28
Outdoor Air Processing Unit FXMQ-MFVJU EDUS39-900B-F10 202103 Engineering Data 60 Hz

Outdoor Air Processing Unit - Daikin Comfort

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Outdoor Air Processing Unit - Daikin Comfort

Outdoor Air Processing UnitFXMQ-MFVJU

EDUS39-900B-F10202103

Engineering Data

60 Hz

Page 2: Outdoor Air Processing Unit - Daikin Comfort
Page 3: Outdoor Air Processing Unit - Daikin Comfort

1

FXMQ-MFVJU EDUS39-900B-F10

Table of Contents

1. FeaturesandBenefits ................................................................................22. Specifications .............................................................................................33. Dimensions .................................................................................................54. CenterofGravity ........................................................................................75. Piping Diagrams .........................................................................................86. Wiring Diagrams .........................................................................................97. Electric Characteristics ............................................................................. 118. CapacityTables ........................................................................................129. OperationLimit .........................................................................................1510.FanPerformances ....................................................................................1811.SoundLevels(ReferenceData) ...............................................................21

11.1 Overall .............................................................................................2111.2 OctaveBandLevel ..........................................................................22

12.Accessories ..............................................................................................2312.1OptionalAccessories(forUnit) .......................................................23

Page 4: Outdoor Air Processing Unit - Daikin Comfort

2

FXMQ-MFVJU EDUS39-900B-F10

1. Features and Benefits

Concealed, Powerful, Fresh Air IntegrationThe100%outsideairprocessingunitprovidesazoned,decentralizedapproachtoconditioningoutsideair.Thishelpstoreduceductworkandinstallationtimewhileincreasingefficiencyandflexibility.Bothoutsideairtreatmentandspaceconditioningcanbeprovidedfromonecompact,flexible,andefficientVRVsystem.VRVindoorunitsandoutdoorairprocessingunitcanbeconnectedtothesamerefrigerantline,enablingenhanceddesignflexibility.

� Designflexibilitywithacapacityrangeupto96MBH � Thenominalairflowratesare635,988,and1,236CFM � ImprovedductworkandfiltrationflexibilitywithESPcapabilityofupto1.03”W.G � Lowprofiledesignoflessthan19”hightoreducerequiredinstallationspace � IndoorAirQualityoptionsincludeMERV8and13filtersandfilterboxes � SeamlesslyintegrateswithNorthAmericanDaikinVRVsystemsandcontrollers

Outside air processing unit VRV outdoor unit

for outside air supply

VRV indoor unit

for air-conditioning

Page 5: Outdoor Air Processing Unit - Daikin Comfort

3

FXMQ-MFVJU EDUS39-900B-F10

2. Specifications

Model FXMQ48MFVJU FXMQ72MFVJUPowersupply 1phase,60Hz,208/230V 1phase,60Hz,208/230VH1,H3Coolingcapacity Btu/h 48,000 72,000H2,H3Heatingcapacity Btu/h 30,000 47,000Casing/Color Galvanizedsteelplate GalvanizedsteelplateDimensions:(H×W×D) in. 18-1/2×29-1/4×43-5/16 18-1/2×54-3/8×43-5/16Coil(crossfincoil)

Rows×Stages×Finpitch 3×26×13 3×26×13Face area ft² 3.01 7.00

Fan

Model D13/4G2DA1 D13/4G2DA1Type Siroccofan SiroccofanMotoroutput×Numberofunits W 380×1 380×1

Airflowrate cfm 635 988Externalstaticpressure in.H2O 0.88 0.96

Drive Directdrive DirectdriveTemperaturecontrol Microprocessorthermostatforcoolingandheating MicroprocessorthermostatforcoolingandheatingSoundabsorbingthermalinsulationmaterial Glassfiber Glassfiber

Airfilter H4 H4H6Soundpressurelevel(referencedata) dBA 43 48

Weight lbs 190 271

Piping connections

Liquidpipes in. ɸ3/8(flareconnection) ɸ3/8(flareconnection)Gaspipes in. ɸ5/8(flareconnection) ɸ3/4(brazingconnection)Drain pipe in. PS1B PS1B

Safetydevices Fuse,Thermalprotectorforfanmotor Fuse,ThermalprotectorforfanmotorRefrigerantcontrol Electronicexpansionvalve ElectronicexpansionvalveH5Connectableoutdoorunits R410AVRV series R410AVRV series

Standardaccessories Operationmanual,Installationmanual,Sealingpads,Screws,Clamps

Operationmanual,Installationmanual,Sealingpads,Screws,Clamps,Connectionpipes

Note:H1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:

Outdoortemperature:91°FDB,82°FWB(68%RH) Dischargesettemperature:64°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

H2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Outdoortemperature:32°FDB,27°FWB(50%RH) Dischargesettemperature:77°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

H3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.H4. Airfilterisnotstandardaccessory,butpleasemountitintheductsystemofthesuctionside.

