Upload
abd961
View
28
Download
10
Embed Size (px)
DESCRIPTION
dffd
Citation preview
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
www.huawei.com
Internal
OWF001202 HLR9820 SAU Hardware & Local
office DataISSUE 2.2
HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved
Introduction
Hardware data configuration is the first step of SAU data configuration.
After this course, trainees will understand HLR9820 hardware in-depth.
HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved
Upon completion of this course, you will be able to:
Master the hardware& local office data configuration.
Master all the logical NO. principle.
HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
Chapter 2 Data configurationChapter 2 Data configuration
Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command
Chapter 4 Configuration exampleChapter 4 Configuration example
HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved
HLR9820 data works for:SAU (Signaling Processing)
HDU (MAP Services Processing)
The data is configured in:LMT (For SAU)
Hardware Data
Local Office Information
Signaling Data
SMU Client (For HDU)
Global Data
Where is the data configured?
HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
1.1 Elements and position1.1 Elements and position
1.2 Module1.2 Module
1.3 Preparations1.3 Preparations
1.4 Data 1.4 Data configconfig. sequence. sequence
HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved
Elements and position
Module structure
HLR9820
Cabinet Cabinet
Frame Frame
Board Board
…
…
…
HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved
Elements and position
Cabinet
HLR9820 has 1 or 2 cabinets.
HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved
Elements and position
Frame and board
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
W B S G
WCCU
W C C U
W B S G
WIFM
PSM
WCSU
WCSU
WS M U
W H S C
WEPI
WEPI
WSIU
WCKI
WCKI
WBFI
WBFI
W S I U
W S I U
Front
Back
WIFM
W S M U
PSM
PSM
PSM
SAU has two kinds of frames:
basic frame and expansion frame.
There are 1 basic and two
expansion frames in full
configuration.
Only IBM solution has expansion
frame. It depends on numbers of
subscriber.
Front board and back board
HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved
Elements and position
Type and function of the boards
ATM Interface Board WEPIE1 ATM forwardWEAM
Clock Interface Board WCKI--
Hot-swap Control Board WHSC--
Power Supply BoardPSMPower Supply Board PSM
Alarm Board WALU
Back Far End Interface Board
WBFIIP Transferring Module Board WIFM
--Broadband Signaling Processing Board
WBSG
E1 Interface Board WEPICall Control and Signaling Processing Board
WCSU
--Call Control Board WCCU
System Interface Board WSIUSystem Management Board WSMU
Back boardFront board
HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved
Elements and position
Number of devices
To help in recognizing all categories of module components, it is necessary to number those of the same category uniformly.
Shelf number To recognize individual shelves easily, each shelf is
given a number, called shelf number. The shelf with the basic frame is numbered as Shelf 0.
HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved
Elements and position
Number of devices
Frame number
The system can support ten frames at most, numbering from 0 to 9.
The basic frame in the integrated configuration shelf is numbered as Frame 0.
HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved
The 8-bit Dual Inline Package (DIP) S3 of SIU is provided for setting frame numbers. The corresponding setting table is shown in follow
Elements and position
offononoffonononon9
onononoffonononon8
offoffoffononononon7
onoffoffononononon6
offonoffononononon5
ononoffononononon4
offoffonononononon3
onoffonononononon2
offononononononon1
onononononononon0
12345678DIPFrame No.
HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved
Slot numberSlot number is used to identify the slot of a specific
board that is inserted into a frame.
Each frame contains 21 slots at most (No. from 0 to 20)
Elements and position
HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
1.1 Elements and position1.1 Elements and position
1.2 Module1.2 Module
1.3 Preparations1.3 Preparations
1.4 Data 1.4 Data configconfig. sequence. sequence
HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved
Module
Module number
Module number is set according to the type of the board and is numbered from 2.
Modules of the same board are numbered uniquely. Here are the numbering rules:
WSMU Module number: 2~21WCCU/WCSU Module number: 22~101WEAM/WIFM/WBSG Module number: 132~211
HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
1.1 Elements and position1.1 Elements and position
1.2 Module1.2 Module
1.3 Preparations1.3 Preparations
1.4 Data 1.4 Data configconfig. sequence. sequence
HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved
Preparations
Before the data configuration, you should know
The networking and configuration conditions
The requirements put forward during engineering design stage
The local office information (SPC/HLR No./CC etc.)
HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved
Common MML commands
Start online modeLON
Start offline modeLOF
Set data or statusSET
Query status of related equipment and resourceDSP
Query database dataLST
Delete database dataRMV
Modify database dataMOD
Add database dataADD
FunctionCommand
HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved
Offline
Set format status to OFFSET FMT: STS=OFF
Set the alarm output switch of the current workstation to OFFSET CWSON: SWT=OFF
Start the offline modeLOF
Function Command or step
If it is the initial data configuration for the deployment:
HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved
Online
Remove two Wireless System Management Units (WSMUs) to simulate equipment power-down and then load data. Loading data in power-down status
Format all data of all modulesFMT
Set format status to ONSET FMT: STS=ON
Set the alarm output switch of the current workstation to ONSET CWSON: SWT=ON
Start the online modeLON
FunctionCommand or step
After that, how to load the data to switch?
HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
1.1 Elements and position1.1 Elements and position
1.2 Module1.2 Module
1.3 Preparations1.3 Preparations
1.4 Data 1.4 Data configconfig. sequence. sequence
HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved
HLR9820 Data Configuration Sequence
Start
End
Configure local office information
Configure signaling data
Configure hardware data
Start
End
Configure local office information
Configure signaling data
Configure hardware data
HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved
Questions
What’s the numbering principle of shelf, frame, board?
Which board has module number?
Can boards in same module exist in different frames?
What’s the difference of online and offline mode?
HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
Chapter 2 Data configurationChapter 2 Data configuration
Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command
Chapter 4 Configuration exampleChapter 4 Configuration example
HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved
Chapter 2 Data configurationChapter 2 Data configuration
2.1 Configuration Flow2.1 Configuration Flow
2.2 Data configuration2.2 Data configuration
HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved
Configuration FlowAdd ShelfAdd Shelf
Add FramesAdd Frames
Add BoardsAdd Boards
Add WCSUAdd WCSU Add WCKIAdd WCKI
Add WIFMAdd WIFM
Add WEPIAdd WEPI
Conf. E1Conf. E1
Conf. clock ModeConf. clock Mode
Conf. FEConf. FEConf. CPCConf. CPC
Conf. MEMConf. MEM
Clock Refer.Clock Refer.
Add WCCUAdd WCCU
Set Local OfficeInformation
Set Local OfficeInformation
HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved
Configuration Flow for ATMAdd ShelfAdd Shelf
Add FramesAdd Frames
Add BoardsAdd Boards
Add WEAMAdd WEAM Add WCKIAdd WCKI
Add WEPIAdd WEPI
Conf. IMA/UNIConf. IMA/UNI
Conf. clock ModeConf. clock Mode
Conf. MEMConf. MEM
Clock Refer.Clock Refer. Conf. PVCConf. PVC
Add WCCUAdd WCCU
Conf. E1Conf. E1
Set Local OfficeInformation
Set Local OfficeInformation
HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved
Chapter 2 Data configurationChapter 2 Data configuration
2.1 Configuration Flow2.1 Configuration Flow
2.2 Data configuration2.2 Data configuration
HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved
Commands
Adding Shelf
Adding Frame
Adding Board
Adding E1
Setting Clock Mode
Adding Board Clock Reference Source
Adding FE Configuration
Adding MEM Configuration
Adding IMA group
Adding IMA link
Adding UNI link
Adding PVC link
Set Local Office Information
HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved
Shelf/Frames/Boards
Relationship
[Shelf Number][Location Title][Position Number][RoW Number][Column Number]
ADD SHF[Frame Number][Shelf Number][Position Number]
ADD FRM
[Frame Number][Slot Number][Location]
ADD BRD
HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved
Shelf/Frames/Boards
Add Shelf
For HLR9820 SAU, there is only one shelf. The number always is 0.
HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved
Shelf/Frames/Boards
Add Frames
• For SUN solution, there is only one frame. The frame number is always 0.• For IBM Solution, there are three frames at maximum configuration. The frame number are from 0 to 2.
HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved
Shelf/Frames/Boards
Add Boards
Before adding the boards, the frame and shelf to which the boards belong must have already been added.
WSMU/WALU/PSM will be added automatically after the frame has been added.
If parameters need to be modified, please delete the board at first then add it again.
Two pieces of CPC will be added automatically after the WCSU has been added.
HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved
Add E1
Configure the WEPI if the module needs to process the SS7.
HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved
Set Clock Mode
Only for TDM/ATM networking
SET CKICFG: CL=LEVEL2, WM=MANUAL, MCS=LCK1;
HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved
Board Clock Reference Source
Only for TDM/ATM networking
After configuring clock mode
Parameter indicate the physical position:• Frame No.• Slot No.• E1 No.
HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved
Add FE configuration
Function:
WIFM/WBFI is the interface between SAU and IP network. They process MAC and IP protocol.
WIFM deliver IP package to WBSG.
We need setup FE (Fast Ethernet) interface for signaling traffic.
HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved
Add MEM configuration
Function:
Setup the connection between SAU and HDU
HUAWEI TECHNOLOGIES CO., LTD. Page 40All rights reserved
WCSU/WCCUWHSC0
WHSC1
HDU1#
HDU2#
LAN
SWITCH
LAN
SWITCH
WCSU/WCCU
MODULE
Hardware Connection
HUAWEI TECHNOLOGIES CO., LTD. Page 41All rights reserved
Command
ADD MEMCFG
Module: Module No. of WCCU/WCSU.
Local IP address: IP of WCSU. it is defined by this command.
Remote IP address: IP of HDU. Come from HDU.
Remote Port: IP port of HDU, always be 16500.
MEM Configuration
HUAWEI TECHNOLOGIES CO., LTD. Page 42All rights reserved
Command
ADD IMAGRP
WEAM Module: Module No. of .WEAM
IMA Group No.: Number of IMA group, ranging from 0 to 7.
Add IMA group
HUAWEI TECHNOLOGIES CO., LTD. Page 43All rights reserved
Command
ADD IMALNK
WEAM Module: Module No. of WEAM
IMA Group No.: Number of IMA group, ranging from 0 to 7.
IMA link port no: Number of the E1 port added to the IMA group
Add IMA link
HUAWEI TECHNOLOGIES CO., LTD. Page 44All rights reserved
Command
ADD UNILNK
WEAM Module: Module No. of WEAM
UNI link port no: Number of the E1 port added to the IMA group
Add UNI link
HUAWEI TECHNOLOGIES CO., LTD. Page 45All rights reserved
Command
ADD PVCLNK
PVC link number: Number of the global PVC links
VPI: Virtual path identifier (VPI)
VCI: virtual channel identifier (VCI)
Signal distribution module number:
Signal handle module number:
IMA group number:
UNI port number:
Add PVC link
HUAWEI TECHNOLOGIES CO., LTD. Page 46All rights reserved
Command
Set OFI
Signaling point code (SPC)
Signaling network where the local office resides (NI)
Network Structure
Whether the local office is a signaling transfer point (STP)
Add OFI
Signaling point code (SPC)
Set Local Office Information
HUAWEI TECHNOLOGIES CO., LTD. Page 47All rights reserved
Questions
What’s the sequence for hardware data conf.?
Which board will be added automatically after a frame has been added?
How to make the data active in switch after we configure the data offline?
What conditions are needed for E1 configuration?
HUAWEI TECHNOLOGIES CO., LTD. Page 48All rights reserved
Answer
1 Add shelf-> Add frame-> Add board->others
2 WSMU,WALU和PSM。
Use FMT to format data. Use LON to set online. Then load it.
We need add WCSU and WEPI at first.
HUAWEI TECHNOLOGIES CO., LTD. Page 49All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
Chapter 2 Data configurationChapter 2 Data configuration
Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command
Chapter 4 Configuration exampleChapter 4 Configuration example
HUAWEI TECHNOLOGIES CO., LTD. Page 50All rights reserved
3.1 Query Hardware3.1 Query Hardware
3.2 Query clock reference3.2 Query clock reference
3.3 Query E1/CPC configuration3.3 Query E1/CPC configuration
3.4 Query IP link3.4 Query IP link
3.5 Query IMA/UNI link3.5 Query IMA/UNI link
3.6 Query Port Status3.6 Query Port Status
3.7 Query Local Office3.7 Query Local Office
Chapter 3 Chapter 3 Relative maintenance commandRelative maintenance command
HUAWEI TECHNOLOGIES CO., LTD. Page 51All rights reserved
Query The Hardware
LST SHF
Example: LST SHF: SN=0;
LST FRM
Example: LST FRM: FN=0, SN=0;
DSP FRM
Example: DSP FRM: FN=0;
