FEBRUARY 2013 UT-ID 3.4.6-1 OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation Instructions

OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

Embed Size (px)

Citation preview

Page 1: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

F E B R U A R Y 2 0 1 3

UT-ID 3.4.6-1

OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation Instructions

Page 2: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

F E B R U A R Y 2 0 1 3

i

OPTIGUARD™ Installation Instructions

212 West Newberry Road, Bloomfield, CT

Phone (800) 328-7840 • Fax (860) 286-1625

Quick Comparison

OPTIGUARD™ (Possible Standard Mounting Configurations)

Page 3: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

ii

NONDISCLOSURE WARNING

This work contains proprietary information and is the property of Otis Elevator Company. It is distributed only to those employees with a need to know the information and may not be reproduced, disclosed, or distributed to any person outside the employ of Otis Elevator Company without written authorization from an officer thereof. Otis competitors, customers, former employees, retirees, members of the general public and consultants not bound by a written nondisclosure agreement are among those outside the employ of Otis. In the event that an employee in the possession of this work no longer needs the information, retires, resigns, is terminated or laid off from Otis, or in the event that a person outside the employ of Otis comes into possession of this work, such employee or person should destroy the work or return it to Otis.

Any unauthorized reproduction, disclosure or distribution by any person of any portion of this work may be a breach of a duty owed by such person to Otis Elevator Company and could result in damages actionable at law.

PROHIBITION ON COPYING

Any unauthorized reproduction, disclosure or distribution of copies by any person of any portion of the work may be a violation of Copyright Law of the United States of America and other countries, could result in the awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement and may result in further civil and criminal penalties. All rights reserved.

PUBLICATION CATALOGING DATA

First Issue: February 2013 Master Index Control Number: Part Number: UT-ID 3.4.6-1

Comments or questions about the information contained in this publication should be directed to:

UNITEC 212 West Newberry Road Bloomfield, CT 06002 (800) 328-7840 Phone (860) 286-1625 Fax

Unpublished Work - © UNITEC, 2013

Page 4: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 3

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Warnings

• This product is for use in installations in which the distance between detectors does not exceed 13 ft. 1 in. (157 inches or 4 meters) when the doors are fully open.

• When power is removed from equipment, please follow Company policy and perform the lockout/tagout procedure.

• If Fireman’s Service (Phase 1 or 2) is required in your area, OPTIGUARD™ must be installed on an operator with nudging features.

• If replacing a light-ray reversal device (with a cutout switch in the COP) with OPTIGUARD™, you must disable the cutout switch.

• OPTIGUARD™must be active until fully closed. If a desensitizing relay contact (GH or similar) is present, it must be disabled. The relay is usually present in Otis MEMCO® detectors and light-ray reversal devices.

Page 5: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 4

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Description

The infrared light curtain OPTIGUARD™ consists of a transmitter (TX) and a receiver (RX) edge, both of which have a built-in controller. These two active parts are electrically connected directly to the door drive unit of the elevator and mechanically mounted either to the car door faces and/or to the strike jamb.

The transmitter and the receiver edge build up a grid of infrared beams, which cover the door entrance to a height of 1,800 mm (6 feet). Due to the use of criss cross beams, the number of active beams used for the door protection is higher than the number of elements.

The transmitter and the receiver require a power supply of 14 to 30 VDC. The output of the receiver is a push/pull (PNP/NPN) stage, which is compatible with loads connected to either positive (PNP) or negative (NPN) power.

The Universal Power Supply (UPS) provides the power described above for the transmitter and receiver edges. It also includes a relay output that provides the N.O. or N.C. contact signal to the door operator circuit to reopen the elevator cab doors. The UPS accepts any voltage available from 20 to 265 VAC or VDC without any special wiring or adjustments. The polarity of DC voltage is irrelevant.

