P-SERIES Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. Job Name: System Reference: Date: Indoor Unit: PCA-A42KA6 Outdoor Unit: PUY-A42NHA6 (-BS) UNIT OPTION: Standard Model......................................................................PUY-A42NHA6 Seacoast (BS) Model.......................................................PUY-A42NHA6-BS ACCESSORIES: Indoor Unit Condensate Pump (BlueDiamond X87-711/721; 115/230V) Condensate Pump (Sauermann SI30-115/230; 115/230V) High-Efficiency Filter (PAC-SH90KF-E) iSee Sensor (PAC-SH91MK-E) Disconnect Switch (TAZ-MS303) Outdoor Unit Wind Baffle (WB-PA2 [x2])* *Allows operation to 0º F (-18º C). Air Outlet Guide (PAC-SG59SG-E [x2]) Wall Bracket (QSWB2000M-1) Controls Wireless Controller (MHK1) Advanced Wired Controller (PAR-31MAA) Simple Wired Controller (PAC-YT53CRAU) M-NET Adapter (PAC-SF83MA-E) Temperature Sensor (PAC-SE41TS) SPECIFICATIONS: Rated Conditions (Capacity / Input)* Cooling Btu/h / W 42,000 / 4,110 * Rating Conditions per AHRI Standard: Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB Capacity Range Cooling Btu/h 18,000 - 42,000 Operating Range Cooling 0º F** to 115º F (-18º C to 46º C) DB ** The minimum temperature will be 23º F (-5º C) DB if optional wind baffle accessory is not installed. AHRI Efficiency Ratings EER 10.2 SEER 15.8 Electrical Power Requirements 208 / 230V, 1-Phase, 60 Hz Minimum Circuit Ampacity (MCA) Indoor / Outdoor A 2 / 25 Indoor Unit Blower Motor (ECM) F.L.A. 0.97 Blower Motor Output W 160 SHF / Moisture Removal 0.69 / 11.7 pt./h Outdoor Unit Compressor DC INVERTER-driven Twin Rotary Fan Motor (ECM) F.L.A. 0.75 MOCP A 40 Airflow Rate (Low-M1-M2-Hi) Indoor (Cooling) DRY CFM 810-885-955-1,055 WET 740-810-885-955 Outdoor DRY 1,940 Sound Pressure Level Indoor (Low-M1-M2-Hi) dB(A) 39-41-43-45 Outdoor Cooling 51 External Dimensions Indoor (H x W x D) In.(mm) 9-1/16 x 63 x 26-3/4 (230 x 1,600 x 680) Outdoor (H x W x D) 53-1/8 x 37-3/8 x 13 + 1-3/16 (1,350 x 950 x 330 + 30) Net Weight Indoor Lbs.(kg) 84 (38) Outdoor 247 (112) External Finish Indoor Munsel No. 6.4Y 8.9/0.4 Outdoor Munsell No. 3Y 7.8 / 1.1 Refrigerant R410A ; 6lbs., 10oz. Refrigerant Piping (Flared) Liquid (High Pressure) In.(mm) 3/8 (9.52) Gas (Low Pressure) 5/8 (15.88) Maximim Total Refrigerant Pipe Length Ft. (m) 225 (68) Maximum Vertical Separation Ft. (m) 100 (30) PCA-A42KA6 & PUY-A42NHA6 (-BS) 42,000 BTU/H CEILING-SUSPENDED AIR-CONDITIONING SYSTEM

P-SIS PCA-A42KA6 & PUY-A42NHA6 (-BS) 42,000 …-BS... · Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally.) Piping

Embed Size (px)

Citation preview

P-SERIES

Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.

Job Name:

System Reference: Date:

Indoor Unit: PCA-A42KA6

Outdoor Unit: PUY-A42NHA6 (-BS)

UNIT OPTION: □ Standard Model......................................................................PUY-A42NHA6 □ Seacoast (BS) Model.......................................................PUY-A42NHA6-BS

ACCESSORIES: Indoor Unit

□ Condensate Pump (BlueDiamond X87-711/721; 115/230V) □ Condensate Pump (Sauermann SI30-115/230; 115/230V) □ High-Efficiency Filter (PAC-SH90KF-E) □ iSee Sensor (PAC-SH91MK-E) □ Disconnect Switch (TAZ-MS303)

Outdoor Unit

□ Wind Baffle (WB-PA2 [x2])**Allows operation to 0º F (-18º C).

