings to Word, Excel, PowerPoint and other desktop publishing systems or laboratory information systems (LIS)

Length 560 mm

Width 650 mm

Length 560 mm

Hei

ght 3

00 m

m

Wid

th 6

50 m

mH

eigh

t 300

mm

For in vitro diagnostic use.

Page 11: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

11

High Quality—Made in Germany

Quality, perfor mance, precision

and affordability of Partec pro-

ducts profit from a unique produc-

tion depth realized at Partec for

manufacturing modules and com-

ponents in optics, electronics, laser

technology, fluidics, and mechanics.

Page 12: PAR Broschuere SpaceML 140410 CATALOGUES/Flow cytometers/CyML.pdf · Cytometry instrumen tation, automation and software. Partec. The pioneer of Flow Cytometry. 3 02 INTRODUCTION

ww

w.c

yclo

s-de

sign

.de

0

4.10

Microbiology/ Industrial Applications

Agrosciences/Animal Research/Aquaculture

Medical Diagnostics Diagnostics for HIV/AIDS, TB, Malaria

Partec GmbH Otto-Hahn-Straße 32 D-48161 Münster Germany

Phone +49 (0) 2534 8008-0 Fax +49 (0) 2534 8008-90 [email protected]

Partec GmbHAm Flugplatz 13D-02828 GörlitzGermany

Phone +49 (0) 3581 8746-0Fax +49 (0) 3581 8746-70 [email protected]

Partec North America, Inc.603 Heron Dr., Unit 9Swedesboro, NJ 08085USA

Phone 856 467 0018US toll-free 888 808 0067Fax 856 467 0188 [email protected]

Partec Japan, Inc.3628-46 KandatsuTsuchiura 300-0013Japan

Phone +81 29 834 7788Fax +81 29 834 [email protected]

Partec S.A.R.L.14/16 rue Gallieni 91700 Sainte Geneviève des Bois France

Phone +33 1 69 04 87 12 Fax +33 1 69 04 90 38 [email protected]

Partec UK LtdUnit 44Canterbury Innovation CentreUniversity RoadCanterburyKent CT2 7FGUnited Kingdom

Phone +44 1227 811711Fax +44 1227 [email protected]

Partec Nederland BVMiddenweg 591 B1704 BH HeerhugowaardNederland

Phone +31 72 5742427Fax +31 72 5710756 [email protected]

Partec West Africa SARL01 BP 1323OuagadougouBurkina Faso

Phone +226 50 30 45 59Fax +226 50 30 45 59 [email protected]

Partec Italia S.r.l.Via. G. Mascherpa 1420048 Carate BrianzaItalia

Phone +39 0362 909 143Fax +39 0362 909 157 [email protected]

Partec IndiaE-135, Ground FloorLajpat Nagar—INew Delhi—110 024India

Phone +91 11 4101 8787Fax +91 11 4650 [email protected]

Partec Afrique Centrale SARLRue Bebey Elame—AKWA DoualaB.P. 2326Douala Cameroon

Phone +237 33 42 76 12Phone +237 77 65 41 89Fax +237 33 42 76 [email protected]

Partec East Africa LtdN.H.I.F. Building, 2nd FloorRagati RoadCode 00517—Uhuru GardensNairobiKenya

Phone +254 20 272 7355Fax +254 20 272 7358 [email protected]

Partec Southern Africa (Pty) LtdUnit IFPlot 119Millenium ParkGaboroneBotswana

Phone +267 318 1844Fax +267 318 1841 [email protected]

Complete list of subsidiaries and distributors:

www.partec.com

Contact