OPTIGUARD™ p/n AAA24591AM2-UNITEC includes the following items:

Qty Description 1 Transmitter 1 Receiver 1 Multi-Voltage Universal Power Supply 1 Transmitter Cable 1 Receiver Cable 2 Spacer Profiles (see p. 6) 2 Aluminum Mounting Profile (see p. 6) 2 Vision Shields (see p. 6) 1 Shipping Kit. Spacer 2 Cable Guide Wires 1 Quick-Start Guide

Page 6: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 5

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Features of the OPTIGUARD™ • Very robust and extremely compact design

• No ground connection necessary

• Designed to last: Gold plated contacts Special cable that withstands more than 20 million door openings (when

properly installed)

• Plug-and-play edges with integrated controller

• No link connection between transmitter and receiver due to optical synchronization principle

• Suitable for side or center-opening doors

• Suitable for metal or glass doors

• Universal power supply 17-265 AC or DC

• Visible light indicator (transmitter + receiver)

Page 7: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 6

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Installation of Transmitter (TX) and Receiver (RX)

The installation should be completed using the following sequence:

Mount the Transmitter and Receiver

The transmitter and receiver edges can be mounted either to the elevator cab doors (center-opening) or to the elevator cab door and the strike jamb (side opening).

The black “eyes” in the aluminum profile are the optical elements that form the front of the edge. This front side must face the companion piece, which is mounted on the opposite door or on the strike jam.

NOTE: The receiver (the edge with the blue connector) can be sensitive to "foreign" light. Avoid other sources of external light, including the transmitter of a different light curtain or single beam photo-electric system.

While the OPTIGUARD™ is designed to be tolerant of bright sunlight, it is better to mount the receiver so sunlight does not shine directly into the receiver lenses. This minimizes the possibility that the receiver will be “blinded” by direct sunlight.

Additional mounting hardware is included in the light curtain kit (e.g., mounting profiles, spacer profiles, and vision shields). Vision shields simply snap on over the transmitter and receiver to help protect them from damage.

The transmitter and receiver can be mounted directly to the elevator cab door or strike jamb, or the additional mounting hardware provided can be used to create a more aesthetic installation or fill large gaps that may exist between the elevator cab doors and the hoistway doors. The following illustrations provide examples of how this mounting hardware can be used:

Figure 1

Page 8: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 7

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

NOTE: It is important that the alignment angle of the emitter to the receiver is less than ± 10° when the door is fully closed. We recommend that you keep this angle as close to zero as possible.

Figure 2: Mounting Details in Center Opening Doors without Spacer

Figure 3: Mounting Details in Center Opening Doors with Spacer

Page 9: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 8

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Figure 4: Mounting Details of Side Opening Doors without Spacer

“M” Max for Given “D” “D” Min

.18 in. 1.0 in.

.25 in. 1.5 in.

.35 in. 2.0 in.

.44 in. 2.5 in.

.53 in. 3.0 in.

Figure 5: Mounting Details of Side Opening Doors with Spacer

Page 10: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 9

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Figure 6: Strike Mount

Example Mounting Using Auxiliary Strike Angle/Bracket (where existing strike column has insufficient mounting surface area)

NOTE: Parts called out in Figure 6 above are not included in the standard OPTIGUARD kit. These can be specified and ordered separately from UNITEC.

• p/n AAA283AQE5 Mount “Z” Bracket—84-inch Opening, SS4

• p/n AAA283AQE1 Mount “L” Bracket—84-inch Opening, SS4

• p/n 124DK5 Tamper Resistant Screw, SS4

• Type ABA316FUL_ Spacer Profile

Page 11: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 10

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Figure 7: Strike Jamb Mounted Detector/Emitter (option)

Table 1

Dimensions “P” that can be achieved using standard kit contents:

Dimensions “Q” that can be achieved using standard kit and 1 of 3 optional brackets type ABA316FUL_

P Using Aluminum Profile P = .75 Q = 1.38 Using ABA316FUL2

Q = P + .63 = Using Spacer Profile P = 1.4 Q = 2.03

Using Aluminum Profile P = .75 Q = 1.75 Using ABA316FUL3 Q = P + 1.0 = Using Spacer Profile P = 1.4 Q = 2.4

Using Aluminum Profile P = .75 Q = 2.0 Using ABA316FUL4 Q = P + 1.25 = Using Spacer Profile P = 1.4 Q = 2.65

Page 12: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 11

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

NOTE: It is important that the alignment angle of the emitter to the receiver is less than ± 10° when the door is fully closed. We recommend that you keep this angle as close to zero as possible.

