P-SERIES
Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.
Job Name:
System Reference: Date:
Indoor Unit: PCA-A42KA6
Outdoor Unit: PUY-A42NHA6 (-BS)
UNIT OPTION: □ Standard Model......................................................................PUY-A42NHA6 □ Seacoast (BS) Model.......................................................PUY-A42NHA6-BS
ACCESSORIES: Indoor Unit
□ Condensate Pump (BlueDiamond X87-711/721; 115/230V) □ Condensate Pump (Sauermann SI30-115/230; 115/230V) □ High-Efficiency Filter (PAC-SH90KF-E) □ iSee Sensor (PAC-SH91MK-E) □ Disconnect Switch (TAZ-MS303)
Outdoor Unit
□ Wind Baffle (WB-PA2 [x2])**Allows operation to 0º F (-18º C).
□ Air Outlet Guide (PAC-SG59SG-E [x2]) □ Wall Bracket (QSWB2000M-1)
Controls
□ Wireless Controller (MHK1) □ Advanced Wired Controller (PAR-31MAA) □ Simple Wired Controller (PAC-YT53CRAU) □ M-NET Adapter (PAC-SF83MA-E) □ Temperature Sensor (PAC-SE41TS)
SPECIFICATIONS:
Rated Conditions (Capacity / Input)*
Cooling Btu/h / W 42,000 / 4,110
* Rating Conditions per AHRI Standard:Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WBCooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB
Capacity Range
Cooling Btu/h 18,000 - 42,000
Operating Range
Cooling 0º F** to 115º F (-18º C to 46º C) DB** The minimum temperature will be 23º F (-5º C) DB if optional wind baffle accessory is not installed.
AHRI Efficiency Ratings
EER 10.2
SEER 15.8
Electrical Power Requirements 208 / 230V, 1-Phase, 60 Hz
Minimum Circuit Ampacity (MCA)
Indoor / Outdoor A 2 / 25
Indoor Unit
Blower Motor (ECM) F.L.A. 0.97
Blower Motor Output W 160
SHF / Moisture Removal 0.69 / 11.7 pt./h
Outdoor Unit
Compressor DC INVERTER-driven Twin Rotary
Fan Motor (ECM) F.L.A. 0.75
MOCP A 40
Airflow Rate (Low-M1-M2-Hi)
Indoor (Cooling)
DRY
CFM
810-885-955-1,055
WET 740-810-885-955
Outdoor DRY 1,940
Sound Pressure Level
Indoor (Low-M1-M2-Hi)dB(A)
39-41-43-45
Outdoor Cooling 51
External Dimensions
Indoor (H x W x D)
In.(mm)
9-1/16 x 63 x 26-3/4 (230 x 1,600 x 680)
Outdoor (H x W x D) 53-1/8 x 37-3/8 x 13 + 1-3/16(1,350 x 950 x 330 + 30)
Net Weight
IndoorLbs.(kg)
84 (38)
Outdoor 247 (112)
External Finish
Indoor Munsel No. 6.4Y 8.9/0.4
Outdoor Munsell No. 3Y 7.8 / 1.1
Refrigerant R410A ; 6lbs., 10oz.
Refrigerant Piping (Flared)
Liquid (High Pressure)In.(mm)
3/8 (9.52)
Gas (Low Pressure) 5/8 (15.88)
Maximim Total Refrigerant Pipe Length Ft. (m) 225 (68)
Maximum Vertical Separation Ft. (m) 100 (30)
PCA-A42KA6 & PUY-A42NHA6 (-BS) 42,000 BTU/H CEILING-SUSPENDED AIR-CONDITIONING SYSTEM
Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.
1340 Satellite Boulevard. Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com
DIMENSIONS: PCA-A42KA6 & PUY-A42NHA6 (-BS) PCA-A42KA6
PUY-A42NHA6 (-BS)
FORM# PCA-A42KA6 - PUY-A42NHA6 (-BS) - 201507
NOTES: SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating• Fan Motor Support: Epoxy resin coating (at edge face)• Separator Assembly ; Valve Bed: Epoxy resin coating (at edge face)• Screws (used outer side): Zinc nickel coating 5μm + Polyvinylidene chloride coating
“Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants..
If the piping is installed in the backof the unit, remove the shaded portions fromthe component at right. Then, reinstall thecomponent in its original position (the heatexchanger might be clogged beause of dust.
ventilation
Unit: inch (mm)
If the piping is installed in the backof the unit, remove the shaded portions fromthe component at right. Then, reinstall thecomponent in its original position (the heatexchanger might be clogged beause of dust.
