K300-NZM 10 K2x120-NZM 10 K2x240-NZM 10 RG-NZM 10 K2x240W-NZM 10 K2x240 IP-NZM 10 P10(4)-... NZM 10(4)-...N/B NZM 10(4)-...(N)(S)(H) /ZM (M, V)-... (-NA) OFF ON TRIP 10 mm 5 mm PZD 2 Ø 2 mm 11/95 AWA123-1089 Montageanweisung Installation Instructions Notice d installation Istruzioni per il montaggio Instrucciones de montaje Electric current! Danger to life! Only skilled or instructed persons may carry out the following operations. The national regulations/specificationes must be observed for the installation of the devices. Tension lectrique dangereuse ! Seules les personnes qualifi es et averties doivent ex cuter les travaux ci-apr s. Veuillez respecter les normes de mise en oeuvre sp cifiques aux diff rents pays. Tensione elettrica: Pericolo di morte! Solo persone abilitate e qualificate possono eseguire le operazione di seguito riportate. Per l installazione degli apparecchi necessario rispettare le normative specifiche di ciascun paese. `Corriente el ctrica! `Peligro de muerte! El trabajo a continuaci n descrito debe ser realizado por personas cualificadas y advertidas. Para la instalaci n de los aparatos han de tenerse en cuenta las normativas/especificaciones a nivel local. Lebensgefahr durch elektrischen Strom! Nur Elektrofachkr fte und elektrotechnisch unterwiesene Personen d rfen die im Folgen- den beschriebenen Arbeiten ausf hren. Beachten Sie f r die Installation der Ger te die l nder- spezifischen Vorschriften. 1/11 For Immediate Delivery call KMParts.com at (866) 595-9616

P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

Embed Size (px)

Citation preview

Page 1: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

K300-NZM 10K2x120-NZM 10K2x240-NZM 10RG-NZM 10K2x240W-NZM 10K2x240 IP-NZM 10

P10(4)-...NZM 10(4)-...N/BNZM 10(4)-...(N)(S)(H) /ZM (M, V)-...(-NA)

OFF

ON

TRIP

10 mm 5 mm

PZD 2Ø 2 mm

11/95 AWA123-1089

MontageanweisungInstallation InstructionsNotice d installation

Istruzioni per il montaggioInstrucciones de montaje

Electric current! Danger to life!Only skilled or instructed persons may carry out thefollowing operations.The national regulations/specificationes must be observed for the installation of the devices.

Tension lectrique dangereuse !Seules les personnes qualifi es et averties doivent ex cuter les travaux ci-apr s.Veuillez respecter les normes de mise en oeuvre sp cifiques aux diff rents pays.

Tensione elettrica: Pericolo di morte!Solo persone abilitate e qualificate possono eseguirele operazione di seguito riportate.Per l installazione degli apparecchi necessario rispettare le normative specifiche di ciascun paese.

`Corriente el ctrica! `Peligro de muerte!El trabajo a continuaci n descrito debe ser realizado por personas cualificadas y advertidas.Para la instalaci n de los aparatos han de tenerse encuenta las normativas/especificaciones a nivel local.

Lebensgefahr durch elektrischen Strom!Nur Elektrofachkr fte und elektrotechnischunterwiesene Personen d rfen die im Folgen-

den beschriebenen Arbeiten ausf hren.Beachten Sie f r die Installation der Ger te die l nder-spezifischen Vorschriften.

1/11

123-1089 06.02.2002 15:04 Uhr Seite 1

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 2: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

75

210

280

70

4P

4 M6x50

1:2

3P

143,

512

4

245

250

286

90°

90°

90°

90°

OFF

ON

TRIP

2/11

OFF

ON

TRIP

min. 130 mm

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 2

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 3: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

A

B

B

A

OFF

ON

TRIP

OFF

ON

TRIP

OFF

OFF

ON

TRIP

1 2

3

2 3

MontageMountingMontageMontaggioMontaje

AuslöseblockTrip blockUnité de déclenchementSganciatoreBloque de disparo

ZM (M)(V)/B1

3/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 3

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 4: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

OFF

ON

TRIP

OFF

ON

TRIP

A

B

OFF

ON

TRIP

I r

OFF

ON

TRIP

t r

OFF

ON

TRIP

I rmv

OFF

ON

TRIP

B-NZM

ZM...

4 5

1 2

3 4

EinstellungenAdjustmentsRéglagesRegolazioniRegulaciones

ZM (M)(V)/B

lr

6xlrtrtr=20s

tr=6s

Irm

Irmv

tv

I>

I>I>

lr

6xlrtrtr=20s

tr=6s

Irm

Irmv

tv

I>

I>I>

lr

6xlrtrtr=20s

tr=6s

Irm

Irmv

tv

I>

I>I>

4/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 4

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 5: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

TRIP

tripped

push to trip

OFF

TRIP

OFF

ON

TEST 1 TEST 2

OFF

ON

TRIP

A

B

OFF

ON

TRIP

t v

OFF

ON

TRIP

I rm

5 6

7 8

lr

6xlrtrtr=20s

tr=6s

Irm

Irmv

tv

I>

I>I>

lr

6xlrtrtr=20s

tr=6s

Irm

Irmv

tv

I>

I>I>

Thermisches Gedächtnis - Verbraucher- und AnlagenschutzNach Auflösung durch Überstrom ist der NZM 10 nach x Minuten wieder einschaltbereit.