NOTE: When using vision shields, you need to provide a minimal gap (see Figures 4–5) between the mounting profile of the light curtain and any perpendicular mounting surface immediately to the left or right of the mounting profile. Otherwise you will be unable to snap on the vision shield over the light curtain.

NOTE: The light curtain is designed to have high immunity to ambient light conditions (100,000 Lux). Avoid exposing the receiver unit to sources of light that exceed this value (e.g., strobe lights, other optical sensors, and direct sunlight) as it may be “blinded” by the light source.

Important Mounting Guidelines

It is also important to observe the following mounting guidelines:

• Never scratch or paint the optical lenses because they form the light path.

• Do not drill additional holes into the light curtain transmitter or receiver as this may cause internal damage to the device.

• Do not bend or twist the transmitter or receiver edges.

• Oil may damage the cable. Contamination must therefore be avoided at all times.

• Avoid external light from other infrared light sources like photo eyes, light barriers, or direct sunlight.

• For installation of the transmitter and receiver:

Exit both cables in the same direction.

Do not over-bend the cables or expose them to tension.

Ensure that the cables are away from AC main power or sources of high voltage.

Do not force, stretch, or squeeze the cables.

Ensure that the cable is well fastened and routed.

Keep the transmitter and receiver clean from dust and dirt.

Avoid contamination by oil or greasy liquids.

Avoid obstructions caused by objects entering the detection area.

Page 13: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 12

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Cable Installation

CAUTION: Route cables properly to prevent damage.

The cables are color-coded. The transmitter cable features white connectors and the receiver cable features blue connectors. Make sure you connect the white cable ends together and the blue cable ends together. The transmitter and receiver cables are not interchangeable. If the white plug is connected to the blue connector (or vice versa), the system will not function correctly.

Route the cables properly using appropriate mounting material, neoprene cable ties, and cable guide wires.

CAUTION: If the cables are not properly fixed and guided, their lifetime could be reduced greatly. Cables can also be damaged due to swing or snag in the hoistway. Carefully follow the cable guide instructions, which can be found in this TIP.

Pay close attention to proper cable installation to ensure the highest possible reliability and lifespan of the light curtain. A properly installed cable will withstand more than 20 million door movements in applications where the light curtain is mounted on a moving door, while a poorly installed cable may break after less than 100,000 door movements.

Do not expose the cables to oil or other greasy liquids.

Ensure that the cable bending radii are greater than 3.2 inches (80 mm).

Universal Power Supply Installation

The universal power supply unit should be mounted in a convenient place on the car top. It can be mounted either horizontally or vertically using four mounting screws (see Figures 14–15).

CAUTION: The PCB is sensitive to electrostatic discharge and must be handled with care to prevent callbacks. Use anti-static procedures when handling it.

Page 14: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 13

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Figure 8: Warning Label on Power Supply

Figure 9: Power Supply Piping

Electrical Connections

The following electrical connections are made at the orange 6-pole terminal block on the Universal Power Supply. Connect supply voltage to N, P and . Make sure that the supply voltage is between 20 and 265 volts AC or DC.

N AC Neutral or DC (plus or minus) COM Relay Common Signal

P AC Line or DC (minus or plus) NO Normally Open Contact

Protective ground NC Normally Closed Contact

Page 15: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 14

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Connect the source signal from the elevator door control to the COM terminal. Connect the return signal to the elevator door control to either the normally open (NO) or normally closed (NC) contact as required for your application. The following illustrations show the status of the relay contacts.