HUAWEI TECHNOLOGIES CO., LTD. Page 52All rights reserved
Query The Hardware
LST BRD
Example: LST BRD: FN=0, SN=0, LOC=FRONT;
DSP BRD
Example: DSP BRD: FN=0, SN=0, PSN=FB;
HUAWEI TECHNOLOGIES CO., LTD. Page 53All rights reserved
Query clock reference
LST CKICFG
Example: LST CKICFG:;
DSP CLKPH
Example: DSP CLKPH: FN=0;
DSP BRD (Query status of clock reference)
Example: DSP BRD: FN=0, SN=13, PSN=BB;
HUAWEI TECHNOLOGIES CO., LTD. Page 54All rights reserved
Query E1/CPC configuration
LST EPICFG
Example: LST EPICFG: FN=0, SN=0;
DSP BRD
Example: DSP BRD: FN=0, SN=0, PSN=BB;
Display E1 status
Example: DSP PORT: FN=0, SN=0, PT=E1, E1PN=2;
LST CPCCFG
Example: LST CPCCFG: FM=22, LOC=UPMC;
HUAWEI TECHNOLOGIES CO., LTD. Page 55All rights reserved
Query IP link
List FE configuration
Example: LST FECFG: MN=134;
Display FE status
Example: DSP PORT: FN=0, SN=10, PT=FE, FEPN=2;
HUAWEI TECHNOLOGIES CO., LTD. Page 56All rights reserved
Query IMA/UNI link
List IMA link configuration
Example: LST IMALNK: MN=132, IGN=1, IPN=0;
Display IMA link status
Example: DSP IMALNK: MN=132, IGN=1, IPN=0;
List UNI link configuration
Example: LST UNILNK: MN=133;
Display UNI link status
Example: LST UNILNK: MN=133;
HUAWEI TECHNOLOGIES CO., LTD. Page 57All rights reserved
Query Port Status (MEM FE)
To check connection between SAU and HDU
List MEMFE link configuration
Example: LST MEMCFG: MN=22;
Display MEMFE link status
Example: DSP MEMFE: MN=22;
HUAWEI TECHNOLOGIES CO., LTD. Page 58All rights reserved
Query Local Office Information
List local office information
Example: LST OFI;
HUAWEI TECHNOLOGIES CO., LTD. Page 59All rights reserved
Questions
What’s the difference between LST and DSP?
Which command is to check current clock reference?
HUAWEI TECHNOLOGIES CO., LTD. Page 60All rights reserved
Answer
LST is for query static data; DSP is for query the status of frame/board etc.
DSP BRD is used to check current clock reference. (Board is active WCKI)
HUAWEI TECHNOLOGIES CO., LTD. Page 61All rights reserved
Summary After hardware data configuration, please load it to switch. Then query whether the status of hardware is normal.
HUAWEI TECHNOLOGIES CO., LTD. Page 62All rights reserved
Chapter 1 Basic conceptsChapter 1 Basic concepts
Chapter 2 Data configurationChapter 2 Data configuration
Chapter 3 Relative maintenance commandChapter 3 Relative maintenance command
Chapter 4 Configuration exampleChapter 4 Configuration example
HUAWEI TECHNOLOGIES CO., LTD. Page 63All rights reserved
Example for hardware
IP address of WIFM: 191.169.100.10;
Mask: 255.255.0.0;
Gateway: 191.169.1.2 。
P
S
M
P
S
M
W
A
L
U
W
B
S
G
W
B
S
G
W
I
F
M
W
I
F
M
W
S
M
U
W
S
M
U
W
E
A
M
W
E
AM
W
C
C
U
W
C
C
U
W
C
S
U
W
C
S
U
20191817161514131211109876543210
HUAWEI TECHNOLOGIES CO., LTD. Page 64All rights reserved
True
Support of GPRS short message
True True GSM PHASE2NORESTRICTION
Support of PSI valueAnytime interrogation supportMAP versionNumber structure
limitation
NORESTRICTION3FalseTrue
Forwarded area limitation
Repetition times of ALERT_SC failCancel SCSupport of Message
waiting information
3FalseFalseTrue
Maximum times of Call Forward
Not support CAMEL phrase 1MAP version 0902620Support of USSD
function value
MAP information
755868613807550000
Area codeCountry codeLocal GTMobile network
information
EE024bitsNational
SPCNetwork structureNetwork IdentifySignaling point
Configuration dataItem
Example
HUAWEI TECHNOLOGIES CO., LTD. Page 65All rights reserved
Example for hardware
1 set offline mode
Offline------------------------LOF:;