Thermal memory - user/system protectionThe NZM 10 is ready for closing x minutes after it has beentripped due to overcurrent.

Mémoire termique - protection des récepteurs et installationsAprès déclenchement sur surcharge, le NZM 10 peut êtreréarmé au bout de x minutes.

Memoria termica - protezione utillizzatori ed impiantiA seguito di sgancio dovuto a sovracorrenti, l’NZM 10 puòessere reinserito dopo x minuti.

Memoria térmica - protección del usuario y del sistemaEl NZM 10 está perparado para cerrar x minutos después de haberse disparado por sobreintensidad.

5/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 5

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 6: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

OFF

ON

TRIP

OFF

SVB-NZM 10

OFF

ON

TRIP

A

B

OFF

ON

TRIP

A

B

OFF

ON

TRIP

B

OF

TRIP

A

Ø 6...8 mmmax. 3x

1

3

2

AnschlüsseConnectionsConnexionsCollegamentiConexiones

TEST 3

6/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 6

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 7: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

A

B

B

A10 mm

B

A

10 mm50 Nm

B

A

K22 x 21

K2 x 120 K2 x 240

K300

S S

S

K22 x 21 K300

K2 x 240K2 x 120

SteuerleitungenControl cablesCâbles de commandeCavi comandiCables de control

1 2

3 4

S: 1x 120-300 mm2

1x 50-240 mm2

S: 2x 50-240 mm21x 70-120 mm2

S: 2x 70-120 mm2

10x16x0,811x21x1,0

2(11x21x1,0)

7/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 7

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 8: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

B5 mm8 Nm

A

B5 mm8 Nm

A

B5 mm8 Nm

AB

5 mm8 Nm

A

C

B

A

5 mm8 Nm

C

1

1 2

1 2

K22x21-NZM10

K300-NZM10

K2x120-NZM10

8/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 8

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 9: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

B

A

10 mm50 Nm

B

A

8 mm50 Nm

B

C

A

B

A

B

C

A

1 2

3

1 2

K2x240-NZM10

K2x240IP-NZM10

9/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 9

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 10: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

A

B10 mm

C

AB

OFF

ON

TRIP

70

254

Ø 43

A

B

C

1 2

3 4

A

C

B

1 K2x240W-NZM10

RG-NZM10

10/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 10

For Immediate Delivery call KMParts.com at (866) 595-9616

Page 11: P10(4)- NZM 10(4)-N/B NZM 10(4)-(N)(S)(H) /ZM (M, V) … · Current Limiting Data according to UL 489 Instructions for Field Wiring Terminal Kit System for NZM 10 (C)NA and NZM 10

Current Limiting Data according to UL 489

Instructions for Field WiringTerminal Kit System for NZM 10 (C)NA and NZM 10 N/B-NA

Circuit Breaker Threshold Current

Circuit Breaker Wire Size Max. A-Rating TighteningTorque

Intermediate Current FrequencyHigh Interrupting Capacity

Type

Bolt-onTerminal Cover (3) 2Z1213-651.28 L1; L2; L3 600 A 50 Nm

K2x240W-NZM 10K2x240IP-NZM 10Terminal Cover (3) 2Z123-651.28Insulating Plate (1) 4Z 123-651.1003

Auxiliary Terminal

2xAWG2-2x500MCM

AWG 18-14

50 Nm

1,2 Nm

Cu + Al

Cu only

Cu only

600 A

500 A

350 A

K2x120-NZM 10

Auxiliary Terminal

2xAWG3/0-2x250MCM

AWG 18-14

K300-NZM 10

Auxiliary Terminal

250MCM-500MCM

AWG 18-14

NZM10H 600

Max. FrameSize A

RMSSYMkA

PeakkA

I2dt103A2s

MAXIMUMRMSSYMkA

PeakkA

I2dt103A2s

MAXIMUMRMSSYMkA

60 HzVoltage (V)Peak

kAI2dt103A2s

MAXIMUM

39

39

39

125

65

42

200

100

50

34.0

42.0

40.0

2800

5500

5500

50.0

52.0

45.0

3500

6600

7200

55.0

61.0

48.0

4000

8000

8000

240

480

600

8 Nm

1,2 Nm

8 Nm

1,2 Nm

Moeller GmbH,Industrieautomation, 53105 Bonn' 2002 by Moeller GmbH

11/95 AWA123-1089 10004851/0013 FDPrinted in the Federal Republic of Germany (02/02)

nderungenvorbehalten

11/11

11/9

5 AW

A123

-108

9

123-1089 06.02.2002 15:04 Uhr Seite 11

For Immediate Delivery call KMParts.com at (866) 595-9616