ORANGE COUNTY GOVERNMENT LEVO CAT SCHOOL ORANGE COUNTY MAYOR DISTRICT 1 COMMISSIONER DISTRICT 2 COMMISSIONER DISTRICT 3 COMMISSIONER DISTRICT 4 COMMISSIONER DISTRICT 6 COMMISSIONER DISTRICT 5 COMMISSIONER TERESA JACOBS S. SCOTT BOYD FRED BRUMMER JOHN MARTINEZ TIFFANY MOORE RUSSELL TED EDWARDS JENNIFER THOMPSON HVAC / ROOF RETROFIT BID DOCUMENTS JUNE 1, 2012 6350 WADSWORTH RD. MOUNT DORA, FLORIDA 32757 MPE # 2011-154

ORANGE COUNTY GOVERNMENT - ocfl.net

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

ORANGE COUNTY GOVERNMENT

LEVO CAT SCHOOL

ORANGE COUNTY MAYOR

DISTRICT 1 COMMISSIONER

DISTRICT 2 COMMISSIONER

DISTRICT 3 COMMISSIONER

DISTRICT 4 COMMISSIONER

DISTRICT 6 COMMISSIONER

DISTRICT 5 COMMISSIONER

TERESA JACOBS

S. SCOTT BOYD

FRED BRUMMER

JOHN MARTINEZ

TIFFANY MOORE RUSSELL

TED EDWARDS

JENNIFER THOMPSON

HVAC / ROOF RETROFIT

BID DOCUMENTSJUNE 1, 2012

6350 WADSWORTH RD.MOUNT DORA, FLORIDA

32757MPE # 2011-154

GENERAL NOTES,SYMBOL LEGEND,

SHEET INDEX

E-001

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

FLOOR PLAN - RENOVATION - ELECTRICAL

E-101

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

COPYRIGHT ME, LLC 06/01/03 VERSION: A6E REVISED: 1/16/2012VOLTS L/N: 120VOLTS PH.: 240 PANEL: MA_REVISED EXISTING : NOPHASE : 1 MLO(***) 600 SECTIONS : 1MOUNTING : SURFACE MCB NEMA 3R :TYPE : NQO SH.TRIPMFR : SQ D GFP

NOTES AND REFERENCE NOTES:GENERAL NOTES: <------------AIC RATING (**)------------>(1) ALL C.B.'S FEEDING HVAC EQUIPMENT TO BE HACR TYPE. SERIES RATED 35 KA(*) MFR = SIZE CB PER MFR. RECOMMENDATIONS.(2) ALL C.B.'S FEEDING ELEV EQUIP TO BE SHUNT-TRIP TYPE. FULLY RATED KA $ = NEW CB IN EXIST SPACE(3) ALL C.B.'S FEEDING ELEV EQUIP TO BE SIZED AS REQ'D BY MFR. & = REPLACE EXIST CB WITH NEW(4) ALL C.B.'S FEEDING HID LTG TO BE HID RATED. (*) NOTE: MAY REQUIRE FULL RATING TO ACHIEVE SH = SHUNT TRIP C.B.(5) NO MULTIWIRE BRANCH CKTS ARE ALLOWED AF = ARC FAULT CB(6) NOT USED.

OPTIONAL CALC NOTOTAL AMPS A PH 319 (***) NOTE: SIZE SHOWN IS MINIMUM ACCEPTABLE MLO

AMPERAGE. INCREASE SIZE IF REQUIRED TO ACHIEVEQUANTITY OF POLES OR BREAKER SIZE/AIC RATING ASCALLED FOR IN SCHEDULE.

ACTUAL CONN LOAD 79 KVA 330 AMPSTOTAL AMPS B PH 327 DEMAND 79 KVA 330 AMPS

DIVERSITY 79 KVA 330 AMPSERROR CODE TRANSFORMER SIZE KVA

SECTION 1 WITH MAINS WIDTH: 20 DEPTH: 6.00LOAD C.B.

AMPSC.B.

POLEREF

NOTECKT.NO.