Turn off alarm switch------------------------SET CWSON: SWT=OFF;
Turn off format switch------------------------
SET FMT: STS=OFF;
HUAWEI TECHNOLOGIES CO., LTD. Page 66All rights reserved
Example for hardware
2 Add Hardware
Add shelf------------------------ADD SHF: SN=0, LT="HW_TC", PN=0, RN=0, CN=0;
Add frame------------------------ADD FRM: FN=0, SN=0, PN=2, CF=YES;
HUAWEI TECHNOLOGIES CO., LTD. Page 67All rights reserved
Add WCSU board------------------------ADD BRD: FN=0, SN=0, LOC=FRONT, BT=WCSU, MN=22, ASS=1;
Add WEAM board------------------------ADD BRD: FN=0, SN=4, LOC=FRONT, BT=WEAM, MN=140, LNKT=LINK_2M;ADD BRD: FN=0, SN=5, LOC=FRONT, BT=WEAM, MN=141, LNKT=LINK_2M;
Example for hardware
HUAWEI TECHNOLOGIES CO., LTD. Page 68All rights reserved
Add WEPI board------------------------ADD BRD: FN=0, SN=0, LOC=BACK, BT=WEPI;ADD BRD: FN=0, SN=1, LOC=BACK, BT=WEPI;ADD BRD: FN=0, SN=4, LOC=BACK, BT=WEPI;ADD BRD: FN=0, SN=5, LOC=BACK, BT=WEPI;
Add WIFM board------------------------ADD BRD: FN=0, SN=10, LOC=FRONT, BT=WIFM, MN=132, ASS=11;
Example for hardware
HUAWEI TECHNOLOGIES CO., LTD. Page 69All rights reserved
Add WCCU board------------------------ADD BRD: FN=0, SN=2, LOC=FRONT, BT=WCCU, MN=23, ASS=3;
Add WBSG board------------------------ADD BRD: FN=0, SN=12, LOC=FRONT, BT=WBSG, MN=133;ADD BRD: FN=0, SN=13, LOC=FRONT, BT=WBSG, MN=134;
Example for hardware
HUAWEI TECHNOLOGIES CO., LTD. Page 70All rights reserved
Add WCKI board------------------------ADD BRD: FN=0, SN=13, LOC=BACK, BT=WCKI;ADD BRD: FN=0, SN=15, LOC=BACK, BT=WCKI;
Example for hardware
HUAWEI TECHNOLOGIES CO., LTD. Page 71All rights reserved
Example for hardware
3:Configure E1/CPC/FE/ATM data
Configure E1 info------------------------ADD EPICFG: FN=0, SN=0, LC=CLK_8KA, E0=CRC4, E1=DF, E2=DF, E3=DF, E4=DF, E5=DF, E6=DF, E7=DF, BM=BALANCE;
Configure CPC info------------------------MOD CPCCFG: FM=22, LOC=UPMC, LTYPE=LINK_64K;
HUAWEI TECHNOLOGIES CO., LTD. Page 72All rights reserved
Configure clock reference------------------------------SET CKICFG: CL=LEVEL2, WM=AUTO, B1P=L1, B2P=L2, L1P=L3, L2P=L4, B1CST=CLK_2M, B2CST=CLK_2M;
Configure clock from E1------------------------------ADD BOSRC: FN=0, SN=0, EN=2;
Example for hardware
Configure FE------------------------ADD FECFG: MN=132, IP="191.169.100.10", MSK="255.255.0.0", DGW="191.169.1.2";
HUAWEI TECHNOLOGIES CO., LTD. Page 73All rights reserved
Configure IMA link------------------------ADD IMAGRP: MN=140, IGN=0, IID=0, IVR=VER1.1;ADD IMALNK: MN=140, IGN=0, IPN=0;
Configure PVC link------------------------ADD PVCLNK: PLN=0, VPI=2, VCI=4, SDMN=140, SHMN=133, BT=IMA;
Example for hardware
HUAWEI TECHNOLOGIES CO., LTD. Page 74All rights reserved
Example for hardware
4: Set Local Office Data
Online------------------------SET OFI: OFN="HLR-TEST", LOT=CMPX, NN=YES, SN1=NAT, SN2=NAT, SN3=NAT, SN4=NAT, NPC=“EE00", NNS=SP14, STP=NO, LAC=K‘755, LNC=K‘86, LOCGT=“861380755", NETTYPE=GSM/PSTN;
HUAWEI TECHNOLOGIES CO., LTD. Page 75All rights reserved
Example for hardware
5: Format the data, load it
Online------------------------LON:;Turn on alarm switch------------------------SET CWSON: SWT=ON;Turn on format switch------------------------SET FMT: STS=ON;Format the data------------------------FMT:;Load the module one by one
HUAWEI TECHNOLOGIES CO., LTD. Page 76All rights reserved
Summary
After finish hardware data, trainees need
master the basic concepts of hardware.
Trainees need understand the steps of
SAU hardware data configuration
www.huawei.com
Thank You