Upload
yabrebeny
View
271
Download
17
Embed Size (px)
Citation preview
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
1/29
HUAWEI TECHNOLOGIES CO., LTD.
06.April 2006
HUAWEI TECHNOLOGIES Co., Ltd.
www.huawei.com
HUAWEI Confidential
Security Level:
Page 1
Msoftx3000 inter-working
with BSC data configuration
(Based on TDM)
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
2/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 2
Objectives:
After learning this course, you should master that:
1. Acknowledge relative basic concepts of BSSAP and functions of A
interface.
2. Perform data configuration from MSOFTX3000 to BSC.
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
3/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 3
References
MSOFTX3000 Data configuration Manual
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
4/29HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 4
Chapter1 Relative Concepts
Chapter2 Configuration Procedure
Chapter3 About number analysis
Chapter4 Debugging Command
Course Contents
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
5/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 5
Review
Network with BSC.
BSC
TDM
MSC-SRV
MGW (Semi-permanent)
TDM
BSSAP
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
6/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 6
DDF Rack Connect
ME32
0 1 2 3 4 5 6 7
MSX3000 PSTN BSC
MEPI
0 1 2 3 4 5 6 7
UMG89
00
Jump lineConnect cap
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
7/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 7
Semi-permanent connecting Mode
BSC-2
BSC-1
MSOFTX3000 UMG8900
TDM bearer
TDM bearer
TDM bearer
E32EPI
TDM bearer
TDM bearer
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
8/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 8
Protocol Stack
MSC-SRVMGW (Semi-permanent) BSC
MTP1
MTP2MTP3
SCCP
BSSAP
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
9/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 9
Chapter1 Relative Concepts
Chapter2 Configuration Procedure
Chapter3 About number analysis
Chapter4 Debugging Command
Course Contents
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
10/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 10
Which broad can process these protocols?
MTP1
MTP2
MTP3
SCCP
BSSAP
CCU/CSU
CPC
EPI
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
11/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 11
Data Configuration Based on Protocol Stack
MTP1
MTP2
MTP3
ADD N7DSP
ADD N7LKSADD N7RT
ADD N7LNK
SCCPADD SCCPDSP
ADD SCCPSSN
BSSAP
ADD CALLSRC
ADD OFCADD BSC
ADD LAIGCILAI
ADD LAIGCIGCI
ADD RANMGW
The last step:(Config A circuit)
ADD ACPOOL
ADD AIETG
ADD AIETKCMOD AIETKC
Dont Forget:
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
12/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 12
Configuration steps1.Data prepare (negotiated data):
MSC SERVER
DPC
network
indicator
SLC
SLC send
link type
CIC
BSC
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
13/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 13
Configuration steps
The MTP3 layer data Configuration has been introduced In the HLR
configuration lecture. so well learn about sccp layer and upper layers.
SCCPADD SCCPDSP
ADD SCCPSSNBSSAP: local-local
and local-remote
SCMG: local-remote
DPC: BSCS
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
14/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 14
Next Step
1.
BSSA
P
ADD CALLSRCADD OFC
ADD BSC
ADD LAIGCILAI
ADD LAIGCIGCI
ADD RANMGW
Define a call sourcecode and
output a route selectionsource code (RSSC)
Used for RTANA
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
15/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 15
Next Step
2.
BSSA
P
ADD CALLSRC
ADD OFCADD BSC
ADD LAIGCILAI
ADD LAIGCIGCIADD RANMGW
The office means thelocal office has directconnection with remoteoffice to transfer
speech service.Here is BSC.
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
16/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 16
Next Step
3.
BSSA
P
ADD CALLSRC
ADD OFC
ADD BSCADD LAIGCILAI
ADD LAIGCIGCIADD RANMGW
Define a BSC
Note: RSSC come from
ADD CALLSRC.
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
17/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 17
Next Step
4.
BSSA
P
ADD CALLSRC
ADD OFC
ADD BSC
ADD LAIGCILAI
ADD LAIGCIGCI
ADD RANMGW
Define a LAI and GCI of
the BSC.
The data based on theplan.
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
18/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 18
Next Step
5.
BSSA
P
ADD CALLSRC
ADD OFC
ADD BSC
ADD LAIGCILAI
ADD LAIGCIGCI
ADD RANMGW
Define a MGW which isresponsible for this
BSC office.
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
19/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 19
A interface circuit configuration
A intereface:
Start circuit No.
End circuit No.
Start CIC
Start TID
ADD ACPOOL
ADD AIETG
ADD AIETKC
MOD AIETKC
Add A
circuit pool
Add a
trunk group
Modify the
synchronous
Slot and
Signal slot
unused
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
20/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 20
How to configure a circuit?
Circuit No.
(MSX
resource)
CIC
(Negotiation
Para)
TID (UMG
resource)
BSC
Within aCCU/CSU
Within a
VMGW
Within an OFC
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
21/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 21
Chapter1 Relative Concepts
Chapter2 Configuration Procedure
Chapter3 About number analysis
Chapter4 Debugging Command
Course Contents
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
22/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 22
ProcedureAfter configure HLR and BSC data, If you wanna make a call,
you must do a number analysis.
1. 117 report time.
ADD CNACLDPFX: 117;
DNPREPARE:YES
ADD PFXPRO
UMG begin to send tone
PFX:117;
ST Flag: send tone
TT:117 tone
Then you can make a 117 call
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
23/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 23
Procedure2. Local office calling.
ADD CNACLD
PFX:139(MSISDN head);
ICLDTYPE: MS
ADD CNACLD
PFX:1374755(MSRN head);ICLDTYPE: MSRNRSC:65535(default means within
local office)Paging direct
Go to GT table (MSISDN)
Then you can make a local office call
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
24/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 24
Chapter1 Relative Concepts
Chapter2 Configuration
Procedure
Chapter3 About number analysis
Chapter4 Debugging Command
Course Contents
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
25/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 25
Command
DSP N7LNK
DSP N7RTDSP N7DSP
MTP1
MTP2
MTP3
SCCP
BSSAP
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
26/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 26
Command
MTP1
MTP2MTP3
SCCP
BSSAP
DSP SCCPDSP
DSP SCCPSSN
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
27/29
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 27
Command
MTP1
MTP2
MTP3
SCCP
BSSAPDSP AIETKC
RST AIETKC
BLK AIETKC
UBL AIETKC
DSP OFTK
DSP TGTK
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
28/29
06 April 2006 Security Level:
8/12/2019 OWG000205 Msoftx3000 to BSC Data Configuration (TDM)-Issue1.3
29/29
HUAWEI TECHNOLOGIES CO., LTD.
06.April 2006
HUAWEI TECHNOLOGIES Co., Ltd.
www.huawei.com
HUAWEI Confidential
Security Level:
Page 29
Thank You
www.huawei.com