AIR‐summary template Lic No: P0019‐02 Year 2016Answer all questions and complete all tables where relevant
2No
3Basic air monitoring checklist AGN2 Yes
Table A1: Licensed Mass Emissions/Ambient data‐periodic monitoring (non‐continuous)
Emission reference no: Parameter/ Substance
Frequency of Monitoring
ELV in licence or any revision therof Licence Compliance criteria Measured value
Unit of measurement
Compliant with licence limit Method of analysis
Annual mass load (kg)
Comments ‐reason for change in % mass load from previous year if applicable
A1‐1Nitrogen oxides (NOx/NO2) Biannual 200mg/m3
No 30min mean can exceed the ELV
84.99
mg/Nm3 yes EN 14792:2005 1598
Mass load of Nox increased by 53%
A1‐1Nitrogen oxides (NOx/NO2) Biannual 200mg/m3
No 30min mean can exceed the ELV
85.98mg/Nm3 yes EN 14792:2005 as above
A1‐2Nitrogen oxides (NOx/NO2) Biannual 200mg/m3
No 30min mean can exceed the ELV
89.77mg/Nm3 yes EN 14792:2005 as above
A1‐2Nitrogen oxides (NOx/NO2) Biannual 200mg/m3
No 30min mean can exceed the ELV
91.5mg/Nm3 yes EN 14792:2005 as above
A1‐1 volumetric flow Biannual9,200m3/hr; 220,800m3/day 100 % of values < ELV
1671Nm3/hour yes OTH: EN 16911‐1 N/A
A1‐1 volumetric flow Biannual9,200m3/hr; 220,800m3/day 100 % of values < ELV
2582Nm3/hour yes OTH: EN 16911‐1 N/A
A1‐2 volumetric flow Biannual9,200m3/hr; 220,800m3/day 100 % of values < ELV
1835Nm3/hour yes OTH: EN 16911‐1 N/A
A1‐2 volumetric flow Biannual9,200m3/hr; 220,800m3/day 100 % of values < ELV
2176Nm3/hour yes OTH: EN 16911‐1 N/A
Note 1: Volumetric flow shall be included as a reportable parameter
1Does your site have licensed air emissions? If yes please complete table A1 and A2 below for the current
reporting year and answer further questions. If you do not have licenced emissions and do not complete a solvent management plan (table A4 and A5) you do not need to complete the tables
Yes
There are 2 major emission points on site (Emission Point No's: A1‐1 and A1‐2). It is a requirement of the Sites IE
Licence to conduct monitoring on these emission points on a biannual basis. The site also has a number of minor
emission points (e.g. emissions from emergency generators and laboratory fumehoods), there is no requirement in the site IE Licence to conduct monitoring at the minor emission
points.
Periodic/Non‐Continuous Monitoring
Are there any results in breach of licence requirements? If yes please provide brief details in the comment section of TableA1 below
Was all monitoring carried out in accordance with EPA guidance note AG2 and using the basic air monitoring checklist?
In 2016, monitoring of emissions from A1‐1 and A1‐2 was conducted by Exova Catalyst on a biannual basis.
Additional information
2
AIR‐summary template Lic No: P0019‐02 Year 2016
4No
5N/A
6N/A
7N/A
Table A2: Summary of average emissions ‐continuous monitoring
Emission reference no:
Parameter/ Substance
ELV in licence or any revision therof
Averaging Period Compliance Criteria Units of measurement
Annual Emission Annual maximum Monitoring Equipment downtime (hours)
Number of ELV exceedences in current reporting year
Comments
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/ASELECT SELECTSELECT SELECTSELECT SELECTSELECT SELECT
note 1: Volumetric flow shall be included as a reportable parameter.
Table A3: Abatement system bypass reporting table Bypass protocol
Date* Duration** (hours) LocationN/A N/A N/A
Continuous Monitoring
Does your site carry out continuous air emissions monitoring?
If yes please review your continuous monitoring data and report the required fields below in Table A2 and compare it to its relevant Emission Limit Value (ELV)
Did continuous monitoring equipment experience downtime? If yes please record downtime in table A2 below
Do you have a proactive service agreement for each piece of continuous monitoring equipment?
Did your site experience any abatement system bypasses? If yes please detail them in table A3 below
* this should include all dates that an abatement system bypass occurred
** an accurate record of time bypass beginning and end should be logged on site and maintained for future Agency inspections please refer to bypass protocol link
N/AReason for bypass Corrective actionImpact magnitude
N/AN/A
3
AIR‐summary template Lic No: P0019‐02 Year 2016
8 Do you have a total Emission Limit Value of direct and fugitive emissions on site? if yes please fill out tables A4 and A5No
Solvent regulations
Reporting year Total solvent input on site (kg)
Total VOC emissions to Air from entire site
(direct and fugitive)
Total VOC emissions as %of solvent input Total Emission Limit Value
(ELV) in licence or any revision therof
Compliance
N/A N/A N/A N/A N/AN/A
SELECT
(I) Inputs (kg)
Solvent (I) Inputs (kg)
Organic solvent emission in waste
(k )
Solvents lost in water (kg)
Collected waste solvent (kg) Fugitive Organic Solvent (kg)
Solvent released in other ways e.g. b (k )
Solvents destroyed onsite through h l
Total emission of Solvent to air (kg)
N/A N/A N/A N/A N/A N/A N/A N/A N/A
Total N/A
(O) Outputs (kg)
Table A4: Solvent Management Plan Summary Total VOC Emission limit value
Table A5: Solvent Mass Balance summary
Please refer to linked solvent regulations to complete table 5 and 6
Solvent use and management on site
1
AER Monitoring returns summary template‐WATER/WASTEWATER(SEWER) Lic No: P0019‐02 Year 2016
2
Yes
Location reference
Location relative to site
activitiesPRTR Parameter
Licenced Parameter
Monitoring date
ELV or trigger level in licence or any revision
thereof*
Licence Compliance
criteriaMeasured value
Unit of measurement
Compliant with licence
Comments
SW1 onsite N/A COD Jan‐16 N/A All values < ELV 10 mg/L YesSW1 onsite N/A COD Feb‐16 N/A All values < ELV 11.75 mg/L YesSW1 onsite N/A COD Mar‐16 N/A All values < ELV 12.4 mg/L YesSW1 onsite N/A COD Apr‐16 N/A All values < ELV 11 mg/L YesSW1 onsite N/A COD May‐16 N/A All values < ELV 11.5 mg/L YesSW1 onsite N/A COD Jun‐16 N/A All values < ELV 11.6 mg/L YesSW1 onsite N/A COD Jul‐16 N/A All values < ELV 10.75 mg/L YesSW1 onsite N/A COD Aug‐16 N/A All values < ELV 15.25 mg/L YesSW1 onsite N/A COD Sep‐16 N/A All values < ELV 12.6 mg/L YesSW1 onsite N/A COD Oct‐16 N/A All values < ELV 19.5 mg/L YesSW1 onsite N/A COD Nov‐16 N/A All values < ELV 19.8 mg/L YesSW1 onsite N/A COD Dec‐16 N/A All values < ELV 19.5 mg/L Yes
*trigger values may be agreed by the Agency outside of licence conditions
Location Reference
Date of inspection Source of
contamination N/A N/A N/A
SELECT
3No
4
External /Internal Lab Quality checklist
Assessment of results checklist Yes
Table W3: Licensed Emissions to water and /or wastewater (sewer)‐periodic monitoring (non‐continuous)
Emission reference no:
Emission released to
Parameter/ SubstanceNote 1 Type of sample
Frequency of monitoring Averaging period
ELV or trigger values in licence or any revision therofNote 2 Licence Compliance criteria Measured value
Unit of measurement
Compliant with licence Method of analysis
Procedural reference source
Procedural reference standard number
Annual mass load (kg) Comments
SE1Wastewater/Se
werCOD composite Monthly Monthly 270kg/day; 600mg/l
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
27 mg/L yesDigestion +
Spectrophotometry
APHA / AWWA "Standard Methods" Method 5220D
1494Change in mass
emission from 2015 is ‐50%.
SE1Wastewater/Se
werBOD composite Monthly Monthly 135kg/day; 300mg/l
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
8 mg/L yesOther (TCMP Nitrification
Inhibition)
APHA / AWWA "Standard Methods" Method 5210B
484Change in mass
emission from 2015 is ‐67%.
