Highly physiological cannulae
Cannulae that can
Arterial and Venous CannulaeOPTIFLOW
1. Assmann et al. Artificial Organs 2014; 39(3): 203-211
2. Pfeiffer et al. Interactive Cardiovascular and Thoracic Surgery 2015; 20:863-5
2
OPTIFLOW CANNULAE
Optiflow Cannulae are highly physiological cannulae designed to reduce patient complications and meet procedural needs. The Optiflow Arterial cannula features a dispersive tip that reduces shear stress on the aortic wall.1 The Optiflow Venous cannula features a compact swirled tip that provides clear surgical view and high flow drainage, especially in minimally invasive procedures.2
help reduce patient complications
Optiflow Arterial and Venous Cannulae
Clear surgical view and high
venous drainage in MICS
Reduced aortic wall shear stress
Low pressure drops
can
3
The Optiflow Arterial cannula is available with straight and bent tips, both of which feature an innovative and unique 3-dimensional dispersion basket that allows a more physiological flow. This tip design has been shown to reduce the pressure of the inlet jet stream on the aorta, thus mitigating arterial embolization of atherosclerotic plaques that are the potential cause of stroke or ischemia of other organs.¹
Large opening outlet area
Optiflow Arterial CannulaeLess Jet, More Natural Dispersion
3-dimensional dispersion of the
blood flow
Optiflow
Standard
Smooth tip facilitatesinsertion
Curved Tip, Non-reinforced Tubing
A281
Curved Tip, Wire-reinforced Tubing
A282
Straight Tip,Wire-reinforced Tubing
A292
Straight Tip,Non-reinforced Tubing
A291
Available Configurations
Di-ethylhexyl phtalate plasticizer
free tubing with or without
wire-reinforcement
Optiflow Arterial Cannulae21 and 24 Fr sizes available
ARTERIAL
4
Reduced Aortic Wall Shear Stress
Pressure Drop
Plaque dislodgments from the aortic wall may induce neurological complications in adult patients undergoing extracorporeal circulation in cardiac surgery.Embolization of atherosclerotic plaques has been reported to be correlated with enhanced maximum wall shear stress values of the aortic arch cannula on the aortic wall.Dr Assmann’s study evaluated the shear stress values of an Optiflow Arterial cannula dispersive tip in comparison to a standard tip.¹
Wall Shear Stress (Pascal)
Optiflow reduced the maximum and average aortic wall shear stress values to approximately 50% compared to control cannulas.
Optiflow have the potential to reduce ECC-related complications such as stroke, endothelial damage and hemolysis.1
ARTERIAL • OPTIFLOW CANNULAE
25.024.023.022.02 1.020.01 9.01 8.01 7.01 6.01 5.01 4.01 3.01 2.01 1 .01 0.09.08.07.06.05.04.03.02.01 .00
Optiflow dispersive tip Standard tip
All data extracted from relative Instructions For Use
Flow Rate (L/min)
24 Fr Optiflow
24 Fr Medtronic Select 3D
24 Fr Edwards EZ-Glide
24 Fr Edwards Embol-X
Pres
sure
dro
p (m
mH
g)
120
100
80
60
40
20
0
42 61 530
24 Fr Optiflow = 30mmHg at 5L/min
5
Compact size for improved view in narrow spaces
Di-ethylhexyl phtalate plasticizer
free tubing with or without
wire-reinforcement
The Optiflow Venous cannula features a special swirled tip design with multiple side holes that facilitate active and physiological venous drainage regardless of the position of the heart.This cannula is more compact than a standard cannula which makes it easier to insert and remove while improving the surgical view, especially in minimally invasive procedures.The special tip can help reduce patient complications often associated with femoral venous cannulation, such as deep wounds and high bleeding.¹
Optiflow Venous CannulaLess Pressure, More Active Drainage
Unique 13 cm swirled and grooved
tip with multiple side holes
V182-29Optiflow Venous Cannula29 Fr size available
Distal central opening
VENOUS
6
In our experience, the innovative small-sized, 29-Fr Optiflow cannula provides high-flow drainage across the entire cannula inserted into the right atrium without the need
for double cannulation and with no increase in central venous pressure.²
High Venous Drainage in Minimally Invasive Procedures
The use of direct venous cannulation in minimally invasive procedures helps avoid the risk of complications related to femoral cannulation.The Optiflow Venous cannula drains from the atrium and provides good visualization, making valve implantation easier while ensuring optimal venous drainage without the need for a double cannulation.2
Improved surgical view.
Pressure Drop
VENOUS • OPTIFLOW CANNULAE
120
100
80
60
40
20
0
0 42 6 81 53 7 9
Pres
sure
dro
p (m
mH
g)
Flow Rate (L/min)
29 Fr Optiflow = 48 mmHg at 5L/min
The venous cannula in situ, exiting thesurgical field with a right and upward arch.
7
05/1
6 09
295-
180/
A
© 2016 LivaNova all rights reserved.
Please always refer to the Instructions For Use (IFU) manual provided with each product for detailed information, warnings, precautions and possible adverse side effects.
Sorin Group Italia SrlA wholly-owned subsidiary of LivaNova PLCVia Statale 12 Nord, 86 - 41037 Mirandola (MO) ItalyТеl: +39 0535 29811 - Fax: +39 0535 [email protected]