Selectitsductcollectionefficiency(gravitymethod)50%ormore.H5. Withintherangethatthetotalcapacityofindoorunitsis50to100%,itispossibletoconnecttotheoutdoorunit.H6. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,thesevaluesmaybehigherasaresultof

installationconditions.

C:3D065463

Page 6: Outdoor Air Processing Unit - Daikin Comfort

4

FXMQ-MFVJU EDUS39-900B-F10

Model FXMQ96MFVJUPowersupply 1phase,60Hz,208/230VH1,H3Coolingcapacity Btu/h 96,000H2,H3Heatingcapacity Btu/h 59,000Casing/Color GalvanizedsteelplateDimensions:(H×W×D) in. 18-1/2×54-3/8×43-5/16Coil(crossfincoil)

Rows×Stages×Finpitch 3×26×13Face area ft² 7.00

Fan

Model D13/4G2DA1Type SiroccofanMotoroutput×Numberofunits W 380×1

Airflowrate cfm 1,235Externalstaticpressure in.H2O 1.03

Drive DirectdriveTemperaturecontrol MicroprocessorthermostatforcoolingandheatingSoundabsorbingthermalinsulationmaterial Glassfiber

Airfilter H4H6Soundpressurelevel(referencedata) dBA 48

Weight lbs 271

Piping connections

Liquidpipes in. ɸ3/8(flareconnection)Gaspipes in. ɸ7/8(brazingconnection)Drain pipe in. PS1B

Safetydevices Fuse,ThermalprotectorforfanmotorRefrigerantcontrol ElectronicexpansionvalveH5Connectableoutdoorunits R410AVRV seriesStandardaccessories Operationmanual,Installationmanual,Sealingpads,Screws,Clamps,Connectionpipes

Note:H1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:

Outdoortemperature:91°FDB,82°FWB(68%RH) Dischargesettemperature:64°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

H2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Outdoortemperature:32°FDB,27°FWB(50%RH) Dischargesettemperature:77°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

H3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.H4. Airfilterisnotstandardaccessory,butpleasemountitintheductsystemofthesuctionside.

Selectitsductcollectionefficiency(gravitymethod)50%ormore.H5. Withintherangethatthetotalcapacityofindoorunitsis50to100%,itispossibletoconnecttotheoutdoorunit.H6. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,thesevaluesmaybehigherasaresultof

installationconditions.

C:3D065463

Page 7: Outdoor Air Processing Unit - Daikin Comfort

5

FXMQ-MFVJU EDUS39-900B-F10

3. Dimensions

FXMQ48MFVJU

3D06

5452

A

Uni

t: in

.

Page 8: Outdoor Air Processing Unit - Daikin Comfort

6

FXMQ-MFVJU EDUS39-900B-F10

FXMQ72-96MFVJU

3D06

5453

A

Uni

t: in

.

Page 9: Outdoor Air Processing Unit - Daikin Comfort

7

FXMQ-MFVJU EDUS39-900B-F10

4. Center of Gravity

FXMQ48-96MFVJU

Unit: in.

4D065444

Model

FXMQ48MFVJU

FXMQ72MFVJU

FXMQ96MFVJU

ProductMass

190Lbs

271Lbs

271Lbs

AA

30-11/16

54-5/16

54-9/16

AB

27-3/8

51

51

AC

23-5/8

22-7/16

22-7/16

AD

9-13/16

9-13/16

9-13/16

AE

13

23-5/8

23-5/8

Page 10: Outdoor Air Processing Unit - Daikin Comfort

8

FXMQ-MFVJU EDUS39-900B-F10

5. Piping Diagrams

FXMQ48-96MFVJU

Unit:in.Model Gas Liquid

FXMQ48MFVJU ɸ5/8ɸ3/8FXMQ72MFVJU ɸ3/4

FXMQ96MFVJU ɸ7/8

4D018650D

Page 11: Outdoor Air Processing Unit - Daikin Comfort

9

FXMQ-MFVJU EDUS39-900B-F10

6. Wiring Diagrams

FXMQ48-96MFVJU

C: 3

D06

5426

D

NO

TES)

1.