SE1Wastewater/Se
werSuspended Solids composite Monthly Monthly 180kg/day; 400mg/l
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
10 mg/L yes Gravimetric analysisAPHA / AWWA "Standard Methods" Method 2540D
570Change in mass
emission from 2015 is 6%
SE1Wastewater/Se
werSulphate composite Monthly Monthly 225kg/day; 500mg/l
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
37 mg/L yes Ion ChromatographyAPHA / AWWA "Standard Methods" Method 4110B
2058Change in mass
emission from 2015 is 78%
SE1Wastewater/Se
werFats, Oils and Greases composite Monthly Monthly 90kg/day; 200mg/l
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
1 mg/L yes Gravimetric analysisAPHA / AWWA "Standard Methods" Method 5220B
56Change in mass
emission from 2015 is ‐57%
SE1Wastewater/Se
werOrtho‐phosphate (as
PO4)composite Monthly Monthly 22.5kg/day; 50mg/l
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
2 mg/L yes Ion ChromatographyAPHA / AWWA "Standard Methods" Method 4500‐PE
109Change in mass
emission from 2015 is 52%
1
Does your site have licensed emissions direct to surface water or direct to sewer? If yes please complete table W2 and W3 below for the current reporting year and answer further questions. If you do not have licenced emissions you only need to complete
table W1 and or W2 for storm water analysis and visual inspectionsYes
All final effluent is emitted through EPA emission point SE1. All stormwater is emitted through EPA emission point SW1.
Table W2 Visual inspections‐Please only enter details where contamination was observed.
Description of contamination Corrective action Comments
Flow of stormwater
leaving the site is not measured
therefore annual mass load cannot be calculated.
Additional information
Was it a requirement of your licence to carry out visual inspections on any surface water discharges or watercourses on or near your site? If yes please complete table W2 below
summarising only any evidence of contamination noted during visual inspections
A visual assessment of the stormwater discharge is conducted daily. In 2016, there was no evidence of contamination noted during visual
inspection.
Table W1 Storm water monitoring
N/A N/A N/A
Licensed Emissions to water and /or wastewater(sewer)‐periodic monitoring (non‐continuous)Was there any result in breach of licence requirements? If yes please provide brief details in the
comment section of Table W3 below Additional information
Was all monitoring carried out in accordance with EPA guidance and checklists for Quality of Aqueous Monitoring Data Reported to the EPA? If no please detail what areas
require improvement in additional information boxAll final effluent and stormwater analyses are completed by Bord na Mona, Newbridge, Co. Kildare. Toxicity monitoring of the final effluent was conducted by Shannon Aquatic Toxicity Laboratory, Shannon, Co. Clare.
2
AER Monitoring returns summary template‐WATER/WASTEWATER(SEWER) Lic No: P0019‐02 Year 2016
SE1Wastewater/Se
werChlorides (as Cl) composite Monthly Monthly N/A N/A 206 mg/L yes Ion Chromatography
APHA / AWWA "Standard Methods"
Method 4500‐CL‐E
11519
Change in mass emission from 2015 is
59%. Effluent is discharged to Local Authority Sewer ‐ EQS is not available.
SE1Wastewater/Se
werTotal nitrogen composite Monthly Monthly N/A N/A 2 mg/L yes
Digestion + Spectrophotometry
APHA / AWWA "Standard Methods"
ENV 12260:2003
115
Change in mass emission from 2015 is
37%. Effluent is discharged to Local Authority Sewer ‐ EQS is not available.
SE1Wastewater/Se
werTotal phosphorus composite Monthly Monthly N/A N/A 2 mg/L yes
Digestion + Spectrophotometry
APHA / AWWA "Standard Methods"
Method 4500‐PB & Hach Method 8190
118
Change in mass emission from 2015 is
32%. Effluent is discharged to Local Authority Sewer ‐ EQS is not available.
SE1Wastewater/Se
werVolatile organic
compounds (as TOC)composite Quarterly Quarterly N/A N/A 0.5 mg/L yes
GC (Gas Chromatography)
US EPA
USEPA VOC's Method D3695‐95
28
Change in mass emission from 2015 is
39%. Effluent is discharged to Local Authority Sewer ‐ EQS is not available.
SE1Wastewater/Se
werVolatile organic
compounds (as TOC)composite Quarterly Quarterly N/A N/A 0.5 mg/L yes
GC (Gas Chromatography)
US EPA USEPA VOC's Method D3695‐95
N/A N/A
SE1Wastewater/Se
werVolatile organic
compounds (as TOC)composite Quarterly Quarterly N/A N/A 0.5 mg/L yes
GC (Gas Chromatography)
US EPA USEPA VOC's Method D3695‐95
N/A N/A
SE1Wastewater/Se
werVolatile organic
compounds (as TOC)composite Quarterly Quarterly N/A N/A 0.5 mg/L yes
GC (Gas Chromatography)
US EPA USEPA VOC's Method D3695‐95
N/A N/A
SE1Wastewater/Se
wer30min EC50 to Vibrio
fischericomposite Annual Annual 10TU
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
<2.2 NTU yes Toxicity Analysis ISOISO 11348‐3: 2007
N/A N/A
SE1Wastewater/Se
wer48h LC50 to Tisbe
battagliaicomposite Annual Annual 10TU
All results < 1.2 times ELV, plus 8 from ten results must be < ELV
<3.1 NTU yes Toxicity Analysis ISO ISO 14669:1999
N/A N/A
Note 1: Volumetric flow shall be included as a reportable parameterNote 2: Where Emission Limit Values (ELV) do not apply to your licence please compare results against EQS for Surface water or relevant receptor quality standards
3
AER Monitoring returns summary template‐WATER/WASTEWATER(SEWER) Lic No: P0019‐02 Year 2016
5 Yes
6No
7 Yes On‐site Engineering
8 NoTable W4: Summary of average emissions ‐continuous monitoring
Emission reference no:
Emission released to Parameter/ Substance
ELV or trigger values in licence or any revision thereof
Averaging Period
Compliance Criteria
Units of measurement
Annual Emission for current reporting year (kg)
% change +/‐ from previous reporting year
Monitoring Equipment downtime (hours)
Number of ELV exceedences in reporting year
SE1Wastewater/Se
werTemperature 42oC 30 minutes
No temperature value shall
exceed the limit.value
degrees C 18 12% 0 0
SE1Wastewater/Se
werpH 6‐10pH
Flow Proportional
No pH value shall deviate from the.specified range
pH units 7.7 3% 0 0
SE1Wastewater/Se
wervolumetric flow 450m3/day 24 hour
No flow value shall exceed the .specific limit
m3/day 56,153,000 28% 0 0
SW1 Water pH N/A 30 minutes N/A pH units 7.7 3% 0 0
note 1: Volumetric flow shall be included as a reportable parameter.
Table W5: Abatement system bypass reporting tableDate Duration (hours) Location Resultant
emissionsReason for bypass
Corrective action*
Was a report submitted to the EPA?
When was this report submitted?
N/A N/A N/A N/A N/A N/A N/A N/A
*Measures taken or proposed to reduce or limit bypass frequency
Continuous monitoring Additional Information
Does your site carry out continuous emissions to water/sewer monitoring? Emissions from SE1 (final effluent) is continuously monitored for
temperature, pH and flow. Emissions from SW1 (stormwater discharge)is continuously monitored for pH.
If yes please summarise your continuous monitoring data below in Table W4 and compare it to its relevant Emission Limit Value (ELV)
As the parameter is pH, the annual mass emission for the year is reported in pH units rather than kg. The average pH for the year is reported.
As the parameter is pH, the annual mass emission for the year is reported in pH units rather than kg. The average pH for the year is reported.
Did continuous monitoring equipment experience downtime? If yes please record downtime in table W4 belowDo you have a proactive service contract for each piece of continuous monitoring equipment on site?Did abatement system bypass occur during the reporting year? If yes please complete table W5 below
Comments
As the parameter is temperature, the annual mass emission for the year is reported in oC rather than kg. The average temperature for the year is reported.
assume s.g. = 1kg/ltr
1
Bund/Pipeline testing template Lic No: P0019‐02 Year 2016
Bund testing Additional information
1
Yes No bunds failed a water integrity test in 2016.
2 Please provide integrity testing frequency period 3 years
3Yes
4 How many bunds are on site? 275 How many of these bunds have been tested within the required test schedule? 276 How many mobile bunds are on site? 07 Are the mobile bunds included in the bund test schedule? N/A8 How many of these mobile bunds have been tested within the required test schedule? N/A9 410 4
Please list any sump integrity failures in table B111 Yes 12 Yes 13 Is the Fire Water Retention Pond included in your integrity test programme? Yes
Bund/Containment structure ID Type Specify Other type Product containment Actual capacity Capacity required* Type of integrity test Other test type Test date
Integrity reports maintained on site? Results of test
Integrity test failure explanation <50 words Corrective action taken
Scheduled date for retest
Results of retest(if in current reporting year)
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/ASELECT SELECT SELECT SELECT SELECT
* Capacity required should comply with 25% or 110% containment rule as detailed in your licence Commentary
15 bunding and storage guidelines Yes 16 Are channels/transfer systems to remote containment systems tested? N/A17 Are channels/transfer systems compliant in both integrity and available volume? N/A
1 Yes No underground pipework failed an
integrity test in 2016.2 Please provide integrity testing frequency period 3 years*please note integrity testing means water tightness testing for process and foul pipelines (as required under your licence)
Structure ID Type system Material of construction:Does this structure have Secondary containment?
