Floor PlansSheet 1
CL/4H/1172/01/L20131:50-RDLDEC 16
FOR DETAILS OF DOORS AND
WINDOWS REFER TO
SCHEDULE.
FOR DETAILS OF LINTELS OVER
REFER TO DOOR/WINDOW
SCHEDULE.
DIMENSIONS TAKEN FROM
FACE OF BRICK OR BLOCK, AND
TIMBER STUD TO TIMBER STUD.
New Wardrobe Specification
-
ACCREDITED CONSTRUCTION DETAILS (ACD's)
This document is to be referred to on all issues concerning
insulation continuity and airtightness during the build
programme. The use of ACD's provides full compliance
with the performance standards published in the Building
Regulations Approved Documents to Part L.
HIDING OF PIPE RUNS
W.C. CONNECTED DIRECTLY TO
I.C. WITH WHB WASTE PIPE
BRANCHED INTO W.C. WASTE
BELOW SLAB.
FOR KITCHEN/UTILITY ELEC
LAYOUTS REFER TO SEPARATE
1:20 SCALE DWG.
KITCHEN EXTRACT VIA COOKER
HOOD, UTILITY VIA WALL
MOUNTED FAN CAPABLE OF
EXTRACTING AT A RATE NO
LESS THAN 60litres/sec.
KITCHEN & UTILITY WASTES TO
BE SEALED AND HAVE DIRECT
WASTE CONNECTIONS
PROVIDE BLOCKING PIECES
BETWEEN STUDS TO GIVE FIXING
FOR SANITARY APPLIANCES
360mm WHB MAX PROJECTION
NOT TO EXCEED 280mm FROM
PLASTERBOARD
SMOKE ALARMS TO THE
DWELLING NEED TO BE INTER
LINKED AND MAINS OPERATED.
REFER TO GENERAL POSITION
OF LIGHT SWITCHES/SOCKETS
UNLESS DIMENSION SHOWN.
REFER TO GENERAL POSITION
OF RADIATORS UNLESS
DIMENSION SHOWN.
CEILING MOUNTED EXTRACT FAN
TO BATHROOM
CEILING MOUNTED EXTRACT FAN
TO ENSUITE
cooker extract
GROUND FLOOR PLAN
PIR
FAN
EXT.
2
W.C.
UTILITY
KITCHEN
FAMILY
LOUNGE
HALL
A
Acoustic partition
1
2
3
4
5
2
2
rwp
rwp
rwp
rwp
rwp
300 3275 100 2080 100 3613 300
4132 900 4736
9768
300 3153 300 2600 300 2815 300
1003 1200 1250 743 1714 743 912 1200 1003
3453 3200 3115
9768
30
09
28
30
02
68
03
00
26
20
30
0
44
02
40
04
40
71
71
20
01
00
3
32
80
29
20
62
00
30
09
28
30
02
60
03
00
27
00
30
0
85
01
20
08
50
10
50
12
00
10
50
29
00
33
00
62
00
12
28
12
28
338
338
18
85
63
18
00
63
103763980
260 2080 260
15
0
89
6
40
08
96
76886
75
08
96
S&VP
DOOR LEAF TO
OPEN
INDEPENDANTLY
gas
Elec
rwp
BATH
ES
CYL
Acoustic partition
80
0
500750
FIRST FLOOR LAYOUT
rwp
S&VP
3
4
5
W14
access
roof
W12
W13
W7
W8
W9
BED 4
BED 2
W10
W11
BED 3
LANDING
rwp
BED 1
rwp
W15
Acoustic partition
Acoustic partition
Acoustic partition
A
rwp
rwp
300 2300 63 2656 63 725 1335 300
3683 915 1790 915 2465
9768
300 3153 300 2600 300 2815 300
1003 1200 1250 1143 915 1143 912 1200 1003
3453 3200 3115
9768
3403 63 2575 63 3065
46
01
80
0
12
72
63
43
76
3
12
72
63
260 298
26
67
63
28
70
30
02
68
03
00
26
20
30
0
10
40
12
00
10
40
71
71
20
01
00
3
32
80
29
20
62
00
338
338
12
28
30
09
28
30
09
28
30
02
60
03
00
27
00
30
0
12
28
99
39
15
99
31
19
39
15
11
93
29
00
33
00
62
00
81
0
76
6
7
8
9
10
11
12
13
63 968 63 986 63
2
81
0
810 64
rwp
6363 1900
72
3
60
0
734
255
76
65
8
75
06
3
20
08
10
387
1485632153
63
563
40
5
743 743
60
07
00
1172 SQ FT
THE BRERETON
SLOPING CEILING120mm thick Polyisocyanurate Insulation Board (PIR) with thermalconductivity W/mk of 0.022, BBA certified for use in pitched roofapplications fixed between rafters and retaining a minimum 20mmventilation gap between board and u/s of breathable membrane, and heldin place with 12.5mm Foilback plasterboard with 3mm skim. Note, for allroom in roof with party wall situations a further 1 layer of 12.5mm wallboard with 3mm skim finish to be added to satisfy Robust Details. Toachieve min u-value of 0.21 W/m²k.
64 810
Temp
Purmo Compact Radiators EN442 (@Dt50)
Room Catalogue Watts A Len Hgt
Bedroom-3/2
Radiator Schedule - CLASS A CONDENSING PRESSURISED SYSTEM
Bedroom-1/2
21
Bedroom-2/2
Bathroom/2
En-Suite/2
Lounge/1
Lounge/1
Living/Kitchen
Utility/1
WC/1
Hall/1
Landing/2
Bedroom-4/2
21
21
22
22
IG FRONT DOOR WITHDOUBLE MATCHINGSIDELIGHT FT070
1000
60
0
OPTIONAL - 2 x 600 door wardrobe
by specialist to suit full width & floor
to ceiling height of wardrobe space -
IMPORTANT - supplier to undertake
on site measure
OPTIONAL
IMPORTANT
658
50
0
STANDARD
IMPORTANT
OPTIONAL - 2 x 600 door wardrobe
by specialist to suit full width & floor
to ceiling height of wardrobe space -
IMPORTANT - supplier to undertake
on site measure
C.U.
107
810
64
ST
21
21
21
21
21
21
21
21
CLITHEROE
PART L 2013
KEY
filled with 100mm Knauf Supafil
(034) with 100mm Celcon Solar or similar block.