CKT.NO.

REFNOTE

C.B.POLE

C.B.AMPS

LOAD

DESCRIPTION CONN TYPE AMPS AMPS AMPS AMPS AMPS AMPS DESCRIPTION CONN TYPE

AHU-1 34 10.0 34 45 2 1 2 2 40 21 HP-1 21 12.3-------- 34 10.0 34 -------- -------- 3 4 -------- -------- 21 -------- 21 12.3AHU-2 40 10.0 40 60 2 5 6 2 50 23 HP-2 23 12.3-------- 40 10.0 40 -------- -------- 7 8 -------- -------- 23 -------- 23 12.3AHU-3 20 10.0 20 30 2 9 10 2 25 HP-3 14 12.3-------- 20 10.0 20 -------- -------- 11 12 -------- -------- 14 -------- 14 12.3AHU-4 20 10.0 20 30 2 13 14 2 25 14 HP-4 14 12.3-------- 20 10.0 20 -------- -------- 15 16 -------- -------- 14 -------- 14 12.3SPACE 1 17 18 1 SPACEOAU-1 HEATER 50 12.3 50 70 2 19 20 2 70 41 OAU-1 41 13.2-------- 50 12.3 50 -------- -------- 21 22 -------- -------- 41 -------- 41 13.2SPACE 1 23 24 1 SPACEEWH-1 50 6.0 50 70 2 25 26 1 20 6 EF-1 6 9.0-------- 50 6.0 50 -------- -------- 27 28 1 20 SPARE 0.2SPARE 0.2 20 1 29 30 1 20 SPARE 0.2SPARE 0.2 20 1 31 32 1 20 SPARE 0.2SPARE 0.2 20 1 33 34 1 SPACESPACE 1 35 36 1 SPACESPACE 1 37 38 1 SPACESPACE 1 39 40 1 SPACESPACE 1 41 42 1 SPACE

SUBFEED LUGS/BREAKER SUBFEED LUGS/BREAKERS.F. S.F.

--------------- ------- ------- S.F. S.F. -------- ------- ------------------------------ ------- ------- S.F. S.F. -------- ------- ---------------

MECHANICAL/KITCHEN EQUIPMENT FEEDER SCHEDULE FOR (9): O.C. LEVO CAT SCHOOL- HVAC REPLACEMENT COPYRIGHT ME, LLC Version : W6 REVISED: March 1, 2012 DATE: June 1, 2012

EQUIPMENT DESCRIPTION VOLTS PH NEUTRALY/N

LARGEST MOTOR COMPRESSOR ADD'L MOTORS HEAT STRIPS MISCAMPS

TOTALFLA

MCA(10)

MOCP(10)

PANELCB (5)

DISCONNECT SWITCH STARTER WIRE PERPHASE (6)

NEUTRALWIRE (7)

GROUNDWIRE

WIREMATERIAL

# OFRUNS

CONDUITSIZE % VD NOTES

(SEE BELOW)HP FLA LRA FLA(11) LRA FLA LRA KW AMPS CODE SIZE (1) FUSE (2) TYPE (3) CODE TYPEAHU-1 240 1 N 0.50 4.9 29.4 7.0 29.2 34 45 1 60 NF #6 #10 COPPER 1 0.75 MAHU-2 240 1 N 0.75 6.9 41.4 8.0 33.3 40 60 1 60 NF #6 #10 COPPER 1 0.75 MAHU-3 240 1 N 0.33 3.6 21.6 4.0 16.7 20 30 1 30 NF #10 #10 COPPER 1 0.75AHU-4 240 1 N 0.33 3.6 21.6 4.0 16.7 20 30 1 30 NF #10 #10 COPPER 1 0.75 M