Figure 10: Normally Open Contacts

CLEAR OPENING Figure 11: Normally Closed Contacts

OBSTRUCTION IN OPENING

CAUTION: The maximum contact rating of the output relay is: • 250 VAC / 8 A

• 125 VDC / 0,5 A

• 30 VDC / 8 A

• min. 5 VDC / 10 m

When switching DC voltage loads higher than referenced here, use a pilot relay (not included).

Connect Light Curtain to Universal Power Supply

The light curtain system has two cables that connect the transmitter/receiver to the universal power supply.

1. Connect the blue receiver cable to the blue receiver cable receptacle on the receiver edge. Plug the 3-pin WAGO plug into the corresponding receptacle on the UPS control board.

2. Connect the white transmitter cable to the white transmitter cable receptacle on the transmitter edge. Plug the 2-pin WAGO plug into the corresponding receptacle on the UPS control board.

Page 16: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 15

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Power-Up and Test

Turn on power after the installation is completed. The LED indicators should have the following behavior:

• The green LED on the universal power supply should be illuminated when powered.

• The amber LED on the universal power supply indicates the status of the light curtain and the output relay. It should be illuminated when there is an obstruction and should be dark when the detection field is clear of obstruction.

• The green LED on the transmitter edge indicates that the transmitter is powered.

• The amber LED on the receiver edge indicates whether an obstruction of the detection field has occurred. It should be illuminated when there is an obstruction and should be dark when the detection field is clear of obstruction.

LED Indicator Meanings

Edge / UPS LED Color LED On LED Off

Receiver / UPS Amber

Power OK, Object Detected

or Not Aligned

No Power or No Object

Transmitter / UPS Green Power OK No Power

When the light curtain is obstructed during door closure, the obstruction should cause the doors to reopen.

Installation Tip

The UPS has a built-in buzzer feature. The buzzer can be left enabled or disabled. When the buzzer is switched on with the sliding switch located on the universal power supply, an obstruction is indicated by a buzzer signal. This feature may be helpful for troubleshooting, which is described in the next section.

Figure 12 provides basic connection and system behavior information.

Page 17: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 16

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Figure 12: Basic Connection and System Behavior Information

Page 18: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 17

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Troubleshooting

If the light curtain does not operate as required:

1. Cycle power to the universal power supply.

2. Make sure you have connected the correct relay output for your application (i.e., NO vs. NC contact).

3. Check whether the green indicator LED in the transmitter edge is on. If not, verify that the cable connection between the UPS and the transmitter is secure.

4. Check whether the amber LED in the receiver edge is on. If so, make sure there are no obstacles between the transmitter and the receiver. If there are no objects, but the LED remains on, verify the cable connection between the UPS and the receiver is secure. If the output signal of the receiver is not stable during door closing, make sure that:

• The cables have not been routed near sources of electrical noise generated by a door drive or other device.

• No obstacles are entering the detection field during door closure.

• The edges are properly installed so that they cannot swing or vibrate, thus causing misalignment.

• The optical elements of the edges are clean and not covered by dust or dirt.

Page 19: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 18

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Table 2: Troubleshooting Synopsis

Problem What to check?

No function Door remains open Green and amber LEDs off

Is the power supply good? Is there a broken power wire? Defective control unit?

Door remains open, free protective area

Is light curtain correctly connected to the universal power supply? No / bad grounding (PE) connection? Are all beams uninterrupted? Are the sensors facing one another? Are the sensors/vision shields dirty? Are the emitter and detector poorly aligned? Is there excessive EMC interference e.g. door drive / fluorescent lamps?

Random door openings

Check for bad grounding (PE) connection. Are the sensors/vision shields dirty? Is there excessive EMC interference e.g. door drive / fluorescent lamps? Is the cable to the receiver or emitter damaged? Check for break in the cables by moving the cable by hand. Is there any interference between other infrared sensors with the receiver directly or via mirroring from shiny surfaces?

