Otway 34 Current 23.02.15

Embed Size (px)

DESCRIPTION

Otway 34 plan

Citation preview

  • 3 4

    6 7

    8

    10

    9

    Sienna Building Pty Ltd - ABN 66 128 617 532 owns Copyright of this design any reproduction in whole or part without consent is forbiddenThis Brochure is for illustration purposes only and should be used as a guide only. Refer to actual working drawings

    1.

    2.

    3.

    6.

    7.

    8.

    21.00 m

    12.80 m

    Sitting 4.7 x 4.0

    Dining 3.0 x 4.6

    Living 6.0 x 4.6

    3.2 x 3.6Bedroom 3

    3.4 x 3.2Bedroom 2

    5.1 x 4.1Master Bed

    5 3.5 2

    Total House Length

    Total House Width

    Living Area

    Total Area

    Minimum Lot Width

    ??????? 34.0 sq??????? 27.9 sq

    14.00 m

    9. Alfresco 3.0 x 5.4

    4. 3.2 x 3.3Bedroom 4

    10. Garage 6.0 x 5.6

    12

    5

    5. 4.0 x 4.3Bedroom 5

    AW 854x2704 2110x1485

    SD 2

    110x

    2690

    SD 2110x1810AW 1800x1810

    AW 1

    800x

    850

    AW 854x2704 AW 1800x1210

    FW 514x1810

    AW 1027x610

    AW 1

    800x

    850

    2110

    x135

    0

    820

    AW 1

    200x

    1810

    AW 1

    200x

    1810

    AW 1

    372x

    1810

    AW 1

    375x

    2170

    AW1800x850 AW 1027x610

    AW 1

    200x

    1450

    AW1200x610

    AW 1

    800x

    2170

    FW 514x1210

    REF.SPACE

    WMSPACE

    GROUND FLOOR

    FIRST FLOOR

    ROBE

    LIN

    EN

    WIRROBE

    DWSPACE

  • Sienna Building Pty Ltd - ABN 66 128 617 532 owns Copyright of this design any reproduction in whole or part without consent is forbiddenThis Brochure is for illustration purposes only and should be used as a guide only. Refer to actual working drawings

    2W

    2W

    PH.

    S.A.

    S.A.

    2W

    GROUND FLOOR

    FIRST FLOOR

    WP HEATING & COOLING REGISTERS INDICATED ON PLAN ARE SYMBOLIC ONLY. ACTUALREGISTERS SHAPE & LOCATION PER MANUFACTURES RECOMENDATIONS.

    NOTE:

    IMPORTANT:- PROVIDE LIGHT POINT & SINGLE G.P.O. IN ROOF SPACE

    ALARM SENSOR (TYP. WALL MOUNTED)

    ALARM STROBE & SIREN

    ALARM CONTROL PANEL W/- SINGLE GPO @ 2200MM AFL

    ALARM KEYPAD

    ALARM - WHERE SPECIFIED

    GAS DUCTED HEATING UNIT

    CEILING REGISTER (HEATING ONLY)

    CEILING REGISTER (COOLING ONLY)

    AIR CONDITIONER CONDENSORAIR CONDITIONER HEAD

    CEILING FAN ASSELECTED

    HEATING & COOLING - WHERE SPECIFIED

    AC - CONAC - HEAD

    ROOF ACCESS

    RETURN AIR (CEILING MOUNTED).

    RETURN AIR (WALL MOUNTED).

    HTR

    EVAP. COOLER UNITECU

    - WHERE INSTALLED, PROVIDE DIRECT POWER OUTLETS TO COOK TOP,RANGEHOOD, UNDER BENCH OVEN.

    HOT WATER UNIT AS SPEC'D.

    SENSOR.

    M/B EXTERNAL METER BOX.

    SGL P.POINT @ 600MM ON SEP. CIRCUIT.

    SGL WEATHER PROOF P.POINT @ 1050MM.

    DOUBLE POWER POINT @ 1050MM.

    DOUBLE POWER POINT @ 300MM.

    SMOKE DETECTOR. APPROX. POSITION INSTALLED AS PER B.C.A. 3.7.2. & TO COMPLY WITH A.S.3786.

    CEILING LIGHT OUTLET WITH ACRYLIC SHADE.

    INSTALLED AS PER B.C.A. 3.8.5. & TO COMPLY WITH A.S.1668.2.EXHAUST FAN (SELF SEALING).

    WALL LIGHT AS SPEC..

    PARAFLOOD LIGHT WITH SENSOR.

    DOUBLE WEATHER PROOF P.POINT @ 1050MM.

    INTERNAL SWITCHBOARD.

    GAS BAYONET POINT @ 450mm

    1200 FLURO.

    S/B

    DIMMER SWITCH TO FITTING AS WIRED.

    TWO WAY SWITCHING TO FITTING AS WIRED.

    DIM

    2W

    UNLESS NOTEDOTHERWISE

    SINGLE POWER POINT @ 750MM.

    SGL P.POINT TO CEIL-REMOTE CONT. UNIT

    LED (FIXED) DOWNLIGHT.

    TV POINT

    TELEPHONE POINT TO MATCH ADJOINING POWER POINT HEIGHT

    TO BE TERMINATED AT ACCESS HATCH UNLESS SPECIFIED

    WP

    WP

    PH.

    MULTIMEDIA POINT TO MATCH ADJOINING POWER POINT HEIGHT

    TERMINATION BOX

    CEILING LIGHT WITH SPEC. FITTING.

    GP

    T-BOX

    MMP

    COMBINATION EXHAUST FAN & LIGHT.S.A.

    PENDANT LIGHT AS SPEC.

    S

    P

    DISTRIBUTION HUB BOXD-HUB

    DUCTED VACUUM KICKBOARD OUTLET(REFER INTERNALS FOR POSITION)

    DVP KO.DVSDUCTED VACUUM SYSTEM@1500MM APPROX.

    DUCTED VACUUM POINT@300MM

    TV POINT & DOUBLE POWER POINT @SPECIFIED HEIGHT WITH BLOCKING

    1300H