HP-1 240 1 N 20 168 1.0 13.2 21 26 40 40 2 60 35 3R #10 #10 COPPER 1 0.75 0.46HP-2 240 1 N 22 168 1.4 13.2 23 29 50 50 2 60 35 3R #10 #10 COPPER 1 0.75 0.51HP-3 240 1 N 13 102 0.5 13.2 13.5 17 25 25 2 60 20 3R #12 #12 COPPER 1 0.75 1.56HP-4 240 1 N 13.0 102 0.5 13.2 14 17 25 25 2 60 20 3R #10 #10 COPPER 1 0.75 1.66

OAU-1 240 1 N 0.50 4.9 29.4 31 240 5.4 41.4 41 60 70 70 2 100 60 3R #4 #8 COPPER 1 0.75 1.27

NOTES ( ) NOTES:(A)=CONNECT VIA LINE VOLTAGE T'STAT BY DIV. 15/23 CONTRACTOR.

(1) PROVIDE DISC SW AT ALL PIECES OF EQUIPMENT AS REQUIRED BY THE N.E.C. AND AHJ UNLESS PROVIDED BY OTHERS (INCLUDING AT MOTORS AND AT STARTERS. MCP = MOTOR CIRCUIT PROTECTOR W/COMBINATION STARTER (B)=CONNECT VIA CONTROL DEVICES BY DIV. 15/23 CONTRACTOR.

(2) FUSES SHOWN FOR REFERENCE ONLY, PROVIDE FUSES AS RECOMMENDED BY EQUIPMENT MANUFACTURER. MMS = MANUAL MOTOR STARTER SWITCH WITH OVERLOADS AND PILOT LIGHT (C)=CONNECT VIA VFD/AFD WITH INTEGRAL DISC. SW.

(3) PROVIDE NEMA OUTDOOR RATED ENCLOSURES FOR ALL DISC SWS MOUNTED OUTDOORS. I = NEMA I ENCLOSURE (D)=CONNECT VIA COMBINATION DISC/STARTER BY DIV. 15/23 CONTRACTOR.

(4) COORDINATE STARTER TYPE WITH MECH EQUIP INSTALLER . 3R = NEMA 3R ENCLOSURE (E)=CONNECT VIA DISC SWITCH AT EQUIP. BY DIV. 15/23 CONTRACTOR.

(5) CONTRACTOR TO VERIFY THAT C.B. FOR COMPRESSORS IS SUFFICIENT TO ALLOW STARTING OF UNIT, IF REQUIRED FOR STARTING C.B. TO BE INCREASED TO A MAX ALLOWEDBY N.E.C. CB TO BE HACR RATED. 4SS = NEMA 4 WATER TIGHT STAINLESS STEEL ENCLOSURE (F)=PROVIDE FULL SIZE NEUTRAL.

(6) #12 FEEDERS SHOWN AND OVER 50FT. LONG TO BE #10 FOR 120V CIRCUITS. #12 FEEDERS SHOWN AND OVER 100 FT. LONG TO BE #10 FOR 277 V CIRCUITS. 4 = NEMA 4 WATER TIGHT NON-CORROSIVE ENCLOSURE (G)=MMS WITHOUT OVERLOADS.

(7) NEUTRAL CONDUCTOR TO BE SAME SIZE AS PHASE CONDUCTORS. VFD/AFD = VARIABLE (ADJUSTABLE-AFD) FREQ DRIVE UNIT (H)=CONNECT VIA STARTER IN MCC (BY DIV 16/26).

(8) MOTOR CB IS SIZED BASED ON NEMA CODE 'F' OR HIGHER. CHANGE CB SIZE IF REQUIRED DUE TO NEMA CODE OF MOTOR PER N.E.C. NF = NON-FUSED. WHERE ACCEPTABLE TO AHJ, CONTRACTOR MAY USEPROPERLY RATED MOTOR SWITCH FOR DISCONNECT SWITCH (I)=2 SPEED,1 WINDING MOTOR/STARTER.

