12
Our Heaters for your Projects PRODUCT IN FOCUS HEAT TRACING SYSTEMS HEATERS SURFACE HEATING SYSTEMS BOILERS

Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

Our Heaters for your Projects

P R O D U C T I N F O C U S

H E at t r a c i n G sYs t E M s H E at E r s s U r Fa c E H E at i n G sYs t E M s b O i l E r s

Page 2: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

Quality right from the Start

The specialists for electric heating systems

For the worldwide use of our products and services we

are fulfilling the high quality demands and expectations

of our customers from design up to commissioning. Not

only to keep these demands but to develop them conti-

nuously to the benefit of our customers. This is reached

by our integrated management system and the clearly

defined company. Each of our employees is involved in

the management system and is responsible for the quality

of our products and services.

2

Electric HeatersElectric heaters are used for direct (rarely) indirect heating

or temperature maintenance (compensation of heat losses),

vaporization and melting of solid, liquid and gaseous media.

ThE SySTEm aT a GlancE

Page 3: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

Electric HeatersElectric heaters are used for direct (rarely) indirect heating

or temperature maintenance (compensation of heat losses),

vaporization and melting of solid, liquid and gaseous media.

ThE SySTEm aT a GlancE

E l E c t r i c H E at E r s

H E at E r s 3

Our scope of supply

it passes from heating inserts up to the complete unit for the installation in the ex-threatened area.

All our electrical heating systems are tailored to your needs. These include complementary components like condensate, collective container and balance container, water treatment, pump as well as armatures belong to it. The power supply is steered by a switch arrangement and control.

Our Management systemIECEx Quality Assessment ReportQuality Management System according to DIN EN ISO 9001Safety Management according to SCC**-CatalogueEx-Directive 94/9/EC (ATEX)Pressure Equipment Directive according to DgRI 97/23/ECAD 2000 HP0ASME U-Stamp

Page 4: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

4

application

The Application Range

for heating inserts and heaters include among others the chemical, petrochemical, pharmaceutical, steel, textile, cellulose, oil and gas industries as well as power stations and refineries.

The Erection

can take place both, in non-explosive and explosion-endangered areas of zones 1 and 2 in the presence of gases and vapors of groups IIa, IIB and IIc. For use in explosion-endangered areas, the standard heating insert is delivered with a connection box in “flameproof enclosure”, design Ex d, if required, with additional connection boxes “increased safety” Ex e or Ex i “intrinsically safty”, including Ec type examination certifica-te/Ec declaration of conformity certificate, thereby the electrical part is separated from the instrumentation part. To keep the temperature class defined by the operator for the place operation by cooling sections and additional thermal protection measures are part of our design and have to be verified at site.

The Design for an electric heater depends on the temperature required, the pressure and the connection power. The material is selected according to the medium to be heated, the temperature and pressure. materials such as carbon steel, stainless and heat resistant steels, nickel-based alloys, titanium and other surface-coated special materials are used.

The limits of application need to be verified in each individual case. The following operating and design conditions have already been proved to be feasible: > temperatures up to 650°C, with special constructions up to 850°C> pressures up to 250 bar> power inputs of up to 10.000 kW can be reached in one unit so far, however not presenting our maximum power limit> connection voltages up to 690 V,

in special cases up to 1200 V

Page 5: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

application

a p p l i c at i O n | c O n s t r U c t i O n

H E at E r s 5

> cylindrical shell (flow pipe) with nozzles for medium inlet and outlet and, as required, with nozzles for drain, ventilation, safety valve etc.> heating insert (tube bundle) with electric heating elements (the medium inside the pipe is replaced by electric energy)> girth flange for fixing the heating insert

> temperature sensor (limiter) for measuring the heating surface temperature> temperature sensor (controller) for measuring the medium temperature> supports for horizontal or vertical erection> wiring room (pre-chamber) of heating insert> connection box for temperature sensors

construction

An electric heater is comparable with a conventional tube bundle heat exchanger and consists of the following components:

The medium is heated during the flow. The flow is di-rected in one or several ways, transversely or longitu-dinally, depending on the medium and the operating conditions. The maximum temperature permitted on the heating surface (specified by the medium to be heated and the material selection) and the pressure loss permitted need to be taken into consideration.

The temperature of heating surface is monitored by at least two temperature sensors (thermocouple, PT100, thermostat), functioning as limiters. as soon as the temperature permitted is reached, the total power of the heater is switched off. A restart can only be effected after having clarified the reason for cut-off.

Page 6: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

6

Different types of heating elements are used for the transmission of heat, such as hairpin heating elements and ceramic heating elements.

Hairpin heating elements

The standard hairpin heating elements consist of a metal jacket pipe with a diameter of 8.5 to 16 mm, bended U-shaped. The heating wire is located in the centre of the pipe, embedded in highly compressed magnesium oxide. This guarantees an excellent isolation resistance and a perfect heat conductivity between heating conductor and jacket pipe. The elements are installed into the tube sheet of heating insert by brazing, welding or screw connections. The hairpin heating elements are mainly used for heating up gases and liquids.