Type of secondary containment
Type integrity testingIntegrity reports maintained on site? Results of test Integrity test failure explanation <50 words Corrective action taken
Scheduled date for retest
Results of retest(if in current reporting year)
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
dropdown menu click to see options
Are you required by your licence to undertake integrity testing on bunds and containment structures ? if yes please fill out table B1 below listing all new bunds and containment structures on site, in addition to all bunds which failed the integrity test‐all bunding structures which failed including mobile bunds must be listed in the table below, please include all bunds outside the licenced testing period (mobile bunds and chemstore included)
Are you required by your licence to undertake integrity testing* on underground structures e.g. pipelines or sumps etc ? if yes please fill out table 2 below listing all underground structures and pipelines on site which failed the integrity test and all which have not been tested withing the integrity test period as specified
Table B2: Summary details of pipeline/underground structures integrity test
How many sumps on site are included in the integrity test schedule?How many of these sumps are integrity tested within the test schedule?
Table B1: Summary details of bund /containment structure integrity test
Please use commentary for additional details not answered by tables/ questions above
Does the site maintain a register of bunds, underground pipelines (including stormwater and foul), Tanks, sumps and containers? (containers refers to "Chemstore" type units and mobile bunds)
Has integrity testing been carried out in accordance with licence requirements and are all structures tested in line with BS8007/EPA Guidance?
Do all sumps and chambers have high level liquid alarms?If yes to Q11 are these failsafe systems included in a maintenance and testing programme?
Pipeline/underground structure testing
1
Groundwater/Soil monitoring template Lic No: P0019‐02 Year 2016
Comments
1yes
2 no
3 no
4Groundwater monitoring template yes
5yes Historic
6
7 on‐going8 yes9 yes
10 yes
11yes
12 no
Table 1: Upgradient Groundwater monitoring results
Date of sampling
Sample location reference
Parameter/ Substance Methodology
Monitoring frequency
Maximum Concentration++
Average Concentration+ unit GTV's* IGV
Upward trend in pollutant concentration over last 5 years of monitoring data
June & Nov 2016 BH305 pH pH electrode Biannually
8.1 8.1 pH units N/A >6.5 & <9.5 no
CODStandard Method Biannually
21 16 mg/l N/A N/A no
NitrateStandard Method Biannually
5 5 mg/l 37.5 25 no
Total Ammonia
Standard Method Biannually
0.4 0.4 mg/l N/A(0.15 (as amminium)
no
Total Nitrogen
Standard Method Biannually
24.4 18.25 mg/l N/A N/A no
ConductivityStandard Method Biannually
1270 1241 uS/cm>800 & <1875
1000 no
ChlorideStandard Method Biannually
21 16 mg/l 187.5 30 no
Trichloroethylene GC‐MS Biannually
3 3 ug/l 7.5 70 no
.+ where average indicates arithmetic mean
.++ maximum concentration indicates the maximum measured concentration from all monitoring results produced during the reporting year
yes
Long term remediation strategy has been agreed
with the EPA and is being implemented with close oversight by the
Agency.Please specify the proposed time frame for the remediation strategyIs there a licence condition to carry out/update ELRA for the site?
Is there evidence that contamination is migrating offsite?
Is the contamination related to operations at the facility (either current and/or historic)
Have potential receptors been identified on and off site?
Has a Conceptual Site Model been developed for the site?
Please provide an interpretation of groundwater monitoring data in the interpretation box below or if you require additional space please include a groundwater/contaminated land monitoring results
interpretaion as an additional section in this AER
In accordance with Schedule C.7 of the sites IE Licence, groundwater monitoring was conducted on five groundwater monitoring wells at the site (BH201, BH205, BH209, BH305 and BH307) in June and November 2016. As limits have not being set for parameters in the sites IE Licence, the results were compared to the EPA Interim Guideline Values (IGV's). From the monitoring carried out in June 2016, electrical conductivity levels were above the IGV at all locations. Ammoniacal nitrogen concentrations were recorded above the IGV in two wells (BH201 and BH305). Chloride concentration was recorded above the Groundwater Treshold Value (GTV) at BH205 and BH209. Trichloroethylene was above the GTV in BH205 and BH209 where vinyl chloride exceeded the GTV in BH201. All other parameters measured in June 2016 were within the IGV for groundwater.From the monitoring conducted in November 2016, electrical conductivity levels were above the IGV at locations BH209, BH305 and BH307. Ammoniacal nitrogen were recorded above the IGV in BH205, BH209 and BH305. Chloride concentrations were recorded above the GTV at BH205 and BH209 which is consistent with June 2016 monitoring. Concentrations of trichloroethylene were above the GTV's at boreholes BH209 and BH201 where vinyl chloride exceeded the GTV in BH205. All other parameters measured were within the IGV for groundwater. (Note BH201 was dry at the time of sampling.)
Are you required to carry out groundwater monitoring as part of your licence requirements?Are you required to carry out soil monitoring as part of your licence requirements?
Have actions been taken to address contamination issues?If yes please summarise remediation strategies proposed/undertaken for the site
Do monitoring results show that groundwater generic assessment criteria such as GTVs or IGVs are exceeded or is there an upward trend in results for a substance? If yes, please
Do you extract groundwater for use on site? If yes please specify use in comment section
Has any type of risk assesment been carried out for the site?
2
Groundwater/Soil monitoring template Lic No: P0019‐02 Year 2016
Table 2: Downgradient Groundwater monitoring results
Date of sampling
Sample location reference
Parameter/ Substance Methodology
Monitoring frequency
Maximum Concentration
Average Concentration unit GTV's* IGV
Upward trend in yearly average pollutant concentration over last 5 years of monitoring data
June & Nov 2016 BH205 pH pH electrode Biannually
7.4 7.2 pH units N/A >6.5 & <9.5 no
CODStandard Method Biannually
22 19 mg/l N/A N/A no
NitrateStandard Method Biannually
6 4 mg/l 37.5 25 no
Total Ammonia
Standard Method Biannually
0.2 0.2 mg/l N/A(0.15 (as amminium)
no
Total Nitrogen
Standard Method Biannually
14 11.6 mg/l N/A N/A no
ConductivityStandard Method Biannually
1053 1022 uS/cm>800 & <1875
1000 no
ChlorideStandard Method Biannually
361 288 mg/l 187.5 30 no
Trichloroethylene GC‐MS Biannually 32 31 ug/l 7.5 70 no
Surface water EQS
Groundwater regulations
GTV's
Drinking water (private supply) standards
Drinking water (public supply) standards
Interim Guideline Values (IGV)
Groundwater monitoring template
*please note exceedance of generic assessment criteria (GAC) such as a Groundwater Threshold Value (GTV) or an Interim Guideline Value (IGV) or an upward trend in results for a substance indicates that further interpretation of monitoring results is required. In addition to completing the above table,
please complete the Groundwater Monitoring Guideline Template Report at the link provided and submit separately through ALDER as a licensee return or as otherwise instructed by the EPA.
**Depending on location of the site and proximity to other sensitive receptors alternative Receptor based Water Quality standards should be used in addition to the GTV e.g. if the site is close to surface water compare to Surface Water Environmental Quality Standards (SWEQS), If the site is close to a
drinking water supply compare results to the Drinking Water Standards (DWS)
More information on the use of soil and groundwater standards/ generic assessment criteria (GAC) and risk assessment tools is available in the EPA published guidance (see the link in G31)
Guidance on the Management of Contaminated Land and Groundwater at EPA Licensed Sites (EPA 2013).
3
Groundwater/Soil monitoring template Lic No: P0019‐02 Year 2016
Table 3: Soil results
Date of sampling
Sample location reference
Parameter/ Substance Methodology
Monitoring frequency
Maximum Concentration
Average Concentration unit
N/A N/A N/A N/A N/A N/A N/A N/ASELECT
Where additional detail is required please enter it here in 200 words or less
1
Environmental Liabilities template Lic No: P0019‐02 Year 2016
Commentary
1
Submitted and agreed by EPA
2 Review required and completed
Updated ELRA submitted to the Agency in July 2015. Awaiting approval of report.
3 € 480,000
4 Submitted and agreed by EPA
5 € 480,000
6 Other please specifyParent company guarantee ‐ Amgen Inc.
7 Enter expiry date N/A8 Closure plan submitted and agreed by EPA
9 Review required and completed
Update submitted to the Agency in July 2015. Awaiting approval of report.
