12

OUTDOOR - Unical AG · PDF fileThe ESTRAL mechatronics ... The particularly small dimensions allow high project ... the automatic water filling will do all itself: in case of

  • Upload
    danganh

  • View
    212

  • Download
    0

Embed Size (px)

Citation preview

OUTDOORBOILER

Nominal output

max/min

KW

Input

max/min

kW

24 - 9,8Forced draughtAutomatic water filling

ESTRALCTFS 24 C.A. 26,5 - 11,1

Born for outdoor use

ESTRAL:safe both outsideand inside.Unical has developed and producedESTRAL, the last generation “outdoor”boiler, fixing some targets:• Conformity to the most restrictiveregulations

• Installation of great aesthetic result• Easy and essential controls andcommands

• Very high reliability on the most criticaloperation conditions

• Management of 2 different heatingzones.

ESTRAL has obtained the approval withthe Insulation Protection degree IP X5D,with very high waterproofing to directwater throws. It can operates also withextreme temperatures up to -15°C and+60°C. Very easy to use thanks to its easycontrols, that can be work also with 3different remote controls depending ofthe user’s need. Its configuration withsealed room and forced draught allowsits installation practically everywhere. It’sonly available in the combi version withinstantaneous DHW production of 13,4l/min with ∆t 25°K. ESTRAL can workwith natural gas or LPG and has a doubleelectronic ignition for total safety.

24 - 9,8Forced draughtManual water filling

ESTRALCTFS 24 C.M. 26,5 - 11,1

The ESTRAL mechatronics

Primary heat exchanger with lowdepth and high efficiency

Gas valve provided for outdooruse (down to -20°C)

Antifrost protection for high reliability3 solutions for the modulatingcontrol of the room temperature

12 ramps burner with high quitnessand reduced dimensions.Ignition with double electrode

Double NTC temperature sensorfor heating and sanitary circuits

Detail of 3 speeds pumpSingle hydraulic group, detail ofthe motorized diverting valve andsafety valve

Sanitary heat exchanger with16 plates INOX AISI 316 L

21 cm depth:really a record in its category!

Detail of flow switch for sanitarypriority and of the air relief device

Pump anti jamming timer

IMP

ULS

E

TIME (hours)16 h 32 h 48 h0 h

The pump, when the boilerremains in STAND BY positionfor more than 16 hours, receivesan impulse for 5 seconds by themicroprocessor, in order toavoid jamming.

thickness

A record

ESTRAL:the new reference point for theoutdoor boilersIt’s the most flat boiler in the market, with just 210mm of depth.Ideal, both for new installations and substitutions,ESTRAL allows to exploit at the best the space insidethe house.

ESTRAL is the best solution in order to have thecomplete agreement of engineers, users, aesthetesand practical persons.

The particularly small dimensions allow high projectflexibility and make easier the installation thanks tothe original fitting system.

• Depth: 210 mm• Height: 852 mm• Width: 510 mm

cm21

1 0987654321

c e n t i m e2

depth.

ESTRAL:practicality is a boilerfor “space saving”The needs that characterize the outdoor installationslet Unical studies to have a complete boilercomponents protection from corrosion caused,for chemical actions, from the atmospheric pollution,from salinity and atmosphere humidity(sea zones, weather variations).

The perfection of casing painted with epoxypolyesterpouders, its extraordinary waterproofing, the accurateattention on the details, the silent operation extablishthe future standard for “outdoor” boilers, placingit at the top for functionality and beauty.

A practical rubber waterproof top let ESTRAL beinstalled without not aesthetic outdoor protections.

1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 21

e t r e s1

cm21

ESTRAL: not only anoutdoor wall hung boiler

Technology of valueWith its compact and harmonious look,ESTRAL adds value to heating systemwhere it’s installed.

The possibility to realize different smokeand hydraulic configurations, like the 2zones management, solves and makeseasier the installer work.The perfect integration with the support

wall thank to its very reduced depth,makes of ESTRAL a valid aestheticsolution, with total respect ofarchitectonic contest.

The user will live its own home intotal quietness, feeling himselfpsychologically far from dangers fromfire and gas.