ventilation
Unit: mm (inch)
15
PUZ-A42NHA6 PUZ-A42NHA6-BS PUY-A42NHA6 PUY-A42NHA6-BS
Min
. 100
0mm
<39-
3/8>
Min
. 150
mm
<5-2
9/32
>
Min
. 10m
m<3
/8>
Min
. 10m
m<3
/8>
FRE
E
<Fou
ndat
ion
bolt
heig
ht>
FOUN
DATI
ON
Ser
vice
spa
ce
Term
inal
Blo
ckLe
ft···P
ower
sup
ply
wirin
gRi
ght··
··Ind
oor/O
utdo
or w
iring
Ear
th te
rmin
al
Ser
vice
pan
el
Han
dle
1 2
23<29/32>
1076<42-3/8>* 1 447<17-19/32>
* 1 443<17-7/16>
Han
dle
Fron
t pip
ing
cove
r
Rea
r pip
ing
cove
r
Air
Dis
char
ge
Rea
r Air
Inta
ke
Sid
e A
ir In
take
31<1-7/32>
145
<5-23
/32>
145
<5-23
/32>
220
<8-2
1/32
>30
<1-3
/16>
145
<5-23
/32>
81<3-3/16>219<8-5/8>
71<2-13/16>71
<2-1
3/16
>
Bot
tom
pip
ing
hole
(Kno
ckou
t)
Dra
in h
ole
5-[
33<1
-5/1
6>
Han
dle
Sid
e A
ir In
take
Air
inta
ke
Rea
r Air
Inta
ke
Han
dle
Han
dle
40<1
-9/1
6>
74<2
-19/
32>
Whe
n in
stal
ling
the
cond
uit.
Set
the
atta
chm
ent t
o th
e in
ner s
ide
of e
ach
pane
l.
2-[
22.2
<7/8
>1/
2 C
ondu
it at
tach
men
t45
<1-2
5/32>
40<1
-9/1
6>
65<2
-9/1
6>92
<3-5
/8>
27<1-1/16>55<2-3/16>
23<29/32>73<2-7/8>63<2-1/2>
Rea
r pip
ing
hole
(Kno
ckou
t)
Rea
r tru
nkin
g ho
le(K
nock
out)
Cond
uit ho
le (2-[2
7<1-1
/16>K
nock
out)
[92
<3-5
/8>
19<3
/4>55
<2-3
/16>
92<3
-5/8
>
75<2
-31/
32>
40<1
-9/1
6>
73<2-7/8>63<2-1/2>
23<29/32>27<1-1/16>92<3-5/8>R
ight
pip
ing
hole
(Kno
ckou
t)R
ight
trun
king
hol
e(K
nock
out)
Con
duit
hole
(2
-[27
<1-1
/16>
Kno
ckou
t)
[92
<3-5
/8>
92<3
-5/8
>65
<2-9
/16>
45<1
-25/
32>
40<1
-9/1
6>
27<1-1/16>55<2-3/16>
23<29/32>73<2-7/8>
63<2-1/2>
Fron
t pip
ing
hole
(Kno
ckou
t)
Fron
t tru
nkin
g ho
le(K
nock
out)
Con
duit
hole
(2
-[27
<1-1
/16>
Kno
ckou
t)
[92
<3-5
/8>
371<14-19/32>
330<13> 30<1-3/16>175<
6-7/
8>60
0<23
-5/8
>17
5<6-
7/8> 42
<1-2
1/32
>66
<2-5
/8>
950<
37-1
3/32
>32
2<12
-11/
16>
1350<53-5/32>
635<25>
19<3/4>417<16-13/32>
370<14-9/16>
2-U
Sha
ped
notc
hed
hole
(Fou
ndat
ion
Bol
t M10
<W3/
8>)
56<2-7/32>28<1-3/32>53<2-3/32>
45<1-25/32>
2-12o
36 O
val h
ole
(Fou
ndat
ion
Bol
t M10
<W3/
8>)
1···
·Ref
riger
ant G
AS p
ipe co
nnec
tion
(FLA
RE)[
15.8
8<5/
8>2
····R
efrig
eran
t LIQ
UID
pipe
conn
ectio
n (F
LARE
)[ 9
.52<
3/8>
*1 ··
··Ind
icatio
n of
STO
P VA
LVE
conn
ectio
n loc
ation
.
Exam
ple
of N
otes
1 FRE
E SPA
CE (A
round
the u
nit)
2 SE
RVIC
E SP
ACE
3 FOU
NDAT
ION
BOLT
S4 P
IPING
-WIR
ING
DIRE
CTIO
NS
Pipi
ng K
nock
out H
ole
Deta
ils
The
diag
ram
bel
ow s
hows
aba
sic e
xam
ple.
Expl
anat
ion
of p
artic
ular
det
ails
are
give
n in
the
inst
alla
tion
man
uals
etc.
Dim
ensio
ns o
f spa
ce n
eede
dfo
r ser
vice
acce
ss a
resh
own
in th
e be
low
diag
ram
.
Plea
se s
ecur
e th
e un
it fir
mly
with
4 fo
unda
tion
(M10
<W3/
8>)
bolts
. (Bo
lts a
nd w
ashe
rs m
ust
be p
urch
ased
loca
lly.)
Pip
ing
and
wiri
ng c
onne
ctio
nsca
n be
mad
e fro
m 4
dire
ctio
ns:
front
, rig
ht, r
ear a
nd b
elow
.
Min
.10
mm
<3/8
>
Min.500mm<19-11/16>
Min.
500m
m<1
9-11
/16>
Min.150mm<5-29/32>
Min.30mm<1-3/16>
Unit: mm<in>
OCH577