10 Submitted and agreed by EPA11 € 645,000.00
12 Other please specifyParent company guarantee ‐ Amgen Inc.
13 Enter expiry date N/A
Click here to access EPA guidance on Environmental Liabilities and Financial provision
Financial provision for ELRA expiry dateClosure plan initial agreement status
Closure plan review statusFinancial Provision for Closure status
Financial Provision for Closure ‐ amount of cover
Financial provision for Closure expiry dateFinancial Provision for Closure ‐ type
ELRA initial agreement status
ELRA review status
Amount of Financial Provision cover required as determined by the latest ELRA
Financial Provision for ELRA status
Financial Provision for ELRA ‐ amount of cover
Financial Provision for ELRA ‐ type
1
Environmental Management Programme/Continuous Improvement Programme template Lic No: P0019‐02 Year 2016Additional Information
1
Yes
2 Yes
3 Yes
4 Yes
Environmental Management Programme (EMP) reportObjective Category Target Status (% completed) How target was progressed Responsibility Intermediate outcomes
Energy Efficiency/Utility conservation
Optimise the HVAC systems in one Grade C area (GMP area) 10% complete
Following a risk assessment of the air handling units (AHU's), one area (Quality Control Inspection area) was identified to have potential energy efficieny gains. The Project is dependant on Site Quality approval. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservation
Destratification in the Warehouse HVAC Load (New 2017) 10% complete
Installation of energy efficient fans, which in turn will allow larger supply fans to be shut down. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservationWater Recovery PM2 HVAC West Side (New 2017) 50% complete
Condensate from the dehumidifer coil to be rerouted to a recovery tank to supply the cooling water system. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservation Boiler combustion control 80% complete
Run the two boilers with active O2 trim control on the lead designated boiler and operate to achieve the lowest attainable excess oxygen level that will provide effective stable combustion at the required duties. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservation
Lighting controls PM2 & PM3 interstitials (New 2017) 50% complete
Unoccupied set back of lighting in low occupancy areas. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservationSolar powered car charging (New 2017) 10% complete
Investigate potential for charging electric cars from solar panels mounted on the cooling towers. Section Head
Improved Environmental Management Practices
The structure of the management system can be described as comprising of six key elements aimed at continuous
improvement strategy. 1) Organisational & Personnel ‐ roles and responsibilities, training awareness & procedures; 2) Identify
Hazard ‐ identification of hazards and implementation of proper controls; 3) Operational Controls ‐ documented procedures and work instructions; 4) Planning for Emergencies ‐ documented Emergency Response Procedure; 5) Monitoring Performance ‐ evaluated performance of the site against EHS goals; 6) Audit &
Review
Do you maintain an environmental documentation/communication system to inform the public on environmental performance of the facility, as required by the licence
Highlighted cells contain dropdown menu click to view
Does the EMS reference the most significant environmental aspects and associated impacts on‐site
Does the EMS maintain an Environmental Management Programme (EMP) as required in accordance with the licence requirements
Do you maintain an Environmental Mangement System (EMS) for the site. If yes, please detail in additional information
2
Environmental Management Programme/Continuous Improvement Programme template Lic No: P0019‐02 Year 2016
Energy Efficiency/Utility conservation Chilled water optimisation 50% complete
Obtain 10% reduction in demand side for chilled water by: reduce the system pressure; rebalance one index branch; potentially coil changes; PICV valve installations & load transfers to glycol. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservation Lighting Setback 100% complete
Installed Zelio control in the cold chain warehouse undercroft so that during unoccupied periods the lighting will be minimised to emergency lighting. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservation
Recover water from Reverse Osmosis (RO) reject streams to the cooling towers 100% complete
Conduct modifications to the RO system on the purified water skids in PM2, so that the reject is sent to the cooling towers. Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservation Rainwater Harvesting 10% complete
Investigate feasibility to use existing site infrastructure to capture rainwater which can be reused as site service water. Section Head
Improved Environmental Management Practices
Additional improvements
Facilitate priority suppliers to the site to obtain an Environmental Certification (EcoCert) 100% complete
Site facilitated 5 priority suppliers to obtain environmental certification. Site is engaging with other suppliers to implement practices / procedures which would reduce emissions, waste and energy consumption at their facility and improve their overall Environmental Management Practices Section Head
Improved Environmental Management Practices
Energy Efficiency/Utility conservationPromote Greener Transportation 100% complete
Promoted the use of electric cars on site by installing a four charge points in the site carpark and facilitated an electric vehicle car show to increase awareness on site. Section Head
Improved Environmental Management Practices
Additional improvementsSustainability Awareness Promotion 100% complete
Increased environmental awareness of colleagues on site through a Sustainability Awareness Promotion week. Section Head
Improved Environmental Management Practices
Waste reduction/Raw material usage efficiency
Increase recycling and recovery on site 50% complete
Conduct a review of all waste streams generated on site and identify and implement suitable opportunities to reduce the total volume of waste generated on site and where that is not possible, to divert waste to appropriate and compliant recovery or recycling options. Section Head
Improved Environmental Management Practices
1
Lic No: P0019‐02 Year 2016
1 Yes
2Noise Guidance note NG4
Yes
3 No4 N/A
5 No
Date of monitoring Time period
Noise location (on site)
Noise sensitive
location ‐NSL (if applicable) LAeq LA90 LA10 LAmax
Tonal or Impulsive noise* (Y/N)
If tonal /impulsive noise was identified was 5dB penalty applied?
Comments (ex. main noise sources on site, & extraneous noise ex. road traffic)
Is site compliant with noise limits
(day/evening/night)?
11th July 2016 Daytime B1 Yes 56 50 56 81
No N/A
Traffic off and on site. Trees rustling. Children playing. Plant barely audible in traffic lulls.
Yes
11th July 2016 Daytime B2 Yes 50 49 51 65
No N/ATraffic . Trees rustling. Low level steady plant nise audible in traffic lulls.
Yes
11th July 2016 Daytime B3 Yes 48 44 50 65No N/A
Traffic. Low level steady plant noise, barely audible.
Yes
11th July 2016 Daytime B4 Yes 49 45 51 72
No N/ATraffic. Intermittent noise adjoining garden centre. Plant noise audible in traffic lulls.
Yes
11th July 2016 Daytime B5 Yes 48 44 50 67
No N/ATraffic. Intermittent construction activities in carpark. Amgen plant not audible.
Yes
11th July 2016 Daytime B6 Yes 56 50 59 68
No N/A
Traffic. Trees rustling. Intermittent noiose offsite, eg. Lawnmower and strimmer Amgen plant not audible.
Yes
11th July 2016 Daytime B7 Yes 60 50 64 78
No N/A
Traffic. Trees rustling. Intermittent noiose offsite, eg. Lawnmower and strimmer Amgen plant not audible.
Yes
11th July 2016 Daytime B8 Yes 59 52 63 75
No N/A
Traffic. Trees rustling. Intermittent noiose offsite, eg. Lawnmower and strimmer Amgen plant not audible.
Yes
11th July 2016 Evening B1 Yes 50 48 51 58No N/A
Traffic. Trees. Low level steady low level plant noise.
Yes
Noise monitoring summary report
Have there been changes relevant to site noise emissions (e.g. plant or operational changes) since the last noise survey?
Table N1: Noise monitoring summary
Was noise monitoring a licence requirement for the AER period?If yes please fill in table N1 noise summary below
Was noise monitoring carried out using the EPA Guidance note, including completion of the "Checklist for noise measurement report" included in the guidance note as table 6?Does your site have a noise reduction plan When was the noise reduction plan last updated?
2
11th July 2016 Evening B2 Yes 44 42 46 59No N/A
Traffic. Trees. Low level steady low level plant noise.
Yes
11th July 2016 Evening B3 Yes 46 44 48 71
No N/ALocal & distant traffic. Trees rustling. Birds. Plant barely audible in traffic lulls.
Yes
11th July 2016 Evening B4 Yes 47 45 48 59
No N/ALocal & distant traffic. Trees rustling. Birds. Plant noise audible in traffic lulls.
Yes
11th July 2016 Evening B5 Yes 44 41 45 66
No N/ALocal & distant traffic. Trees rustling. Birds. Plant not audible in traffic lulls.
Yes
11th July 2016 Evening B6 Yes 58 48 61 71
No N/ALocal & distant traffic. Trees rustling. Birds. Plant not audible in traffic lulls.
Yes
11th July 2016 Evening B7 Yes 58 48 63 69
No N/ALocal & distant traffic. Trees rustling. Birds. Plant not audible in traffic lulls.
Yes
11th July 2016 Evening B8 Yes 62 50 64 70
No N/ALocal & distant traffic. Trees rustling. Birds. Strimmer off site. Plant not audible.
Yes
11th / 12th July 2016 Night ‐ time B1 Yes 47 44 49 63
No N/ATraffic. Low level steady low level plant noise
Yes
11th / 12th July 2016 Night ‐ time B2 Yes 41 38 43 54
No N/A Traffic. Low level steady level plant noise
Yes
11th / 12th July 2016 Night ‐ time B3 Yes 38 35 40 50
No N/ATraffic. Low level steady low level plant noise
Yes
11th / 12th July 2016 Night ‐ time B4 Yes 39 37 41 62
No N/A Traffic. Low level steady level plant noise
Yes
11th / 12th July 2016 Night ‐ time B5 Yes 42 38 44 62
No N/ATraffic. Plant not audible. Yes
11th / 12th July 2016 Night ‐ time B6 Yes 47 41 50 65
No N/ATraffic. Noise adjoining sites. Plant not audible.
Yes
11th / 12th July 2016 Night ‐ time B7 Yes 50 41 49 73
No N/ATraffic, plant barely audible. Yes
11th / 12th July 2016 Night ‐ time B8 Yes 48 42 46 65
No N/ATraffic, plant not audible. Yes
*Please ensure that a tonal analysis has been carried out as per guidance note NG4. These records must be maintained onsite for future inspection
N/AIf noise limits exceeded as a result of noise attributed to site activities, please choose the corrective action from the following options?
