GENSET Generating Set Powered By P800KVA9 Image for illustration purposes only Engine Make & Model Origin Alternator Type Control Panel Circuit Breaker Type Tropical Cooling System Digital Electronic Governor Turbocharged Exceptional Power to Weight Ratio No. of Cylinders / Alignment Cycle Aspiration Injection Bore, mm Stroke, mm Displacement,I Compression Ratio Starting Alternators, Amps Prime Power 640KWe / 800KVA UK Stamford HCI634G Deap Sea - 7310 3 Pole MCCB 6 / In Line 4 - Stroke Turbocharged Direct 160 190 22.921 13.6:1 24V Electric 24V/70A Standby Power 720KWe / 900KVA Engine Technical Data No. of Bearings Insulation System Excitation Voltage Regulator Protection Temperature Rise,°C Regulation No. of Phases No. of Poles Single Bearing Class H PMG MX321 IP23 125 ±0.5% 3 4 Alternator Technical Data H(m) 2.30 W(m) 1.80 L(m) 4.40 Weight(kg) 6300 Dimensions (m) & Weights (kg) International Standards 1500rpm, 50 Hz 88 132 175 Fuel System 50% 75% 100% Output Ratings Genset Specifications Generating Set Model 1500rpm, 50 Hz /400V 675KWe / 844KVA 750KWe / 938KVA 1800rpm, 60 Hz /440V Tank Capacity(L) N/A RATING GUIDELINES PRIME POWER rating corresponds to ISO Standard Power for continuous operation. It is applicable for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. A10 % overload capability for govering purpose is available for this rating. MAXIMUM STANDBY POWER rating corresponds to ISO Standard Fuel Stop Power. It is applicable for supplying standby electrical power at variable load in areas with well established electrical networks in the event of normal utility power failure. No overload capability is available for this rating. 1 hp = 1 kW x 1.36 Engine confirm to ISO 9001:2000, ISO 1400, ISO 10054, ISO 3046, BS 5514, DIN 6271. Alternator confirm to ISO 9001, ISO 14001, BS EN 60034, BS 5000, VDE 0530, NEMA MG32-1, IEC34 CSA C-22.2100, AS 1359, BS 1 6861, B En -6-610002:2001 Perkins 4006-23TAG3A 1800rpm, 60 Hz *Prime Power (l/hr) 96 144 200

P800KVA9 GENSET - aboudcar.com · GENSET Generating Set Powered By P800KVA9 Image for illustration purposes only Engine Make & Model ... Temperature Rise,°C Regulation No. of Phases

  • Upload
    dothuy

  • View
    221

  • Download
    0

Embed Size (px)

Citation preview

Page 1: P800KVA9 GENSET - aboudcar.com · GENSET Generating Set Powered By P800KVA9 Image for illustration purposes only Engine Make & Model ... Temperature Rise,°C Regulation No. of Phases

GENSETGenerating Set Powered By

P800KVA9Image for illustration purposes only

Engine Make & Model

Origin

Alternator Type

Control Panel

Circuit Breaker Type

Tropical Cooling System

Digital Electronic Governor

Turbocharged

Exceptional Power to Weight Ratio

No. of Cylinders / Alignment

Cycle

Aspiration

Injection

Bore, mm

Stroke, mm

Displacement,I

Compression Ratio

Starting

Alternators, Amps

Prime Power

640KWe / 800KVA

UK

Stamford HCI634G

Deap Sea - 7310

3 Pole MCCB

6 / In Line

4 - Stroke

Turbocharged

Direct

160

190

22.921

13.6:1

24V Electric

24V/70A

Standby Power

720KWe / 900KVA

Engine Technical Data

No. of Bearings

Insulation System

Excitation

Voltage Regulator

Protection

Temperature Rise,°C

Regulation

No. of Phases

No. of Poles

Single Bearing

Class H

PMG

MX321

IP23

125

±0.5%

3

4

Alternator Technical Data

H(m)

2.30

W(m)

1.80

L(m)

4.40

Weight(kg)

6300

Dimensions (m) & Weights (kg)