: T

ERM

INAL

BLO

CK,

,

: C

ON

NEC

TOR

,

:

TER

MIN

AL,

: S

HO

RT

CIR

CU

IT C

ON

NEC

TOR

,

: FIE

LD W

IRIN

G.

2. IN

CAS

E U

SIN

G C

ENTR

AL R

EMO

TE C

ON

TRO

LLER

, CO

NN

ECT

IT T

O T

HE

UN

IT IN

AC

CO

RD

ANC

E W

ITH

TH

E AT

TAC

HED

INST

RU

CTI

ON

MAN

UAL

.3.

IN C

ASE

CO

NN

ECTI

NG

TH

E IN

PUT

WIR

ES F

RO

M O

UTS

IDE,

FO

RC

ED O

FF O

R O

N/O

FF C

ON

TRO

L O

PER

ATIO

N C

AN B

E SE

LEC

TED

BY

REM

OTE

CO

NTR

OLL

ER.

IN

DET

AILS

, REF

ER T

O T

HE

INST

ALLA

TIO

N M

ANU

AL A

TTAC

HED

TO

TH

E U

NIT

.4.

DO

NO

T R

EMO

VE S

HO

RT

CIR

CU

IT C

ON

NEC

TOR

OF

X9A.

5. S

YMBO

LS S

HO

W A

S FO

LLO

WS:

RED

: RED

BLK

: BLA

CK

WH

T: W

HIT

E Y

LW: Y

ELLO

W P

PL: P

UR

PLE

GR

Y: G

RAY

BLU

: BLU

E P

NK:

PIN

K O

RG

: OR

ANG

E

GR

N: G

REE

N

6. C

LASS

2 W

IRE

Page 12: Outdoor Air Processing Unit - Daikin Comfort

10

FXMQ-MFVJU EDUS39-900B-F10

FXMQ48-96MFVJU

ELECTRICALCOMPONENTSANDWIRINGCONNECTORSFORINDOORUNITA1P PRINTEDCIRCUITBOARDC1·C2 CAPACITOR(M1F)F1U FUSE( B ,5A,250V)(A1P)HAP LIGHTEMITTINGDIODE(SERVICEMONITOR-GREEN)K1M MAGNETICRELAY(M1F)K1R MAGNETICRELAY(M1F)KPR MAGNETICRELAY(M1P)KSR MAGNETICRELAY(Y1S)M1F MOTOR(FAN)Q1M THERMALPROTECTOR(M1FEMBEDDED135°C)R1T THERMISTOR(SUCTIONAIR)R2T THERMISTOR(COIL,LIQUID)R3T THERMISTOR(COIL,GAS)R4T THERMISTOR(DISCHARGEAIR)T1R TRANSFORMAR(208V/230V25VA)X1M TERMINALBLOCK(POWER)X2M TERMINALBLOCK(CONTROL)X3M TERMINALBLOCKX51A,X52A CONNECTORY1E ELECTRICEXPANSIONVALVEY1S SOLENOIDVALVE(HOTGAS)CONNECTORFOROPTIONALPARTSX18A CONNECTOR(WIRINGADAPTORFORELECTRICALAPPENDICES)

C:3D065426D

Page 13: Outdoor Air Processing Unit - Daikin Comfort

11

FXMQ-MFVJU EDUS39-900B-F10

7. Electric Characteristics

FXMQ48-96MFVJU

ModelPowersupply IFM Input(W)

SCCRHz Volts Voltagerange MCA MOP KW FLA Cooling Heating

FXMQ48MFVJU60 208/230V Max.253V

Min.187V

2.1 15 0.380 1.7 359 359 SCCRkArms,Symmetrical

@600VMAX:5FXMQ72MFVJU 3.6 15 0.380 2.9 548 548FXMQ96MFVJU 4.1 15 0.380 3.3 638 638

Symbol:MCA: Min.CircuitAmps(A)MOP: Max.OvercurrentProtectiveDevice(A)KW: FanMotorRatedOutput(kW)FLA: FullLoadAmps(A)IFM: IndoorFanMotorSCCR:Short-CircuitCurrentRating

Note:1.Voltagerange Unitsaresuitableforuseonelectricalsystemswherevoltagesuppliedtounitterminalsisnotbeloworabovelistedrangelimits.