□ Air Outlet Guide (PAC-SG59SG-E [x2]) □ Wall Bracket (QSWB2000M-1)

Controls

□ Wireless Controller (MHK1) □ Advanced Wired Controller (PAR-31MAA) □ Simple Wired Controller (PAC-YT53CRAU) □ M-NET Adapter (PAC-SF83MA-E) □ Temperature Sensor (PAC-SE41TS)

SPECIFICATIONS:

Rated Conditions (Capacity / Input)*

Cooling Btu/h / W 42,000 / 4,110

* Rating Conditions per AHRI Standard:Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WBCooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB

Capacity Range

Cooling Btu/h 18,000 - 42,000

Operating Range

Cooling 0º F** to 115º F (-18º C to 46º C) DB** The minimum temperature will be 23º F (-5º C) DB if optional wind baffle accessory is not installed.

AHRI Efficiency Ratings

EER 10.2

SEER 15.8

Electrical Power Requirements 208 / 230V, 1-Phase, 60 Hz

Minimum Circuit Ampacity (MCA)

Indoor / Outdoor A 2 / 25

Indoor Unit

Blower Motor (ECM) F.L.A. 0.97

Blower Motor Output W 160

SHF / Moisture Removal 0.69 / 11.7 pt./h

Outdoor Unit

Compressor DC INVERTER-driven Twin Rotary

Fan Motor (ECM) F.L.A. 0.75

MOCP A 40

Airflow Rate (Low-M1-M2-Hi)

Indoor (Cooling)

DRY

CFM

810-885-955-1,055

WET 740-810-885-955

Outdoor DRY 1,940

Sound Pressure Level

Indoor (Low-M1-M2-Hi)dB(A)

39-41-43-45

Outdoor Cooling 51

External Dimensions

Indoor (H x W x D)

In.(mm)

9-1/16 x 63 x 26-3/4 (230 x 1,600 x 680)

Outdoor (H x W x D) 53-1/8 x 37-3/8 x 13 + 1-3/16(1,350 x 950 x 330 + 30)

Net Weight

IndoorLbs.(kg)

84 (38)

Outdoor 247 (112)

External Finish

Indoor Munsel No. 6.4Y 8.9/0.4

Outdoor Munsell No. 3Y 7.8 / 1.1

Refrigerant R410A ; 6lbs., 10oz.

Refrigerant Piping (Flared)

Liquid (High Pressure)In.(mm)

3/8 (9.52)

Gas (Low Pressure) 5/8 (15.88)

Maximim Total Refrigerant Pipe Length Ft. (m) 225 (68)

Maximum Vertical Separation Ft. (m) 100 (30)

PCA-A42KA6 & PUY-A42NHA6 (-BS) 42,000 BTU/H CEILING-SUSPENDED AIR-CONDITIONING SYSTEM

Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.

1340 Satellite Boulevard. Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com

DIMENSIONS: PCA-A42KA6 & PUY-A42NHA6 (-BS) PCA-A42KA6

PUY-A42NHA6 (-BS)

FORM# PCA-A42KA6 - PUY-A42NHA6 (-BS) - 201507

NOTES: SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating• Fan Motor Support: Epoxy resin coating (at edge face)• Separator Assembly ; Valve Bed: Epoxy resin coating (at edge face)• Screws (used outer side): Zinc nickel coating 5μm + Polyvinylidene chloride coating

“Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants..

If the piping is installed in the backof the unit, remove the shaded portions fromthe component at right. Then, reinstall thecomponent in its original position (the heatexchanger might be clogged beause of dust.

ventilation

Unit: inch (mm)

If the piping is installed in the backof the unit, remove the shaded portions fromthe component at right. Then, reinstall thecomponent in its original position (the heatexchanger might be clogged beause of dust.

ventilation

Unit: mm (inch)

15

PUZ-A42NHA6 PUZ-A42NHA6-BS PUY-A42NHA6 PUY-A42NHA6-BS

Min

. 100

0mm

<39-

3/8>

Min

. 150

mm

<5-2

9/32

>

Min

. 10m

m<3

/8>

Min

. 10m

m<3

/8>

FRE

E

<Fou

ndat

ion

bolt

heig

ht>

FOUN

DATI

ON

Ser

vice

spa

ce

Term

inal

Blo

ckLe

ft···P

ower

sup

ply

wirin

gRi

ght··

··Ind

oor/O

utdo

or w

iring

Ear

th te

rmin

al

Ser

vice

pan

el

Han

dle

1 2

23<29/32>

1076<42-3/8>* 1 447<17-19/32>

* 1 443<17-7/16>

Han

dle

Fron

t pip

ing

cove

r

Rea

r pip

ing

cove

r

Air

Dis

char

ge

Rea

r Air

Inta

ke

Sid

e A

ir In

take

31<1-7/32>

145

<5-23

/32>

145

<5-23

/32>

220

<8-2

1/32

>30

<1-3

/16>

145

<5-23

/32>

81<3-3/16>219<8-5/8>

71<2-13/16>71

<2-1

3/16

>

Bot

tom

pip

ing

hole

(Kno

ckou

t)

Dra

in h

ole

5-[

33<1

-5/1

6>

Han

dle

Sid

e A

ir In

take

Air

inta

ke

Rea

r Air

Inta

ke

Han

dle

Han

dle

40<1

-9/1

6>

74<2

-19/

32>

Whe

n in

stal

ling

the

cond

uit.