International Standards

1500rpm, 50 Hz 88 132 175

Fuel System 50% 75% 100%

Output Ratings

Genset Specifications

Generating Set Model

1500rpm, 50 Hz /400V

675KWe / 844KVA 750KWe / 938KVA1800rpm, 60 Hz /440V

Tank Capacity(L)

N/A

RATING GUIDELINESPRIME POWER rating corresponds to ISO Standard Power for continuousoperation. It is applicable for supplying electrical power at variable load for anunlimited number of hours instead of commercially purchased power. A10 %overload capability for govering purpose is available for this rating.MAXIMUM STANDBY POWER rating corresponds to ISO Standard FuelStop Power. It is applicable for supplying standby electrical power at variable load inareas with well established electrical networks in the event of normal utility powerfailure. No overload capability is available for this rating. 1 hp = 1 kW x 1.36

Engine confirm to ISO 9001:2000, ISO 1400, ISO 10054, ISO 3046, BS 5514, DIN 6271.Alternator confirm to ISO 9001, ISO 14001, BS EN 60034, BS 5000, VDE 0530, NEMAMG32-1, IEC34 CSA C-22.2100, AS 1359, BS 1 6861, B En -6-610002:2001

Perkins 4006-23TAG3A

1800rpm, 60 Hz

*Prime Power (l/hr)

96 144 200

Page 2: P800KVA9 GENSET - aboudcar.com · GENSET Generating Set Powered By P800KVA9 Image for illustration purposes only Engine Make & Model ... Temperature Rise,°C Regulation No. of Phases

GENSETGenerating Set Powered By

P800KVA9

Alternator Efficiency

Optional Equipment

Spare Parts Kit (Optional) Genuine - Perkins

Oil filter, full flowFuel filterAir filterFan belt setAlternator belt set

(2)(1)(1)(1)(1)

0.25% of fuelconsumption

Oil Consumption (l/hr)

Oil Sump Capacity,I

Oil System Capacity Include Filters, I

Lubrication System 1500rpm

Engine PowerPrime Power, KWm(hp)Standby Power, KWm(hp)

AlternatorPrime Power, KWe

94.4%

679(910)760(1019)

648

Performances 1500rpm

94.5%

715(959)795(1066)

740

-

113.4

90

1800rpm Control Panel Readings

1800rpm

86

315

1200

73(2578)

741

500

6.0

193(6815)

1500rpm

1500rpm 1800rpm

105

1800rpm

Anti-Vibration Pads

Cooling System

Heat Radiation from Engine and Alternator, Power KW (Standby)

Heat Rejection to Coolant and Lube Oil at Standby Power, KW

Radiator Cooling Air Flow, m3/min (cfm)

Coolant Capacity, I

Intake & Exhaust System

Air Flow Combustion at Standby Power, m3/min(cfm)

Heat Rejection Exhaust at Standby Power , KW

Exhaust Gas Temperature at Standby °C

Max Allowable Back Pres-sure in Exhaust Line, Kpa

Exhaust Gas Flow at Standb y Power, m3 /min(cfm)

Accessories

Stainless Steel Flexible

Standard Silencer

• AC volts, AC currents, DC volts, frequency, rpm, hour counter, power factor.• Low oil pressure, high water temparature, boost pressure and temperature, KW, KWh, KVA, KVAR, fuel consumption, relative load• Oil pressure, water temparature, low oil level, high oil temperature• DC alternator failure, over speed, over crank (Fail to start), over under voltage, over under current, any sensor failure• Low coolant level - Configurable inputs&outputs• Upgradable for GSM network connection, Signal SMS messages.

330

1320

78(2554)

759

500

6.0

209(7380)

•Engine-Coolant heater-Oversize batteries-Extra fuel pre-filter water separator• Alternator-12 wire reconnectable stator/terminal arrangement-Upgrade to AVR MX321-Qadrature droop kit-Anti-condensation heater-Air inlet filters• General-Upgrade to modular controller for paralleling-Upgrade to ACB-Battery charger-Automatic transfer switch-Fuel level switch High / Low for alarm and control-Fuel transfer pump Automatic / Manual-Residential grade silencer-Weather protective and acoustic enclosure.

Battery Disconnector Switch