2.Maximumallowablevoltageunbalancebetweenphaseis2%.3.MCA/MOP MCA=1.25×FLA MOP≤4×FLA (Nextlowerstandardfuseraring.Min.15A)

4.SelectwiresizebasedontheMCA.

C:4D065596

Page 14: Outdoor Air Processing Unit - Daikin Comfort

12

FXMQ-MFVJU EDUS39-900B-F10

8. Capacity Tables

FXMQ48MFVJU

Cooling

Outdoorairtemperature °FWB

°FDB62 66 70 74 78 82 86 90

CapacityMBh MBh MBh MBh MBh MBh MBh MBh

67 13000 1590071 13000 15900 1830075 13000 15900 18300 2330079 15900 18300 2290083 18300 22900 3770087 17900 22600 37300 4830091 17900 22200 37000 48000 5620095 21900 36600 47600 55800 59600

Heating

Outdoorairtemperature °FWB

°FDB19 23 27 31 35 39 43 51 55

CapacityMBh MBh MBh MBh MBh MBh MBh MBh MBh

22 32600 32600 - - - - - - -32 - - 30000 - - - - - -37 - - 26600 26600 26600 - - - -42 - - - - 21500 21500 21500 - -52 - - - - - 16800 16800 16800 -57 - - - - - - 12100 12100 12100

Note:1.Theabovecapacitiesarebasedonthefollowingconditions: Airdischargetemperaturesetting:64°Fforcoolingoperation, 77°Fforheating(factorysetting). Equivalentpipinglength:25ft. Leveldifference:0ft.2.Theabovecapacitiesvaluesaregeneralaveragevalueswhichcanbegeneratedbyeachcompressoroperationlevel.3.Avalueenclosedin meansratedcapacity.

Page 15: Outdoor Air Processing Unit - Daikin Comfort

13

FXMQ-MFVJU EDUS39-900B-F10

FXMQ72MFVJU

Cooling

Outdoorairtemperature °FWB

°FDB62 66 70 74 78 82 86 90

CapacityMBh MBh MBh MBh MBh MBh MBh MBh

67 19600 24000 - - - - - -71 19600 24000 27600 - - - - -75 19600 24000 27600 34700 - - - -79 - 24000 27300 34400 - - - -83 - - 27300 34000 56500 - - -87 - - 27000 33700 55900 72600 - -91 - - 27000 33100 55600 72000 84200 -95 - - - 32700 54900 71300 83800 89300

Heating

Outdoorairtemperature °FWB

°FDB19 23 27 31 35 39 43 51 55

CapacityMBh MBh MBh MBh MBh MBh MBh MBh MBh

22 50700 50700 - - - - - - -32 - - 47000 - - - - - -37 - - 41200 41200 41200 - - - -42 - - - - 33800 33800 33800 - -52 - - - - - 26300 26300 26300 -57 - - - - - - 18900 18900 18900

Note:1.Theabovecapacitiesarebasedonthefollowingconditions: Airdischargetemperaturesetting:64°Fforcoolingoperation, 77°Fforheating(factorysetting). Equivalentpipinglength:25ft. Leveldifference:0ft.2.Theabovecapacitiesvaluesaregeneralaveragevalueswhichcanbegeneratedbyeachcompressoroperationlevel.3.Avalueenclosedin meansratedcapacity.

