15
Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of Fountains, Suite # 108, Fountain Hills, AZ 85268, U.S.A. Phone: +1 (480) 816-8672 Fax: +1 (480) 816-0115 E-mail: [email protected] Web Site: http://www.oriontelecom.com

Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Embed Size (px)

Citation preview

Page 1: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

E1 Automatic Protection Switching Solution E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch)(1+1 E1 Redundancy Switch)

Updated : November, 2005

Slide 1

16810, Avenue of Fountains, Suite # 108,Fountain Hills, AZ 85268, U.S.A.

Phone: +1 (480) 816-8672Fax: +1 (480) 816-0115

E-mail: [email protected] Site: http://www.oriontelecom.com

Page 2: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

BASIC THEORY OF OPERATIONBASIC THEORY OF OPERATION

Slide 2

E1 Redundancy Switch is designed to provide 1+1 redundancy support for two typical E1 links case scenarios:

• An independent point-to-point E1 link between two "E1 USER PORTS" • TWO groups of E1 links connected via a higher order multiplexer link.

Since each SWITCH Card supports one E1 link, up to 16 E1 links, can be supported by an E1 Redundancy Switch Shelf. Two Systems are required for implementation of the 1+1 redundancy switch solution.

One system must house Switch Cards configured as "MASTER" for connection at one end of the E1 links (say the near end).

The other system must house Switch Cards configured as "SLAVE" for connection at the other end of the E1 links (say the far end).

Page 3: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

FEATURES AND HIGHLIGHTSFEATURES AND HIGHLIGHTS

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

• Provides 1+1 E1 redundancy link (active+standby) between any two complementing transmission mediums.

• Provides 1+1 E1 redundancy support to higher order multiplexers eg. E2,E3.

• System configuration & management interface through "CLI" text based commands.

• Transport A-bis Interface or E1’s.

• Provide 1 + 1 Protection Routing / Path between BSC and BTS.

• Provide following interfaces at BSC / BTS Over E1 links:

• i) E1 / A-bis Interface.

• ii) 10BaseT Ethernet Bridge.

• iii) RS232 Async Serial (for site monitoring).

• iv) NO / NC Relay / Alarm Extensions (Extend alarms

originating on dry relay contacts).

Slide 3

Continued..

Page 4: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Features continued

• Optional - 128 ms Echo - Cancellation and VQE features at BSC.

• Maximize mobile operator service availability and network resiliency through VCL-MegaConnect-Jr. Path - Protection enabled facility

• These ensure that mission critical voice, data, control and management traffic are properly supported and maintained even during T1 / E1 backhaul facility outages.When the working link fails, the protection link becomes active.

• During normal Operation, VCL-MegaConnect-Jr sends duplicate traffic across both the working and dedicated protection E1 / T1 facilities while continuously maintaining the performance of both links to determine which link shall be utilized.

• Through the comprehensive digital access cross-connect and remote management capabilities integrated within VCL-MegaConnect-Jr, backhaul T1 / E1 facilities can be optimally groomed to reduce both Capital Expenditure and improve Network reliability.

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 4

Continued..

Page 5: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 5

Features continued

• In the event of a failed or degraded T1 / E1 link, the traffic is automatically transfered from the previously working link to the duplicate protection link in accordance with the pre determined operating parameter programmed by the network operator.

• During normal Operation, VCL-MegaConnect-Jr APS passes independently traffic across both the working and protection E1 / T1 facilities while continuously maintaining the performance of both links to determine which to utilize for critical traffic

• Traffic Protection

• Alternate Facility Advantages

• Service Differentiation Agreements

• Increased Network Reliability Resilience

• Media and Path Diversity

• Remote Management

Page 6: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

BENEFITSBENEFITS

• Customer Relation

• Competitive

• Service Level

• Back-haul Network

• Technology Migration

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 6

Page 7: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Slide 7

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

1) User Programmable 1+1 Protection Parameters:

a) Loss of Signal

b) Loss of Frame

c) Loss of Multi-Frame

d) AIS

e) Excessive CRC4 Violation

2) Critical Links / Critical Time-Slots

Page 8: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

ApplicationsApplicationsProviding 1+1 alternate paths between any two Transmission medium (active+standby). e.g:-

• Fiber / Fiber.

• Radio / Fiber.

• Radio / HDSL

• Fiber / HDSL etc.

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 8

Page 9: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 9

Page 10: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 10

Page 11: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 11

Page 12: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 12

Page 13: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 13

Page 14: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

Slide 14

Page 15: Orion Telecom Networks Inc. 2005 E1 Automatic Protection Switching Solution (1+1 E1 Redundancy Switch) Updated : November, 2005 Slide 1 16810, Avenue of

Orion Telecom Networks Inc. 2005

Thank you for your attentionThank you for your attention

Orion Telecom Networks Orion Telecom Networks Inc.Inc.

For more details visit us at our Web Site at

http://www.oriontelecom.com16810, Avenue of Fountains, Suite # 108,

Fountain Hills, AZ 85268, U.S.A.

Phone: +1 (480) 816-8672 Fax: +1 (480) 816-0115E-mail: [email protected]

Slide 15