** please explain the reason for not taking action/resolution of noise issues?
Any additional comments? (less than 200 words)
1
Resource Usage/Energy efficiency summary Lic No: P0019‐02 Year 2016
Additional information
1 Enter date of audit03/03/16 (ISO50001 Surveillance Audit)
2
SEAI ‐ Large Industry Energy Network (LIEN) No
3 N/A
Diesel is only a back up to gas for the
boilers and has not had to be used in the boilers for >10 years. There is no licence
ELV for sulphur in the sites IE Licence.
Energy Use Previous year Current year
Production +/‐ % compared to previous reporting year**
Energy Consumption +/‐ % vs overall site production*
Total Energy Used (MWHrs) 41,064.45 42,241.52 N/A N/ATotal Energy Generated (MWHrs) 0 0 N/A N/ATotal Renewable Energy Generated (M 0 0 N/A N/AElectricity Consumption (MWHrs) 23,754.57 25,022.08 N/A N/AFossil Fuels Consumption: N/A N/A
Heavy Fuel Oil (m3) 0 0 N/A N/ALight Fuel Oil (m3) 0 0 N/A N/ANatural gas (m3) 1681146 1514462 N/A N/A
Coal/Solid fuel (metric tonnes) 0 0 N/A N/APeat (metric tonnes) 0 0 N/A N/ARenewable Biomass 0 0 N/A N/A
Renewable energy generated on site 0 0 N/A N/A* where consumption of energy can be compared to overall site production please enter this information as percentage increase or decrease compared to the previous reporting year.** where site production information is available please enter percentage increase or decrease compared to previous year
Water Emissions Water Consumption
Water useWater extracted Previous year m3/yr.
Water extracted Current year m3/yr.
Production +/‐ % compared to previous reporting year**
Energy Consumption +/‐ % vs overall site production*
Volume Discharged back to environment(m3yr):
Volume used i.e not discharged to environment e.g. released as steam m3/yr Unaccounted for Water:
Groundwater 0 0 N/A N/A 0 0 0Surface water 0 0 N/A N/A 0 0 0Public supply 77028 94687 N/A N/A 64845 24475 5367Recycled water 0 0 N/A N/A 0 0 0Total 77028 94687 N/A N/A 64845 24475 5367* where consumption of water can be compared to overall site production please enter this information as percentage increase or decrease compared to the previous reporting year.** where site production information is available please enter percentage increase or decrease compared to previous year
Table R2 Water usage on site
When did the site carry out the most recent energy efficiency audit? Please list the recommendations in table 3 below
Is the site a member of any accredited programmes for reducing energy usage/water conservation such as the SEAI programme linked to the right? If yes please list them in additional information
Where Fuel Oil is used in boilers on site is the sulphur content compliant with licence conditions? Please state percentage in additional information
Table R1 Energy usage on site
2
Resource Usage/Energy efficiency summary Lic No: P0019‐02 Year 2016
Total Landfill Incineration Recycled OtherHazardous (Tonnes) 223.175 0 169.682 33.613 19.88Non‐Hazardous (Tonnes) 982.497 0 219.993 762.504 0
Table R3 Waste Stream Summary
3
Resource Usage/Energy efficiency summary Lic No: P0019‐02 Year 2016
Date of audit RecommendationsDescription of Measures proposed Origin of measures
Predicted energy savings % Implementation date Responsibility Completion date
Status and comments
03/03/2016ISO 50,001 Surveillance Audit N/A
accredited programme N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/AN/A N/A N/A N/A N/A N/A N/A N/A N/A
Table R5: Power Generation: Where power is generated onsite (e.g. power generation facilities/food and drink industry)please complete the following informationUnit ID Unit ID Unit ID Unit ID Station Total
Technology N/APrimary Fuel N/AThermal Efficiency N/AUnit Date of Commission N/ATotal Starts for year N/ATotal Running Time N/ATotal Electricity Generated (GWH) N/AHouse Load (GWH) N/AKWH per Litre of Process Water N/AKWH per Litre of Total Water used onN/A
Table R4: Energy Audit finding recommendations
1
Complaints and Incidents summary template Lic No: P0019‐02 Year 2016
Additional information
Yes
Date Category Other type (please specify)
Brief description of complaint (Free txt <20 words)
Corrective action< 20 words Resolution status Resolution date Further information
23/05/2016 Noise N/A
Local resident observed noise from a project related activity when items were placed into a skip.
Project skip was relocated to an alternative location on site. Complete 23/05/2016
The complainant was contacted immediately to discuss the details of the reported complaint and to apologise for the inconvenience.
21/09/2016 Noise N/A
Local resident observed noise from a project related activity being conducted close to the site boundary.
Work was stopped immediately. Complete 22/09/2016
The complainant was contacted where an explaination of the project works was provided and it was explained that the works would be completed within 1‐2 days. An apology was provided for any inconvenience.
22/09/2016 Noise N/A
Local resident observed noise from a project related activity being conducted close to the site boundary.
Project working hours were reduced to between 9am and 4.30pm. Complete 22/09/2016
The complainant was contacted where an explaination of the project works was provided and it was explained that the works would be completed within 1‐2 days. An apology was provided for any inconvenience and the mobile number for site contact was provided to the complainant if there were any further issues noted.
SELECT SELECTSELECT SELECT
Total complaints open at start of reporting year 0Total new complaints received during reporting year 1Total complaints closed during reporting year 1Balance of complaints end of reporting year 0
Additional information
No
What is an incident
Table 2 Incidents summary
Date of occurrence Incident nature Location of occurrence
Incident category*please refer to guidance Receptor Cause of incident
Other cause(please specify)
Activity in progress at time of incident Communication Occurrence
Corrective action<20 words
Preventative action <20 words Resolution status
Resolution date
Likelihood of reoccurence
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/ASELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECTSELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECTSELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECTSELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT SELECT
Total number of incidents current year 0Total number of incidents previous year 0% reduction/ increase 0
Complaints
Have you received any environmental complaints in the current reporting year? If yes please complete summary details of complaints received on site in table 1 below
Table 1 Complaints summary
Incidents
Have any incidents occurred on site in the current reporting year? Please list all incidents for current reporting year in Table 2 below
*For information on how to report and what constitutes an incident
1
WASTE SUMMARY Lic No: P0019‐02 Year 2016
PRTR facility logon
Additional Information
1 No
2 No
3 No
Table 1 Details of waste accepted onto your site for recovery, disposal or treatment (do not include wastes generated at your site, as these will have been reported in your PRTR workbook)EWC code Description of waste
accepted Please enter an accurate and detailed description ‐ which applies to relevant EWC code
Quantity of waste accepted in current reporting year (tonnes)
Reason for reduction/ increase
from previous reporting year
Packaging Content (%)‐ only applies if the
waste has a packaging component
European Waste Catalogue EWC codes European Waste Catalogue EWC codes
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
4 N/A
5 N/A
6 N/A7 Do you have an odour management system in place for your facility? If no why? N/A8 Do you maintain a sludge register on site? N/A
Table 2 Waste type and tonnage‐landfill only
Waste types permitted for disposal
Authorised/licenced annual intake for disposal (tpa)
Actual intake for disposal in reporting year (tpa)
Remaining licensed capacity at end of
reporting year (m3) CommentsN/A N/A N/A N/A
Table 3 General information‐Landfill only
Total disposal area occupied by waste
Lined disposal area occupied by waste
Unlined area
SELECT UNIT SELECT UNIT SELECT UNIT
Cell 8
Inert or non-hazardous Predicted date to cease landfilling
Licence permits asbestos
Is there a separate cell for asbestos?
Accepted asbestos in reporting year
Comments on liner type
SECTION D‐TO BE COMPLETED BY LANDFILL SITES ONLY
N/A
Area ID Date landfilling commenced Date landfilling ceased Currently landfilling Private or Public Operated
Is all waste storage infrastructure as required by your licence and approved by the Agency in place? If no please list waste storage infrastructure required on site
Does your facility have relevant nuisance controls in place?