Page 16: Outdoor Air Processing Unit - Daikin Comfort

14

FXMQ-MFVJU EDUS39-900B-F10

FXMQ96MFVJU

Cooling

Outdoorairtemperature °FWB

°FDB62 66 70 74 78 82 86 90

CapacityMBh MBh MBh MBh MBh MBh MBh MBh

67 26000 3180071 26000 31800 3670075 26000 31800 36700 4620079 31800 36300 4590083 36300 45600 7540087 36000 44900 74700 9660091 36000 44200 74000 96000 11240095 43800 73300 95300 111700 119300

Heating

Outdoorairtemperature °FWB

°FDB19 23 27 31 35 39 43 51 55

CapacityMBh MBh MBh MBh MBh MBh MBh MBh MBh

22 63700 63700

32 59000

37 51800 51800 51800

42 42300 42300 42300

52 33200 33200 33200

57 23700 23700 23700

Note:1.Theabovecapacitiesarebasedonthefollowingconditions: Airdischargetemperaturesetting:64°Fforcoolingoperation, 77°Fforheating(factorysetting). Equivalentpipinglength:25ft. Leveldifference:0ft.2.Theabovecapacitiesvaluesaregeneralaveragevalueswhichcanbegeneratedbyeachcompressoroperationlevel.3.Avalueenclosedin meansratedcapacity.

Page 17: Outdoor Air Processing Unit - Daikin Comfort

15

FXMQ-MFVJU EDUS39-900B-F10

9. Operation Limit

FXMQ48MFVJU

C: 3

D04

6312

Ope

ratio

nlim

it(c

oolin

g)

Ope

ratio

n lim

it(h

eatin

g)

Fan o

nlyop

erati

on

Outdoor air te

mp. (°F WB)

Out

door

air

tem

p. (°

F D

B)23

3242

.859

66.2

84.2

(92.

3)10

6.7

109.

4

2)

:The

dis

char

ge a

ir te

mpe

ratu

re

may

not

mat

ch th

e te

mpe

ratu

re

setti

ng fo

r too

larg

e ou

tdoo

r-air

proc

essi

ng c

apac

ity.

Ther

mos

tat O

FF m

ay b

e ca

rried

out

.

NO

TE1)

The

se fi

gure

s as

sum

e th

e fo

llow

ing

oper

atin

g co

nditi

ons.

(Indo

or a

nd o

utdo

or u

nits

)Eq

uiva

lent

pip

e le

ngth

: 25

ft.Le

vel d

iffer

ence

: 0 ft

.

3)

:

The

dis

char

ge a

ir te

mpe

ratu

re

may

not

mat

ch th

e te

mpe

ratu

re

setti

ng fo

r too

sm

all o

utdo

or-a

ir pr

oces

sing

cap

acity

.

4) T

he s

yste

m w

ill no

t ope

rate

in fa

n m

ode

whe

n th

e ou

tdoo

r-air

tem

pera

ture

is 4

1°F

or b

elow

.

89.6

Page 18: Outdoor Air Processing Unit - Daikin Comfort

16

FXMQ-MFVJU EDUS39-900B-F10

FXMQ72MFVJU

C: 3

D04

7750

Ope

ratio

nlim

it(c

oolin

g)

Ope

ratio

n lim

it(h

eatin

g)

Fan

only

oper

atio

n

Outdoor air te

mp. (°F WB)

Out

door

air

tem

p. (°

F D

B)23

3259

66.2

86(9

2.3)

106.

710

9.4

2)

:The

dis

char

ge a

ir te

mpe

ratu

re

may

not

mat

ch th

e te

mpe

ratu

re

setti

ng fo

r too

larg

e ou

tdoo

r-air

proc

essi

ng c

apac

ity.

Ther

mos

tat O

FF m

ay b

e ca

rried

out

.

NO

TE1)

The

se fi

gure

s as

sum

e th

e fo

llow

ing

oper

atin

g co

nditi

ons.

(Indo

or a

nd o

utdo

or u

nits

)Eq

uiva

lent

pip

e le

ngth

: 25

ft.Le

vel d

iffer

ence

: 0 ft

.

3)

:

The

dis

char

ge a

ir te

mpe

ratu

re

may

not

mat

ch th

e te

mpe

ratu

re

setti

ng fo

r too

sm

all o

utdo

or-a

ir pr

oces

sing

cap

acity

.

4) T

he s

yste

m w

ill no

t ope

rate

in fa

n m

ode

whe

n th

e ou

tdoo

r-air

tem

pera

ture

is 4

1°F

or b

elow

.

89.6

Page 19: Outdoor Air Processing Unit - Daikin Comfort

17

FXMQ-MFVJU EDUS39-900B-F10

FXMQ96MFVJU

C: 3

D04

6313

Ope

ratio

nlim

it(c

oolin

g)

Ope

ratio

n lim

it(h

eatin

g)

Fan

only

oper

atio

nOutdoor a

ir temp. (°

F WB)

Out

door

air

tem

p. (°

F D

B)23

3259

66.2

84.2

(92.

