IDEAL SOLUTION FOR:
• Contract marking and Production
• Industrial Marking
• Integrators
• Laboratories and Medical
XLC Laser Workstation
• Laser protective housing
(Laser protection class 1)
• Laser Systems available:
(5, 10, 20, 30 or 40 watts)
• All supply units integrated
• Automatic Programmable Z-axis
• Up to 3 programmable Axis available
The XLC is designed as a perfect “Plug & Play” laser station. Simply connected via USB to PC and you are ready to go. The simple operation, and easy loading and unloading full size workstation and controls, provides a perfect stand-alone powerful marking solution.
Very mobile with standard power connections, a remarkably large load capacity, multiple lensoptions, modular design and options available,and ease of setup, maintenance and use.
The XLC Enclosure can be used as a stand-alone laser marking station or integrated easily into a production line. Using the market proven software, XS designer, automated marks, such as sequential serial numbers, 2D codes
as well as graphic files such as DXF and PLT.
Östling XS and XLC Enclosure Combo
• Maximum safety (laser protection class 1)
• Mobile and flexible, easy to use modular design
• Large main load door and side service/load doors for loading a wide variety of parts to be marked
• Large laser safety rated glass window for safe setup and observing the marking process
• Large load capacity of 605x685x435mm (DxWXH) up to a weight of 90 kg It is also possible to load parts from the sides of the cabinet providing the facility to mark much longer, larger components (subject to safety regulations being followed).
• Powered Programmable electric Z-axis height adjustment for easy focusing and repeatability. (Up to 3 axis available).
• T-slots for quick mounting and setting up of jigs and fixtures
• Near Maintenance free and quiet operation
• Available additional optional Axis, including rotary tool for part handling
Laser markingVery flexible with high quality
Using a highly precise laser beam
a permanent mark is applied to
different materials e.g. different kinds
of metal and plastic.
With the associated software your
marking ideas have no limits. Also
for automated markings, such as
continuous serial numbers, 2D
codes (Data Matrix™) etc our
Laser marking systems are the
best choice.
The "Ready to mark" Laser Marking Station
640 Lakeview Plaza Blvd Suite B & C, Worthington, OH 43085Phone: +1 614-231-3559 - Fax: +1 614-436-4898
Visit us at our website www.ostling-markingusa.com or also at facebook, twitter and youtube
USA
One supplier for all your marking needs
www.ostling-markingusa.com
(Data Matrix™), etc can be easily generated.
• Factory and High Production
• R&D to Full Product DPM
• Standard 110VAC @20A power
• Safety Stack Light (with HMI Tie-In) and HMI start/stop controls
XLCXLC
• Prepared for extraction system
• HMI Interface/Stack Light/Control Surface
Programmable, Z-, Y-, X or Rotary Axis
T-Slot Tooling Plate for Fixturing
HMI / PLC Laser Control Interface
(optional) Externally Mounted Focus Finder
Fume Extraction System
Stack Light (with HMI/Controller Status Tie In)
Leveling Casters
Rack Mounting for Laser Controller and Industrial PC with slide out keyboard/mouse tray
Manual Door (with optional Auto Door) and 1 additional service/loading doors (all interlocked)
CLASS 1 Laser Workstation
Modular Design to allow for customization of marking area and laser location
Th
e "
Re
ad
y t
o m
ark
" L
ase
r m
ark
ing
sta
tio
n
CXLXLC
Windows XP (SP2), Vista, Win 7, 8, 10
Technical Data LasOnAll XS / XLC Enclosure
Radiation Source XS 5 XS 10 XS 20 XS 30 XS 40
Laser Source Solid state laser Nd:YVO4 (1064 nm), diode-pumped, actively Q-switched
Nominal CW Laser Power 5 W 10 W 20 W 30 W 40 W
Beam Quality M² < 1.5 < 2 < 2.2 < 2.5 < 2.5
Beam Diameter 5 mm 6 mm 6 mm 8 mm 9 mm
Pulse Width 4 - 40 ns 5 - 20 ns 5 - 20 ns 7 - 40 ns 7 - 40 ns
Pulse Width @ 20 kHz 4 ns 5 ns 5 ns 7 ns 8 ns
Pulse Energy @ 20 kHz 0.3 mJ 0.5 mJ 0.8 mJ 1.3 mJ 2.0 mJ
Pulse Peak Power @ 20 kHz 20 kW 60 kW 90 kW 110 kW 120 kW
Long-term Power Instability < 5% < 5% < 5% < 5% < 5%
Cooling System Integrated thermo-electrical ventilation
Target Diode Integrated red laser diode =635 nm 3 mW (class 2M)
Laser Protection Class XL Workstation Class 1 / OEM Laser Class 4
Safety Parameters1
PL / Category: PLe / Cat.4
DC: 99% (high)
CCF: >65 points
B10d Value (For One Channel) 12,000,000 7,500,000 2,500,000 20,000,000 20,000,000
General
Resonator Weight 4.5 kg 6.5 kg
Resonator Diameter 244x98x145 mm 334x98x151 mm
Rack Weight 15 kg 18 kg
Rack Dimensions 434x454x177 mm 434x454x223 mm
Electrical Connection Values 90 to 264 VAC, 50/60 Hz, < 600 W @ XS 40
Operating Temperature +15 to +35 °C (46 to 95 °F)
Humidity < 90% non-condensing
Deflector Unit
Standard
F-Theta Lens FL 100 FL 163 FL 254 FL 330 FL 420
Inscription Area 65x65 mm 130x130 mm 190x190 mm 230x230 mm 290x290 mm
Spot Size in Focus < 40 µm < 65 µm < 100 µm < 130 µm < 150 µm
Working Distance 97mm
Deflection Speed Up to 5000 mm/s
Technical Data LasOnAll XS / XLC Enclosure
www.ostling-markingusa.com
180mm 296mm 387mm 493mm
Technical Data LasOnAll XS DPSS Laser5W, 10W, 20W, 30W and 40W