Disposal/Recovery or treatment operation carried out at your site and the
description of this operation
Quantity of waste
remaining on site at the end of reporting year (tonnes)
Comments ‐
SECTION C‐TO BE COMPLETED BY ALL WASTE FACILITIES (waste transfer stations, Composters, Material recovery facilities etc) EXCEPT LANDFILL SITES
Is all waste processing infrastructure as required by your licence and approved by the Agency in place? If no please list waste processing infrastructure required onsite
Did your site have any rejected consignments of waste in the current reporting year? If yes please give a brief explanation in the additional information
Was waste accepted onto your site that was generated outside the Republic of Ireland? If yes please state the quantity in tonnes in additional information
Licenced annual tonnage limit for your
site (total tonnes/annum)
Source of waste accepted Quantity of waste accepted in previous reporting year (tonnes)
Reduction/ Increase over
previous year +/ ‐ %
SECTION A‐PRTR ON SITE WASTE TREATMENT AND WASTE TRANSFERS TAB‐ TO BE COMPLETED BY ALL IPPC AND WASTE FACILITIES dropdown list click to see options
SECTION B‐ WASTE ACCEPTED ONTO SITE‐TO BE COMPLETED BY ALL IPPC AND WASTE FACILITIES
Were any wastes accepted onto your site for recovery or disposal or treatment prior to recovery or disposal within the boundaries of your facility ?; (waste generated within your boundaries is to be captured through PRTR reporting)
If yes please enter details in table 1 below
2
WASTE SUMMARY Lic No: P0019‐02 Year 2016
Table 4 Environmental monitoring‐landfill only Landfill Manual‐Monitoring StandardsWas meterological monitoring in compliance with Landfill Directive (LD) standard in reporting year +
Was leachate monitored in compliance with LD standard in reporting year
Was Landfill Gas monitored in compliance with LD standard in reporting year
Was SW monitored in compliance with LD standard in reporting year
Have GW trigger levels been established
Were emission limit values agreed with the Agency (ELVs)
Was topography of the site surveyed in reporting year
Has the statement under S53(A)(5) of WMA been submitted in reporting year Comments
.+ please refer to Landfill Manual linked above for relevant Landfill Directive monitoring standardsTable 5 Capping‐Landfill only
Area uncapped* Area with temporary cap
SELECT UNIT SELECT UNIT
*please note this includes daily cover areaTable 6 Leachate‐Landfill only
9 Is leachate from your site treated in a Waste Water Treatment Plant? SELECT10 Is leachate released to surface water? If yes please complete leachate mass load information below SELECT
Volume of leachate in reporting year(m3) Leachate (BOD) mass load (kg/annum)
Leachate (COD) mass load (kg/annum)
Leachate (NH4) mass load (kg/annum)
Leachate (Chloride) mass load kg/annum Leachate treatment on-site
Specify type of leachate treatment Comments
Table 7 Landfill Gas‐Landfill only
Gas Captured&Treated by
LFG System m3 Power generated (MW / KWh) Used on-site or to national grid
Was surface emissions monitoring performed during the reporting
year? CommentsSELECT
Area with final cap to LD Standard m2 ha, a Area capped other
Area with waste that should be permanently capped to date under
licence What materials are used in the cap Comments
Please ensure that all information reported in the landfill gas section is consistent with the Landfill Gas Survey submitted in conjunction with PRTR returns
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | 6167 23/03/2017 14:09
Guidance to completing the PRTR workbook
Version 1.1.19REFERENCE YEAR 2016
1. FACILITY IDENTIFICATIONParent Company NameAmgen Technology (Ireland) Unlimited Compan
Facility Name Amgen Technology (Ireland) Unlimited CompanPRTR Identification Number P0019
Licence Number P0019-02
Classes of ActivityNo. class_name
- Refer to PRTR class activities below
Address 1 Pottery RoadAddress 2 Dun LaoghaireAddress 3Address 4
DublinCountry Ireland
Coordinates of Location-6.14958 53.2718River Basin District IEEA
NACE Code 2120Main Economic ActivityManufacture of pharmaceutical preparation
AER Returns Contact Name Helena MulvihillAER Returns Contact Email Address [email protected]
AER Returns Contact Position EHS ManagerAER Returns Contact Telephone Number 00353 1 2049123
AER Returns Contact Mobile Phone NumberAER Returns Contact Fax Number
Production Volume 0.0Production Volume Units
Number of Installations 0Number of Operating Hours in Year 0
Number of Employees 455User Feedback/Comments The site was 100% compliant with all the conditions of the sites IE Licence in 2016. The manufacturing profile for the site varied in 2016, where two new products were introduced throughout the year and the final commissioning phase was completed on equipment in the packaging hall. There was a decrease in the volume
of HFC's released to atmosphere, these releases were insignificant and were due to random unforeseen failures such as vibration. The volume of non hazardous waste and hazardous waste sent for recovery increased in 2016, this is mainly due to the site upgrade works which are on-going on site.
Web Address
2. PRTR CLASS ACTIVITIESActivity Number Activity Name4(e) Installations using a chemical or biological process for the production on an industrial scale of basic pharmaceutical produ
3. SOLVENTS REGULATIONS (S.I. No. 543 of 2002)Is it applicable? No
Have you been granted an exemption ?NoIf applicable which activity class applies (as pe
Schedule 2 of the regulations) ?Is the reduction scheme compliance route being
used ?
4. WASTE IMPORTED/ACCEPTED ONTO SITE Guidance on waste imported/accepted onto siteDo you import/accept waste onto your site for on-
site treatment (either recovery or disposal activities? No
This question is only applicable if you are an IPPC or Quarry site
PRTR Returns Workbook
Sheet : Releases to Air AER Returns Workbook 23/3/2017 14:12
4.1 RELEASES TO AIR Link to previous years emissions data | PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | 23/03/2017 14:128 10 18 18 26 26 6 7 6 6
SECTION A : SECTOR SPECIFIC PRTR POLLUTANTSPlease enter all quantities in this section in KGs
QUANTITY
EPA Emission Point A1-1 EPA Emission Point A1-2
No. Annex II Name M/C/E Method Code Designation or Description Emission Point 1 Emission Point 2 T (Total) KG/YearA (Accidental) KG/Year
F (Fugitive) KG/Year
08 Nitrogen oxides (NOx/NO2) M EN 14792:2005 799.35 798.97 1598.32 0.0 0.004 Hydro-fluorocarbons (HFCs) M OTH Weighed 0.0 0.0 66.3 0.0 66.303 Carbon dioxide (CO2) C OTH ETS Calculation 1587000.0 1587000.0 3174000.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
SECTION B : REMAINING PRTR POLLUTANTSPlease enter all quantities in this section in KGs
QUANTITY
No. Annex II Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year F (Fugitive) KG/Year0.0 0.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
SECTION C : REMAINING POLLUTANT EMISSIONS (As required in your Licence)Please enter all quantities in this section in KGs
QUANTITY
Pollutant No. Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year F (Fugitive) KG/Year0.0 0.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
Additional Data Requested from Landfill operators
Landfill: Amgen Technology (Ireland) Unlimited CompanyPlease enter summary data on the quantities of methane flared and / or utilised
additional_pollutant_no T (Total) kg/Year M/C/E Method CodeDesignation or
DescriptionFacility Total Capacity m3
per hourTotal estimated methane generation (as per
site model) 0.0 N/AMethane flared 0.0 0.0 (Total Flaring Capacity)
Methane utilised in engine/s 0.0 0.0 (Total Utilising Capacity)Net methane emission (as reported in Section
A above) 0.0 N/A
RELEASES TO AIRMETHOD
POLLUTANT METHODMethod Used
For the purposes of the National Inventory on Greenhouse Gases, landfill operators are requested to provide summary data on landfill gas (Methane) flared or utilised on their facilities to accompany the figures for total methane generated. Operators should only report their Net methane (CH4) emission to the environment under T(total) KG/yr for Section A: Sector specific PRTR pollutants above. Please complete the table below:
Method Used
Method Used
RELEASES TO AIRPOLLUTANT METHOD
Method Used
POLLUTANT
RELEASES TO AIR
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 1 of 1
Sheet : Releases to Waters AER Returns Workbook 23/3/2017 14:13
4.2 RELEASES TO WATERS Link to previous years emissions data | PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | 23/03/2017 14:138 8 16 16 24 24 6 6 6
SECTION A : SECTOR SPECIFIC PRTR POLLUTANTS Data on ambient monitoring of storm/surface water or groundwater, conducted as part of your licence requirements, should NOT be submitted under AER / PRTR Reporting as thPlease enter all quantities in this section in KGs
QUANTITY
No. Annex II Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year F (Fugitive) KG/Year0.0 0.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
SECTION B : REMAINING PRTR POLLUTANTSPlease enter all quantities in this section in KGs
QUANTITY
No. Annex II Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year F (Fugitive) KG/Year0.0 0.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
SECTION C : REMAINING POLLUTANT EMISSIONS (as required in your Licence)Please enter all quantities in this section in KGs
QUANTITY
Pollutant No. Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year F (Fugitive) KG/Year0.0 0.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
RELEASES TO WATERS
Method Used
RELEASES TO WATERS
RELEASES TO WATERS
Method Used
POLLUTANTMethod Used
POLLUTANT
POLLUTANT
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 1 of 1
Sheet : Releases to Wastewater or Sewer AER Returns Workbook 23/3/2017 14:13
4.3 RELEASES TO WASTEWATER OR SEWER Link to previous years emissions data | PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P001 23/03/2017 14:138 10 18 24 6 6 6 6
SECTION A : PRTR POLLUTANTSPlease enter all quantities in this section in KGs
QUANTITYEPA Emission Point No.