3)10

6.7

109.

42)

:The

dis

char

ge a

ir te

mpe

ratu

re

may

not

mat

ch th

e te

mpe

ratu

re

setti

ng fo

r too

larg

e ou

tdoo

r-air

proc

essi

ng c

apac

ity.

Ther

mos

tat O

FF m

ay b

e ca

rried

out

.

NO

TE1)

The

se fi

gure

s as

sum

e th

e fo

llow

ing

oper

atin

g co

nditi

ons.

(Indo

or a

nd o

utdo

or u

nits

)Eq

uiva

lent

pip

e le

ngth

: 25

ft.Le

vel d

iffer

ence

: 0 ft

.

3)

:

The

dis

char

ge a

ir te

mpe

ratu

re

may

not

mat

ch th

e te

mpe

ratu

re

setti

ng fo

r too

sm

all o

utdo

or-a

ir pr

oces

sing

cap

acity

.

4) T

he s

yste

m w

ill no

t ope

rate

in

fan

mod

e w

hen

the

outd

oor-a

ir te

mpe

ratu

re is

41

°F o

r bel

ow.

89.6

Page 20: Outdoor Air Processing Unit - Daikin Comfort

18

FXMQ-MFVJU EDUS39-900B-F10

10. Fan Performances

FXMQ48MFVJU

3D06

5649

B

Page 21: Outdoor Air Processing Unit - Daikin Comfort

19

FXMQ-MFVJU EDUS39-900B-F10

FXMQ72MFVJU

3D06

5650

B

Page 22: Outdoor Air Processing Unit - Daikin Comfort

20

FXMQ-MFVJU EDUS39-900B-F10

FXMQ96MFVJU

3D06

5651

B

Page 23: Outdoor Air Processing Unit - Daikin Comfort

21

FXMQ-MFVJU EDUS39-900B-F10

11. Sound Levels (Reference Data)11.1 Overall

n Location of microphone

6.6 ft4.

9 ft

DUCTDISCHARGE SUCTION

MICROPHONE

DUCT

3.3 ft

Note:1.Operationnoisedifferswithoperationandambientconditions.

dBAModel 208/230V,60Hz

FXMQ48MFVJU 43FXMQ72MFVJU 48FXMQ96MFVJU 48

Page 24: Outdoor Air Processing Unit - Daikin Comfort

22

FXMQ-MFVJU EDUS39-900B-F10

11.2 Octave Band Level

208/230V,60Hz

FXMQ48MFVJU FXMQ72MFVJU

C: 4D068575 C: 4D068576

FXMQ96MFVJU

C: 4D068577

Page 25: Outdoor Air Processing Unit - Daikin Comfort

23

FXMQ-MFVJU EDUS39-900B-F10

12. Accessories12.1 Optional Accessories (for Unit)

Option FXMQ48MFVJU FXMQ72MFVJU FXMQ96MFVJUDrainpumpkit KDU30L250VE

Highefficiencyfilter65% KAF372M140 KAF372M28090% KAF373M140 KAF373M280

FilterchamberH1 KDJ3705L140 KDJ3705L280Longlifereplacementfilter KAF371M140 KAF371M280

C:3D065445Note:H1.Filterchamberhasasuction-typeflange.(Mainunitdoesnothave.) ·Dimensionsandweightoftheequipmentmayvarydependingontheoptionsused. ·Someoptionsmaynotbeusableduetotheequipmentinstallationconditions,sopleaseconfirmpriortoordering. ·Someoptionsmaynotbeusedincombination. ·Operatingsoundmayincreasesomewhatdependingontheoptionsused.

Page 26: Outdoor Air Processing Unit - Daikin Comfort
Page 27: Outdoor Air Processing Unit - Daikin Comfort
Page 28: Outdoor Air Processing Unit - Daikin Comfort

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

Read the user’s manual carefully before using this product. The user’s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any inquiries, please contact your local importer, distributor and/or retailer.

©All rights reserved 03/21 FS

●Specifications, designs and other content appearing in this brochure are current as of March 2021 but subject to change without notice.