Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Outstanding Thermal & Optical SystemRapid real-time PCR with IT connectivity and automated data analysis and result reporting
Rotor-Gene® Q+ Sentosa® SA Reporter
Outstanding Performance for Your Assays
Rotor-Gene® Q Instrument Features and Bene�ts
The Rotor-Gene® Q provides high thermal and optical uniformity, short equilibration times, and fast ramping rates which are critical for precise and rapid quantitative analysis. The Rotor-Gene® Q has a unique centrifugal rotary design that makes it a precise and versatile real-time PCR cycler. Vela Diagnostics’ proprietary Sentosa® SA Reporter software allows users to control thermal cycling protocols and perform automated data analysis, with connectivity to LIS.
Sentosa® SA Reporter Software
The Sentosa® SA Reporter converts the fluorescence signals from the Rotor-Gene® Q real-time PCR instrument to comparative quantitative readouts and generates automated reports.
Features
■ Rotary format with uniform detection■ Up to 72 samples per run for high-throughput runs■ Unmatched optical range spanning UV to infrared
wavelengths- highly suited for multiplex applications■ Ultra fast ramp rate ( Heating: >15°C/s , Cooling: >20°C/s)
for better turn-around time to support high-throughput ■ Well-to-well temperature variation below ±0.02°C to
ensure high accuracy and reproducibility■ No need for optical alignment, calibration, or lamp replacement■ Low maintenance and maximum convenience
■ Frees up tech resources and reduces turn-around time■ Ensures reproducible and reliable diagnostics■ Integrating seamlessly with laboratory procedures■ Customised E-Signatures for multiple users■ Automated result reporting with digital graphs
(Linear and Log Scale)■ Report generation in PDF or Excel formats
■ 21 validated sample types ■ 28 validated test assays (26 CE-IVD)■ Test combinations avaliable■ Clinically relevant test designs■ Sample to report in ~ 4 hours ■ Sample traceability throughout the workflow■ Highly automated workflow■ IT connectivity and LIS interfacing■ 1 service contract to cover entire workflow
Sentosa® PCR Work�ow Features and Bene�ts
Ordering Information
Equipment/ Software Item Number
Sentosa® SA Reporter 480132
Sentosa® SA Reporter Assay Package 480135
Rotor-Gene® Q MDx 5plex HRM Instrument 400046
Rotor-Disc 72 Starter Kit (230V) 400048
Real-Time PCR Work�ow
From sample extraction, PCR set up to automated result analysis and reporting
Rotor-Gene® QSentosa® SX101Samples Sentosa® SA Reporter
Axilla SwabCell Free DNA*Cerebral Spinal FluidFFPEGenital SwabGroin SwabLesion SwabNasal SwabNasopharyngeal SwabOral SwabPerianal SwabPlasmaRectal SwabSerumSputumStoolThroat SwabTotal RNA (Blood)UrineWhole BloodWound Swab
LysisExtractionPCR Set-UpPrimary Tube Handling(When applicable)
Strep AInfluenza A/B & RSVMTCH7N9#
Norovirus (GI & GII)SalmonellaC. Diff Rotavirus
HSV 1/2 QuantCMV QuantVZV QuantBKV QuantEBV QuantHHV6 Quant
NRASKRASBRAF (V600)
BCR-ABL (M)BCR-ABL (m)
Dengue (I-IV)Chikungunya
HBV Quant#
HCV Quant#
MRSA/SA (extraction)MRSA/SA DirectVRE (vanA/vanB)
Herpes Simplex Virus 1/2
Automated Data Analysis and Result Reporting
RespiratoryInfections
Gastroentritis
Immuno-suppression
Oncology
Leukemia
Tropical
BloodborneViruses
Microbiology
STD
*Early access avaliable#CE-IVD pending approval, RUO version available
IVD: For in-vitro diagnostic use. Not for distribution in US.Inclusive of all requisite licenses.
CIN
S-20
1607
07-B
R-A
P-EN
-002
-RG
QIV
D
: 37 cm (14.6 inches): 26.8 cm (11.3 inches): 42 cm (16.5 inches): 12.5 kg (27.6 lb)
Channels
Detector
Dynamic Range
OPTICAL SYSTEM
ELECTRICAL REQUIREMENTS
DIMENSIONS
THERMAL PERFORMANCE
: Up to 6 separate channels (365–680 nm excitation, 460–750 nm detection): Highly sensitive photomultiplier (PMT) detector with gain setting (sensitivity control) : 10 orders of magnitude (assay dependent)
WidthHeightDepthWeight
: 100 V to 240 V : 50 Hz to 60 Hz : 520 VA
VoltageFrequencyPower Consumption
: ± 0.02°C (Standard deviation): ± 0.5°C: ± 0.02°C: 35°C – 99°C: Heating: >15°C/s , Cooling: >20°C/s
Temperature UniformityTemperature AccuracyTemperature ResolutionTemperature RangeRamp Rate
CONFIGURATIONS
: 0.1 ml x 72 wellsRotor-Disc 72
TYPICAL RUN TIME
: Approximately 110 minutes (assay dependent)
Time Needed
For more information, kindly contact your Vela Diagnostics representative. All rights reserved. Vela is a trademark of Vela Diagnostics Holding Pte Ltd.
Sentosa® is a registered trademark of Vela Diagnostics Holding Pte Ltd in several markets including the US and the European Union.
Rotor-Gene® and Rotor Disc are registered trade names of QIAGEN GmbH.
Vela Operations Singapore Pte Ltd
Reg No: 201106974H
50 Science Park Road
#05-07 The Kendall
Singapore 117406
T: +65 6672 6060
T: 1800 225 8352 (Toll-Free)
F: +65 6672 6066
Vela Diagnostics Germany GmbH
Albert-Einstein-Ring 15
22761 Hamburg
Germany
T: +49 40 890 662233
F: +49 40 890 662299
Vela Diagnostics Australia Pty Ltd
PO Box 4045
North Curl Curl 2099 NSW
Australia
T: 1300 012 391
F: +61 2 9423 6970