Ceramic Heating Elements

mainly consist of ceramic parts, pushed and fixed onto a guide rod and the heating spiral. The ceramic heating elements are pushed into a metallic heating cartridge tube. The cartridge tube is sealed to avoid direct medium contact and welded pressure-tightly into the tube sheet. The elements can be exchanged without interrupting operation. They are predominantly used for heating fuel oils, thermal oils or other highly viscose fluids.

construction

Page 7: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

construction

c O n s t r U c t i O n | D E s i G n

H E at E r s 7

Design

The installed power depends on the process requirements. also several operating conditions can be reali-zed with one electric heater. The thermal design of electric heater needs to be calculated in such a way that the medium can absorb the energy supplied without exceeding the temperature permitted on the heating surface. The “know how” is based on the capability to distribute the power over a surface in a technically and economically optimum solution. Concentrating the power over a small surface produces a high watt density (W/cm”) and thus a higher temperature on the heating surface. In the most unfavorable case this might lead to a damage of medium or damage of heating elements. In comparison, a conventional heat exchanger needs to have sufficient exchange surface available to be able to supply the energy to the medium to be heated.

The mechanical design of components under pressure is calculated in accordance with harmonized norms such as Pressure Equipment Directive En 13445, En 12993, on request, by using the respective calculation rules in the country of installation or other international standards e.g. aSmE including all necessary tests, certificates and inspections. additionally required conditions such as consideration of nozzle loads by con-nected pipelines, supports and wind loads and seismic safety also belong to the design standard.

Page 8: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

8

switch and control cabinets

Regulation, Control

For all electric heaters, we design and delivery switchboard and control panels for erection in distribution stations or outdoor, here also in hazardous areas. The power is controlled by a signal of 4-20 ma, provided by the customer, either via several heating stages or infinitely variable via thyristor controller. The latter normally disposes of an undercurrent control and/or a 4-20 ma signal for external power indication and are operated in two or three phases in full-wave mode. Before delivery, a general function test is performed, a full current test is feasible as well.

Page 9: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

KO n s t r U K t i O n

H E at E r s 9

The specialists for electric heating systems

switch and control cabinets

s w i t c H a n D c O n t rO l c a b i n E t s | r E F E r E n c E s

2x2 Gas heaters

The double deck gas heaters were design to heat up big gas amounts, in a refinery in the explosion-threate-ned area. Because of the high pressure and temperature the challenge was to distribute the achievement on the surface which proves the optimum solution technically and economically.

Technical Characteristics:> heating capacity 4x = 850KW 3400KW> maximum temperature: 450° c> Design pressure: 122.6 bar> Supply voltage: max. 690 V / ac

Manufacturing Standard > PED 97/23 / Ec> aSmE VIII Div 1-

The range of application:> heating of gas in the hazardous area

The functional principleContinuous heating of the medium by heat exchange between pipe and radiator medium.

Our know-how is in the heat exchange area and optimally adapted to the individual operating conditions adapt to Ensure that the process temperature reaches is permissible without heating surface or the permissible pressure drop is exceeded.

practice examplesThe below-mentioned major projects only present a small selection of all our projects realized.Please contact us if you require additional information.

Page 10: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

10

Hot water boiler type series HWE

The hot water boiler are suited as consumers for mains stabilisation, as autonomous calorifiers without local emission sources, and as a means to secure the district heating supply. your advantage: The hot water boiler can be directly integrated into the district heating mains. The area of application comprises all control range products: Secondary control range (SRl), minute reserve (mRl).

Technical Characteristics:> Power range: 1 to 5 mW> Electrical connection: 690 V/50 hz/3 ph> calculation pressure: up to 30 bar> calculation temperature: up to 230 °c

Manufacturing Standards:> Pressure Equipment Directive (PED) 97/23/Ec> En 12953 / En 13445 / aD-2000

Your advantages:> Stepless power control at high power levels in combination / Infinitely> Boiler produces directly hot water > Large heat transfer area, smallest wing loading> no special requirements for water quality> Direct connection to the district heating network> no heat exchanger required> Supervision-free operation: according to En12953 (TRD 604) available (72 hours control interval) (BoB 72)> high redundancy by up to 250 single heating elements> Sturdy and maintenance-free design

Page 11: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

The specialists for electric heating systems

H E at E r s 11

Take us for granted.Gladly at any Time.

r E F E r E n c E s | s E rV i c E

Apart from careful planning and manufacturing, a professional installation

is essential for the proper function of a heating system.

Our skilled and qualified assembly team offers you this service.

Our employees install, test and put our heating systems including respective

control units into operation.

The quality of our work is guaranteed by regular training measures and the

application of our management system and the SCC** catalogue (safety, health

and environment).

A continuous maintenance of our heating systems and a detailed

technical documentation complete our service package.

SERVIcE PROmISES

Page 12: Our Heaters for your Projects - kloepper-therm.de · > Boiler produces directly hot water > Large heat transfer area, smallest wing loading > no special requirements for water quality

KLÖPPER-THERM GmbH & Co. KGUnterste-Wilms-Straße 2144143 DortmundGermany

P.O. Box 10 22 4044022 DortmundGermany

1 +49 231/5178-0I +49 231/5178-333

[email protected]

The specialists for electric heating systems

KT

PR

02

.En

.11

.14