(9) ALL FEEDERS 100 AMP AND LESS ARE BASED ON 60 DEGREE CONDUCTOR/TERMINATION RATING. ALL OTHER FEEDERS ARE BASED ON 75 DEGREE CONDUCTORTERMINATIONS. PROVIDE AND INSTALL PROPER TERMINATIONS ON ALL EQUIPMENT PROVIDED BY ANY DIVISION AND/OR SECTION OF THE CONTRACT DOCUMENTS. PROPERTERMINATIONS TO BE AS REQUIRED TO MATCH CONDUCTOR WITH REQUIRED AMPACITY.

AHJ = AUTHORITY HAVING JURISDICTION. (J)=COORDINATE WITH DIV.15 TO BALANCE LOAD OF 1 PHASE FTB MOTORS.

(10) BASED ON MANUFACTURER'S RECOMMENDATION. FNVR = FULL VOLTAGE NON-REVERSING (K)=PROVIDE NEW STARTER IN MCC TO MATCH EXISTING. SEE MCC SCHED.

(11) OR BRANCH CIRCUIT SELECTION CURRENT WHEN AVAILABLE. DFNVR = DUAL VOLTAGE NON-REVERSING (L)=WHERE MOTOR IS FED FROM MCC, PANEL CB NOT REQUIRED

FVC = FULL VOLTAGE CONTACTOR (M)=CONNECT EXIST DISC SWITCH AT MOTOR. MODIFY AS NOTED ON DRWGS(N)=CONNECT EXIST DISC SWITCH AT MOTOR. MODIFY AS NOTED ON DRWGS(O)=(P)=

PANEL SCHEDULESAND MECHANICALFEEDER SCHEDULE

E-601

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

FLOOR PLAN- DEMOLITION- ELECTRICAL

ED-101

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

PROJECT DESIGN CONDITIONSTEMPERATURE CONDITIONS BUILDING LOAD CONDIITONS

OUTDOOR INTERNAL LOADSDRY BULB

(F)WET BULB

(F) COMMENTS QUANTITY UNITS COMMENTS

SUMMER 94 77 (0.40% mean conicided db/wb) PEOPLE 38 PEOPLE PER CODE

LIGHTING 2 W/SF EXISTING

WINTER 42 . (99.6% db) EQUIPMENT 0.25 W/SF EXISTING

DAILY RANGE 16.6 X VENTILATION AIR . . REFER TO VENTILATIONSCHEDULE

LOCATION BASED ON ASHRAE WEATHER DATAFOR: ORLANDO, FL FLOOR AREA 3,775 SQ. FT EXISTING

INDOOR EXTERNAL LOADSDRY BULB

(F) RH % COMMENTS "U"FACTOR

SOLAR HEATGAIN COEFF. COMMENTS

COOLING 74 50 WALL 0.1 X ASSUMED PARAMETERS

HEATING 70 X ROOF 0.049 X ASSUMED PARAMETERS

GLAZING 0.93 0.59 ASSUMED PARAMETERS

VENTILATION DETERMINATION IS BASED ON OCCUPANCY PER ASHRAE STD. 62-2007

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

ABBREVIATIONSGENERAL NOTES

M-001

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

FLOOR PLAN - RENOVATION- MECHANICAL

M-101

SPLIT SYSTEM AIR HANDLING UNIT WITH ELECTRIC HEATING COIL SCHEDULE:

UNIT NO. LOCATION

SUPPLY AIR FAN DATA COOLING COIL DATA ELECTRIC HEAT COIL DATA FILTER DATA SELECTION BASED ON

REMARKSTOTAL MAX.CFM

TOTAL O.A.CFM

FAN DATA EAT F LAT F SEER/EER @

ARI

FACEAREA CFM EAT F LAT F HEAT KW STAGES VOLT/

PHMIN. MERV

RATING MANUF. MODELESP INH20 HP FLA RPM VOLT PH DB WB DB WB

AHU-1 RM. 107 1,390 140 0.50 0.50 4.10 230 1 79.6 67.9 60.05 58.64 13.0/11.5 4.45 1,390 70 85.9 7.00 1 240/1 10 CARRIER FB4CNF042T00 1,2,3,4AHU-2 RM. 107 1,650 140 0.50 0.75 6.00 230 1 79.4 67.8 61.9 60.88 13.2/11.5 5.93 1,650 70 85.3 8.00 1 240/1 10 CARRIER FB4CNF060T00 1,2,3,4AHU-3 RM 117 800 0 0.50 0.33 2.80 230 1 78.0 67.0 58.67 57.24 13.2/11.0 2.23 800 70 85.8 4.00 1 240/1 10 CARRIER FB4CNF030T00 1,2,3,4AHU-4 RM. 116 800 0 0.50 0.33 2.80 230 1 78.0 67.0 58.67 57.24 13.2/11.0 2.23 800 70 85.8 4.00 1 240/1 10 CARRIER FB4CNF030T00 1,2,3,4

NOTES:

1-VERTICAL DRAW THRU/TOP DISCHARGE 4-HEATING COIL TO BE IN REHEAT POSITION2-CAV MOTOR STARTER CONTROLLED3-MINIMUM MERV 10 FILTER

SPLIT SYSTEM HEAT PUMP SCHEDULE:

m SERVING

UNIT DATA FAN MOTOR COMPRESSOR DATA UNIT ELECTRICAL DATA SELECTION BASED ON

REMARKSCAPACITYMBH

COND.EAT F NO. HP

FLA(ea) VOLT PH QUANTITY STEPS VOLT PH LRA (ea) RLA

(ea) VOLT PH MCA MOCP MANUFACTURER MODEL

HP-1 AHU-1 42.02 94 1 1/10 0.8 230 1 1 1 230 1 109 19.9 230 1 25.7 40 CARRIER 25HBC342A003 1HP-2 AHU-2 50.47 94 1 1/4 1.4 230 1 1 1 230 1 117 21.8 230 1 28.7 50 CARRIER 25HBC348A003 1HP-3 AHU-3 23.43 94 1 1/18 0.5 230 1 1 1 230 1 58.3 12.8 230 1 16.8 25 CARRIER 25HBC324A003 1HP-4 AHU-4 23.43 94 1 1/18 0.5 230 1 1 1 230 1 58.3 12.8 230 1 16.8 25 CARRIER 25HBC324A003 1

REMARKS1 HEAT PUMP

100% OA GROUND-MOUNTED PACKAGED AIR CONDITIONER SCHEDULE: Specification Section 15772

UNIT NO. SERVING

UNIT DATA AHU FAN DATA COOLING COIL DATA CONDENSER FAN MOTOR COMPRESSOR DATA UNIT ELECTRIC DATA

REMARKSCAPACITYBTUH

COND.EAT F

SAT.SUCT. F

REFRIGTYPE

TOTALCFM OA CFM

EXT.STATIC P.

IN H20

MOTOR DATA EAT F LAT F

EER @ARI NO.

FLA(EACH)

VOLT(EACH)

PH(EACH) QTY STEPS VOLT PH RLA (ea) LRA (ea) VOLT PH MCA MOCP MANUFACTURER MODEL

HP RPM VOLT PH DB WB DB WB

OAU-1 CLASSROOM AREA 76,450 94 45 R-410a 1040 1040 0.50 1/2 1725 115 1 94.0 76.0 54.8 54.8 11 1 5.4 240 1 1 1 240 1 30.8 . 240 1 66.8 70 ADDISON PCA071 SEE BELOW

NOTES:1. PROVIDE 6-ROW EVAPORATOR COIL 9. PROVIDE WITH SUBCOOLING COIL (MOISTUREMISER)

2. PROVIDE DUAL CIRCUIT HOT GAS REAHEAT 10. PROVIDE WITH HOT-GAS REHEAT & SUBCOOLING COILS (HUMIDIMIZER)

3. PROVIDE HOT GAS BYPASS 11. PROVIDE WITH COMBINATION THERMOSTAT/HUMIDISTAT (THERMIDISTAT)

4. PROVIDE VARIABLE FREQUENCY DRIVE 12. PROVIDE TAB REPORT.5. PROVIDE PHASE/VOLTAGE MONITOR6. STAGGER-START DELAY FOR THE COMPRESSORS7. PROVIDE MERV 10 FILTERS8. 100% OA UNIT.