Set

the

atta

chm

ent t

o th

e in

ner s

ide

of e

ach

pane

l.

2-[

22.2

<7/8

>1/

2 C

ondu

it at

tach

men

t45

<1-2

5/32>

40<1

-9/1

6>

65<2

-9/1

6>92

<3-5

/8>

27<1-1/16>55<2-3/16>

23<29/32>73<2-7/8>63<2-1/2>

Rea

r pip

ing

hole

(Kno

ckou

t)

Rea

r tru

nkin

g ho

le(K

nock

out)

Cond

uit ho

le (2-[2

7<1-1

/16>K

nock

out)

[92

<3-5

/8>

19<3

/4>55

<2-3

/16>

92<3

-5/8

>

75<2

-31/

32>

40<1

-9/1

6>

73<2-7/8>63<2-1/2>

23<29/32>27<1-1/16>92<3-5/8>R

ight

pip

ing

hole

(Kno

ckou

t)R

ight

trun

king

hol

e(K

nock

out)

Con

duit

hole

(2

-[27

<1-1

/16>

Kno

ckou

t)

[92

<3-5

/8>

92<3

-5/8

>65

<2-9

/16>

45<1

-25/

32>

40<1

-9/1

6>

27<1-1/16>55<2-3/16>

23<29/32>73<2-7/8>

63<2-1/2>

Fron

t pip

ing

hole

(Kno

ckou

t)

Fron

t tru

nkin

g ho

le(K

nock

out)

Con

duit

hole

(2

-[27

<1-1

/16>

Kno

ckou

t)

[92

<3-5

/8>

371<14-19/32>

330<13> 30<1-3/16>175<

6-7/

8>60

0<23

-5/8

>17

5<6-

7/8> 42

<1-2

1/32

>66

<2-5

/8>

950<

37-1

3/32

>32

2<12

-11/

16>

1350<53-5/32>

635<25>

19<3/4>417<16-13/32>

370<14-9/16>

2-U

Sha

ped

notc

hed

hole

(Fou

ndat

ion

Bol

t M10

<W3/

8>)

56<2-7/32>28<1-3/32>53<2-3/32>

45<1-25/32>

2-12o

36 O

val h

ole

(Fou

ndat

ion

Bol

t M10

<W3/

8>)

1···

·Ref

riger

ant G

AS p

ipe co

nnec

tion

(FLA

RE)[

15.8

8<5/

8>2

····R

efrig

eran

t LIQ

UID

pipe

conn

ectio

n (F

LARE

)[ 9

.52<

3/8>

*1 ··

··Ind

icatio

n of

STO

P VA

LVE

conn

ectio

n loc

ation

.

Exam

ple

of N

otes

1 FRE

E SPA

CE (A

round

the u

nit)

2 SE

RVIC

E SP

ACE

3 FOU

NDAT

ION

BOLT

S4 P

IPING

-WIR

ING

DIRE

CTIO

NS

Pipi

ng K

nock

out H

ole

Deta

ils

The

diag

ram

bel

ow s

hows

aba

sic e

xam

ple.

Expl

anat

ion

of p

artic

ular

det

ails

are

give

n in

the

inst

alla

tion

man

uals

etc.

Dim

ensio

ns o

f spa

ce n

eede

dfo

r ser

vice

acce

ss a

resh

own

in th

e be

low

diag

ram

.

Plea

se s

ecur

e th

e un

it fir

mly

with

4 fo

unda

tion

(M10

<W3/

8>)

bolts

. (Bo

lts a

nd w

ashe

rs m

ust

be p

urch

ased

loca

lly.)

Pip

ing

and

wiri

ng c

onne

ctio

nsca

n be

mad

e fro

m 4

dire

ctio

ns:

front

, rig

ht, r

ear a

nd b

elow

.

Min

.10

mm

<3/8

>

Min.500mm<19-11/16>

Min.

500m

m<1

9-11

/16>

Min.150mm<5-29/32>

Min.30mm<1-3/16>

Unit: mm<in>

OCH577