SE1No. Annex II Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year F (Fugitive) KG/Year
79 Chlorides (as Cl) M CRMAPHA 2012, 22nd Edition Method 4500-CL-E 11519.0 11519.0 0.0 0.0
12 Total nitrogen M EN 12260:2003 115.0 115.0 0.0 0.0
13 Total phosphorus M CRM
APHA 2012, 22nd Edition, Method 4500-PB & Hach Method 8190 118.0 118.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
SECTION B : REMAINING POLLUTANT EMISSIONS (as required in your Licence)Please enter all quantities in this section in KGs
QUANTITYEPA Emission Point No.
SE1Pollutant No. Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year F (Fugitive) KG/Year
303 BOD M CRM
APHA 2012, 22nd Edition, Method 5210B. TCMP Nitrification inhibition. 484.0 484.0 0.0 0.0
306 COD M CRMAPHA 2012, 22nd Edition, Method 5220D 1494.0 1494.0 0.0 0.0
314 Fats, Oils and Greases M CRMAPHA 2012, 22nd Edition, Method 5520B 56.0 56.0 0.0 0.0
240 Suspended Solids M CRMAPHA 2012, 22nd Edition, Method 2540D 570.0 570.0 0.0 0.0
343 Sulphate M CRMAPHA 2012, 22nd Edition, Method 4110B 2058.0 2058.0 0.0 0.0
332 Ortho-phosphate (as PO4) M CRM
APHA 2012, 22nd Edition, 4500-PE. Ascorbic Acid / HACH Method 109.0 109.0 0.0 0.0
330 Organic solvents M CRM USEPA 524.2 28.08 28.08 0.0 0.0* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
OFFSITE TRANSFER OF POLLUTANTS DESTINED FOR WASTE-WATER TREATMENT OR SEWER
OFFSITE TRANSFER OF POLLUTANTS DESTINED FOR WASTE-WATER TREATMENT OR SEWER
Method Used
Method Used
POLLUTANT METHOD
POLLUTANT METHOD
Link to previous years emissions data Page 1 of 1
Sheet : Releases to Land AER Returns Workbook 23/3/2017 14:13
4.4 RELEASES TO LAND Link to previous years emissions data | PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | 23/03/2017 14:138 8 16 16 6 6 6 6
SECTION A : PRTR POLLUTANTSPlease enter all quantities in this section in KGs
QUANTITY
No. Annex II Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year0.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
SECTION B : REMAINING POLLUTANT EMISSIONS (as required in your Licence)Please enter all quantities in this section in KGs
QUANTITY
Pollutant No. Name M/C/E Method Code Designation or Description Emission Point 1 T (Total) KG/Year A (Accidental) KG/Year0.0 0.0 0.0
* Select a row by double-clicking on the Pollutant Name (Column B) then click the delete button
POLLUTANT METHODMethod Used
RELEASES TO LAND
RELEASES TO LAND
POLLUTANT METHODMethod Used
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 1 of 1
Sheet : Treatment Transfers of Waste AER Returns Workbook 23/3/2017 14:14
5. ONSITE TREATMENT & OFFSITE TRANSFERS OF WASTE | PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | 23/03/2017 14:145 59 Please enter all quantities on this sheet in Tonnes 13
Quantity (Tonnes per
Year)
Haz Waste : Name and Licence/Permit No of Next
Destination Facility Non Haz Waste: Name and Licence/Permit No of
Recover/Disposer
Haz Waste : Address of Next Destination Facility
Non Haz Waste: Address of Recover/Disposer
Name and License / Permit No. and Address of Final Recoverer /
Disposer (HAZARDOUS WASTE ONLY)
Actual Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Transfer DestinationEuropean Waste
Code Hazardous Quantity T/Year Description of Waste
Waste Treatment Operation M/C/E Method Used
Location of Treatment Name and Licence / Permit No. of Recoverer / Disposer / Broker Address of Recoverer / Disposer / Broker Name and Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY) Licence / Permit No. of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
To Other Countries 06 01 04 Yes 0.109 phosphoric and phosphorous acid D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 06 01 06 Yes 0.239 other acids D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 06 02 04 Yes 0.049 sodium and potassium hydroxide D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 06 02 04 Yes 12.727 sodium and potassium hydroxide D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 07 05 01 Yes 0.856 aqueous washing liquids and mother liquors D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 07 05 01 Yes 0.053 aqueous washing liquids and mother liquors D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 07 05 04 Yes 0.011other organic solvents, washing liquids and mother liquors D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 07 05 04 Yes 0.443other organic solvents, washing liquids and mother liquors D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
Within the Country 07 05 04 Yes 7.684other organic solvents, washing liquids and mother liquors R12 M Weighed Offsite in Ireland
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver Ireland SRF (Blending),W0036-02,Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
To Other Countries 07 05 13 Yes 0.746solid wastes containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 07 05 13 Yes 2.416solid wastes containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
Method Used
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 1 of 5
Sheet : Treatment Transfers of Waste AER Returns Workbook 23/3/2017 14:14
Quantity (Tonnes per
Year)
Haz Waste : Name and Licence/Permit No of Next
Destination Facility Non Haz Waste: Name and Licence/Permit No of
Recover/Disposer
Haz Waste : Address of Next Destination Facility
Non Haz Waste: Address of Recover/Disposer
Name and License / Permit No. and Address of Final Recoverer /
Disposer (HAZARDOUS WASTE ONLY)
Actual Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Transfer DestinationEuropean Waste
Code Hazardous Quantity T/Year Description of Waste
Waste Treatment Operation M/C/E Method Used
Location of Treatment Name and Licence / Permit No. of Recoverer / Disposer / Broker Address of Recoverer / Disposer / Broker Name and Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY) Licence / Permit No. of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Method Used
To Other Countries 07 05 13 Yes 27.303solid wastes containing dangerous substances D10 M Weighed Abroad AVG,IB 2234/AVG-GENB-2
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Within the Country 07 05 14 No 46.72solid wastes other than those mentioned in 07 05 13 R1 M Weighed Offsite in Ireland Indaver Ireland,W0167-03
Carranstown,Duleek,Co. Meath,.,Ireland
Within the Country 13 01 13 Yes 0.143 other hydraulic oils R12 M Weighed Offsite in IrelandIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver Ireland SRF (Blending),W0036-02,Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
To Other Countries 13 01 13 Yes 0.511 other hydraulic oils D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 13 01 13 Yes 0.056 other hydraulic oils D10 M Weighed AbroadIndaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Within the Country 13 05 03 Yes 19.88 interceptor sludges D9 M Weighed Offsite in IrelandEnva Environmental,W0196-01
John F. Kennedy Road,.,Naas Road,Dublin,Ireland
Enva Environmental,W0196-01,John F. Kennedy Road,.,Naas Road,Dublin,Ireland
John F. Kennedy Road,.,Naas Road,Dublin,Ireland
Within the Country 15 01 01 No 11.78 paper and cardboard packaging R3 M Weighed Offsite in Ireland
Padraig Thornton Recycling,WFP-DC-11-0023-11
Unit 6 S3B Henry Road,Parkwest Business Park,Dublin 12,.,Ireland
Within the Country 15 01 02 No 4.45 plastic packaging R3 M Weighed Offsite in IrelandIrish Packaging Recycling Ltd.,W0263-01
Ballymount Road ,Walkinstown,Dublin,12,Ireland
Within the Country 15 01 02 No 7.78 plastic packaging R3 M Weighed Offsite in Ireland
Padraig Thornton Waste Disposal Ltd.,WFP-DC-10-0021-02
Unit 51 Henry Road,Parkwest Business Park,Dublin 12,.,Ireland
Within the Country 15 01 07 No 20.221 glass packaging R5 M Weighed Offsite in IrelandJohn Gannon Concrete Ltd,WFP-WM-2014-05
Split Hill Quarries ,Kilbeggan ,Co. Westmeath,.,Ireland
To Other Countries 15 01 10 Yes 0.273packaging containing residues of or contaminated by dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 15 01 10 Yes 0.288packaging containing residues of or contaminated by dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
Within the Country 16 02 13 Yes 14.912
discarded equipment containing hazardous components (16) other than those mentioned in 16 02 09 to 16 02 12 R4 M Weighed Offsite in Ireland
Rehab Enterprises Limited,WFP-DS-10-0008-05
Unit 77 ,Broomhill Road ,Tallaght ,Dublin 24 ,Ireland
Rehab Enterprises Limited,WFP-DS-10-0008-05,Unit 77,Broomhill Road,Tallaght,Dublin 24,Ireland
Unit 77,Broomhill Road,Tallaght,Dublin 24,Ireland
To Other Countries 16 03 03 Yes 11.23inorganic wastes containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 2 of 5
Sheet : Treatment Transfers of Waste AER Returns Workbook 23/3/2017 14:14
Quantity (Tonnes per
Year)
Haz Waste : Name and Licence/Permit No of Next
Destination Facility Non Haz Waste: Name and Licence/Permit No of
Recover/Disposer
Haz Waste : Address of Next Destination Facility