Page 20: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 19

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Technical Data

Table 3: Universal Power Supply

Input Power 20–265 VAC / DC (For the USA + Canada use "Greenfield Fittings" with voltage above 42 volts)

Ripple voltage 10 % on UPS maximum

Current Consumption < 200 mA @ 24 VDC < 60 mA @ 240 VAC

Output type Relay with NC / NO contacts

Relay current rating

AC: 250 VAC / 8 A DC: 125 VDC / 0.5 A 30 VDC / 8 A, min. 5 VDC / 10 mA

Connections WAGO, 6 x 5.08 for power supply and output WAGO, 3 x 3.81 for OPTIGUARD™ /Mini Rx-edge WAGO, 2 x 3.81 for OPTIGUARD™ /Mini Tx-edge

DC output voltage 24 VDC ± 10% Output rated current 200 mA Temperature Range -5° to 132° F (-20 to +55°C)

Table 4: Light Curtain

Number optical elements 32 Number of optical beams 154 Operating range 0 to 13.1 ft (0 to 4 m) Dimensions 0.47 x 0.63 x 78.74 inches ( 12 x 16 x 2,000 mm) Protection height 6 ft (1,800 mm) First beam 0.78 in (20 mm) Max. Ambient Light 100,000 Lux (DC Light) Protection class IP 65 / NEMA 12 Temperature range -40 to +140 °F (-40 to +60°C) Cable length 5 m, detachable Cable lifetime 20 million movements

Page 21: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 20

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Dimensions

Figure 13: UPS Side View

Figure 14: UPS Top View

Page 22: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 21

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Figure 15: UPS Enclosure Box (moisture-resistant)

(dimensions in millimeters)

Figure 16: Transmitter and Receiver Mounting

(dimensions in millimeters)

Page 23: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 22

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Figure 17: Light Curtain Overview

Page 24: OPTIGUARD™ p/n AAA24591AM2-UNITEC Installation · PDF fileOPTIGUARD™ Installation Instructions 212 West Newberry Road, Bloomfield, CT Phone (800) 328-7840 • Fax (860) 286-1625

OPTIGUARD™ INSTALLATION INSTRUCTIONS

UT-ID 3.4.6-1Page 23

February 2013

WARNING: The use and ownership of this work is defined by and subject to the legend contained on the front page of this document.

Appendix A: Related Part Numbers

Table 5: Related Part Numbers Description Part Number

OPTIGUARD Includes all items listed below. AAA24591AM2-UNITEC Receiver Edge, 32 Optical Elements AAA24591AM100 Transmitter Edge, 32 Optical Elements AAA24591AM101 Receiver to UPS Cable with Wago Connector AAA24591AM104 Transmitter to UPS Cable with Wago Connector AAA24591AM105 Vision Shield, 2100 mm (Qty = 2) AAA24591AM112 Mounting Profile, 2067 mm (Qty = 2) AAA24591AM113 Spacer Profile, 2100 mm (Qty = 2) AAA24591AM114 Universal Power Supply, 17–240 VAC/DC AAA24591AM115 Cable Guide Wires (Qty = 2) AAA24591AM116

Table 6: Optional Parts (not included in standard OPTIGUARD kit) Description Part Number

“L” Angle (for strike)*—84 in. Opening, SS4, w/ Hardware AAA283AQE1 “Z” Bracket (for strike)*—84 in. Opening, SS4, w/ Hardware AAA283AQE5 Bracket, Mounting, A = 0.56 in. ABA316FUL2 Bracket, Mounting, A = 1.00 in. ABA316FUL3 Bracket, Mounting, A = 1.25 in. ABA316FUL4 Molding, Astragal, Type A, 192 in. Roll, Self-Stick (Mod only) AAA402ZV1 Molding, Astragal, Type A, 720 in. Roll, Self-Stick (Mod only) AAA402ZV2 Molding, Astragal, Type B, 192 in. Roll, Self-Stick (Mod only) AAA402ZV3 Molding, Astragal, Type B, 600 in. Roll, Self-Stick (Mod only) AAA402ZV4 Tamper Resistant Screw for Auxiliary Strike Angle or “Z” Bracket Mounting, SS4 124DK5

* Other strike shapes in brass and other lengths are available by special order.