Duct & Pipe Construction & Insulation Requirements Schedule

Service Thickness Type Notes

Supply Air Ducts

Ducts located outdoors or in soffit exposed toweather: Installed R-8

Exposed: Rigid fiberglass with corner angles withouter weatherproof sheet metal jacket sealed withFlex-Clad 400 as manufacturered by MFM BuildingProducts Corps.Concealed: .75# density blanket

AC Unit to Terminal - Balance of ductwork toterminal exposed 50 deg air system: Installed R-6

Exposed: 2" rigid fiberblass with corner angles.Concealed: .75# density blanket.

Return Air Ducts

All return air ductwork:Concealed - 2" thick external wrap Exposed- 1-1/2" rigid board with corner angles

Refrigerant Piping

Suction (RS) (Temp 35 - 45 deg F):Up to 2": 3/4" Closed Cell Elast.2-1/2" thru 4": 1" Closed Cell Elast.5" thru 8": 1-1/2" Foamglas

RL (Temp 90 - 130 deg F):Up to 2": Not Required2-1/2" thru 4": Not Required5" thru 8": 1-1/2" Foamglas

NOTES:Refer to specification section 15250 for more details and information

Insulation must meet or exceed ASHRAE 90.1-2010, Table 6.8.3 (whichever is greater)

GRILLE, REGISTER AND DIFFUSER SCHEDULE: Specification Section 15870

UNIT NO.TYPE SERVICE MOUNTING DATA CONSTRUCTION DATA SELECTION BASED ON:

REMARKSG R D SA RA EA CEILING DUCT

WALLSHAPE MATERIAL COLOR

PATTERNMANUFACTURER MODEL

HIGH LOW 1-W 2-W 3-W 4-W E/RG-1 X X X SQUARE ALUM. WHITE X TITUS TMS-AAG-2 X X X X SQUARE ALUM. WHITE X TITUS 50FG-3 X X X RECT. ALUM. WHITE X TITUS 350FL

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

SCHEDULES- MECHANICAL

M-601

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

DETAILS- MECHANICAL

M-701

MPE JOB #: 2011-154

SEAL

BID DOCUMENTS

FLOOR PLAN - DEMOLITION- MECHANICAL

MD-101

MPE JOB #: 2011-154

SEAL

MIGUEL LAZARO MARTINAR 8255

CODE ANALYSISABBREV., SYMBOLS.

DRAWING INDEX

A-101

CODE ANALYSIS

ELEVATION/SECTION MATERIALS

MATERIAL SYMBOLSABBREVIATIONS ARCHITECTURAL SYMBOLS

A-101 CODE ANALYSIS, ABBREVIATIONS, SYMBOLS, & INDEX.A-102 MASTER ARCHITECTURAL NOTES.AD-201 FLOOR PLAN - DEMOLITION.AD-301 REFLECTED CEILING PLAN - DEMOLITION..AD-401 ROOF PLAN - DEMOLITION.A-201 FLOOR PLAN - RENOVATION.A-301 REFLECTED CEILING PLAN - RENOVATION.A-401 ROOF PLAN - RENOVATION.A-601 BUILDING SECTIONS.A-801 PENETRATION DETAILS.

ARCHITECTURAL DRAWING INDEX

01 VICINITY MAPNTS

SORRENTO

WALSWORTH RD

DUDLEY AVE.

TER

RE

LL R

OA

D

RO

UN

D L

AK

E R

D

CO

UN

TY R

OA

D 4

37

S C

LAY

TON

ST.

SADLER AVE.

OR

AN

GE

BLO

SS

OM

TRIA

L.

JONES AVE.

ORANGE BLOSSOM

TRIAL.

W. PONKAN RD

YOTHERS RD

E5 AVE.

DO

NN

ELL

Y S

T.

W KELLY PARK ROAD

ADAIR AVE.

O.C.LEVO CAT SCHOOLLOCATION