Non Haz Waste: Address of Recover/Disposer
Name and License / Permit No. and Address of Final Recoverer /
Disposer (HAZARDOUS WASTE ONLY)
Actual Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Transfer DestinationEuropean Waste
Code Hazardous Quantity T/Year Description of Waste
Waste Treatment Operation M/C/E Method Used
Location of Treatment Name and Licence / Permit No. of Recoverer / Disposer / Broker Address of Recoverer / Disposer / Broker Name and Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY) Licence / Permit No. of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Method Used
To Other Countries 16 03 03 Yes 4.124inorganic wastes containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 16 03 05 Yes 28.034organic wastes containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 16 03 05 Yes 18.096organic wastes containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 16 03 05 Yes 30.097organic wastes containing dangerous substances D10 M Weighed Abroad AVG,IB 2234/AVG-GENB-2
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 16 05 04 Yes 0.038gases in pressure containers (including halons) containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
To Other Countries 16 05 04 Yes 0.05gases in pressure containers (including halons) containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 16 05 06 Yes 0.14
laboratory chemicals, consisting of or containing dangerous substances, including mixtures of laboratory chemicals D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 16 05 08 Yes 11.579discarded organic chemicals consisting of or containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver NV,MLAVI/9800000485,Poldervlietweg,.,2030 Antwerp,.,Belgium
Poldervlietweg,.,2030 Antwerp,.,Belgium
To Other Countries 16 05 08 Yes 20.214discarded organic chemicals consisting of or containing dangerous substances D10 M Weighed Abroad
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
AVG,IB 2234/AVG-GENB-2,Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Abfall-Verwertungs-Gesellschaft mbH,Borsigstrasse 2,22113 Hamburg,.,Germany
Within the Country 16 06 01 Yes 7.72 lead batteries R4 M Weighed Offsite in IrelandKMK Metals Recycling Ltd.,W0113-04
Cappincur Industrial Estate,.,Tullamore,Co. Offaly,Ireland
KMK Metals Recycling Ltd,W0113-04,Cappincur Industrial Estate,.,Tullamore,Co. Offaly,Ireland
Cappincur Industrial Estate,.,Tullamore,Co. Offaly,Ireland
Within the Country 17 04 05 No 26.862 iron and steel R4 M Weighed Offsite in IrelandA1 Metal Recycling Ltd,WFP-LS-14-0003-01
Acragar,Mountmellick,Co. Laois,.,Ireland
Within the Country 17 09 04 No 312.5
mixed construction and demolition wastes other than those mentioned in 17 09 01, 17 09 02 and 17 09 03 R5 M Weighed Offsite in Ireland
Padriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 3 of 5
Sheet : Treatment Transfers of Waste AER Returns Workbook 23/3/2017 14:14
Quantity (Tonnes per
Year)
Haz Waste : Name and Licence/Permit No of Next
Destination Facility Non Haz Waste: Name and Licence/Permit No of
Recover/Disposer
Haz Waste : Address of Next Destination Facility
Non Haz Waste: Address of Recover/Disposer
Name and License / Permit No. and Address of Final Recoverer /
Disposer (HAZARDOUS WASTE ONLY)
Actual Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Transfer DestinationEuropean Waste
Code Hazardous Quantity T/Year Description of Waste
Waste Treatment Operation M/C/E Method Used
Location of Treatment Name and Licence / Permit No. of Recoverer / Disposer / Broker Address of Recoverer / Disposer / Broker Name and Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY) Licence / Permit No. of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Method Used
Within the Country 18 01 04 No 9.24
wastes whose collection and disposal is not subject to special requirements in order to prevent infection (for example dressings, plaster casts, linen, disposable clothing, diapers) R1 M Weighed Offsite in Ireland Indaver Ireland,W0167-03
Carranstown,Duleek,Co. Meath,.,Ireland
Within the Country 19 13 07 Yes 2.437
aqueous liquid wastes and aqueous concentrates from groundwater remediation containing dangerous substances R12 M Weighed Offsite in Ireland
Indaver Ireland Limited,W0036-02
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Indaver Ireland SRF (Blending),W0036-02,Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Tolka Quay Road,Dublin Port,Dublin 1,.,Ireland
Within the Country 20 01 01 No 51.74 paper and cardboard R3 M Weighed Offsite in IrelandPadriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
Within the Country 20 01 01 No 11.35 paper and cardboard R3 M Weighed Offsite in Ireland
Padraig Thornton Recycling,WFP-DC-11-0023-11
Unit 6 S3B Henry Road,Parkwest Business Park,Dublin 12,.,Ireland
Within the Country 20 01 01 No 1.29 paper and cardboard R3 M Weighed Offsite in IrelandIrish Packaging Recycling Ltd.,W0263-01
Ballymount Road ,Walkinstown,Dublin,12,Ireland
Within the Country 20 01 08 No 17.542 biodegradable kitchen and canteen waste R3 M Weighed Offsite in IrelandThorntons Recycling,W0195-02
Ballynalurgan,.,Kells,Co. Meath,Ireland
Within the Country 20 01 08 No 1.739 biodegradable kitchen and canteen waste R3 M Weighed Offsite in IrelandPadriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
Within the Country 20 01 21 Yes 0.393fluorescent tubes and other mercury-containing waste R4 M Weighed Offsite in Ireland
Irish Lamps Recycling Ltd,WFP-KE-14-0072-01
Woodstock Industrial Estate,Athy,Co. Kildare,.,Ireland
Irish Lamps Recycling Ltd,WFP-KE-14-0072-01,Woodstock Industrial Estate,Athy,Co. Kildare,.,Ireland
Woodstock Industrial Estate,Athy,Co. Kildare,.,Ireland
Within the Country 20 01 33 Yes 0.324
batteries and accumulators included in 16 06 01, 16 06 02 or 16 06 03 and unsorted batteries and accumulators containing these batteries R4 M Weighed Offsite in Ireland
KMK Metals Recycling Ltd.,W0113-04
Cappincur Industrial Estate,.,Tullamore,Co. Offaly,Ireland
KMK Metals Recycling Ltd,W0113-04,Cappincur Industrial Estate,.,Tullamore,Co. Offaly,Ireland
Cappincur Industrial Estate,.,Tullamore,Co. Offaly,Ireland
Within the Country 20 01 38 No 35.22 wood other than that mentioned in 20 01 37 R3 M Weighed Offsite in IrelandPadriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
Within the Country 20 01 40 No 4.7 metals R4 M Weighed Offsite in IrelandMidland Waste Disposal Company Ltd,W0131-2
Clonmagaddan,Proudstown,Navan,Co. Meath,Ireland
Within the Country 20 01 40 No 115.47 metals R4 M Weighed Offsite in IrelandPadriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
Within the Country 20 02 01 No 22.64 biodegradable waste R3 M Weighed Offsite in IrelandPadriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
Within the Country 20 03 01 No 35.173 mixed municipal waste R1 M Weighed Offsite in IrelandPadriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
Within the Country 20 03 01 No 109.94 mixed municipal waste R3 M Weighed Offsite in Ireland
Padraig Thornton Waste Disposal Ltd.,WFP-DC-10-0021-02
Unit 51 Henry Road,Parkwest Business Park,Dublin 12,.,Ireland
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 4 of 5
Sheet : Treatment Transfers of Waste AER Returns Workbook 23/3/2017 14:14
Quantity (Tonnes per
Year)
Haz Waste : Name and Licence/Permit No of Next
Destination Facility Non Haz Waste: Name and Licence/Permit No of
Recover/Disposer
Haz Waste : Address of Next Destination Facility
Non Haz Waste: Address of Recover/Disposer
Name and License / Permit No. and Address of Final Recoverer /
Disposer (HAZARDOUS WASTE ONLY)
Actual Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Transfer DestinationEuropean Waste
Code Hazardous Quantity T/Year Description of Waste
Waste Treatment Operation M/C/E Method Used
Location of Treatment Name and Licence / Permit No. of Recoverer / Disposer / Broker Address of Recoverer / Disposer / Broker Name and Address of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY) Licence / Permit No. of Final Destination i.e. Final Recovery / Disposal Site (HAZARDOUS WASTE ONLY)
Method Used
Within the Country 20 03 07 No 128.86 bulky waste R1 M Weighed Offsite in IrelandPadriag Thornton Waste Disposal Ltd,W044-2
Thorntons Recycling Centre,Killeen Road,Ballyfermot,Dublin 10,Ireland
Within the Country 20 01 25 No 1.5 edible oil and fat R3 M Weighed Offsite in IrelandBEOFS Ltd.,WFP-KK-14-0010-02
Camphill Community,Ballytobin,Callan,Co. Kilkenny,Ireland
Within the Country 20 02 01 No 5.78 biodegradable waste R3 M Weighed Offsite in IrelandEnrich Environmental Ltd,WFP/MH/08/0004/02
Larch Hill Stud,Newtownrathganley,Kilcock,Co. Meath,Ireland
* Select a row by double-clicking the Description of Waste then click the delete button
| PRTR# : P0019 | Facility Name : Amgen Technology (Ireland) Unlimited Company | Filename : P0019_2016.xls | Return Year : 2016 | Page 5 of 5