1/8S1A45591-0903/2020
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibilityis assumed by Schneider Electric for any consequences arising out of the use of this product.© 2019 Schneider Electric. All Rights Reserved.
DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Only appropriately trained persons who are familiar with and understand the contents of this manual and all other pertinent product documentation and who have received safety training to recognize and avoid hazards involved are authorized to work on and with this drive system. Installation, adjustment, repair, and maintenance must be performed by qualified personnel.• The system integrator is responsible for compliance with all local and national electrical code requirements as well as all other applicable regulations with respect to grounding of all equipment.• Many components of the product, including the printed circuit boards, operate with mains voltage. Do not touch. Use only electrically insulated tools.• Do not touch unshielded components or terminals with voltage present.• Motors can generate voltage when the shaft is rotated. Prior to performing any type of work on the drive system, block the motor shaft to prevent rotation.• AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of unused conductors of the motor cable.• Do not short across the DC bus terminals or the DC bus capacitors or the braking resistor terminals.• Before performing work on the drive system:
- Disconnect all power, including external control power that may be present.- Place a "Do Not Turn On" label on all power switches.- Lock all power switches in the open position.- Wait 15 minutes to allow the DC bus capacitors to discharge. The DC bus LED is not an indicator of the absence of DC bus voltage that can exceed 800 Vdc.- Measure the voltage on the DC bus between the DC bus terminals (PA/+ and PC/-) using a properly rated voltmeter to verify that the voltage is <42 Vdc.- If the DC bus capacitors do not discharge properly, contact your local Schneider Electric representative. Do not repair or operate the product.
• Install and close all covers before applying voltage.Failure to follow these instructions will result in death or serious injury.
Option modules Altivar - LexiumS1A4559109
VW3A3601 / VW3A3608VW3A3616 / VW3A3627
VW3A3619
VW3A3609VW3A3628VW3A3725VW3M3301
VW3A3720VW3A3721VW3M3308
VW3A3530D
VW3A3607VW3A3618
www.schneider-electric.com2/8S1A45591-09
Lexium MV DriveATV32 ATV320 ATV340 ATV600 (1) ATV900 LXM32 ATV6000
VW3A3601 EtherCAT V1.2IE03(V1.1IE08)
V2.7IE23(V1.9IE09)
V1.1IE02(V1.11IE01)
V1.2IE02(V1.8IE05) ✔
VW3A3607 PROFIBUS DP V1.1IE01(V1.5IE01)
V2.7IE23(V1.12IE01)
V1.1IE02(V1.12IE01)
V1.1IE01(V1.9IE01)
V1.1IE01(V1.10IE01) ✔
VW3A3609 DeviceNet V1.1IE01(V1.1IE01)
V2.7IE23(V1.8IE01)
V1.1IE02(V1.8IE01)
V1.1IE01(V1.5IE05)
V1.1IE01(V1.5IE05) ✔
VW3A3616 Ethernet TCP/IP V1.1IE01(V1.2IE01)
V2.7IE23(V1.EIE01)
VW3A3619 POWERLINK V1.5IE08(V1.0IE08)
V2.7IE23(V1.0IE08)
VW3A3627 PROFINET V1.8IE11(V1.0IE15)
V2.7IE23(V1.6IE01)
V1.1IE02(V1.6IE01)
V1.1IE01(V1.3IE01)
V1.1IE01(V1.3IE01) ✔
VW3A3720 Ethernet IP / Modbus TCP V1.5IE11(2)(V1.8IE12)
VW3A3721 Ethernet IP / Modbus TCP+ MultiDrive Link
V1.6IE12(2) (V1.8IE13)
VW3A3725 BACnet MS/TP V1.7IE16(V1.1IEXX)
VW3M3301 DeviceNet
VW3M3308 PROFINET
VW3A3530D ATV dPAC Module
Drive version ≥(Module version ≥ )
VW3A3608VW3A3618VW3A3628
CANopen V1.2IE03(V1.1IE01)
V2.7IE23(V1.1IE01)
V1.1IE02(V1.1IE01) ✔
Altivar Machine Altivar Process
V1.1IE01(V1.1IE01)
V1.0IE03(✔)
V1.1IE01(V1.1IE01)
V2.2IE24(V1.1IE04)
V1.8IE14(V1.1IE04)
V1.5IE10(V1.1IE04)
Upcoming commercialization,for the Altivar Firmware Version, contact your Schneider Electric Customer Care
Center on www.se.com/CCC
(1) ATV610 is compatible only with VW3A3607 PROFIBUS DP fieldbus module.(2) Drive version ≥ V2.2IE24 is only compatible with module version ≥ V1.15IE18.
V1.4IE06(V1.1IE08)
V1.0IE03(V1.3IE01)
V1.0IE03(V1.1IE31)
V1.24IE03(V1.0IE11)
≥V1.0IE03≤V1.20IE05
(V1.0)
Option Module
S1A45591-09 3/8 www.schneider-electric.com
ATV32Mounting
ATV320
4)
XXXXXX
XX
3)
1)
2)
5)
XXXXXXXXXXXXXXXX
!
XXXXXX
XX
!
www.schneider-electric.com4/8
ATV32Removing
ATV320
S1A45591-09
1) 2)
www.schneider-electric.com5/8
ATV320Mounting
Removing
S1A45591-09
CLIC
!
NVE22661
VW3A3600
S1A45591-09 6/8 www.schneider-electric.com
Removing
LXM32M
MountingATV340
1 2 3
1
2
4
3
!
CLIC
Slot 1
Slot 2
Slot 3
S1A45591-09 7/8 www.schneider-electric.com
ATV340, ATV600, ATV900STATUS
ETH LNK
ETH NS
ASF
COM
-----
-----
MNS
-----
VW3A36
09
LNK1
LNK2
BF
SF
VW3A36
27
RUN
-----
BF
VW3A36
07
RUN
-----
ERR
-----
VW3A36
18
VW3A36
08
VW3A36
28
1)
Mounting
ATV600
ATV340, ATV900
!2)
E
LNK2
LNK1MS
NS
VW3A37
20
VW3A37
21
3)
AB
4)
STATUS
ASF!
COM
LNK1
MS
NS
LNK2
5)
VW3A36
28
VW3A36
18
VW3A36
08
RUN
ERR
VW3A36
27
SF
BF
VW3A36
01
ERR
RUNECT
VW3A36
07
BF
-----
VW3A36
09
MNS
-----
MS
RX
TX
-----
VW3A37
25
L / A1S/E
L / A2
VW3A36
19
LNK1RUN/ERR
NSLNK2
VW3A
3530
D
ES/E
VW3A36
19
NSRUN/ERR
VW3A35
30D
8/8S1A45591-09 www.schneider-electric.com
1)
2)
ATV340, ATV600, ATV900 Removing