3 solutions for“controlling” ESTRAL

Unical target is to simplify the life of allowners of ESTRAL by introducing a newcollection of technological remote controls,in order to control the boiler with a fewoperations, everywhere it’s placed.

Always morerefined models• SIM-PLEXlike to have the boiler controls: DomesticHot Water temperature adjusting, CentralHeating temperature adjusting, boiler reset,water filling, lock-out led, leak of waterled.

• SIM-CRONOadds to the SIM-PLEX functions a weeklychronothermostat for the simplified settingof boiler ignition and switching off periodsand for the room temperature controlthanks to the integrated modulatingadjusting. This logic allows to reduce,modulating, the boiler output and thenconsumptions, by the simultaneouscomparison of two data: the boiler

temperature and the output required forthe room warming. In addition, adiagnostic system with 16 anomaliesshown with numeric codes is available,for a quicker technical intervention.

• TM 2000offers the SIM-CRONO features, but thanksto its wide display gives the informationin English and in other languages onadjusting, parameters setting anddiagnostics.

SIM-PLEX SIM-CRONO REGOLAFACILE

Lock out led

Indicates the burnersafety device intervention.

ON / OFF main switch Thermomanometer

Chimneysweeper button

Forces the boiler to work at maximum capacity, and thenand the minimum, in order to easily do the technical

gas valve adjusting and the combustion controls.

Reset push button

Allows to reset the boiler into operation after the lock out intervention.

Line led

Informs that the boiler is electrically supplied

Central Heating operation mode led

Informs a Central Heating request. It’s switched off ifthere is a simultaneous Domestic Hot Water request.

Burner led

Indicates the burner operation,both in Central Heating andDomestic Hot Water mode.

Control panelFor easy use, constitutes asingle vertical unit, that is apart of box containing theelectronics.

Vanguard components

Components accurancyFor ESTRAL the F.M.P. technology isused (Few Moving Parts), to guaranteehigh reliability. The engineeringstudies have obtained a precious target:the extraordinary dimensions.The depth of only 21 cm set ESTRALat the top of the flat boilers, thank to:

• Monothermic primary heat exchangerwith special threated connections and adepth of only 145 mm: it guarantees allthe necessary capacity and the idealefficiency both at 24 and at 8,9 kW (max.and min).

• DHW 16 plates inox AISI 316 L heat exchangerIt’s mounted a sanitary heat exchangerwith 16 plates in stainless steel AISI 316L, in order to rationally use the availablespace. It’s oversized of 25% incomparison to the boiler output. Thischoice gives an higher exchange surfaceso, with the same water temperatureand needed quantities, it’s possible tolet the boiler work with lowertemperatures obtaining:

• Reduction of limestone depositphenomena

• More instantaneous Domestic Hot Waterwarming

• Constant water temperature during thedrawings

• DHW production of 13,4 l/min with ∆t 25°K.

• Motorized diverting valve Of new conception, result of Unicaltechnologic study, it’s part of a brasshydraulic group very compact and,thanks to the powerful electric motor,allows quickly and safely to divert thehot water produced by the primary heatexchange to the sanitary heat exchangeror in loop to the heating circuit,

DIAGRAM FLOW RATE / MANOMETRIC HEAD

optimizing the operation in temperaturemodulation with the special modulatingremote controls.

• The automatic by-pass allows to optimize the water circulationinto the boiler, avoiding in this wayoverheatings.

Man

omet

ric h

ead

H (m

)

Pump flow rate Q (l/h)

0

6,0

5,0

4,0

3,0

2,0

1,0

100 300 500 700 900 1100

V3V2

V1

NEW HYDRAULIC COMPACT ENBLOCK

By pass CLOSEDBy pass OPEN

High performancesin small spaces

C - DHW outlet

G - Gas inlet

F - Cold water inlet

M - CH system flow

R - Return from CH system

VD - Electric diverting valve

ESTRAL functions includedthe pump overrun antioverheating and the automaticdetection of 15 anomaliesvisible on the display of TM2000 and SIM-CRONO in orderto quickly do the technicalinterventions.

Furthermore the connectionof a second ON/OFFthermostat allows thetemperature managementof a second zone.

• total accessibilityto guarantee a rational disposition,immediate and simple for every technicalintervention for regulation, control ormaintenance.

Automatic or manualwater filling…The manual filling and drain valves allowrapid interventions, and the connectionsand interventions are simplified thanks tovertically sliding control panel.For more exigent demands, the automaticwater filling will do all itself: in case of“low pressure” signal, the boiler software,that continuously controls the systempressure, will provide to fill in the water.If this filling up will be not enough, thealarm led will inform the user of a possibleheating system or boiler water leakage.

The combustion chamber is frontallyaccessible, so as the burner, the heatexchanger and the fan.

The combustion adjusting are also reallyrapid thanks to the provided forchimneysweeper function.

The electronic management bymicroprocessor controls constantly all

The UNICAL components technology isthe result of an accurate analysis realizedmostly on three ways:

• qualitativeto guarantee in every weather conditionoperation reliability and high performances;

• dimensionalassuring a very reduced total depth thatallows the installation everywhere and inharmoniously;

PRIMARY HEAT EXCHANGER

ESTRAL HYDRAULIC CIRCUIT

Cod. 00360568

Full of accessories and reliable

VALVES KIT (OPTIONAL)

TYPE B22 VERTICAL AIR SUCTION / SMOKE OUTLETØ 80 DOUBLE KIT

HORIZONTAL COAXIAL CONNECTION Ø 60/100

Cod. KIT5500C

Cod. SER 0100C

Cod. TSC0620C

VERTICAL COAXIAL CONNECTION Ø 60/100

Cod. 00361089

Cod. TSC0210C

KIT A (COAXIAL Ø 60/100)

Cod. 00360350

AIR SUCTION / SMOKE OUTLET Ø 80 DOUBLE KIT

RESISTORS KIT FOR LOW TEMPERATURES (OPTIONAL)

95

95

90°

120

TYPE B 22

KIT A

An “elevated service content” to savetime and money is what ESTRALoffers to the installers and the user.The installation is quick withoutdoubts. A metallic wall template isdelivered for the rapid positioning.Smoke ducts for the differentconfigurations both outdoor (B23)or indoor (C) and the completeavailable catalogue, with the high fanpressure head, will allow to solveevery situation.

ESTRAL allows the M 3000 installation,an electro-hydraulic device for thesimultaneous management of hightemperature circuits (radiators) andlow temperature installations (floorheating systems).

Cod

. 290

25G

B E

d. 1

- 5

/05

CTFS 24

Boiler installation

Model

kW

kW

%

%

°C

bar

bar

l/min

V/Hz

W

IP

kg

Technical data Dimensions

24 / 9,8

26,5 / 11,1

90,48

87,81

113

II2H3P

0,5/3

0,5/6

13,4

230 / 50

119

X5D

33,5

METALLIC TEMPLATE (delivered with the boiler)

3

21

4

Smoke outlet installation Hydraulic and electric connections

Boiler casing closing Rubber top installation

SVS RS

M C G F R

RC

100,

5

81 105

210

132

158,5 72,5 57,5 79 65 83

32

5

15

127 222

33

ø6

ø12 ø12

806,

5

816,

5 (o

ptio

nal)

V P RGC

2

ø90 ø90 ø90

ø110

82 82

70 55

137

152

247

NOMINAL OUTPUT max / min

INPUT max / min

EFFICIENCY at full load 100%

EFFICIENCY at part load 30%

MAX SMOKE TEMPERATURE

APPLIANCE CATEGORY

HEATING SYSTEM PRESSURE min / max

SANITARY CIRCUIT PRESSURE min / max

DHW PRODUCTION in continuous with •f0 t 25K

ELECTRICAL SUPPLY Voltage / Frequency

MAX ABSORBED POWER

INSULATION PROTECTION DEGREE

NET WEIGHT

Unical AG declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves the right to introduce thosemodifications to its products that it considers necessary or useful, without compromising the essential characteristics of the said products.